REPAIR/MAINTENANCE OF HT NETWORK HT UG CABLE OVER HAULING AND REPAIR TO TRANSFORMERS WITH GODS FEEDER PILLAR AND INSTALLATION EARTHINGS AT MIL STATION GANDHINAGAR
2021_MES_445898_1
86992
Open Tender
Civil Works - Others
Item Rate
180 days
ARMY AREA GANDHINAGAR
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹62,000
Yes
27 Sept 2021
26 May 2021
16 Jul 2021
26 May 2021
15 Jul 2021
18 Jun 2021
Amount
Excavating in trenches not exceeding 1.5m wide but exceeding 1.5 m in depth for foundation of pole, laying of cables etc in soft/loose soil and getting out.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole, laying of cables etc in soft/loose soil and getting out.
Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm.
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point.
M&L for dry and fine sand filling in trenches below and above the cable for cushioning to underground cable including punning down the sand gently all as specified and directed. Note:- Punninmg thickness only shall be measured and paid
Supplying and laying unreinforced precast concrete cable cover,ISI marked, class HV, type 1 flat, size 300mm x 180mm x 40mm for HT cable and laid dry in trenches over underground cables all as specified and directed.
Disconnecting & taking down 11KV/433 volts unserviceable transformer of capacity upto 100 KVA from two pole structure (From Mily Station Gandhinagar) and transport to civil workshop including opening and dismantling for rewinding / repairing and kept in oven for proper drying of transformer core winding assy etc etc and reassemble after repair and reinstall at same location including replacement of unserviceable nuts, bolts and washers, etc and connecting, testing etc complete all as specified and directed. Note: - (i) The quoted rates shall be deemed to include for cost of crane for taking down transformer and cost of transportation of transformer to workshop and vice versa including all arrangement. (ii) Cost of HT / LT winding and other connected spare parts for repair will be measured & paid separately under respective items of schedule.(iii) Qoated rate deemed to include for dehydration ,filteration and refiiling of Transformer oi,rewinding including testing etc.
Disconnecting & taking down 11KV/433 volts unserviceable transformer of capacity upto 400 KVA from two pole structure (From Mily Station Gandhinagar) and transport to civil workshop including opening and dismantling for rewinding / repairing and kept in oven for proper drying of transformer core winding assy etc and reassemble after repair and reinstall at same location including replacement of unserviceable nuts, bolts and washers, etc and connecting, testing etc complete all as specified and directed. Note: - (i) The quoted rates shall be deemed to include for cost of crane for taking down transformer and cost of transportation of transformer to workshop and vice versa including all arrangement. (ii) Cost of HT / LT winding and other connected spare parts for repair will be measured & paid separately under respective items of schedule.(iii) Qoated rate deemed to include for dehydration ,filteration and refiiling of Transformer oil,rewinfing including testing etc.
Disconnecting & taking down 11KV/433 volts unserviceable transformer of capacity upto 315 KVA from two pole structure (From Mily Station Gandhinagar) and transport to civil workshop including opening and dismantling for rewinding / repairing and kept in oven for proper drying of transformer core winding assy etc and reassemble after repair and reinstall at same location including replacement of unserviceable nuts, bolts and washers, etc and connecting, testing etc complete all as specified and directed. Note: - (i) The quoted rates shall be deemed to include for cost of crane for taking down transformer and cost of transportation of transformer to workshop and vice versa including all arrangement. (ii) Cost of HT / LT winding and other connected spare parts for repair will be measured & paid separately under respective items of schedule.(iii) Qoated rate deemed to include for dehydration ,filteration and refiiling of Transformer oil,rewinding including testing etc.
Supply only rewinding of the core / coil of transformer with mass impregnated copper winding wire of appropriate gauge with thermal class 'E' insulating material and varnishing complete all as per specified and directed.
Supply only, LT bush insulator suitable for 400/315/250/100/63 KVA capacity of transformer.
Supply only, LT bush (rod) spindle of brass complete with washer and nut suitable for existing size and lengths of 400/315/250/100/63 KVA capacity of transformer complete all as per specified and directed.
Supply only HT bush insulator of 11 KV rating for outdoor transformer suitable for 400/315/250/100/63 KVA capacity transformer complete all as per specified and directed.
Supply only HT bush (rod) spindle made out of brass with nut, bolts and washers suitable for 400/315/250/100/63 KVA capacity transformer, complete all as per specified and directed.
S&F, in repair, rubber gasket set 6mm thick for transformer of capacity upto 400 KVA complete all as per specified and directed.
S&F, in repair, GI pipe 100mm dia, light grade, laid below road / fixed along the poles / walls with necessary clamping, etc complete all as per specified and directed.
S&F, in repair, jointing kit for 11 KV (Earthed) grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
S&F, in repair, jointing kit for 11 KV (Earthed) grade cable for Indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
S&F, in repair, jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3core XLPE armoured aluminium conductor cable of size 95 sq mm complete all as specified and directed.
M&L for stay assembly complete with accessories as shown in electrical plate No. 1, complete with galvanised stay strand of size 7/3.5mm with vitreous porcelain loop type insulator, white, brown or green with over all dimension 65x90 mm, clearance of hole16 mm, stay clamps made out of FI 50mmx 6 mm complete with nut, bolts and washer of galvanised iron including excavation & earthwork in any type of soil and concrete work in PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete all as specified and directed and including taking down old stay assembly.
S&F, in repair, pin type porcelain, vitreous, white brown or green insulator including one GI steel spindle, two galvanised iron washer and one galvanised nut 150 mm height, 150 mm dia for 11000 volts grade.
S&F, in repair, disc type porcelain, vitreous, white brown or green insulator including ball and socket type GI steel spindle, two galvanised iron washer and one galvanised nut 145 mm height, 255 mm dia for 11000 volts grade.
S&F, in repair, Gang operated switch, (9 insulator type), Triple pole, mechanically operated, mounted on insulators and steel frame including drop out fuse unit complete with fuse carrier assembly ( set of three ) suitable for 11 KV and with operating mechanism worked from ground level for 11000 volts, 200 Amp rating with operating rod and handle and locking arrangements and connecting up complete all as specified and directed
S&F, in repair, lighting arrester expulsion type complete with all fittings, transmission class suitable for 11000 volts having 65 KA discharge capacity complete all as specified and directed
Dehydration and filtration of transformer oil of the transformer mounted on floor/ on poles using filtration plant. The process of dehydration and filtration shall be continuous till the dielectric strength does not achieved 50 KVfor 2.5 mm gap betbeen electrode . Note: Contractor shall arrange filtration/dehydration machine and other required T&P at site.
Supply & topping up transformer oil confirming to IS 1993 in existing transformer, the di-electric strength not less than 50 KV for a gap of 2.5mm all as specified and as directed by Engineer-in-Charge.
M&L for horizontal boring by using the trenchless technology under the road at least 60 Cm below road top, in any type of soil for insertion of GI pipe of 80mm bore.
S&F steel tubular swaged poles complete with cast iron base plate finial taper plug, bolts, nuts and screws as specified type 410 SP-55 11.00 Meters long complete all as specified and directed
M & L for cross arms, bracing support clamps and back plates etc fabricated from structured steel section including nuts bolts washer welding, bending cold or hot drilling hole for bolts in any shape or size as directed and including applying one coat red oxide primer and two coat aluminium paint after preparation of surface complete including taking down old cross arms etc complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundtion of PCC poles/struts all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work, all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
M&L, in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of 25x4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 25x4mm as earth lead all as specified and testing on completion including provision of earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note for item 42 : Rate quoted by tenderers shall be deemed to include for following provisions;- [i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M. [ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 15 cm C/C both ways with handles. [iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Supplying, laying, connecting, testing, underground XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium multi stranded conductor 11000 volts grade for earthed system, cross sectional area 95 Sqmm x 3 core and taking out of old unsv HT cable any size complete all as per specified and directed.
Retriving of unserviceable under ground HT cable 11 KV XLPE insulated armoured screen PVC bedded of size 3 x 95 sqmm from trenches / wall / duct Note ;- Excavation and earth work to be measured separetely
Laying only serviceable HT UG cable 11 KV 3 x 95 Sqmm armoured XLPE insulated in trenches on wall after jointing
S&F, in repair, Battery backed power packof size 280mm x170mmx130mm for circute breaker of 11KV with pre coated powder coated metal cabinate with lifting handle and panel mounting bracket. The power pack should have the following feature:-(a) AC input voltage 110 V, 50Hz.(b) DC output voltage 24 V.(c) Low input power, to allow powering from the PT for minial burden.(d) Out put capabale for driving "trip" coil with upto 10 repeat impulse of attempts of tripping.(e) Internal SMF battery and auto battery charging, full charge cut off, low battery cut off.(f) Colour indication lamp for main on, Battery mode, battetry low mode, and output over load.(g) DC out put over voltage protection.(h) AC input and DC output protected from over current by externally replaceable fuse.(g) Heavy duty terminal block on the front of the pannel for easy termination for field wiring. (h) Front pannel bettery disconnect switch to avoid battery discharge by in transit.
S&F, in repair, Trip Neutral close switch, complete all as specified and as directed.
S&F, in repair, digital type, Ammeter suitable for 11 KV supply with CT ratio 5A AC.
S&F, in repair, digital type volt meter suitable for 11 KV supply.
Servicing and overhauling of 11 KV VCB by cleaningand lubrication mechanism, panel checking & cleaning of fix and movable contact including setting as per required operation all as directed by Engineer-in-charge.
Checking of CT ratio and breaker tripping by primary injection and calibration of relay and setting of 11KV HT VCB as per required load all as directed by Engineer-in-Charge.
Checking and conducting of High voltage test and setting the relay range of 11KV HT VCB all as directed by Engineer-in-charge
M & L for Painting of steel tubular poles of any size applying two coats of aluminium paint over one coat of red oxide primer to external/exposed surfaces complete all as specified and directed. Note : Writing of Pole number DEEMED TO BE INCLUDED IN QOATED RATE..
Electricals India
Dighard Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .