Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | ₹35.2 L Quoted ₹39.0 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹41.0 L+₹2.0 L (5.09%)Rejected-Finance | ₹41.0 L+₹2.0 L (5.09%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹46.5 L+₹7.5 L (19.2%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | ₹46.5 L+₹7.5 L (19.2%) | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹78,000
Closing Date
22 Feb 2022, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
SPECIAL REPAIRS TO BUILDING NO. P-92 AT NAVAL BASE OKHA UNDER GE NAVY PORBANDAR
2022_MES_503819_1
8794/Okha/E8
Open Tender
Civil Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹78,000
Yes
9 Mar 2022
25 Jan 2022
24 Feb 2022
25 Jan 2022
22 Feb 2022
9 Feb 2022
26 Jan 2022 - 8 Feb 2022
Amount
Dismantling structural steel work including rolling shutters doors, gates but excluding framed truss complete as specified and directed.
Taking down chowkat or frames exc 1.5 Sqm and n.exc 4 Sqm each with shutter (without taking off Shutter) complete all as specified and as directed.
Taking down cement plaster of any description incl raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
S&F Mechanically operated mild steel rolling shutters with partial Grill type for opening size 4.50x6.00 mtr made out of following (i) Curtain/Lath - 1.20mm thick and 75mm wide interlocked (ii) Lock Plate - Riveted construction with MS Plate not less than 3.15mm thickness reinforced with mild steel section 35x35x5mm with handles of 3 Nos and locking arrangement (iii) Guide Channels - Mild 3.15mm thick and 75mm deep MS dowel section (iv) Bracket Plate - Mild Steel plate not less than 6mm thick in hexagonal/Square/Round in shape and firmly arrangement to wall (v) Roller - 50mm sizes of pipes heavy duty (nominal bore) for suspension shaft. The suspension shaft shall be provided with steel or preferably cast iron pulley and helical wire spring or flat spiral springs for counter balancing the weight of the shutter adequately. The pulley shall be interconnected with a cage formed out of MS flats of at least 32x6mm and MS dummy ring made of similar flats. The caging ring shall have a min spacing of 15cm and there shall be at least 4 Nos. flats running throughout the length of the roller. (vi) Hood Covers - Hood covers shall be made of mild steel sheet 1.0mm thick. The cover shall be properly stiffened with angle/flat stiffeners at top and bottom edges. The hood covers shall be fixed to the bracket plate.
(vii) Wicket Doors - Where indicated, wicket door of 900x1800mm size. The wicket door shall be of robust construction and shall be fitted with a good lever lock operated by key, lockable both from inside and outside. The wicket door shall be swing clear of the opening before the rolling shutter is raised or lowered. (viii) Rolling Grill - rolling grill portion at top bottom and middle places as indicated. The height of grill portion shall be maximum of 0.5m. Rolling grill shall be built of cold rolled steel sheet links of 0.9mm thickness assembled on tubes or rods. Grill may also be manufactured out of 8mm dia MS round bars. Note: Making good of demolished and making to nature with the adjacement also shall be cleaned.
Safety lever locks mild steel with 4 levers for rolling shutters complete all specified and directed.
Preparation of new steel surfaces of any description not other wise described over 10cm width or girth and applying two coats of anti corrosive paint over a coat of anti corrosive primer complete all specified and directed.
Rendering 15 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:4 finished even and smooth without using extra cement including mixing Integral Water proofing treatment (where ever required as directed by Engineer in charge) complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately).
Rendering 15 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Rendering 10 mm thick on fair faces of brick work or concrete surfaces as on ceiling surface, facia and projection of slabs, and window projection, in CM 1:3 finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
Powder coated aluminium anodised frame and shutter for doors, windows and partitions with one or more rebates including necessary joining cleats, glazing clips, rubber neoprene packing, handle, stoppage, locking arrangements etc complete with powder coating of approved colour minimum thickness 50 micron complete all as specified and directed.
4.8 mm thick Sheet glass,ordinary quality and glazing with Aluminium snap beading with rubber Neoprene packing in square exc 0.5 sq. m in each pane complete all as specified and as directed.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples fixed in repairs complete all as specified and as directed.
20mm thick Granite of Ist quality, table rubbed and polished, as in window cills, jambs, pillars or steps and the like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including 15 mm thick rendering in cement mortar 1:4, including grinding and polishing, complete all as specified and as directed.
Preparation of old decorated surfaces of walls and applying one coat of white wash complete all as specified and directed.
Preparation of old decorated surfaces of ceilings and applying one coat of white wash complete all as specified and directed.
Complete removal of existing treatment, preparation of surfaces of walls and applying one coat of wall care putty and applying two coats of weather proof Acraylic based exterior emulsion paint over over a coat of self primer (100% Acraylic) complete all as specified and directed.
Preparation of newly plastered surfaces of walls, soffits & facias roof and applying two coats of weather proof Acrylic based exterior emulsion paint over a coat of self primer (100% Acraylic) complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light/fan, buzzer, socket or power point etc) complete including all fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc including making good the disturbed surface to match with the existing all as specified and directed by Engineer-in-charge.
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for the following:- One light or fan point controlled by one one way switch
All as per above item No. 22 but 5 Amps switch socket on same board.
Point wiring with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for independent switch socket outlet 6 pin 5/15 Amps complete all as Specified and directed by Engr-in-Charge.
Taking down sub main wiring and making good disturbed surfaces of wall / floor complete all as specified and as directed.
Sub main wiring concealed with two runs of single core 6 Sqmm (Nominal area) cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including one run of 6sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (PVC Conduit shall be measured and paid separately).
20 mm rigid non-metallic PVC concealed conduit medium grade including all PVC conduit accessories, cutting / chases and making good disturbed surfaces complete all as specified and directed.
Modular switch 1 way 6 Amps, 1 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Modular switch 1 way 16 Amps, 1 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Modular socket 6A, 2/3 pin combined, 2 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Modular socket 16A, 2/3 pin combined, 2 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Ceiling rose surface bakelite 65x50mm 3 terminal fixed in repair / replacement complete all as specified and directed.
Modular white cover plate suitable for 1 modules with frame fixed in repair / replacement complete all as specified and directed.
Modular white cover plate suitable for 3 modules with frame fixed in repair / replacement complete all as specified and directed.
Modular white cover plate suitable for 8 modules with frame fixed in repair / replacement complete all as specified and directed.
Modular white cover plate suitable for 12 modules combined plate with frame fixed in repair / replacement complete all as specified and directed.
Modular surface mounting plastic boxes suitable for 12 modules combined plate-Coral fixed in repair / replacement complete all as specified and directed.
Modular surface mounting plastic boxes suitable for 8 modules combined plate-Coral fixed in repair / replacement complete all as specified and directed.
Taking down DB/Main switch of any size making good disturbed surface of wall / floor complete all as specified and directed by Engineer-in-charge.
MCB DB Single pole and neutral 8 way double door fixed in repair / replacement complete all as specified and directed.
MCB DB Single pole and neutral 12 way double door fixed in repair / replacement complete all as specified and directed.
MCB SP 240 Volts AC 6 - 32 Amps of breaking capacity 10 KA C curve, fixed in repair / replacement complete all as specified and directed.
MCB SPN 240 Volts AC 40 Amps of breaking capacity 10 KA C curve, fixed in repair / replacement complete all as specified and directed.
MCB SPN 63 Amps, 10 KA breaking capacity , C Curve suitable for 230 V, 50 Hz AC Supply, fixed in repairs, complete all as specified and directed by Engineer - in - Charge.
E-LITE LED PRIDE PLUS 18 Watt 6000 K Decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient complete with duly prewired and connecting fixed in repair / replacement complete all as specified and directed by Engineer - in - Charge. Make:-Havells Cat no:- LHEXBLP7PN1W018 or its equivalent model of Philips/Wipro or as specified here-in-before.
DBOXX SRCD Protected Socket (With Steel Enclosure) MCB SPN 25 Amp rating,240 Volts with sheet steel enclosure in ready plug & play all-in-one device that provides protection to humans from electric shock due to direct or indirect contact as well as provides protection from overload and short circuit faults complete all as specified and directed by Engineer - in - Charge. Make :- Havells cat No :- DHDDCDP025202503 or its equivalent model HPL/C&S or as specified here-in-before.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Galvanised earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 15mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion complete all as specified and directed.
Taking down Building security light Fitting/flood light/Tube light fitting of any type & size and making good disturbed surface of wall/floor complete all as specified.
Building street light fitting Endura pearl 20W LED lamp new genaration energy saving & environmental friendly long life made up of pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP65 protection and impect resistance of IK07,with suitable of GI pipe (light grade) bracket and clamps,nut bolts are fixed on wall/post fixed in repair / replacement complete all as specified and directed. Make Havells cat no ENDURAPEARLSL20WLED757SASYTOPC or equivalent cat part of makes specified here-in-before.
Amaze flood light LED luminaire white120 watt IP -65 flood light with highlighting architecturel facade highmast light fixed in repair / replacement including taking down the u/s street light fittingscomplete all as specified and directed. Make :Bajaj Cat No :- BJFL 60 LED I or its equivalent model of Havells/CG or as specified here-in-before.
TPN Distribution board double door prewired with Cable End Box incomming 8 way and out going 12 way with including MCB TPN 63 Amp-01 No and RCBO 63 Amp -01,MCB TPN 32 Amp - 03 Nos fixed on wall complete all as specified and as directed by Engr-Iin-Charge. Make :Havells Cat No _ DHDMTHMLXW04 or its equivalent model of Anchor/HPL or as specified here-in-before.
Supply and fixing of automatic Rolling Shutter Motor stainless steel, single phase 220 to 240 volts, 50-60 HZ remote control operated,suitable of operating capacity upto 500 kg and upto 7 meter height of rolling shutter complete all as specified and as directed by Engr-in-Charge.
Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (Heavy duly) with stranded aluminium conductor cross sectional area 16 sqmm 2 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe and protection clamps shall be measured and paid for separately.
Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (Heavy duly) with stranded aluminium conductor cross sectional area 10 sqmm 2 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe and protection clamps shall be measured and paid for separately.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, pipe line, cable, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm deep as in soil complete as specified.
Removing excavated material (soil/ rock) to distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point,complete all as specified and directed.
Fine dry river sand cushion in trenches for cable protection with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Note :- Only compacted thickness will be measured and paid.
Precast concrete cable cover unreinforced, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200KG, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
GI tubing light grade ISI marked for cable protection at road crossing/floor/wall/ on poles or at any indicated situation etc duly sealed at both end after drawing cable including necessary clamps, saddles all as directed and specified for 50 mm bore complete all as specified and directed.
Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (Heavy duly) with stranded aluminium conductor cross sectional area 35 sqmm 3.5 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe and protection clamps shall be measured and paid for separately.
BABUBHAI BHIMABHAI PANDAVADRA
JAY BHARAT METAL SUPPLIERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .