(1) S&T portion of work in connection with improvement of goods shed facilities at Jagdalpur (JDB) and Bodearpur (BDXX) goods sheds. (2) S&T portion of work in connection with Improvement of Goods shed facilities at Jeypore (JYP) goods sheds.
GOODSSHED_JYP_BDXX_JYP~ECOR
GOODSSHED_JYP_BDXX_JYP
Open
Works - General
6 Months
Bastar, Chhattisgarh
₹0
₹1.4 L
29 Dec 2025
5 Dec 2025
15 Dec 2025
A1-(EXECUTION) UBR
Drawing of switch board cable of sizes, power cable, UTP and STP cable etc through PVC pipes/ PVC channel etc up to the DP/Rosset to DP/Rosset.
Fixing of PVC conduit pipes firmly with wall and ceiling sealing with PVC saddles at regular interval of 50 Cm.
Transportation of HDPE pipe from the store to work site, laying of the same (With 4 3 mm nylon rope, pre inserted inside the HDPE pipe) in excavated trench/ already laid GI/ RCC pipe / tubes, jointing, leveling and end sealing the pipes, HDPE pipe, couplers and end caps shall be supplied by Railway, Nylon rope shall be supplied by the contractor.
Excavation of trenches of following depth and width 0.3 Meter detailed below including clearing of roots and trees etc. for all types of soil. This work also includes covering of cables laid in trench and backfilling, ramming, consolidation of soil as well as disposal of extra soil after cable is laid 4 as specified in Guidelines on Signalling Cable laying given by RDSO and any latest circular issued by CSTE/ECoR/BBS. Note: Before refilling of the trenches, the cable laid are to be tested and recorded for its insulation value and after satisfaction of site Engineer the refilling process should start and after monsoon the route is to be attended for backfilling the rain cuts, wash out of soils where ever found. Depth 1.0 M
Laying of Signalling/4 Quad/ 6 Quad/ Power Cable/Telecom cables/ Jelly filled cables of all sizes in excavated trench, through GI/RCC/DWC pipes etc. wherever required. This includes transportation of cables from the stores to work site and transportation of empty cable drums with left over cables from site to the stores at . The length of cable laid includes the length of cable coil for termination purpose. NOTE: The cables are to be carefully handled during loading, un-loading and transportation to work site. Any damage found in the cable after final testing, in view of mishandling of cables, shall be made good by the Tenderer. Cable should be maggered before and after laying and recorded in a register and submitted to the site Engineer.
Excavation of trenches including clearing of roots of trees etc., in rocky area up to a depth to be indicated by Railway Engineer at site as per the site condition [Minimum 0.6 meter] and 6 width 0.3 Mts. at the bottom. This includes concreting & plastering as per the instructions of site Engineer and complete back filling by digging earth from a lead of 30 Mtr. In case 0.8 meter depth or higher is achieved no concreting is required, otherwise concreting up to 100 mm thickness should be done. All materials required for the above works shall be supplied by the Contractor.
Excavation of trenches in all kinds of soils including soft rocky area and clearing of track etc. to a depth of 1.0 M and width of 0.3 M for track crossing /pucca road/level crossing gate/platform/station circulating area or any other place as advised by site Engineer including 7 transportation and laying of DWC/RCC/Split RCC/G.I. pipes with or without coupler. This includes repairing of track/pucca road/level crossing gate/ platform/station circulating area surface to original position by ramming and concreting wherever required soon after the work is over. DWC/RCC/GI pipes shall be supplied by the Railway. DWC pipes wherever required shall be supplied in 6 Mtr. length and shall be cut to size as per requirement. All other materials including cement are to be supplied by the contractor.
Cutting of masonary floor/walls at station building/ signal goomty/ Gate lodge at a depth of 0.5 mtr. to 1.0 mtr at places to be indicated by site Engineer for entering of cables inside the 8 building. Only G.I pipes supplied by Railway and all materials as clamps, bolts & nuts as instructed by site Engineer supplied by tenderer. This includes repairing of masonary floors/walls after the cables are taken inside. Cement, Sand required for the work shall be supplied by the tenderer and also transportation of G.I Pipe from Store by the tenderer.
Concreting (1:1.5:3) at a height of 150 mm & width of 0.3 m after laying of cables 9 where it is not possible to dig up to full depth of 1.2m/1.0m/0.8m in normal soil due to existing cables are in the trench, culverts, bridges. All materials including cement and chips of size 20mm. etc. to be supplied by the contractor. Payment for the depth of trench to be paid in proportionate to the rate specified for 1.2 mtr depth (excluding the concreting rate).
Trenching and fixing of G.I. pipes of different sizes/DWC pipes in hard rocky area up to a depth of 0.3 M to 0.6 M or at places as per instruction of site Engineer and concreting [1 : 3 : 6] up to height of 100 mm above the pipes. G.I. pipes with the socket/ DWC pipes shall be supplied by the 10 Railway. All other materials required for the works shall be supplied by the contractor. Note: [1] In case of girder bridges, G.I. pipes shall be suitably clamped by the contractor as advised by the site Engineer. Clamps shall be supplied by the contractor. [2] The work including excavation of trenches in hard rock area up to a depth of 0.3 M to 0.6 M and back filling, ramming after completion of work where ever required. [3] In case of concrete bridges clearing of ballast for laying of pipes and re arranging the Railway ballast after completion of work shall be done by the contractor.
Transportation of OFC from the store of to work site with care, and pushing/ pulling OFC through the HDPE pipes sealing of the duct by simple plugs. The cable is to be laid by 11 mechanised means. At inaccessible places where mechanised laying is not possible, the cable is to be laid manually by pulling through pre inserted rope. Empty cable drums with or without leftover cable should be returned to the store. This also includes testing of cable drums by OTDR in the store premises before transportation and submission of results thereof. Above/
A2-(EXECUTION) NON UBR
Splicing/Dropping/Termination of each fiber/pigtail in the LIU/IO Box/Terminal Joints 1 through fusion splicing of termination of OFC cables.The fibers terminated shall be tested and the test report (Hard copy and soft copy) shall be submitted to the site Engineer for records. Each fiber shall be properly marked with necessary ferrules/tags.
Excavation of trench of size 15cm X 30cm on platform with different surfaces duly cutting the platform with tile/platform cutting machine and laying of cables through CPVC/G.I. pipe of required size at site duly removing the existing platform surface such as shabad stone , granite etc., 2 without damaging . The surface of the platform to be restores to its original shape after completion of work. In case the platform surface stones are damaged , the contractor has to arrange for the tiles /tiles of similar type at his own cost. During digging , all precautions to be taken to avoid inconvenience to the travelling public . The work is to be carried out preferably when the platform is free from occupancy . Protection , barricading arrangement has to be done on platform till the work is completed. All materails including CPVC/GI pipe has to be arranged by the contractor as per the site condition.
Installation, Testing & Comissioning of CCTV Cameras and other accessories including all charges.
Installation, Testing & Commissioning of rack mountable 12 port Loaded LIU. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost. Above/
B1-(SUPPLY) UBR
Supply of Permanently lubricated two layer type HDPE duct, outer dia 40 mm, inner 1 dia 33 mm with three end plugs and two couplers for every Km length of pipe in length of 500 m confirming to RDSO Spec. No. RDSO/SPN/TC/45/2013.Rev.2.0 Amendment 2.0 or latest. Inspection by the Representative of Railway. Note: The HDPE Duct should be pre inserted with 4 mm nylon rope, inside the HDPE Duct.
Supply of double walled corrugated pipe 6 mtr in length, 120 mm outer dia and 103 2 mm inner dia, with one suitable coupler conforming to RDSO Specification No. RDSO/SPN/204/2011 Version 1.1 Amdt 1 or latest for under ground cable protection . Colour-Orange. Inspection by the Representative of Railway. Note: If required, the DWC pipe shall be supplied split in two halves
Supply of Perforated G.I. pipe of 100 mm dia with socket. G.I. pipe of make 3 TATA/JINDAL shall be as per IS: 1239 part-I/2004 Specification for medium gauge and shall be perforated by drilling 7 mm dia holes length wise in zig-zag manner staggered at a distance of 300 mm. Inspection by the Representative of Railway. Above/
B2-(SUPPLY) NON UBR
Supply of Full HD Bullet Type IP Colour camera as per RDSO spec. No: RDSO/SPN/TC/65/2021 Rev 6.0 or latest Clause 5.4 (Inspection by RDSO). Tenderer has to submit STQC (Standardizations Testing and Quality Certification) before supplying materials to SSE/Tele/JDB.
Supply of Full HD P/T/Z(Pan/Tilt/Zoom) IP Colour Camera as per RDSO 2 spec.No:RDSO/SPN/TC/ 65/2021 Rev 6.0 or latest Clause No. 7.0 (Inspection by RDSO). Tenderer has to submit STQC (Standardizations Testing and Quality Certification) before supplying materials to SSE/Tele/JDB.
Supply of full HD Bullet fixed Dome Camera with audio recording features as per RDSO 3 spec.No:RDSO/SPN/TC/65/2021 version 6.0 or latest. Make CP Plus or similar. (Inspection by RDSO). Tenderer has to submit STQC (Standardizations Testing and Quality Certification) before supplying materials to SSE/Tele/JDB.
Supply of 4 TB Surveillance Hard Disk as per RDSO spec.No:RDSO/SPN/TC/65/2021 version 6.0 or latest. Make: Seagate or similar. Inspection by the Representative of Railway.
Supply of LED Smart TV (55 inch) Android Operating system, Resolution-3840 x 2160 UHD, Dimension-Length x Breadth x Depth to suit 55 Inch LED TV, Power consumption 142 Watt Nominal, Two nos of Inbuilt TV Speaker each having min 10 watt, Brightness-300-to 399 CD/ Sq. Mtr, HDMI Ports-02 Nos, Both Table & Wall Mount Type. (Make Samsung, Sony, LG or Panasonic or similar). This item is inclusive of installation. Inspection by the Representative of Railway.
Supply of HDMI Cable Length 10 MTRS suitable for 4K based device . Make: Extron, Kramer, Aten , Logic or Similar. Inspection by the Representative of Railway.
Supply and transportation of 10/100/1000 mbps Media Converter (Single mode 20kms) 7 as per Specification No. RDSO/SPN/TC/103/2013 Rev.2 or latest. Make/Brand-DGISOL or similar. Accepted Make/Brand-Syrotech-GOMO-B13512-20 or similar. Inspection by the Representative of Railway.
Supply of CAT-6, UTP-Cable, CAT-6 Cable shall be compliant with latest EIA/TIA-568- B.2-1 standard for CAT 6 cable with Fire Retardant as per IEC/EN 60332-1. Brand: Digisol, Finolex, Molex or better. Inspection by the Representative of Railway.
Supply of Power cable 2.5 sq mm 3 core as per RDSO's Spec No. RDSO/SPN/TC/108/2019, Ver.0.0 or latest. Inspection by the Representative of Railway.
Supply of PVC PIPE 25mm (1 inch) Dia heavy duty suitable for electrical wiring ivory 10 colour IN &OUT smooth finish of 3meters length with conforming IS:9537/P.T 111/1983 or latest with ISI mark. Make: Avon, Aeroplast, Precision, tecmak or equivalent. Inspection by the Representative of Railway.
Supply of Rectangle PVC Channel (Six feet Two inches (50MM) Width). Inspection by the Representative of Railway.
Supply of 5 KVA online UPS with Back UP 120 Minutes,Battery Capacity:16000VAH, Warranty: 3 years or Higher, Make of Battery: Exide, Amaron, Microtek, Luminous or similar. This item is inclusive of installation. Inspection by RITES.
Supply of L2 8 port Gigabit Managed Network POE Switch with 2 SFP ports, Uplink Power Budget 150W Rack, including SM-SFP Module with distance minimum 20 KM, Wave length: TX- 1310nm, RX1550nm, 1.25Gbps speed. Inspection by the Representative of Railway.
Supply of Layer2, 24 port managebale switch with 4 SFP modules of Make: CISCO or similar as per RDSO Spec. No. RDSO/SPN/TC/83/2014, Rev. 1.0. Inspection by the Representative of Railway.
Supply of SFP (Small form factor pluggable) transceiver, Single Mode, Single LC . Wavelength : 1310 nm / 1550 nm as per specification in Annexure II. Inspection by the Representative of Railway.
Supply of 12 Core OFC cable with armoured ECCS tape (single mode OS1 HDPE Fibre 16 cable for Networking) as per conforming to IEC 60793-2, and to conform other normative specification as specified in IEC: 60793 part 1 and Part 2 make network cables or similar. Inspection by the Representative of Railway.
Supply of 6 Core armoured Mono mode OFC cable as per Spec No. IRS:TC 55-2006 Rev.1 or latest make by brand- Finolex or similar. Inspection by the Representative of Railway.
Supply of 20 mm diameter virgin material PE 100 HDPE pipe in coils. Inspection by the Representative of Railway.
Supply of 12 port loaded LIU rack mountable, LIU should be provided for terminating the optical fibre cables. It shall be provide minimum bending radius and splice trays shall function as a splice cover to pigtail splicing. Cable glands shall be provided for secure anchoring of incoming 19 cables. Rubber grommets shall be provided at the cable entry point for tight sealing. Type of patch panel: Flat, Height of patch panel 10, Number of ports : 12, Adapter: SC type. The splice tray should be reputed Make: D-Link/3 M/Digilink/Molex/DAX or similar. Inspection by the Representative of Railway.
Supply of Single Mode OFC Patch Cord(length-5m) (LC-SC/SC-SC/LC-LC/FC-LC) as per site requirement as per technical specification in Annexure-III. Inspection by the Representative of Railway.
Supply of 20 pair, 0.63 mm diameter Underground Polythene insulated Polythene 21 sheathed jelly filled telephone cable with Poly-Al Moisture Barrier as per RDSO Specification No.TEC/GR/CUG-01/03 AUG 2003 Amd. 3.0 or Latest. Make UM Cables LTD or similar. Inspection by the Representative of Railway.
Supply of push button telephone with caller ID & speaker make Beetel C 51 or similar. Inspection by the Representative of Railway.
Supply of RJ 45 Crimping Tool, to crimp the connectors RJ-45 and RJ-11. Make Kone, D- link, BestNet or similar. Inspection by the Representative of Railway.
Supply of TEC approved Digital Cable Fault Locator for low insulation Faults ,contact and open as per TEC Specification GR/TIE-05/03.07.2006. Firm's offer--ANDIG System 5289M. Inspection by the Representative of Railway.
Supply of FLUKE Hand Held 50KHz Digital Multimeter FLUKE 115 MAKE:- FLUKE or superior quality make or similar. Inspection by the Representative of Railway.
Supply of Digital Clamp On resistance tester & Leakage Current tester with LCD display up to 4 digits. Range: 0.01 Ohm to 1200 Ohm, current measurement range - 0.0mA to 20 26 Amps, Resistance measurement resolution 0.001 Ohm, Memory storage capability of up to 99 records, Long jaw size: minimum 65mm--32mm dia., Double insulation level protected from the external magnetic field as well as electric field, Automatic range selection, automatic selfcalibration, double insulation protection level. Make and model: (1) Metravi- CET-03 (2) Kusum meco - KM 1720 (3) Motwane- DECT3 or similar. Inspection by the Representative of Railway.
Supply of Cable Route Tracer with Rechargeable Battery Pack along with 10 Watt Transmitter. Detailed Specification as per Annexure- V with OEM TC/GC certificate. Make: Radiodetection UK/RD7200 or similar. Inspection by RITES.
Supply of Optical Power meter with features, Measurement Dynamic range + 10 dbm 28 to - 70 dbm, Wavelength 1310/1550nm, Connector FC/SC, Auto power OFF Mode and Manual. Make/Model: SKYCOMTOP 350D/DEVISOR AE210/STANLAY or similar. Inspection by the Representative of Railway.
Supply of Transmission Measuring Set ; Model;- 2031A Firm's offer: As per IRSTC:43/87 Anu Vidyut Make or similar. Inspection by the Representative of Railway.
Supply of MONOMODE OPTIC FIBRE CABLE (OFC) ARMOURED 24 FIBRE AS PER RDSO SPECIFICATION No IRS-TC- 55/2006 [Rev.1] WITH AMENDMENT No.3 OR LATEST make Brand UM Cables Ltd or similar. Inspection by the Representative of Railway. Above/
C1-(SUPPLY & INSTALLATION) UBR
Supply, installation, testing and commissioning of Maintenance free and permanent earth as per RDSO Specification No. RDSO/SPN/197 Version 1.0 and Technical Specification as per section H, Chapter 8 (Annexure-IV). Inspection by the Representative of Railway. Above/
C2-(SUPPLY & INSTALLATION) NON UBR
Supply, transportation, installation and commissioning of 19", 9 U wall mount Rack complete as per Specification mentioned in tender document as Annexure-VI. all the materials required for installation to be supplied by the contractor warranty. 3 Years. Inspection by the Representative of Railway.
Supply and erection of 15 feet GI Pipe of 4" dia IS No. 1239 (Part-1)1990 having Iron base plate 10 mm thick 30cm X 30cm welded at the bottom of pipe with 4 supports of iron bars of size 10mm dia. The 3 feet pipe shall be buried in the ground and 12 feet shall be above the ground. 2 The work includes digging of pit on platform, laying of cable in between poles in suitable underground GI pipes, erection of pole and filling the pit with 1:3:4 cement, concrete and sand. Final plastering should be done on the surface. The iron bracket on the top of the pole shall be provided to fix the CCTV camera and junction box. The work includes supply of all the material required in this item. Inspection by the Representative of Railway.
Supply & Installation of Outdoor Enclosure with Pole mounting kit. Pole mountable/Wall 3 mountable; Security lock; Insulation packings for mounting on Pole & Internal equipments; Ventilation with Weather Protection; Shock & Vibration resistant deisgn for internal equipment. Inspection by the Representative of Railway.
Supply & Installation of 19" 12 U rack. Rack shall be as per following technical spec. (a) Wall mount network rack of double section unit of depth 600mm (b) 19" robust frame structure (c) 4 Side doors with slam latch (d) Full vented top & bottom covered (e) Cable entry provision from bottom (f) Front tough tinted glass door with locking facility (g) AC main distribution box with 6 Nos. of 5 AMPS multi pin socket (h) 19" cable manager 1U - 02 Nos. (i) Front panel mounting hardware - 01 No. (j) 230V AC 90cfm fans - 02 Nos. Make: NETRACK, VALRACK or similar. Inspection by the Representative of Railway.
Supply, installation, testing & commissioning of 32 Channel Network Video Recorder (4 5 slotof 8 TB each), 2 Nos Ethernet port complete with all accessories as per RDSO specno: RDSO/SPN/TC/65/2021 Rev 6.0 or latest. (Inspection by RDSO). Tenderer has to submit STQC (Standardizations Testing and Quality Certification) before supplying materials to SSE/Tele/JDB.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].