Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.9 LAccepted-AOC A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | 1 | Accepted-AOC L1 bidder | |
| 2 | 2₹17.4 L+₹1.5 L (9.34%)Rejected-Finance | 2 | Rejected-Finance L2 | |
| 3 | 3₹17.9 L+₹2.0 L (12.3%)Rejected-Finance | 3 | Rejected-Finance L3 | |
| 4 | 4₹17.9 L+₹2.0 L (12.5%)Rejected-Finance | 4 | Rejected-Finance L4 | |
| 5 | 5₹18.2 L+₹2.3 L (14.3%)Rejected-Finance A 20 COMMERCIAL COMPLEX DR MUKHERJEE NAGAR KINGSWAY CAMP DELHI 110009 | NORTH | DELHI | 110009 | 5 | Rejected-Finance L5 |
Tender Value
₹20.4 L
EMD Value
₹40,757
Closing Date
25 Sept 2023, 10:00 amClosed
Executive Engineer
Office of the Executive Engineer,EE(Elec) Division,CSPZ
Improvement of EI and Fans in PUHC Vivekanand puri polyclinic under CSPZ.
2023_MCD_167927_1
MCD/TR/4801/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
City- SP, KISHAN GANJ
2 documents required · 2 mandatory
₹590
₹40,757
7 Dec 2023
16 Sept 2023
25 Sept 2023
16 Sept 2023
25 Sept 2023
17 Sept 2023
Amount
Improvement of EI and Fans in PUHC Vivekanand puri polyclinic under CSPZ.
OD4877/2023-2024: Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required Group C (1.15.3)
OD4878/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, Phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group C. (1.8.3)
OD4879/2023-2024: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (1.17.12) (a) 3x 2.5 sqmm
OD4880/2023-2024: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (b) 3x 6 sqmm(1.17.30)
OD4881/2023-2024: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (c) 3x 4 sqmm (1.17.21)
OD4882/2023-2024:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25 mm(1.21.2)
OD4883/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 amp switch(1.24.1)
OD4884/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (b) 3 pin 5/6 amp Socket Outlet(1.24.4)
OD4885/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (e) Bell Push(1.24.8)
OD4886/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (d) 6 pin 15/16 amp socket outlet(1.24.5)
OD4887/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (c) 15/16 amp switch(1.24.3)
OD4888/2023-2024:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, ?C? curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole(2.10.1)
OD4889/2023-2024:Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A(2.12.2)
OD4890/2023-2024:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (a) 8 Module (125 mmX125 mm)(1.27.5)
OD4891/2023-2024:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (b)12 Module (200 mmX150 mm)(1.27.6)
OD4892/2023-2024: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required(1.32)
OD4893/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 Way Double Door(2.3.3)
121.1:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
OD5341/2023-2024:P/F ABC (Aluminium Phosphate ) Power type Fire extinguisher of 6 kgs capacity complete in all respect with ISI mark i/c fixing arrangement etc complete as reqd.
OD5343/2023-2024:SITC of single phase monoblock pump set complete with all accessories workable on 240/415 Volt 50 Hz AC supply (a)1 hp (0.75KW) single phase pump set head from 12-30 metre suction and delivery 25*25 mm
OD5344/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open as required.upto 35 sqmm
OD5345/2023-2024:Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of following size on wall surface as required. Up to 35 sq,mm (clamped with 1mm thick saddle)
OD5347/2023-2024:Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450mm Sweep(1.50.1)
OD5348/2023-2024:Supply of 15" (380mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as reqd.
OD5349/2023-2024:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required(5.4)
OD5350/2023-2024:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm(5.9)
OD5351/2023-2024: Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required(5.15)
OD5352/2023-2024:Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (a) 100Amp 16kA TPMCCB(2.2.1)
OD5354/2023-2024:Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (b) 125 Amp 16 kA TPMCCB(2.2.2)
Improvement of EI and Fans in PUHC Vivekanand puri polyclinic under CSPZ.
122.2.190:Supply and fixing of 32mm dia X 1 meter long G.I. Pipe (Medium Class) bracket for mounting of fluorescent/HPMV/HPSV Street Light fitting on pole including bending the pipe to the required shape , 2 nos 25mm X 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd.
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.2.33:SITC of 60W LED Street Light luminaire fitted with lens, top opening driver cover made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.84:Supplying and fixing of full stainless steel body self-contained drinking water cooler with cooling capacity 150ltr per hr, storage capacity 150ltr and suitable for 230V supply as required.
122.2.131:Supply, Installation, Testing and Commissioning of 1.5 Ton, 5 Star rated Inverter Split air conditioner with rotary compressor (R32 Refrigerant) having copper condenser complete with outdoor unit as required.
122.2.115:S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V
122.2.111:supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged)
122.2.77:SITC of On-line UPS with inbuilt isolation transformer suitable for single phase AC input and single phase AC output, Floor mounted type, indicative power backup time of 60 mins through SMF batteries. 3KVA
122.2.125:SITC of 40AH 12 Volt lead acid battery with rack etc. as requrired with four years comprehensive maintenance after one year defect laibility period and battery cost in 3rd year.
M/s Gyan Enterprises
MS PARDEEP
AMIT ELEVATOR SERVICES
ARPIT ELECTRIC CO.
bharat electricals & electronics
SHRIRAM SHARMA
Bidder Name
M/s Gyan Enterprises
AMIT ELEVATOR SERVICES
ARPIT ELECTRIC CO.
M/S. A.K. Electricals
bharat electricals & electronics
SHRIRAM SHARMA
MS PARDEEP
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .