Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.5 L+₹2.7 L (11.9%)Rejected-Finance MAHAMUNI PARA BOGAFA P S P O SANTIRBAZAR SOUTH TRIPURA | GOMATI | TRIPURA | 799125 | L2 | Rejected-Finance Being L2 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
29 Nov 2021, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR/REPLACEMENT OF WATER SYSTEM, PUMPS, MOTOR, CLEANING OF OH TANK AND UG SUMP AT DARJIPURA AF STN BARODA
2021_MES_479574_2
8669/E8
Open Tender
Civil Works
Item Rate
335 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹50,000
Yes
13 Jan 2022
8 Nov 2021
1 Dec 2021
8 Nov 2021
29 Nov 2021
16 Nov 2021
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying/taking out of cables,CI/GI pipe lines and getting out in sooft/loose soil complete all as specified and directed.
Returning, filling in trenches including spreading, levelling watering and well ramming in layers not exceeding 25 cms in soil all as specified and directed by Engineer-in-Charge.
Removal of excavated material to a distance not exceding 50mtr from starting point and depositing where directed at a level not more than 1.5M above ground level complete all as specified and directed.
Taking out unserviceable CI/GI water main from trenches including fittings / fixtures like bend, Tee, Union, Elbow etc with flanged ends all as specified and as directed for following size of pipes. Note: Excavation and earthwork will be measured and paid separately under appropriate items.
200 mm bore CI pipe
150 mm bore CI pipe
100 mm bore CI pipe
80mm bore CI pipe
80/90 mm bore GI pipe/HDPE Pipe
50/40 mm bore GI/HDPE/PPR pipe
25mm bore GI/PPR pipe
20mm bore GI/PPR pipe
Relaying of old serviceable CI/GI tubing obtained from Srl item No. 04 here-in-before, after cleaning the pipes internally and externally with all fittings laid in trenches, floor, under road, wall, ceiling, floors etc complete all as specified and directed for the following size of pipes:-
50/40mm bore size
25/32 mm bore size
20mm bore GI pipe
Supply and laying Ductile Iron (DI) pipes,with spigot and socket centrifugally cast, class K-7, confirming to IS-8329/2000 in 5.5Mtr length laid in trenches or on supports including making alteration in existing /new pipe line for insertion of new pipe if necessary of following sizes all as specified and as directed.
200 mm bore size
150 mm bore size
Supply and laying Cast Iron pipes,with spigot and socket ends centrifugally cast, class LA, confirming to IS-1536 of 2001 in any length laid in trenches or on supports including making alteration in existing /new pipe line for insertion of new pipe if necessary of following sizes complete all as specified and as directed.
200 mm bore size
150 mm bore size
100 mm bore size
80 mm bore size
Supply and fix accessories, CI specials confirming to IS 1538 (any type radius and angle) such as bends, tapers, straight, increasing / decreasing or double socket / flanged end collars, connecting pieces etc, as required at site suitable for pipe upto 150mm bore complete all as specified and as directed.
Note for item No 6 & 7 : Lead joints and jointing material shall be measured and paid separately under respective items.
Detection of leakage in main water line by necessary excavation in any type of soil, in any situation/depth including bailing out leakage water by suitable measures, repair to CI pipe of following sizes by burning & including lead, spun yarn etc as occuring at Site including cutting, threading for addition & alternation and for insertion of fittings all as required of following sizes:- Note:- (i) Rate quoted shall deemed to be inclusive of necessary excavation/ filling, making good the existing surfaces with the necessary T&P as required all as directed by the Engineer-in-Charge. (ii) CI specials shall be measured and paid separately under respective items.
200 mm bore
150 mm bore
100 mm bore
80 mm bore
Detection of leakage in water main by necessary excavation in any type of soil, in any situation including bailing out leakage water by suitable measures, repair to HDPE/PVC/PPR/GI pipes for the following sizes by cutting, threading for addition & alternation and for insertion of fittings/accessories all as required:- Note (i) The rate is deemed to including fittings/specials as required at site. (ii) Rate quoted shall be deemed to be inclusive of necessary excavation/ filling making good the existing surfaces with the necessary T&P as required all as directed by the Engineer-in-Charge.
25mm bore size
40mm bore size
50mm bore size
65mm/80mm bore size
Supply & laying in trenches/ Walls GI pipe medium grade, ISI marked with necessary GI fittings such as tees, bend, elbows connecting to existing water main all as directed by the Engineer-in-Charge of following sizes:-
20mm bore GI tubing.
25mm bore GI tubing.
40mm bore GI tubing.
50mm bore GI tubing.
80mm bore GI tubing.
Dismantling / Taking down unserviceable Gun metal globe/gate valve and supply and fix new Gun metal globe / gate valve, screwed down high pressure with iron wheel head, screwed both ends for GI/PPR pipe including all fittings / fixtures like nipple, union etc complete for following sizes all as specified and as directed by the Engineer-in-Charge.
50 mm bore size
40 mm bore size
25 mm bore size
20 mm bore size
Supply & fix SS Spindle CI sluice valve 1.6PN, long body, confirming to IS- 14846 : 2000 including dismantling of existing sluice valve complete and testing all as specified and as directed by the Engineer-in-Charge of following sizes:-
200 mm bore sluice valve
150 mm bore sluice valve
100 mm bore sluice valve
80 mm bore sluice valve
Cleaning of RCC under ground sump of following capacity after de-watering and cleaning scrapping with steel brushes/hessin cloths of the sump walls from inside including floor of the sump complete and repair to vent pipes including providing wire mesh and clamps complete all as directed by Engineer-in-Charge. Note: If work is not done upto satisfaction level of concerned JE/AGE (E/M) , the work will be redone upto the required level without any extra cost. Necessary tools and safety measures to be arranged by contractor.
15000 Gallon
20000 Gallon
50000 Gallon
100000 Gallon
M & L for cleaning of Overhead tank of following capacity by scratching and cleaning inside walls,pillars and floors with bleaching powder and clean water including taking out dirt, mud from storage tank including stacking at site and removal to out side MD land and repair to vent pipes including providing wire mesh to cover all air gap holes and clamps complete all as directed by Engineer-in-Charge. Note: If work is not done upto satisfaction level of concerned JE/AGE (E/M) , the work will be redone upto the mark without any extra cost. Necessary tools and safety measures to be arranged by contractor.
20000 Gallon
35000 Gallon
50000 Gallon
75000 Gallon
M & L for mild steel framed work as in doors or gates of angle iron section of size 40X40X5mm or other section with gasket plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete with locking arrangement all as directed. (Under ground Sump)
M & L for Mild steel, plain, black sheet 1.6mm thick in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up and welding handle for lifting, mitred angles, etc. as required complete all as directed.
M&L Run Lead joints for CI pipe spigot and socketted pipes and fittings confirming to IS-12820-1989/IS5382-1985 , for following bores of pipes with and including Lead and spunyarn as suitable for pipe complete all as specified. (For new pipe length)
80 mm bore size
100 mm bore size
150 mm bore size
200 mm bore size
Supply and fix good quality PVC saddles including all necessary T & P such as heater for joint, threading etc all as directed by Engr-in-Charge including dismantling existing unserviceable/ broken PVC saddles for the following sizes:-
upto 25mm bore size
32 mm bore size
65 mm bore size
Supply & laying in trenches/ Walls 40 mm High density poly?ethylene pipes (HDPE) of pressure rating 6 kgf/cm2(PN-6) laid in trenches, connecting to existing water maincomplete all as specified and directed
All as per item No.20.00 above but 50mm bore GI tubing.
All as per item No.20.00 above but 90mm bore GI tubing.
Supply and fix PPR pipes ISI marked of type PN16/SDR 11- 3 layer with fittings including taking down existing unserviceable pipes complete all as specified and directed OF following Sizes
20 mm bore size
25 mm bore size
40 mm bore size
50 mm bore size
Supply and fix Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe 0f ISI marked with fittings including taking down existing unserviceable pipes complete all as specified and directed for the following sizes:-
20 mm bore size
25 mm bore size
32 mm bore size
40 mm bore size
50 mm bore size
Detection of leakage in main water line by necessary excavation in any type of soil, in any situation/depth including bailing out leakage water by suitable measures, repair to CI pipe of 200mm bore by burning & including lead, spunyarn etc as occuring at Site including cutting, threading for addition & alternation and for insertion of fittings all as required. (for Main Line from Jakatnaka)) Note:- (i) Rate quoted shall be deemed to be inclusive of necessary excavation in hard/dense soil to a depth exc 1.50m and n.exc 3.5m including necessary returning filling, removal of soil, draining of water if any and making good the existing surface all as directed by the Engineer-in-Charge.(for Main Line from Jakatnaka)
Supply and fix foot valve PP conforming to relevant IS complete of following sizes :- Make-Normax/Perth
80 mm bore size
100 mm bore size
Taking out existing unservicable submersible pump set 3 HP electric driven and lowering (after repair) to borewell after repairs any depth complete all as specified and directed. Note:-1 If submersible pump drops in borewell during taking out, contractor is responsible to take out the submersible pump by any arrangement at his own cost .2. Supply and fix in repair of following parts for existing submerisble pump set electric driven 3 phase 415 volt 3 to 5 HP :-
Thrust bearing with thrust plate complete.
Top and bottom thrust bearing housing
Gun metal impellar with bush and neck rings, keys.
Pump shaft
Submersible cable multistranded copper conductor Flat of size 2.5 sqmm 3 core.
M & L for rewinding of borewell submersible motor of 3 to 5 HP with PVC insulated submersible rewinding wire of suitable gauge/size as per existing incliding rotor balancing testing and connection of submersible cable and cable gland including taking down old winding wire complete all as specified and directed.
Taking out existing unservicable openwell submersible pump set up to 1 HP and lowering(after repair) to water storage sump complete all as specified and directed.
M & L for rewinding of openwell submersible motor 1 HP with PVC insulated submersible rewinding wire of suitable gauge/size as existing including rotor balancing, testing and connection of submersible cable and cable gland including taking down old winding wire complete all as specified and directed.
M & L for rewinding of monoblock/ Centrifugal pump (Motor), 3 phase, 415 volt with supper emamelled copper rewinding wire of suitable size/gauge as existing and providing insulation varnishing, heating, testing including taking out the existing winding wire complete all as required for completion of JOB for following capacity pumps:-
Motor of capacity 50 HP
Motor of capacity 40 HP
Motor of capacity 25 HP
Motor of capacity 12.5 HP
Motor of capacity 7.5 HP
Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 50/40 HP having discharge 400 LPM at 990 mtr head.
Motor bearing .
Motor cooling fan
Pump motor MS coupling
L-190 spider.
Cover bolts & washers
Pump bearing No. 6307 of Make : SKF/UBC/TATA/FAG/ NBC
CI impellar DB 80/20 for existing 50/40 HP centrifugal pump set.
CI Gland packing chaplla
SS Sleeve (Gland Sleeve)
Pump shaft with studs and nuts for pump body.
Starter relay of Make : Jyoti, Range 36-60
Magnet coil of Make Jyoti.
Starter copper contact set
Starter oil.
Starter base plate
Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 25 HP.
Motor cooling fan
Pump motor MS coupling
L-190 spider.
Cover bolts & washers
Pump bearing Make : SKF/UBC/TATA/FAG/ NBC
Motor bearing of Make : SKF/UBC/TATA/FAG/ NBC
CI impellar suitable for existing pump set.
CI Gland packing chaplla
SS Sleeve (Gland Sleeve)
Pump shaft with studs and nuts for pump body.
Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 12.5/7.5 HP
Motor cooling fan
Pump motor MS coupling
L-190 spider.
Cover bolts & washers
Pump bearing Make : SKF/UBC/TATA/FAG/ NBC
Motor bearing of Make : SKF/UBC/TATA/FAG/ NBC
CI impellar suitable for existing pump set.
CI Gland packing chaplla
SS Sleeve (Gland Sleeve)
Pump shaft with studs and nuts for pump body.
Supply and fix in repair star delta starter of following capacity all as specified and directed.
For 50/40 HP motor
For 25 HP motor
For 12/7.5 HP motor
Supply and fix in repair of submersible pump motor starter of 5 HP as suitable at site complete all as specified and directed.
M&L for oiling and greasing of pump motor parts (any make any size) by means of greasing gun or manually by unbolting and separating the pump motor set complete for smooth operation of machinery, making it leakage free and applying gland packing of necessary quantity and making working complete noise and leakage free all as directed. Note: (a) Rates for greese,lubricating oil and galnd packing deemed to included in quoted rates. (b) Pump motors measured under this item will be saperate and not to be included in any other item above.
Supply and fix CI/DI air valves with two air outlets, conforming to IS 14845 of size 200 mm dia and fixing up in CI/DI water supply mains including excavation complete all as specified and directed
Supply and fix single phase preventor suitable for 3 phase motor of any make any size complete as per sample and all as specified and directed.
S&F in repair contactor 4 pole with AC coil 415 volt 50 Hz, 25 Amp for motor starter complete all as specified and directed.
S&F in repair overload and single phasing relay suitable for 15-25 Amp for motor starter panel 415 V, 50 Hz capacity complete all as directed by Engineer-in-Charge. Make- L&T or equivalent as approved.
S&F in repair sencer system of pressure booster pump of 1 HP including testing on ground complete all as specified and as directed.
S&F in repair of aviation LED light fitting suitable for overhead tank with 1.5 sqmm 2 core cable 20 meter for connetion and nuts, bolts, clamps all as specified and directed.
Supply & provide Aquafit (Calcium hypo chlorite) 65% - 70% chlorine content (Calcium based granular desinfectant for water treatment plants much more stable than chlorine gas & stronger than bleaching powder and sodium hypo chlorite packed in 45 Kg drum complete all as specified and directed. Make : Auafit & Equivalent.
Supply of water through tanker/bouser for domestic use including transportation from source to U/G sump Darjipura Afs Baroda. The water should have the following main factors :- (a)Water should be clear and from all suspended matters both Hyganic & inorganic matter. (b) Water should be free from taste and odour. (c) Water should be colour less and no vegetable stain should be present. (d) Water should be soft that it should not contain dissolved impurities like calcium or magnesium bicarbonate and Sulphates. (e) Water should be soft and should be free from all pathogenic organism causing diseases. (f) Copy of gate entry at guard room with vehicle No date and time shall be submitted duly defaced by Engr in charge before claiming payment. Note : Water analysis duly tested by authorised lab will be rendered by supplier before supplying the water.
M & L for Unplasticised PVC ball/gate valve, high pressure with PVC handel for UPVC/PPR pipe including all fittings / fixtures like nipple, union etc with Dismantling / Taking down unserviceable complete for following sizes all as specified and as directed
20 mm bore size
25 mm bore size
32 mm bore size
40 mm bore size
Labour only for opening the cover plate of sluice valve of any size for cleaning inside to check blockage and refixing the same on existing position complete all as specified and directed.
Material and labour for replacement of centrifugal pump motor foundation including angle iron frame of existing size and model, breakin existing PCC foundation and making new foundation with grouting appropriate size foundation bolts for bressing iron frame including refixing of pump motor and testing omplete all as specified and directed.
M & L for fixing of horizontal priming pump of 1HP 220 Volt 1 phase including 2.5 sqmm 2core pvc cable of 50Mtr long at main pump house Sump with necessary arrangement complete all as specified and directed.
BHARAT NIRMAN INFRASTRUCTURE COMPANY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .