Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC | ₹6.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹7.0 LRejected-AOC | ₹7.0 L | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical L3 |
| Sl No | Description | Qty | Unit | MUJEEB RAHMAN E P L1 | SAJI P L3 | PRABEESH T K L2 |
|---|---|---|---|---|---|---|
| 1.00Work | ||||||
| 1.00 | 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | 4,000 | Litre | 8 ₹32,000 | 13 ₹52,000 | 8.82 ₹35,280 |
| 1.00 | OD173535/2024-2025:Dismantling G.I. pipes/PVC pipes ( external work) manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges: all diameter pipes | 60 | metre | 87.6 ₹5,256 | 65 ₹3,900 | 97.04 ₹5,822.40 |
| 1.00 | 15.56:Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | 55.5 | sqm | 37 ₹2,053.50 | 60 ₹3,330 | 41 ₹2,275.50 |
| 1.00 | 15.28.2:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos cement Sheet | 32 | sqm | 52.4 ₹1,676.80 | 70 ₹2,240 | 58.03 ₹1,856.96 |
| 1.00 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 87.5 | sqm | 242.3 ₹21,201.25 | 400 ₹35,000 | 268.31 ₹23,477.13 |
| 1.01 | 22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for
waterproofing treatment to the RCC structures like retaining walls of the basement,
water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels
/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts
integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts
integral crystalline slurry : 1 part water) for horizontal surfaces and applying the
same from negative (internal) side with the help of synthetic fiber brush. The material
shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing
permeability of concrete by more than 90% compared with control concrete as per
DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline
slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work
shall be carried out all complete as per specification and the direction of the engineerin-
charge. The product performance shall carry guarantee for 10 years against any
leakage.For vertical surface two coats @0.70 kg per sqm | 80 | sqm | 333.8 ₹26,704 | 400 ₹32,000 | 369.67 ₹29,573.60 |
| 1.01 | OD173537/2024-2025:Providing and laying vitrified wall tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on gum adhesive excluding grouting the joints etc., complete. Size of Tile 600 x 600 mm. | 50.4 | sqm | 1,530.8 ₹77,152.32 | 1,500 ₹75,600 | 1,695.24 ₹85,440.10 |
| 1.01 | OD173531/2024-2025:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), excluding grouting the joints.Size of Tile 600 x 600 mm. | 31.2 | sqm | 1,155.5 ₹36,051.60 | 1,500 ₹46,800 | 1,279.67 ₹39,925.70 |
| 1.01 | OD173530/2024-2025:Grouting the joints of tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm | 81.6 | sqm | 318.3 ₹25,973.28 | 150 ₹12,240 | 352.52 ₹28,765.63 |
Tender Value
₹8.8 L
EMD Value
₹22,026
Closing Date
4 Nov 2025, 3:00 pmClosed
Assistant Executive Engineer
PWD special buildings sub division , kozhikode
GENERAL Special repair Work Cleaning overhead tank and Laying New pipes at A Block at IMCH attached to Govt Medical College Kozhikode Cleaning work General Civil Work
2025_PWD_815913_1
PWD/BLDG/TR/6825/2024_5_1_1/1
Open Tender
Civil Works - Buildings
240 days
Kozhikode
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,945
Yes
₹22,026
Yes
1 Jan 2026
28 Oct 2025
6 Nov 2025
28 Oct 2025
4 Nov 2025
28 Oct 2025
Amount
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
OD173535/2024-2025:Dismantling G.I. pipes/PVC pipes ( external work) manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges: all diameter pipes
15.56:Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
15.28.2:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos cement Sheet
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
OD173537/2024-2025:Providing and laying vitrified wall tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on gum adhesive excluding grouting the joints etc., complete. Size of Tile 600 x 600 mm.
OD173531/2024-2025:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), excluding grouting the joints.Size of Tile 600 x 600 mm.
OD173530/2024-2025:Grouting the joints of tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
OD173539/2024-2025:Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 10 Kgf/cm2 - External work - Exposed on wall
OD173534/2024-2025:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 10 Kgf/cm2 - External work- Exposed on wall
50.18.9.18.1:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall
50.18.9.20.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow
50.18.9.20.2:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow
50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend
50.18.9.20.5:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee
50.18.9.20.8:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia End cap
50.18.9.20.9:Providing and fixing PVC moulded fitting / accessories for Rigid PVC pipes, including jointing with PVC solvent cement-63 mm dia Socket /coupling
50.18.9.20.10:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer
50.18.9.21:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow
50.18.9.21.10:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x63 mm dia Reducer
50.18.9.21.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend
50.18.9.21.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee
50.18.9.21.8:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap
50.18.9.21.9:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Socket /coupling
50.18.9.16.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall
50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
50.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
50.18.9.22.10:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap
50.18.9.22.11:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling
OD173538/2024-2025:Providing and fixing Zoloto Forged Brass Ball Valve (Screwed) :110 mm nominal bore
14.72:Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .
OD173533/2024-2025:The cleaned reinforcing bar on the dried bar applying corrotion inhibitant one coat of nitozinc primer care should be taken to seethat the zinc primer coated should make an unbroken continous film on the bars. After cleaning the bar applying one coat of bonding agent Nitobond AR/SBR measuement is calculated as in the previous case.including cost of meterials, labour charges, conveyance of materials to site hire charges of tools etc complete.
OD173532/2024-2025::Chipping and removing old spalling/detective concrete and exposing the detective/corroded reinforcement of the ceiling, joint the additional bar wherever 1/3 diameter of the bar is corroded. Removel of the detective concrete across the bar should be at least 2mm beyond the detective bar so that the reinforcing bar can be cleaned with ribbon, wire brush etc. After cleaning the bar wash with clean water and collect all the spalled/ fallen concrete. Measurement is calculated for whole exposed area. Including cost of materials, labour charges, conveyance of materials to site hire charges of tools etc complete.
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
OD199160/2025-2026:Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials from open terrace including loading, transporting, unloading to approved municipal dumping ground within 5 km as per the direction of Engineer-in-charge, for all leads including all lifts involved
OD199188/2025-2026:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 63 mm nominal dia pipes
OD199208/2025-2026:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 80 mm nominal dia pipes
OD199221/2025-2026:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 100 mm nominal dia pipes
OD199634/2025-2026:Providing and fixing Zoloto ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: 63 mm nominal bore
50.12.2.1:Providing & fixing Poly carbonate corrugated sheet 0.8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shapes where ever required.
OD173540/2024-2025:Providing & fixing fly proof wire gauze to windows, clerestory windows and other openings with 25 mm GI square pipe outer frame and applying a priming coat of approved steel primer, including welding as required complete as per the direction of Engineer-in- charge. galvanized M.S. wire gauge of 2mm dia wire and mesh size of 10x10 mm
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
OD173536/2024-2025:Engaging man mazdoor for shifting waste in surroundings
PRABEESH T K (BID ID -2427048)
SAJI P (BID ID -2427619)
Bidder Name
MUJEEB RAHMAN E P
SAJI P
PRABEESH T K
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1366269.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
sbd.pdf
Tender Documents • 1.63 MB
BOQ_1366269.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid