| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | ₹4.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹5.6 L+₹1.3 L (29.1%)Rejected-AOC CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | ₹5.6 L+₹1.3 L (29.1%) | L2 | Rejected-AOC Not Being L1 |
| Sl No | Description | Qty | Unit | Singhs Construction L1 | MAHANTA ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, Taking Out and Laying of Cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed. | 18.9 | CUM | 250 ₹4,725 Lowest | 280 ₹5,292 |
| 2.00 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. | 12.46 | CUM | 80 ₹996.8 Lowest | 120 ₹1,495.2 |
| 3.00 | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. | 6.44 | CUM | 120 ₹772.8 Lowest | 150 ₹966 |
| 4.00 | Horizontal Boring for passing GI protection pipe up to 100 mm bore (dia), under road / foot path, not exc. 10.00 metre in a single length, complete all as specified and as directed. | 5 | RM | 650 ₹3,250 | 550 ₹2,750 Lowest |
| 5.00 | M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.
(NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for). | 5.67 | CUM | 750 ₹4,252.5 Lowest | 780 ₹4,422.6 |
| 6.00 | S&F Sub-Class B brick, well burnt, laid breadth-wise along the axis of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed. | 0.56 | Per 1000 Nos | 9,000 ₹5,040 Lowest | 9,000 ₹5,040 Lowest |
| 7.00 | Disconnecting incoming,outgoing and earthing lead connections of transformers,160 KVA, 11 KV /433 Volt supply system,taking down carefully from pole/platform etc from Gym sub station and re-insall at PH 6 including carrying out Periodical Maintenance such as Cleaning of Core and Winding by means of Washing by Hosing Down with Clean Dry Oil to removed Dust/Sludge on Core and Coil, Cleaning of Oil Tank to removed Sludge deposited, Replacement of Rusted Gasket Set, Burnt Spindle, Broken/ Unserviceable HV/LV Ceramic Bushing, Broken Arc Horn, Surge Arrestor, Replacement of Silica Gel, supply and filling of defficient transformer oil filtration to requisite standard and and including reconnection of all incoming outgoing and earthing lead connections,testing and commissioning,complete all as specified and directed. Notes:- (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Rate is deemed to include the spares process not discribed but essential for proper functioning of Transformer | 1 | Each Job | 20,000 ₹20,000 Lowest | 65,000 ₹65,000 |
| 8.00 | Disconnecting incoming,outgoing and earthing lead connections of transformers,315 KVA, 11 KV /433 Volt supply systemtaking down carefully from pole/platform etc from PH6 and re-insall at Gym sub station including carrying out Periodical Maintenance such as Cleaning of Core and Winding by means of Washing by Hosing Down with Clean Dry Oil to removed Dust/Sludge on Core and Coil, Cleaning of Oil Tank to removed Sludge deposited, Replacement of Rusted Gasket Set, Burnt Spindle, Broken/ Unserviceable HV/LV Ceramic Bushing, Broken Arc Horn, Surge Arrestor, Replacement of Silica Gel, supply and filling of defficient transformer oil filtration to requisite standard and and including reconnection of all incoming outgoing and earthing lead connections,testing and commissioning,complete all as specified and directed. Notes:- (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Rate is deemed to include the spares process not discribed but essential for proper functioning of Transformer | 1 | Each Job | 25,000 ₹25,000 Lowest | 65,000 ₹65,000 |
| 9.00 | Supply & Laying or Fixing or Passing through Pipe connecting and testing , XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 95 sqmm 3.5 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. | 90 | RM | 980 ₹88,200 Lowest | 1,010 ₹90,900 |
| 11.00 | M&L for cutting the road/hard standing and making good disturbed surface by using PCC type C2 (1:3:6) by using 20 graded stone aggregate for the fixing the pipe complete all as directed by the Engr-in-Charge at site. | 5 | RM | 450 ₹2,250 Lowest | 480 ₹2,400 |
Tender Value
₹4.8 L
EMD Value
₹10,000
Closing Date
22 Apr 2026, 6:00 pmClosed
CWE AF BORJHAR
AF STN BORJHAR 781015
SHIFTING OF DISTRIBUTION TRANSFORMER FOR ENHANCEMENT OF EXTERNAL ELECTRIFICATION SYSTEM FOR STATION GYM, ASHOKA STADIUM AND KV SCHOOL AT AF STN TEZPUR
2026_MES_758926_1
9131/tez
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
TEZPUR
as per NIT
8 documents required · 8 mandatory
₹300
Yes
GE (AF ) TEZUR
₹10,000
Yes
7 Aug 2026
1 Apr 2026
24 Apr 2026
1 Apr 2026
22 Apr 2026
15 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, Taking Out and Laying of Cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed. | |||||
| 2Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. | |||||
| 3Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. | |||||
| 4Horizontal Boring for passing GI protection pipe up to 100 mm bore (dia), under road / foot path, not exc. 10.00 metre in a single length, complete all as specified and as directed. | |||||
| 5M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for). | |||||
| 6S&F Sub-Class B brick, well burnt, laid breadth-wise along the axis of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed. | |||||
| 7Disconnecting incoming,outgoing and earthing lead connections of transformers,160 KVA, 11 KV /433 Volt supply system,taking down carefully from pole/platform etc from Gym sub station and re-insall at PH 6 including carrying out Periodical Maintenance such as Cleaning of Core and Winding by means of Washing by Hosing Down with Clean Dry Oil to removed Dust/Sludge on Core and Coil, Cleaning of Oil Tank to removed Sludge deposited, Replacement of Rusted Gasket Set, Burnt Spindle, Broken/ Unserviceable HV/LV Ceramic Bushing, Broken Arc Horn, Surge Arrestor, Replacement of Silica Gel, supply and filling of defficient transformer oil filtration to requisite standard and and including reconnection of all incoming outgoing and earthing lead connections,testing and commissioning,complete all as specified and directed. Notes:- (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Rate is deemed to include the spares process not discribed but essential for proper functioning of Transformer | |||||
| 8Disconnecting incoming,outgoing and earthing lead connections of transformers,315 KVA, 11 KV /433 Volt supply systemtaking down carefully from pole/platform etc from Gym sub station and re-insall at PH 6 including carrying out Periodical Maintenance such as Cleaning of Core and Winding by means of Washing by Hosing Down with Clean Dry Oil to removed Dust/Sludge on Core and Coil, Cleaning of Oil Tank to removed Sludge deposited, Replacement of Rusted Gasket Set, Burnt Spindle, Broken/ Unserviceable HV/LV Ceramic Bushing, Broken Arc Horn, Surge Arrestor, Replacement of Silica Gel, supply and filling of defficient transformer oil filtration to requisite standard and and including reconnection of all incoming outgoing and earthing lead connections,testing and commissioning,complete all as specified and directed. Notes:- (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Rate is deemed to include the spares process not discribed but essential for proper functioning of Transformer | |||||
| 9Supply & Laying or Fixing or Passing through Pipe connecting and testing , XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 95 sqmm 3.5 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. | |||||
| 11M&L for cutting the road/hard standing and making good disturbed surface by using PCC type C2 (1:3:6) by using 20 graded stone aggregate for the fixing the pipe complete all as directed by the Engr-in-Charge at site. | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
9131shiftingxmer.pdf
Tender Documents • 0.84 MB
BOQ_850076.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .