Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹46.0 LAccepted-AOC H NO 02 BALLUPUR ROAD DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹47.3 L+₹90,432.20 (1.95%)Rejected-Finance | L-2 | Rejected-Finance Not being lowest bidder | |
| 3 | L-3₹50.1 L+₹3.7 L (8.04%)Rejected-Finance | L-3 | Rejected-Finance Not being lowest bidder | |
| 4 | L-4₹54.7 L+₹8.3 L (17.9%)Rejected-Finance 10 RAJAN KUNJ ROORKEE ROAD MEERUT 250001 | MEERUT | UTTAR PRADESH | 250001 | L-4 | Rejected-Finance Not being lowest bidder | |
| 5 | L-5₹55.8 L+₹9.4 L (20.4%)Rejected-Finance | L-5 | Rejected-Finance Not being lowest bidder |
Tender Value
₹56.7 L
EMD Value
₹1.0 L
Closing Date
19 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE RND Delhi
HQ CE RND Timarpur Delhi-110054
ADDITIONAL/ALTERATION OF NC CENTRE IN BUILDING NO. P100 IN TECHNICAL AREA A AT IRDE, DEHRADUN UNDER GE (I) RnD DEHRADUN
2023_MES_591493_2
CE RND/DLI-03/DDN/2023-24
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE I RND Dehradun
₹1.0 L
Yes
10 Aug 2023
29 May 2023
26 Jun 2023
29 May 2023
19 Jun 2023
5 Jun 2023
Amount
Taking down doors, windows and clear storey windows (steel or wooden), shutter including chowkhats, architrave, holdfasts etc, complete area not exc. 3.0 Sqm of each Window and stacking within 50 metres lead complete all as specified and directed
Taking down aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 metres lead complete all as specified and directed.
M&L for suspended false ceiling system using chicago metallic (E grid)exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length), Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length)with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant, termite resistant , fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip), hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture complete all as specified and directed.. Note:- The point wiring, Light fittings/fixtures shall be measured and paid for separately under respective items of BOQ/Sch A
M&L for providing and fixing Powder coated aluminum (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, complete all as specifed and directed. (Glazing, paneling and dash fasteners shall be measured and paid for separately :
M&L for Powder coated aluminum (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be measured and paid for separately)
M&L for providing and fixing Powder coated aluminum (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators round shape handle of outer dia 100 mm fixed with SS screws etc. complete all as specifed and directed.
M&L for providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete all as specifed and directed.
M&L for providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete of size 100x58x1.90 mm thick complete all as specifed and directed.
M&L for providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity upto 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm)
Taking down doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. area exceeding 3sqm complete and stacking within 50 metres lead complete all as specifed and directed.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. With float/ black glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) complete all as specified and directed. (The aluminum snap beading shall be measured and paid for separately under respective item of BOQ/Sch A)
Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m.
M&L for providing and laying in position cement concrete 1:3:6 (20mm graded crushed stone aggregates all as speicified and directed
M&L for mild Steel work in built up tubular conforming to relevent IS:2062:1984 or latest revision (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes of complete all as specified and directed.
M&L for Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works complete all as specified and directed.
S&F in repair polyster coloured venetian blind mounted on doors / windows with aluminium hanging channel with sliding wheel / rope including all necessary fittings including all necessary fitting as per manufacture instructions and complete all as specified and directed.
M&L for painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work complete all as specified and directed.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by GE) 0.50 mm (+ 0.05 %) total coated thickness with Zink coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required complete all as specified and directed.
Demolition of lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer- in-charge.
M&L for cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete all as specified and directed.
M&L PVC Linoleum 4.5 mm thick, plain coloured, laid dry in floors including stretching, cutting and fitting and laid with approved rubber based adhesive in floors incl removing of old tiles/sheets etc. all as specifed and directed .
M&L for removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete & Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete & Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade Old work (one or more coats) complete all as specified and directed.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed.
M&L for 15 mm thick cement plaster on the rough side of single or half brick wall of Cement mortar mix 1:6 (1 cement: 6 fine sand) complete all as specified and directed.
M&L for providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete and Two coat of Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour complete all as specified and directed.
Demolition of built in CM brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge in cement mortar
M&L for brick work with common burnt clay sub class 'B' of Class designation 7.5 (having minimum compressive strength of 75 Kg per Sq cm) in foundation and plinth in Cement Mortar 1:6 (1 cement : 6 coarse sand) complete all as specified and directed..
M&L for providing and laying in position cement concrete 1:4:8 type D2( using 40 mm graded crushed graded stone aggregate) complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, Light fitting etc and making good disturbed surfaces of existing walls, floors etc. complete all as specified and directed.
Supply and Fix in replacement of unsv light fittings with LED recessed full lit luminaire(2'x2')24 Watt complete with all accessories all as specified and directed.
M&L for light/fan point wiring with 1.5 sqmm FRLS PVC insulated ISI marked copper conductor single core cable in concealed medium class PVC conduits of size not less than 20 mm and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable and repairing the disturbed surfaces With cement sand, mortar etc and paint the repaired surface with the same colour as that of existing wall surface complete all as specified and directed.
M&L for point wiring with 1.5 sqmm FRLS PVC insulated ISI marked copper conductor single core cable in concealed medium class PVC conduits of size not less than 20 mm with modular switch 6 Amp one way, modular socket outlet 6 Amp (ISI marked),blanking plate,modular base and cover plate of 3 module, modular GI box of 3 module and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable,and repairing the disturbed surfaces With cement sand, mortar etc and paint the repaired surface with the same colour as that of existing wall surface complete all as specified and directed.
M&L for point wiring with 2.5 sqmm FRLS PVC insulated ISI marked copper conductor single core cable in concealed medium class PVC conduits of size not less than 20 mm with modular switch 16 Amp one way, modular socket outlet 16 Amp (ISI marked),blanking plate,modular base and cover plate of 4 module, modular GI box of 4 module and earthing the point with 2.5 sqmm FRLS PVC insulated copper conductor single core cable,and repairing the disturbed surfaces With cement sand, mortar etc and paint the repaired surface with the same colour as that of existing wall surface complete all as specified and directed.
M&L for submain wiring of size 2x6 sqmm + 1x6 sqmm earth wire FRLS PVC insulated copper conductor, single core cable in concealed medium class PVC conduit of size not less than 25 mm and repairing the disturbed surfaces with cement mortar 1:4 etc and paint the repaired surface with the same colour as that of wall/surface complete all as specified and directed by Engr-In Charge.
M&L for submain wiring of size 4x10 sqmm + 2x6 sqmm earth wire FRLS PVC insulated copper conductor, single core cable in concealed medium class PVC conduit of size not less than 25 mm and repairing the disturbed surfaces With cement sand, mortar etc and paint the repaired surface with the same colour as that of existing wall surface complete all as specified and directed
S&F Modular switch single pole, one way, 6 amp ISI marked complete all as specified and directed.
S&F 3 pin 5 Amp ceiling rose made of polycarbonate, isolated body including connecting with the junction box complete all as specified and directed.
S&F stepped type modular fan regulator 2 module complete of approved make all as specified and directed by Engr-In-Charge.
S&F modular GI boxes for 12 module in concealed surface alongwith blanking plates, modular base and cover plate of 12 module white in colour and connecting with modular switches and repair the disturbed surfaces With cement sand and mortar etc and paint the repaired surface with the same colour as that of existing wall surface complete all as specified and directed
S&F Single pole and neutral enclosure industrial type with a two pin and earth plug and socket complete with one single pole and neutral MCB 20/32 amp,240Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet complete all as specified and directed.
S&F plug and socket TPN suitable for IP: 30 protection 4 modules (63A 3P+N+E) including fixing with one 'C' curve triple pole neutral 63 Amps MCB complete in all respect all as specified and directed .
Supply and fixing Wall mounting fan single phase oscillating 400 mm sweep complete including Provision of 3 core PVC insulated sheathed 1100 volt grade flexible cable with stranded copper conductor of size not less than 0.5 sqmm including making good the distrubed wall/roof/ceiling etc complete, all as specified and as directed .
Supply,installation,testing and Commissioning of 1200mm sweep, BEE 5 star rated celling fan with BLDC motor, class of insulation:B, 3 nos blades, 30 cm long rod, 2 nos canopies,shackle bit,safety rope, copper winding, power factor not less than 0.9, service value(CM/M/W) minimum 6.00, air delivery minimum 210 Cum/min, 350 rpm( tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts,washers, temp rise=75 degree C max,insulation resistance more than 2 mega ohm suitable for 230V 5 Hz, single phase AC supply, earthing etc complete, all as specified and as directed .
S&F 2 Ton Tower AC cold type, R 410A refrigerant complete with all accessories and connecting the same to plug and socket specified for the same purpose complete all as specified and directed by GE.
S&F vertical type load line distribution board ,double door, 8 way, AC 3 Phase 415 volt with TPN bus bar 200 Amps for each phase with 2 Neutral bar, 2 Earthbar and cable ties for cable management,fully insulted busbar & shrouded Neural bars ,improved Pan assembly for each insullation ,prefitted masking sheeet,reversible door for IP 43-"IK 09 with metal door with provision for DPX3 200 MCCB as incomer and SP/TP MCB's as out going complete all as specified and directed by Engr-in-Charge.
S & F MCCB 4 pole,200 Amps 415 volts, 50 Hz having breaking capacity 36 KA , with adjustable thermal magnetic protection unit and testing Complete all as specified and directed by Engr-In-Charge.
S & F MCB SP 240 volts 'C' Curve,210/415 V, 10 KA breaking capacity suitable for inductive load for fixing in DB of capacity 6 to 32 Amps complete, all as specified and directed by Engr-In-Charge.
S&F isolator TPN 63 amp suitable for degree of protection IP20 lcn 10kA, ISI/CE marked as per IS/IEC 60898 complete all as specified and directed by Engr-In-Charge.
Supplying, Laying, testing and commissioning of XLPE insulated of size 50 sqmm 3½ core,IS 7098 (Part-I)-1988 marked screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 1100V grade cross section area of the under mentioned size of Cables fixed on pole /wall including making necessary connection, with busbar/MCCB/DB's & testing complete, all as specified and directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to 6 SWG galvanized earth wire 4.00 mm dia at 0.5 m below ground level by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish,internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed.
SANJEEV CONSTRUCTIONS
Sree Ram Enterprises
SA construction co.
M/S DEEN ENTERPRISES
Gupta Brothers
M/S DHYANI CONSTRUCTION CO.
Anil Kumar Gupta
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .