Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹3.4 L+₹12,808 (3.91%)Rejected-AOC | L2 | Rejected-AOC L2 bidder | |
| 3 | L3₹3.8 L+₹52,134 (15.9%)Rejected-AOC | L3 | Rejected-AOC L3 bidder |
Tender Value
₹3.8 L
EMD Value
₹4,000
Closing Date
15 Jun 2022, 4:00 pmClosed
SE ETC I, Lucknow
Pareshna Bhawan, Vibhuti Khand, Lucknow
Work of patrolling and maintenance of 132 KV Sarojininagar Amausi and 132 KV SGPGI Urhretia Rly TSS line under ETD I, Lucknow
2022_UPTCL_702846_1
Short term e-tender 17/2022-23
Open Tender
Electrical Works
Piece-work
365 days
Lukcnow
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
A/c No 2408002190005438, IFS PUNB0691100, PNB, Lko
₹4,000
6 Aug 2022
25 May 2022
16 Jun 2022
25 May 2022
15 Jun 2022
25 May 2022
Amount
Following Works are to be carried out on 132 KV Sarojninagar- Amausi and 132 KV SGPGI- Uthretia ( Over head Portion) Railway TSS Line under ETD-I, Lucknow with all cost of men, misc. consumables and T&P etc. required for the job, as per direction of the concerned S.D.O./J.E.
1) Tower to Tower Patrolling (every month i.e. 12 times a year) of following 132 kV Railway TSS lines, from one end to other end and submission of Patrolling Report within Seven days after completion of each patrolling in Triplicate in prescribed proforma mentioning stolen/missing Tower parts & Tower Accessories such as missing Danger/ Phase/ Number Plates, Trees/ Tree branches & Bamboo Kothi falling in Line Corridor, damage to Earth wire, Conductor, Jumpers, Insulators & other Line Accessories damage to Foundation, Coping, Chimney, Earthing etc., with the help of Patrolling Teams:
i) 132 KV Sarojninagar- Amausi Railway TSS Line ( 6.3Kmx12 = 75.6 Km)
ii) 132 KV SGPGI- Uthretia Railway TSS ( Over head ) Line ( 1x12=12 Job)
2) Emergency Patrolling of following 132 kV Railway TSS line by experienced persons in case of any tripping/breakdown of line. The emergency Patrolling includes checking of Towers, conductors, earth wire, insulators, clamps, fittings etc. to locate the defect/fault/deficiencies. The emergency patrolling has to be started within 6 hours after receiving the call of SDO/JE.
i) 132 KV Sarojninagar- Amausi Railway TSS Line
ii) 132 KV SGPGI- Uthretia Railway TSS ( Over head ) Line
3) Lopping/Chopping of various species of tree branches falling under the corridor with all due care of safety and precaution to avoid any damage in near by building, crop & power/telephone lines passing near cicinity of the trees all the above lines along with throwing of cut branches at least 50 meter away from the line corridor as per details below (Two times in a year/ as per requirement)
i) 132 KV Sarojninagar- Amausi Railway TSS Line
ii) 132 KV SGPGI- Uthretia Railway TSS ( Over head ) Line
4) Lopping/Chopping of Spiniferous Babool tree branches falling inside the corridor with all due care of safety and precaution for all the following lines along with throwing of cut branches at least 50 meter away from the line corridor as per details below (Two times in a year/ as per requirement)
i) 132 KV Sarojninagar- Amausi Railway TSS Line
ii) 132 KV SGPGI- Uthretia Railway TSS ( Over head ) Line
5) Cutting of bamboo bushes falling under the corridor with all due care of safety and precaution to avoid any damage in near by building, crop & power/telephone lines passing near cicinity of the trees all the above lines along with throwing of cut branches at least 50 meter away from the line corridor as per details below : (Two times in a year/ as per requirement)
i) 132 KV Sarojninagar- Amausi Railway TSS Line ( 3x2=6No)
6) Checking & tightening of Jumpers of Tension Towers one time in a year. Including replacement of damaged Jumpers fasteners if needed and including carriage of material from store to site of work. For following Railway TSS lines:
i) 132 KV Sarojninagar- Amausi Railway TSS Line
ii) 132 KV SGPGI- Uthretia Railway TSS ( Over head ) Line
7) Cleaning of Disk Insulator String of suspension Tower one time in a year by removing all types of foreign particles sticking on the surface of disc insulator in suspension string of following Railway TSS lines:
i) 132 KV Sarojninagar- Amausi Railway TSS Line
ii) 132 KV SGPGI- Uthretia Railway TSS ( Over head ) Line
8) Replacement of missing tower parts along with fabrication work and fixing with tower after shifting of tower parts, nuts & bolts from UPPTCL store to work site in the above mentioned Railway TSS lines.
i) 132 KV Sarojninagar- Amausi Railway TSS Line
ii) 132 KV SGPGI- Uthretia Railway TSS ( Over head ) Line
9) Re-fixing and tightning of dislocated/ shifted Vibration Dampers to its Place including replacement of fasteners if required in the following Railway TSS Lines.
i) 132 KV Sarojninagar- Amausi Railway TSS Line
ii) 132 KV SGPGI- Uthretia Railway TSS ( Over head ) Line
10) Attending Emergency Breakdown and Replacement of damaged ACSR Panther conductor of 132 KV TSS Transmission line at various locations by using Single Tension fitting , MSCJ and Repaire sleave as per requirement.
11) Attending Emergency Breakdown due to falure of disc insulator and Replacement of Tension/Suspention string along with mobilization of skilled gang including carriage of materials from store to site and site to store for completion of work.
i) Tension string ( 120 KN Disc insulator)
ii) Suspention String ( 70 KN Disc insulator)
M/S T R TRADERS
MANAS ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .