Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.9 L+₹1.4 L (5.15%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹30.0 L+₹2.5 L (9.12%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹30.2 L+₹2.7 L (9.98%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹32.5 L+₹5.0 L (18.3%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Aman Bhardwaj
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No.1 Jamnagar 361 003
REPAIR/MAINTENANCE OF HANGER/TARMAC LIGHTS AT TECH AREA UNDER GE (AF) JAMNAGAR NO 1
2023_MES_602131_1
8236/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jamnagar No. 1
Please refer Tender Documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No. 1
₹70,000
Yes
14 Aug 2023
9 Jun 2023
6 Jul 2023
9 Jun 2023
5 Jul 2023
28 Jun 2023
Amount
Taking down carefully aluminum/copper flame proof point wiring complete of any type (surface ERW conduit for light point, fan point, or power point complete with all fitting such as rotary switches, sockets, fan regulators etc complete and making good disturbed surfaces complete all as specified and directed.
Taking down carefully flood light/high bay light fittings of any description from existing position from Hanger/tarmac complete all as specified & directed by Engineer in charge
Taking down old sub main wiring including rigid steel conduit with all accessories and removing to and making good disturbed surfaces.
Material & Labour for point wiring for one light point controlled by one flameproof switch, complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen) cable 1100 volts grade ISI marked drawn and including mild steel ERW conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH cable as a earth wire connected to common earth dolly, etc complete all as specified and directed.
All as per item No 04 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke & Halogen, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch complete all as specified and directed.
Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class 'B' (ISI Marked) not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete. Note: 2 Runs of main cable and one run earth wire with ERW conduit will be measured as one Unit for payment.
Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class 'B' (ISI Marked) not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete. Note: 2 Runs of main cable and one run earth wire with ERW conduit will be measured as one Unit for payment.
Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class 'B' (ISI Marked) not less than 25 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete. Note: 2 Runs of main cable and one run earth wire with ERW conduit will be measured as one Unit for payment.
Material & Labour in repair for sub main wiring with 4 run single core multistranded copper conductor cable of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class 'B' (ISI Marked) not less than 25 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete. Note: 4 Runs of main cable and one run earth wire with ERW conduit will be measured as one Unit for payment.
Supply and erect in replacement Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 Note:- (a) Rate quated is inclusive of following (i) Excavation&Earthwork ,Returning filling and Removal of soil (ii) PCC (1:3:6) type c2 as per specification (iii) Coping (1:2:4) type b1 as per specification.
S&F in repairs Cross arms (ISI Marked), bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint.
S&F in replacement of LED flood Light fitting 200 Watt, system efficiency not less than 100 lumen / watt, IP 66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete. Make :-cat no. JETAVALOURFL200WLED757PINTNBLTG of Havells OR equivalent of crompton/philips/wipro/syska/C&S electric/HPL electric & power Ltd/HELONIX TECHNOLIES.
S&F in replacement of LED flood Light fitting 240 Watt, system efficiency not less than 100 lumen / watt, IP 66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete. Make :-cat no.JETAVALOURFL240WLED757MODWBLTG of Havells OR equivalent of crompton/philips/wipro/syska/C&S electric/HPL electric & power Ltd/HELONIX TECHNOLIES..
S&F in replacement of LED flood Light fitting 120 Watt, system efficiency not less than 100 lumen / watt, IP 66 protection, IK 07 impact resistance, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete. Make :- cat no. JETAIRISFLS120WLED757SYMLTG of Havells OR equivalent of crompton/philips/wipro/syska/C&S electric/HPL electric & power Ltd/HELONIX TECHNOLIES.
S&F in replacement of LED flood Light fitting 160 Watt, system efficiency not less than 100 lumen / watt, IP 66 protection, IK 07 impact resistance, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete. Make :- cat no. JETAIRISFLS160WLED757PNBLTG of Havells equivalent of crompton/philips/wipro/syska/C&S electric/HPL electric & power Ltd/HELONIX TECHNOLIES.
S&F in replacement of Sheet moulding compound (SMC) junction box of size 350 mm x 200 mm x 150mm, comprising three phase aluminium bus bar and one No MCB SP, 06 Amps "C" type, fixed on pole with mild steel clamps, nuts and bolts complete. Make:-Sintex/Legrand/Siemens/EPP composite Pvt Ltd.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting outin Hard/dense soil.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick using excavated soil all as directed
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for providing dry river sand as in sand cushioning to under ground PVC cable including punning down of sand in layer all as specified and directed. (Note: Work shall be executed as per clause 19.75 of standard schedule of rates part-1 (2009) for measurement purpose thickness of sand after punning down will be considered.)
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 10 sqmm 2 /4 core including cable cover all as specified and directed.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 16 sqmm 4 core including cable cover all as specified and directed.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 25 sqmm 3.5 core including cable cover all as specified and directed.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 10 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
S&F in repair PVC insulated, 2 core 2.5 Sqmm round sheathed copper conductor(flexible) industrial cable fire retardant all as specified and directed.
S&F in repair PVC insulated, 2 core 10 Sqmm round sheathed copper conductor(flexible) industrial cable fire retardant all as specified and directed.
Laying only PCC cable cover for LT UG cable, of any description retrieved from item No.22 to 24 all as specified and directed.
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed.
Supply and fixing in replacement MCCB DB of 415 Volts, 4 way, with double door sheet metal enclosure for fixing TPN DB-VTPN as per IEC 61439-3 and reversible Door for IP 43 & 54 with 250 Amps rated copper busbar for each phase with 2 neutral busbar, 2 earthbar with provision for MCCB as incomer (without MCCB ) and provn for SP/TP MCBs as outgoing(without MCBs) on flush to the wall including making hole in the wall and fixing the DB including cement work and plastering complete all as directed Make: Havells Cat part DHDLVDRWGOF004 or equivalent of makes as in APPENDIX "B"
Supply and fixing in replacement MCCB triple pole and neutral , DPX3 thermal magnetic capacity of 100 Amps,415 V and 16KA Short Circuit Breaking Capacity.
Supply and fixing in replacement sheet metal enclosure for fixing MCBs TPN with 200 Amps rated neutral busbar 415 Volts, 4 way, with double door fixed flush to the wall including making hole in the wall and fixing the DB including cement work and plastering complete.
S&F in replacement Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified and directed.
Supply and fix in replacement MCB’s single pole, 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix in replacement MCB’s single pole & neutral, 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix in replacement MCB’s single pole & neutral, 40 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix in replacement MCB’s triple pole and neutral, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix in replacement MCB’s triple pole, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10amp complete all as specified and directed.
Supply and fix in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20amp complete all as specified and directed.
Supply and fix in replacement of Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amp complete all as specified and directed.
Supply and fix in replacement of Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 63 amp complete all as specified and directed.
Material and labour for renewal of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Note : The Quoted rate for above item includes the cost of following : - (a) Earth electrode. (b) Main earthing lead from earth electrode to test point of 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust, common salt and adequate quantity of chemical (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode.
(g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. (k) Test point. (l) Connecting lead from test point to main
Sukhi Electricals
SURESH ELECTRICALS
High Tech Consruction
rajengineers
jagdish machinery stores
JAYESH TRADING CORPORATION
Nitesh Enterprise
Vijay Construction Co
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .