Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical As per requirement of NIT |
| 2 | Accepted-Technical | Accepted-Technical As per requirement of NIT |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical 321 PATIL NAGAR BAWDHAN ROAD BAVDHAN BUDRUK PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹67.9 L
EMD Value
₹1.4 L
Closing Date
6 Jan 2026, 4:00 pmClosed
EE FTR HQRS SSB Sonapur, Guwahati
FTR HQRS SSB SONAPUR, GUWAHATI, ASSAM
SITC of 15KWp off grid solar power plants in 04 BOPs namely BOP Jamduar, Bongaon, Moulakhola and Dudhikhola under 31st Bn Hqrs SSB Gossaigaon
2025_SSB_890787_1
NIQ No.EE/FTR/GHY/2025/24
Open Tender
Civil Works - Others
Percentage
180 days
BOP Jamduar, Bongaon, Moulakhola and Dudhikhola
As per requirement of NIT
2 documents required · 2 mandatory
₹0
₹1.4 L
FTR HQRS SSB SONAPUR, GUWAHATI, ASSAM
28 Jan 2026
20 Dec 2025
7 Jan 2026
20 Dec 2025
6 Jan 2026
26 Dec 2025
26 Dec 2025
Earth work in excavation ny mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil
Providing and laying in position cement concrete of specified grade excluding the cist of centering and shuttering - All work up to plinth level :1:4:8 (1 cement : 4 coarse sand (zone - III) : 8 graded stone aggregate 40 mm nominal size
Steel reinforcement for R.C.C work including straighting, cutting, bending, placing, in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering includoing strtting, propping etc. and removal of form for:Foundations, footings, bases of columns etc. fore mass concrete
Centering and shuttering includoing strtting, propping etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers ands cantilevers
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:4 (1 cement : 1.5 coarse sand (zone - III) : 3 graded stone aggregate 20 mm nominal size
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7:5 in foundation and plinth in:Cement mortor 1:6 (1 cement: 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7:5 in superstructure above plinth level up to floor V level: Cement mortor 1:4 (1 cement: 4 coarse sand)
Steel work in built up tubular (round, squre or rectangular halloaw etc.) trusses etc., including cutting, hoisting, fixing, in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
Providing and fixing 1mm thick M.S sheet door with franme pf 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners all necessary fittings complete, including applying a priming coat of apprved steel primer.Using flats 30x6mm for diagonal braces and central cross piece
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of bcorrugation as approved by Enginner-in- charges)0.50mm (+0.05%) total coated thickness with zunc coating 120 grams per sqm as per IS: 277, in 240mpa steel grade, 5-7 microns expoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during tranportation and should be supplied in single length upto 12 metre or as desired by Engineer-in Charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5x55mm) with EPDM sdeat, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost iof purlins, rafters and trusses and including cuuting to size and shape wherever required.
12mm cement plaster mix :1:6 (1 cement : 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 fine sand)
Distemping with 1st quality acrylic distemper ( ready mixed) having VOC content less than 50 sqm/litre of approved manufacture and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gm/litre.
Finishing wall with Acrylic Smooth exterior paint of required shade:New work (two or more coats applied @ 1.67 ltr/10 sum over and including priming coat of exterior primer @ 0.90 litre/ 10sqm)
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.71 MB
Tendernotice_2.pdf
PDF • 15.20 MB
Tendernotice_3.pdf
PDF • 2.21 MB
coc2014.pdf
Additional Documents • 7.44 MB
sfy.pdf
Additional Documents • 3.03 MB
BOQ_936300.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .