| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹25.3 L+₹15,838.50 (0.63%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹25.9 L+₹76,480 (3.04%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹27.1 L+₹1.9 L (7.71%)Rejected-Finance 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹29.0 L+₹3.8 L (15.1%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹62,400
Closing Date
7 Jun 2023, 6:00 pmClosed
CWE Ambala
Headquarter Commander Works Engineer Ambala Mansfield Road Ambala Cantt
PROVN OF 01 X ROOM FOR BLOOD COMPONENT PREPARATION APHERESIS ADJACENT TO BLDG NO. 118 (BLOOD BANK) AND TOILET BLOCK IN-FRONT OF MI ROOM FOR PATIENT OF MH AMBALA UNDER GE(SOUTH) AMBALA CANTT
2023_MES_590756_1
CWE/AMB/SOUTH-07 OF 2023-24
Open Tender
Civil Works
Lump-sum
180 days
Ambala Cantt
All as per tender documents
9 documents required · 9 mandatory
₹500
GE SOUTH AMBALA CANTT
₹62,400
Yes
28 Jun 2023
21 Apr 2023
9 Jun 2023
21 Apr 2023
7 Jun 2023
26 May 2023
21 Apr 2023 - 24 May 2023
Amount
Schedule 'A' Section-I to Section-IX (BOQ Item No 1.01 to 1.09 here-in-after) (PREPRICED BY MES). These schedules are prepriced by MES and Prepriced rates indicated under column-5. Bidders to quote there rates under Column-6 only .
Schedule 'A' Section-I (Building works)
Schedule 'A' Section-II (Internal Water supply works)
Schedule 'A' Section-III (Internal Electrification works)
Schedule 'A' Section-IV (Road/ Path pavements works)
Schedule 'A' Section-V (Sewage Disposal works)
Schedule 'A' Section-VI (Area drainage works)
Schedule 'A' Section-VII (External Electrification works)
Schedule 'A' Section-VIII (External Water supply works)
Schedule 'A' Section-IX (Earth works)
Schedule 'A' Section-X (Miscellenous item of works) (Item No 2.01 to 2.03 here-in-after) (to be priced by bidders). Bidders to quote there rates under Column-6 only .
S&F air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, with cooling and heating suitable to operate 230 volts, AC supply BEE 5 star rated inverter technology complete all as specified and directed.
S&F wall mounted voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5KVA copper wound complete all as specified and directed.
Supply and fixing sheet metal enclosures vertical distribution board VTPN, (MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole, 63 Amps 16 KA as incomer and MCBs as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including taking down the existing DB and MCBs any type and making connection with suitable size of lugs and making good the disturbed surface matching with existing surface all as specified and directed. Note:- MCB shall be measured and paid separetely.
S M BUILDERS
M/s Kang Builders
KULWANT SINGH
M/S SHASTRI BUILDERS AND ENGINEERS
Gupta Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .