Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.6 Cr+₹1.5 L (0.94%)Rejected-AOC | ₹1.6 Cr+₹1.5 L (0.94%) | L2 | Rejected-AOC Accepted |
| 3 | L3₹1.6 Cr+₹3.3 L (2.09%)Rejected-AOC | ₹1.6 Cr+₹3.3 L (2.09%) | L3 | Rejected-AOC Accepted |
| 4 | L4₹1.6 Cr+₹6.1 L (3.90%)Rejected-AOC | ₹1.6 Cr+₹6.1 L (3.90%) | L4 | Rejected-AOC Accepted |
| 5 | L5₹1.6 Cr+₹6.9 L (4.40%)Rejected-AOC | ₹1.6 Cr+₹6.9 L (4.40%) | L5 | Rejected-AOC Accepted |
Tender Value
₹1.8 Cr
EMD Value
₹50,000
Closing Date
22 Jul 2020, 6:00 pmClosed
Superintending Engineer
Siruvani Project Circle, Chunnambuthara, Palakkad
REPAIR ON GOOLIKKADAVU - CHITTOOR ROAD
2020_Irrig_370828_1
1/ET/SE/SPC/2020-21
Open Tender
Civil Works - Others
Item Rate
365 days
Agali
Please refer Tender documents.
6 documents required · 6 mandatory
₹6,600
Yes
online
₹50,000
Yes
5 Oct 2020
8 Jul 2020
28 Jul 2020
8 Jul 2020
22 Jul 2020
8 Jul 2020
8 Jul 2020 - 13 Jul 2020
Amount
Rebuild Kerala Initiative Work : Flood Damage Repair work at Goolikadavu -Chittur road.
2.3.1.A : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness <br> In area of light jungle - By Manual Means<br>
1.1 : Loading and Unloading of Stone Boulder/Stone aggregates/Sand/Kanker/Moorum.<br> Placing tipper at loading point, loading with front end loader, dumping, turning for return trip, excluding time for haulage and return trip
12.1.4.A : Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. <br> Hard Rock ( blasting prohibited) - Mechanical Means <br>
od9229/2020_2021/P1 : DOWEL BARS - Supplying and Providing MS dowel bars of size 25 mm dia of 2.0m long (1m in rock and 1m in concrete ) including drilling holes of 30mm dia and filling the gap with cement grout( 0.50kg/each) etc complete
12.1.B.1 : Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. <br> Ordinary Soil - Depth upto 3m - Mechanical Means <br>
12.4 : Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
13.5.C.P.1 : Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications PCC Grade M25 - Using concrete Mixer - Height upto 5m
od9555/2020_2021/P1 : Centering and shuttering including strutting, etc. and removal of form for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
od9234/2020_2021/P1 : PVC WEEP HOLES- Providing weep holes using 75mm dia. PVC pipes working pressure 4kg /sq.cm including cost of materials, conveyance, labour charges etc. complete.
14.1.B.1 : Furnishing and Placing Reinforced Cement Concrete Grade M25 Using Concrete Mixer in super-structure as per drawing and Technical Specification
13.6 : Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications
14.2 : Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
13.5.A : Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications PCC Grade M15 - Height upto 5m
od9553/2020_2021/P1 : Back filling behind abutment, wing wall and retaining wall complete as per drawing and Technical Specification -Excluding the cost of filling departmental earth.
14.1.A.1 : Furnishing and Placing Reinforced Cement Concrete Grade M20 Using Concrete Mixer in super-structure as per drawing and Technical Specification
12.8.A : Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications<br> PCC Grade M15 ( Without formwork) <br>
12.8.B : Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications <br> PCC Grade M20 (Without formwork) <br>
12.7.B : Random Rubble Masonry (coursed/uncoursed ) Work in Cement Mortar 1:3 in Foundation complete as per Drawing and Technical Specifications.
8.23.A : Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811.3 <br>
8.8 : Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
8.4.2 : Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.<br> 60 cm equilateral triangle
8.4.4 : Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.<br> 80 mm x 60 mm rectangular
BASHEERUDHEEN TK
mahalingam
anoop
ABUDUSALAM KK
Abdul Nasar T K
T S SARASAN
PVS CONSTRUCTIONS
AJITH PRASAD. T
SAKKEER.K.S
Bidder Name
mahalingam
ABUDUSALAM KK
Abdul Nasar T K
AJITH PRASAD. T
SIDDIK K.V
T S SARASAN
BASHEERUDHEEN TK
anoop
PVS CONSTRUCTIONS
SAKKEER.K.S
stage.html
html • 0.06 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_524957.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .