Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-AOC MAIN ROAD CHHATABAD KATRASGARH DHANBAD DHANBAD 829113 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 829113 | ₹2.8 L Quoted ₹2.3 L | L1 | Accepted-AOC Awarded L1 Bidder |
| 2 | L2₹2.4 LRejected-Finance DEY VILLA MURLI NAGAR KOYLA NAGAR KOYLA NAGAR DHANBAD JHARKHAND 826005 UDYAM JH 04 0009015 | DHANBAD | JHARKHAND | 826005 | ₹2.4 L | L2 | Rejected-Finance Stand L2 Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Work Experience not submitted as per NIT. |
Tender Value
₹3.1 L
EMD Value
₹3,886
Closing Date
31 Jan 2026, 5:00 pmClosed
General Manager(Ws)
Office of the General Manager(Ws), Washery Division, BCCL, Dhanbad
Electrical repairing/re-wiring of Officer Quarters (Qtr. No.- B/05, B/06 and D/02) in CCWO Colony for Washery Division.
2026_BCCL_351542_1
BCCL/WD/EnM/2025-26/16
Open Tender
Electrical and Maintenance Works
15 days
Washery Division
Please refer Tender documents.
10 documents required · 10 mandatory
₹3,886
31 Mar 2026
20 Jan 2026
2 Feb 2026
21 Jan 2026
31 Jan 2026
21 Jan 2026
21 Jan 2026 - 26 Jan 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required (Group-A)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required (Group-B)
Supplying and fixing 5/6 Amps.piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
Supplying and fixing 3Pin 5/6 Amps. piano socket Outlet on the existing switch box/ cover including connections etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Wiring for circuit/ submain wiring along with earth wire with the size-2X1.5sq.mm +1X1.5sq.mm earth wire of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Wiring for circuit/ submain wiring along with earth wire with the size-2X2.5sq.mm +1X2.5sq.mm earth wire of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Wiring for circuit/ submain wiring along with earth wire with the size-2X4sq.mm +1X4sq.mm earth wire of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Wiring for circuit/ submain wiring along with earth wire with the size-2X6sq.mm +1X6sq.mm earth wire of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Supplying and fixing 2+8Way SIngle Door way prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 Amps. rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Highly Skilled Labour Charge for Dismnatling of Old Wiring
Semi Skilled Labour Charge for Dismnatling of Old Wiring
Total impact of GST for the purpose of CTC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.71 MB
BOQ_364302.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid