Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAccepted-AOC A 31 RAJENDRA NAGAR BAREILLY UP 243122 | BAREILLY | BAREILLY | UP | 243122 | ₹3.4 Cr | L1 | Accepted-AOC AWARDED SINCE L1 |
| 2 | L2₹3.7 Cr+₹34.0 L (10.0%)Rejected-Finance 160 PREM NAGAR BAREILLY | ₹3.7 Cr+₹34.0 L (10.0%) | L2 | Rejected-Finance REJECTED SINCE NOT L1 |
| 3 | L3₹4.2 Cr+₹81.1 L (23.9%)Rejected-Finance 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | ₹4.2 Cr+₹81.1 L (23.9%) | L3 | Rejected-Finance REJECTED SINCE NOT L1 |
| 4 | L4₹4.6 Cr+₹1.2 Cr (35.4%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹4.6 Cr+₹1.2 Cr (35.4%) | L4 | Rejected-Finance REJECTED SINCE NOT L1 |
Tender Value
₹4.5 Cr
EMD Value
₹5.2 L
Closing Date
24 Dec 2019, 6:00 pmClosed
CE AF ALLAHABAD
HQ CE AF ALLAHABAD 211012
PROVISION OF CERTAIN WORKS SERVICES IN WEAPON STORAGE AREA (WSA) AT AIR FORCE STATION BAREILLY
2019_MES_282543_1
958795/E8
Open Tender
Civil Works
Item Rate
548 days
GE (AF) Izatnagar Bareilly
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) Izatnagar Bareilly
₹5.2 L
Yes
18 Jan 2020
16 Sept 2019
30 Dec 2019
16 Sept 2019
24 Dec 2019
9 Dec 2019
23 Sept 2019 - 30 Sept 2019
Amount
Excavation over areas, not exceeding 1.5m deep and getting out in hard /dense soil complete all as specified and directed.
Excavation over areas, exceeding 1.5m deep and not exceeding 3.0 mtr deep and getting out in hard/dense of soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified & directed.
Excavation in trenches in soft / loose soil n exc 1.5 Mtr wide and n.exc 1.5 m in depth for shafts, wells , cesspits , manholes , pier holes etc and getting out complete all as specified & directed.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3m in depth for foundation, etc or not exceeding 10 Sqm on plan for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete.
Removing excavated/demolished material to a distance exc. 1.5 Km but n.exc 5 Km and deposited where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed.
M & L for soil brought from outside of defence land as approved by GE and dumping in traverses of WSA , spreading , levelling , watering and well ramming complete all as specified and directed. (Note:- Extra quanity of soil will be obtained under respective item of removal of soil)
Spreading and levelling of earth in traverse etc and well ramming including watering complete all as specified & directed.
M&L for Brick work using sub class "B" bricks , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone agrregate) as in foundation, filling and mass concrete etc complete all as specified & directed.
Dismantling flor, hearth or wall tiling including cement mortar bedding (but not backing), removal serviceable tiles to store and rubbish of the premises complete all as specified & directed.
M&L for vitrified ceramic tiles 10 mm thick (Square/rectangular) double charged/dark shade , area of each tile not exc 0.36 Sqm, in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15 mm thick screed bed in CM(1:6) etc complete all as specified & directed.
M&L for non skid rectified edges (joint free) digitally designed coloured ceramic floor tiles not less than 7-8 mm thick (Square/rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm, in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over & including 15 mm thick screed bed in CM(1:6) etc complete all as specified & directed.
M&L for glazed ceramic coloured tiles thickness not less than 7 mm as in skirting / dado etc area exceeding 0.11 Sqm but not exceeding 0.18 Sqm and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick backing coat in CM (1:4) on fair faces of brick or concrete surface etc complete all as specified & directed.
M&L for 20 to 25 mm thick machine cut kota stone in slab flooring set & jointed in cement slurry and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing & polishing over & including 20 mm thick screed bed/ backing coat in CM (1:6) complete all as specifed & directed.
M&L for rendering 5 mm thick in CM (1:3) on concrete ceiling surface finished even and smooth using extra cement complete all as specified & directed.
M&L for P.C.C. 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping and benching complete all as specified & directed.
Demolition of plain cement concrete (unreinforced) of any mix / grade of ground floor and paving not exceeding 15cm thickness (below or above ground level) etc complete all as specified & directed .
Taking down chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frames) including builders hardware etc complete all as specified & directed.
Taking down chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) etc including builders hardware etc complete all as specified & directed .
S & F For Anodised aluminium frame for doors, windows, ventilators, with one or more rebates including joining cleat for fixing etc complete all as specified & directed .
S & F for 50 micron powder coated aluminium door shutters, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door , hinges anodised aluminium snap beading, screws, complete all as specified & directed .
S&F for mortice lock, vertical type 75 mm long, 4 lever of brass for aluminium door etc complete all as specified & directed.
S&F aluminium anodised extruded section barrel tower bolt 200 mm long complete all as specified & directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified & directed.
S&F Sheet glass 6.3 mm thick, ordinary quality and glazing with oil putty in squares exceeding 0.5 Sqm in each pane complete all as specified & directed.
S&F aluminium alco composite panel 5 mm thick of any color fixed to frame work or door etc complete all as specified & directed.
S&F aluminium powder coated sliding windows with shutter and frame made with aluminium section three track ( 50 % opening of each track will be provided with sliding shutter, one with stainless steel wire cloth and other two track consist of glass) and with aluminium grill . (i) Frame three track for top and side rails . (ii) Shutter 61.85 x 31.75 x 12 mm section No. 8687, 0.659 Kg /RM for bottom rail. (iii) Shutters 40x18x1.5 mm section No. 8820. (iv) Aluminium grill made out of aluminium section weighing not less than 1.50 kg/m. (v) Glass 4.8 mm thick tinted with rubber gasket and suitable clip (1.75 Sqm). (vi) Stainless Steel wire cloth.
Dismantling boarding, any description, fixed in any position with nails complete.
M&L for 10 mm thick gypsum ceiling to flat/curve surface to GI grid frame work 600mmX600mm size grid (suspended from roof by 2 mm dia GI wire @ 1 m c/c) reinforced with GI wire mesh complete all as specified and directed.
S&F Perforated particle board/tiles 12mm thick for insulation and accoustic purposes, 600mm x 600mm in size, fixed with nails to timber frame work or with staples on snap grip in ceiling complete all as specified and directed.
S&F 15 mm thick fine fissured board shapped mineral fibre accoustic false ceiling tiles/ gypsum board tiles with back duly sanded and finished with a coat of protective paint and front duly finished of ARMSTRONG false system of size 600x600 mm complete all as specified and directed.
Taking up or down steel tubing and connections 15 mm bore, including cleaning of serviceable tubing for reuse or remove all from site complete all as specifed & directed.
Taking up or down steel tubing and connections 20 mm bore, including cleaning of serviceable tubing for reuse or remove all from site complete all as specifed & directed.
S&F in repair Vitreous ware wash down water closet 580X440 mm ( Orissa pattern) white floor/wall hung type with PVC seat cover complete including connection to drain or out going pipe compelete all as specified and directed.
S&F in repair PVC valveless , syphonic action type , flushing cistern 10 litres capacity, white, with inlet, ball valve, float and handle and fixtures including brackets complete all as specified and directed.
S&F in repair Vitreous china full stall urinal ( back or corner wall type) including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; including providing & fixing automatic flushing cistern with brackets, flush pipe , grating and union for discharge pipe ( Exclusive of fixing supply pipe to flushing cistern , trap and waste pipe ) complete all as specified and directed. Make : Hindware and parryware.
S&F in repairs 15 mm Self closing Push taps /Stop cock for urinal,made of cast copper alloy, chromium palted ,screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs Vitreous Chinaware Wash hand basin , white , oval type , 550X400 mm size including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S&F in repair 15 mm bore chromium plated fancy type Bib taps , cast copper alloy with crutch , screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F 32 mm waste coupling CP for sinks/WHB etc with long screwed sanks and fly nuts flange with PVC waste pipe complete all as specified and directed.
S&F in repair 15mm bore Pillar taps CP fancy type screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair PVC connection 450 mm long with brass unions at both ends, suitable for 15 mm bore pipe complete all as specified and directed.
S&F in repair Soap dish , Chromium plated of approximate size as approved by Engg-in-Charge complete all as specified and directed.
S&F in repair CP Towel Ring 200 mm dia fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms) complete all as specified and directed.
S&F in repair Angle valve CP 15 mm dia , cast copper alloy, screwed down, high pressure, fancy type, chromium plated, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair 100 mm dia Cast iron floor trap with CP grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
Dismantling asbestos cement (Corrugated, semi corrugated etc ) sheets in roof covering complete all as specifed & directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick on an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specifed & directed
M&L for Providing and injecting chemical emulsion for Post Constructional Anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in apron complete all as specified and directed.
M&L for Anti-termite treatment of soil under existing floors using emulsion @ one litre per hole , 300 mm apart including drilling and plugging 12 mm dia holes and making good with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L for Anti-termite treatment of voids in masonry using chemical emulsion one litre per hole, at 300 mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed.
S&F Reinforced concrete pipes, class NP2, 200 mm bore, laid and jointed complete with collars including demolition of existing pipe complete all as specified and directed.
S&F Reinforced concrete pipes, class NP2, 150 mm bore, laid and jointed complete with collars including demolition of existing pipe complete all as specified and directed.
Supply and Laying 15 mm bore GI pipe medium grade with fittings laid in trenches, wall, floor etc complete all as specified and directed .
Supply and Laying 20 mm bore GI pipe medium grade with fittings laid in trenches , wall & floor etc complete all as specified and directed .
M&L for Concrete bed to drain pipes 200 mm bore including packing under and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate complete.
M&L for Concrete bed to drain pipes 150 mm bore including packing under and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate complete.
M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means complete all as specified and directed.
M&L for applying two coats of Exterior grade Acrylic emulsion paint (Apex) for base coat ( olive green) and two coats of different colour patches to make camouflage pattern over and including one coat of red oxide primer all upto 10 mtr height complete all as specified and directed.
M&L for complete removal of existing old paint , any number of coats , any width or grith of steel door /shutters and applying two coats of synthetic Enamel paint for base coat ( olive green) and two coats of different colour patches to make camouflage pattern over and including one coat of red oxide primer all upto 10 mtr height complete all as specified and directed.
Taking down cement plaster of brick or stone masonry, including raking out joints hacking for key & scrubbing down with water and removal of rubbish / mortar out off the premises / MD land etc complete all as specified & directed.
Removing old lime wash of unplastered surface ( if any) , including raking out joints of old brick work & scrubbing down with water to receive plaster complete all as specified & directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of old camauflage pattern painted wall/ceiling surface and applying one coats of Exterior emulsion paint (Apex) for base coat ( olive green) and two coats of different colour patches to match the existing camouflage pattern complete all as specified and directed.
M&L for preparation of old plastered or unplastered surface ( old decorated surface ) including cornices , pillars etc by brooming down & cleaning and applying one coat of white wash over ceiling complete all as specified and directed.
M&L for preparation of old plastered or unplastered surface and applying two coats of oil emulsion distemper , white or tinted on wall complete all as specified and directed.
M&L for preparation of old plastered surface or previously untreated surface and applying two coats of white wash on wall complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed
Taking down heavy iron door shutters area n. exc 10 sqm for addition , alteration and repair etc complete and refixing the same in the same opening including cutting of wicket gate having mortice lock welded in them opening outward and refixing of the same using angle and flat irons and all as required etc complete all as required and directed .( Angle and other section with gusset plates , MS sheets, rails ,rollars , wheels etc shall be measured and paid seperately in respective items).
S&F Framed work such as doors or gates (sliding type as directed by users) of angle or other section with gusset plate, MS sheet, rails, rollers, wheels etc confirming to Fe 250 quality A complete all as specified and directed.
M&L for Preparation of new steel & iron surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint over & including a coat of red oxide primer complete.
M&L for Preparation of new steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of red oxide primer complete.
M&L for Cutting holes in brick walls built in cement or cement lime mortar for inserting hold fasts, etc and making good dismantled portion in cement concrete 1:2:4 type B-1 and depth of embedded portion of holdfast or lugs measured from the face of the jamb into the wall exc one brick but not exc two brick complete all as specified & as directed.
M & L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregates) in footing for columns, foundation beams, plinth beam etc complete all as specified & directed. (Note: Reinforcement and Formwork shall be measured and paid separately under respective item of this Schedule)
M&L for Reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregates) in columns / pillars / post & struts etc complete all as specified and directed. (Note:- Reinforcement and formwork shall be measured and paid separately under respective item of this Schedule)
M&L for form work to sides of concrete foundations, footings, bases of columns, sides & soffits of plinth beams and similar work for rough finished flat surfaces of concrete etc complete all as specified and directed.
M&L for form work to sides of square or rectangular pillars, posts, struts, piers, column and stanchions by using steel plate / water proofing plywood for fair finished surfaces of concrete etc complete all as specifed & directed.
S&F TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, etc complete all as specified and directed.
All as per Srl item No. 78 but but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast articles complete all as specified & directed.
Demolition of plain cement concrete (unreinforced) of any description , mix / grade from ground floor and paving n exc 15 CM thickness including removal of debris exc 1.5 Km but n.exc. 5 Km complete all as specified and directed .
Demolition of plain cement concrete (unreinforced) of any description , mix / grade from ground floor and paving exc 15 CM thickness including removal of debris exc 1.5 Km but n.exc. 5 Km complete all as specified and directed .
Rolling of formation surfaces in cutting with power road rollers 8 to 12 tonne capacity including filling in hollows & depressions which occur during the process of rolling complete all as specified & directed.
Forming embankments including raising (or lowering) earth, spreading in layers not exc 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc not exc 1.5 m high from base complete. Note : Excavated earth shall be used for filling.
M&L for 150 mm thick compacted dry lean concrete (DLC) with 7 days compressive strength as 15 N/Sqmm with minimum cement (OPC) content 250 Kg / Cum of concrete including form work if required and rolling complete to achieve desired density and strength complete all as specified and directed. Note: In case of increase in cement content as per design mix formula, nothing extra shall be admissible and quoted rates are deemed to include for the same.
M&L for 150 mm thick (Compacted thickness) WBM laid in 2 layers of 75mm thick (compacted thickness ) each layer, spread, rolled and consolidated to required gradient and camber as required including necessary lateral support and form work, if required using crushed stone aggregate of grading 2 (63 to 40 mm size ) including filling of screening material type igneous rock such as granite/trap/basalt etc complete all as specified and directed.
M&L for 25 mm thick layer of sand including rolling over DLC complete all as specified and directed.
M&L for 400 micron polythene film sheet as per IS: 2508 over sand layer complete all as specified and directed. Note:-(i) Side lap of 150 mm and end lap of 300 mm shall be provided wherever required. The rate quoted shall be deemed included for the laps. (ii) Clear flat area after providing sheet shall be considered for payment purpose and nothing extra shall be allowed for laps.
M&L for finishing of concrete top surface by spike rolling to surface or making impressions of expanded metal , whilst the concrete is green without using extra cement complete all as specified & directed.
M&L for forming 12 mm thick expansion joint filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound grade A for 150 mm thick concrete slab complete all as specified & directed.
M&L for forming Contraction (Dummy) joints 30 mm deep x 10 mm wide , filled with sealing compound grade A for 150 mm thick concrete slab complete all as specified & directed.
M&L for forming Construction joints 30 mm deep x 10 mm wide , filled with sealing compound grade A for 150 mm thick concrete slab complete all as specified & directed.
M&L for 150 mm thick cement concrete work in pavement/hard-standing of flexural strength 40 Kg/per Sqcm in field using 400 kg of cement per cubic metre complete all as specified & directed.
M&L for Brick work using sub class "B" bricks ,old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed.
M&L Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete using extra cement , including forms, mould, mitred/stopped ends etc complete all as specified and directed.
M&L for P.C.C. 1:3:6 type C-2 using 40 mm graded stone aggregate as in Surface channels and drains complete all as specified & directed.
M&L for Boring of pilot bore having 150 mm internal dia of MS pipe in any kind of strata upto 85 mtr depth at three different locations with reverse rotary circulation method and getting out the strata incl electronic logging of the bore complete all as specified and directd.
S&F 150 mm bore PVC (SWR) pipes, threaded pipe, in any length with rubber ring joints, lowered in bore holes complete all as specified and directed.
S&F 150 mm bore PVC (SWR) pipes, threaded pipe, in any length with 1.58 mm slots including cager type wier wound galvanized screen complete all as specified and directed.
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick/concrete surfaces using WPC as per manufacturers instructions, finished even and smooth using extra cement complete all as specified and directed. (Note: WPC will be measured and paid separately under respective item)
Supply only polymer liquid water proofing compound of approved make all as specified & directed.
Dewatering of static water tank of different capacity at different locations all as specified & directed.
Digging out sludge etc from static water tanks at different locations and removing the same not exc 50 m distance all as specified & directed.
Supply only 4 mm dia GI wire mesh of size 125x125 mm and with 40mmX3mm size MS Flat Iron beading aroung all sides and fixed to weep holes in transverses by screwing complete all as specified and directed.
Material & labour for Chemical earthing complete with copper plate electrode 900mm x 600mm x5mm burried directly in ground vetically to a depth not less than 4.70 mtr below normal ground level (with top edge of earth plate not less than 3.60 mtrs below ground level ) connected to copper strip 32 mm x 6 mm as main earthing lead by means of brass brazing at all joints all as directed and connected to earth test point all as specified and testing on completion with and including necessary excavation and earth work in any type of soil ,GI pipe medium grade 50 mm bore for protection of copper strip from earth electrode to earth test point of galvanised Iron / steel , adequate quality of charcoal dust, common salt and magnesium sulphate in alternate layers of 100 mm thick x 6 layers all around the plate , and RCC (1:2:4 type B1 using 20 mm graded crushed stone aggregate ) cover of size 54x54x50 mm reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel flushed type handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in drawing. Note a). Cost of copper strip and GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items. b) On testing,after completion of job ,if desired earth resistence (less than 1 Ohm ) is not found ,the earthing shall be redone at no extra cost to govt.
S & F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.
S & F Copper strip 25 x 3.15mm duly fixed on the wall by saddles, clamps, fixing screws etc. and necessary drilling for tapping off branch connections complete all as specified and as directed.
Horizontal boring under Road, pavement, hardstanding complete for inserting HDPE pipe of size 50 to 80mm dia all as specified and directed. Note :- HDPE pipe shall be measured and paid seperately
M & L for 80 mm dia HDPE Pipe having pressure rating 6 Kgf/Sqcm with necessary jointing , if required, laid in trenches or inserting in horizontal boring complete all as specified and directed.
M & L for 50 mm dia HDPE Pipe having pressure rating 6 Kgf/Sqcm with necessary jointing , if required, laid in trenches or inserting in horizontal boring complete all as specified and directed.
Supply and laying dry coarse sand, as in cushioning for under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness complete all as specified and directed. (Note:- Punned thickness shall be measured)
Supply and laying LT UG Cable, 50 Sqmm 3.5 core, 1100 Volts grade, heavy duty, with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape, armored with galvanized steel wire or tape and over all PVC sheathed nominal cross section stranded conductor including taking down of existing cable complete all as specified and directed.
Supply and laying LT UG Cable, 70 Sqmm 3.5 core, 1100 Volts grade, heavy duty, with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape, armored with galvanized steel wire or tape and over all PVC sheathed nominal cross section stranded conductor including taking down of existing cable complete all as specified and directed
Supply and laying LT UG Cable, 16 Sqmm 4 core, 1100 Volts grade, heavy duty, with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape, armored with galvanized steel wire or tape and over all PVC sheathed nominal cross section stranded conductor including taking down of existing cable complete all as specified and directed.
Supply and laying LT UG Cable, 10 Sqmm 4 core, 1100 Volts grade, heavy duty, with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape, armored with galvanized steel wire or tape and over all PVC sheathed nominal cross section stranded conductor including taking down of existing cable complete all as specified and directed
Laying only serviceable bricks , in cable trench, as obtained during taking up of old cables from the existing cable trench .complete all as specified & directed.
Supply and laying of well burnt sub class ‘B’ bricks (using old size brick) laid in trenches above sand cushioning for cable protection complete all as specified & directed.
Supply and fixing Cast Iron specials such as bends (any type, radius and angle ) tapers any type (straight, bend,increasing,decreasing or double socket etc.)Tee piecessingle branch, Y junction,double branc, cross (all sockets or socket and spigot)collars, caps and plugs etc. all as specified and as directed.
Material and labour for Cutting existing CI pipe of size 100 mm bore in position for insertion of new CI specials with all connected acessories including lead joints complete for taking a branch connection of 50mm all as specified and directed. Note : Excavation and earth work shall be measured and paid separately under respective items mentioned here-in- before.
Supply and Laying 50 mm bore GI pipe medium grade with fittings laid in trenches, wall, floor etc complete all as specified and directed .
Supply and Laying 40 mm bore GI pipe medium grade with fittings laid in trenches , wall & floor etc complete all as specified and directed .
Supply and Laying 25 mm bore GI pipe light grade with fittings laid in trenches , wall & floor etc complete all as specified and directed .
Supply & fixing of 50 mm dia Gun metal glove or gate valve ISI mark (heavy duty) with iron wheel,hand screwed both end for iron pipe complete all as specified and directed.
Supply & fixing of 40 mm dia Gun metal glove or gate valve ISI mark (heavy duty) with iron wheel,hand screwed both end for iron pipe complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded aggregate for coping of pipes to make stand posts , drain & benching etc. complete all as specified and as directed.
Supply and fix 15 mm bore bib tap plug type ,Cast Iron,screwed for iron pipe of and fixed with 25mm bore GI Pipes stand post by providing a reducer socket / Reducer elbow all as specified and as directed.
M&L for brick masonary valve pit of size 900mm x 900 mm x 900 mm with necessary excavation and earth work, PCC 1:3:6 in foundation brick work in Cm 1:6 plastering 15 mm thick rendering in CM 1:4 internally, 5 mm thick MS plate cover incl MS angle iron frame including preparation of new steel & iron surface & applying two coat of synthetic enamel paint over a coat of red oxide primer and including locking arrangement by lock & key complete all as specified and as directed
M&L for brick masonary valve pit of size 600mm x 600 mm x 600 mm with necessary excavation and earth work, PCC 1:3:6 in fondation brick work in Cm 1:6 plastering 15 mm thick rendering in CM 1:4 internally, 5 mm thick MS plate cover incl MS angle iron frame including preparation of new steel & iron surface & applying two coat of synthetic enamel paint over a coat of red oxide primer and including locking arrangement by lock & key complete all as specified and as directed
Dismantling and taking down of existing Steel Tubular swaged pole from its existing position including breaking of P.C.C. foundation concrete by necessary tools and plant and removing from the site complete including making good to disturbed surface and Supply and erection of new steel tubular pole swaged type 410-SP- 31 (LT 09.00 mtr long pole) conforming to IS: 2713 factory pre red oxide primered with 6mm thick MS welded base plate, pole cap all as specified in & including following :- (a) Excavation for pole foundation & getting out in soft/loose soil , RFR and disposal of surplus soil to a distance not exceeding 50 mtrs. (b) M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) in foundation 900mmx600mm cross section and planting depth 1.5 mtr for concrete encasing the pole upto GL complete all as specified and directed. (c) M&L for providing PCC 1:2:4, type C-1 (using 20mm graded crushed stone aggregate) for plinth block/collar above GL 500mm high and 450mm dia complete all as specified and directed. (d) M&L for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminum paint (over a factory coat of red oxide primer) including preparation of surface and painting 30 cm wide bands with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5mm above plinth block. (e) M&L for writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of approved shade not exceeding 5 cm height including numbering of pole complete all as specified and directed. (f) Painting of coping with cement based paint all as directed. (NOTE : Manufacture's test certificate shall be produced before pole execution work.)
Dismantling and taking down Aluminium strips of any size,for down conductor, from the steel tubular pole including insulators, clamps etc.complete all as specified and as directed.
M & L for Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron strip 25x 4mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 40mm bore medium grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC M-25 cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-1 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre shall be deemed to be inclusive in the quoted rate. 2. Earth filling shall be done by vegitable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
M&L for purpose made M.S. Clamps, supports, bolts, nuts, washers etc. for fixing of shackle insulators on the pole, spacers / separators for down conductors, fixing of Air Termination Rods etc. complete including painting with two coats of Aluminium paints over a coat of red oxide metal primar all as specified and as directed.
Supplying and fixing Shackle type, Porcelain, Vitreous, white,brown or green insulator including galvanized Mild Steel straps, washers,insulator bolts, washers and nuts suitable for 550 volts (for hanging of arial conductors) and overall dimension 50mm height &65 mm dia all as specified and as directed.
Supply and Fix of ACSR conductor, of required size as the requirement at site, for Aerial conductors, with connected works and welding all as specified and directed.
Supply and Fixing suitable size 'F' class bridge insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material suitable for separator / spacer of aluminium strip from the steel pole. Note : Fixing accessories such as clamps,nuts, bolts, washers etc. shall be measured and paid separately under respective items mentioned here-in-above.
M & L of Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground.
M & L of Air termination, single pointed aluminium rod 12mm dia and 300mm long with all connected accessories and fixed on PCC Block of size 300mm x 300mm x 300mm complete all as specified and directed. Note : P.C.C. block shall be measured and paid separately under respective item mentioned here-in- above.
Supply and fix test point termnal block made of gun metal or phosphorus bronze size 75 X 75 X 25 mm drilled and screwed including three Nos 8 mm dia 25 mm long hexagonal head screw all as specified.
Supply installation, testing and commissioning of Duct based automatic fire damper complete with smoke detector/thermister and motorized actuator as required for operation,including necessary control wiring complete for Danger Building No 01 Note : The Fire damper should work till 120 Minuts in case of fire.
Supply installation, testing and commissioning of Duct based automatic fire damper complete with smoke detector/thermister and motorized actuator as required for operation,including necessary control wiring complete for Danger Building No 06 Note : The Fire damper should work till 120 Minuts in case of fire.
Supply installation, testing and commissioning of Duct based automatic fire damper complete with smoke detector/thermister and motorized actuator as required for operation,including necessary control wiring complete for Danger Building No 07 Note : The Fire damper should work till 120 Minuts in case of fire.
Supply installation, testing and commissioning of Duct based automatic fire damper complete with smoke detector/thermister and motorized actuator as required for operation,including necessary control wiring complete for Danger Building No 08 Note : The Fire damper should work till 120 Minuts in case of fire.
Supply installation, testing and commissioning of Duct based automatic fire damper complete with smoke detector/thermister and motorized actuator as required for operation,including necessary control wiring complete for Danger Building No 18 Note : The Fire damper should work till 120 Minuts in case of fire.
Supply installation, testing and commissioning of Duct based automatic fire damper complete with smoke detector/thermister and motorized actuator as required for operation,including necessary control wiring complete for Danger Building No 27 Note : The Fire damper should work till 120 Minuts in case of fire.
Supply installation, testing and commissioning of Duct based automatic fire damper complete with smoke detector/thermister and motorized actuator as required for operation,including necessary control wiring complete for Danger Building No FSA (BP-23). Note : The Fire damper should work till 120 Minuts in case of fire.
Supply and Fix Installation of 16 mtr High Mast shaft in two sections suitable to withstand 50m/sec wind speed, with raising lowering system comprising head frame, luminaries carriage suitable to install 12 nos luminaries in symmetrical arrangement,double drum winch,6mm diameter Stainless Steel wire rope, trailing cable connector, integral power tool motor,manual handle,junction box,lightning finial,(Wiring material from JB to individual luminaire & MCB in base compartment are included and are a part of installation) with foundation bolts manufactured from special steel along with nuts, washers,anchor plate and common template, with outdoor type stand mounted feeder pillar with 63 A TPN MCB incomer,single dial time switch, 45 A TP contactor for the automatic switching of luminaries,power tool control with 2 nos 9A contactors and raise / lower push button, incoming 10 sqmm and out going 10 & 2.5 sqmm terminals including construction of shallow foundation with M-20 grade concrete for the high mast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour including erection of the high mast with the help of suitable tools and plants,wiring of luminaires with all wiring materials like PVC insulated PVC sheathed suitable core flexible cable of copper conductor of suitable size, lugs, MCB and all labour.including provision of 4 Nos GI Pipe earthing (02 Nos for mast and 02 Nos for electrical panel) as per electrcal plate No. 3 of SSR Part-I with 2.5 M long 40mm dia perforated GI pipe including connection to high Mast earth terminal with 25x3mm GI flats with all materials and labour including installation of the electrical feeder piller by grouting the stand in concrete pedestal complete all as specified and as directed. Note : (i) Rate quoted shall deemed to be included of excavation of earth and RCC foundation as per OEM's design & drawing.complete. (ii) Luminares will be measured and paid under respective items as mentioned here-in-under.
Supply and Fixing LED Flood light of capacity 150 to160 Watts and having lumen efficacy not less than 100 lumens / watt and capacity of in-built surge protector not less than 10 KV and with Ingress protection level IP-66 Complete including fixing on 16.0 Mtr High Mast all as specified and directed. Make : HAVELLS (Cat No : JETAPROPLUSSFL150WLED757LTG) or Equivallent model in PHILIPS / CROMPTON / BAJAJ
Supply and Fix Integralf LED aviation obstruction light luminaires of capacity 10 watts comprising of aluminum housing with polycarbonate enclosure having 302 Nos. LED and accessories suitable for fixing at directed location. Make ; Bajaj (Cat No. BGAV 302 LED) or equivallent model in Havells / Philips / CROMPTON.
Dismantling of ACSR or AAC conductors from existing O/H line complete all as specified and directed.
Dismantling earth wire from existing O/H line complete all as specified and directed.
Dismantling and taking down M.S. cross-arms, bolts,nuts, washers and clamps etc. from electrical poles complete all as specified and directed.
Disconnection, dismantling and taking down old dillapidated Bus Bar Chamber of any size and description from site and Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 750mm width x 750mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars (current carrying capacity 100 amps) for cable termination, The bus bar chamber shall be compartmentalized type suitable for separate chambers for Bus Bars, Cable Alley & switchgears duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of enclosure and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The bus bar chamber shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the brick pedestal through grouting bolt, The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. Thefollowing components shall have to be fixed inside the bus bar chamber :- a) MCB TPN 63 Amps (10 KA) - 01 No for incomer b) MCB TPN 40 Amps (10 KA) - 02 Nos.for outgoings (1 No for next bus bar chamber & 1 No for branch connections) c) LED Phase indicator lamp suitable for 230 volts - 03 Nos (Red-Yellow- Blue) d) Control fuse 3 amps for the LED lamps.- 03 Nos.
Supply and Fixing LED Street light of capacity 70 to 75 Watts and having lumen efficacy not less than 100 lumens / watt and capacity of in-built surge protector not less than 10 KV and with Ingress protection level IP-66 Complete with dismantling and taking down old unserviceable security light fittings from existing poles all as specified and directed. Make : HAVELLS (Cat No :ENDURAPEARLSL70WLED757PASYTOPCPLUS) or Equivallent model in PHILIPS / CROMPTON
Supply and Fixing street light Bracket made out of 40 mm dia light grade GI pipe 1.2m length duly cold bent to shape for fixing on pole and suitable for street light fitting with 02 pairs of clamps made of M.S. flat of size 40x4 mm including M.S. nuts,bolts and washers including painting of clamps with two coat of aluminium paint over a coat of red oxide metal primer complete including dismantling and taking down old unserviceable street light brackets from poles all as specified and directed.
S&F Weather Proof thermo plastic (Polysterene) Cable Junction box , having protection class IP-66 and of overall size 205mm x 255mm x 112mm having metric knockouts on the wall, duly fixed with the pole with aluminium strip (25x3mm) clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands of cable sealing range 17mm to 25mm (Complete with check nut) and including 1 No 30 Amps 5 Way cable connector (HENSEL Make) and 1 No. 6 Amps SP MCB. Make of Box : HENSEL (Cat No.- DK 1616 G) or Equivallent model in SPELSBERG / RITTAL / GEWIS Make of Cable gland : HENSEL (Cat No. - 1555.32.25) or Equivallent in SPELSBERG / RITTAL / GEWIS
S&F three core PVC insulated flexible round cord 1.5 sqmm multi stranded copper conductor flexible cables 1100 Volt grade complete and making connection from pole box to Flood light all as specified and directed. Make: Finolex / Polycab / Havells / Plaza
Shifting of Flame proof electrical control box including connected accessories and wirings and steel conduits from insidewall of storage accomodation to outside wall of the building complete all as specified and directed
(xi) Electronic timer type ET, suitable for 24 volts, DC supply as per recommendation of DG manufacturer - DC supply for 0 - 30 second. -01 No. (xii) Engine starting relay with sequence timer & master timer suitable for 24 volts DC supply as per recommendation of DG manufacturer.-01 No. (xiii) Battery charging unit 24 volts DC as per recommendation of DG manufacturer-01 No.. (xiv) By pass arrangment with rotary type by pass Change over switch AC on load to isolate the AMF panel.-01 No. (xv) Three pole power contactor with standard coil voltage of 415 volts 50 Hz and auxiliary contact of 02 Nos having AC three phase rating of 250 Amps MNX series MNX225 type of size FR-05 of L&T cat part No. CS94141 or eqvt of Siemens/Schinder/Legrand/BCH- 02 Nos(xvi) Booster relay of 24 volts capacity.-01 No. Note : If any other connected item(s) is missedout in the above description, it should be provided without any extra cost to the department. The quoted rate shall deemed to be inclusive of all necessary items.
(x) Underer / over voltage relay, suitable for 3 phase 415 volt AC -3 supply.-02 Nos (xi) Electronic timer type ET, suitable for 24 volts, DC supply as per recommendation of DG manufacturer - DC supply for 0 - 30 second. -01 Nos. (xii) Engine starting relay with sequence timer & master timer suitable for 24 volts DC supply as per recommendation of DG manufacturer.-01 Nos. (xvi) Battery charging unit 24 volts DC as per recommendation of DG manufacturer-01 No.. (xiv) By pass arrangment with rotary type by pass Change over switch AC on load to isolate the AMF panel.-01 Nos (xv) Three pole power contactor with standard coil voltage of 415 volts 50 Hz and auxiliary contact of 02 Nos having AC three phase rating of 650 Amps MNX series type of size FR-06 of L&T cat part No. CS96327 or eqvt of Siemens/Schinder/Legrand/BCH -02 Nos (xvi) Booster relay of 24 volts capacity.-01 Nos Note : If any other connected item(s) is missedout in the above description, it should be provided without any extra cost to the department. The quoted rate shall deemed to be inclusive of all necessary items.
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 2100mm width x 1000mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 400 amps, Provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables and 4 way ebonite cable connector (rating 32 amps) for termination of outgoing cablesfor MCBs.TheFeeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 400 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size FRLS grade PVC insulated multiflexible type copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.
INCOMING :- 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA Fixed magnetic and Fixed thermal setting (100% - 80%) of rating 250Amps. Make : LEGRAND /SCHNEIDER / ABB OUTGOING :- a) MCCB 63 Amps (16 KA) 4 Pole Adjustable thermal(100% - 80% and fixed magnetic setting - 06 Nos SECURITY LIGHT CONTROLLER This should be made of the following articles complete with all wiring harness as required :- (ii) TPN MCB 16 Amps having breaking capacity 10 KA - 03 Nos Make : LEGRAND /SCHNEIDER / ABB (ii) 3 Pole power contactor, suitable for 415 volts AC 50 Hz supply and current carrying capacity 32 Amps. - 01 No. Make : L&T (ML-2) / BCH / TC
CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.Note : 1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. 2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. 3) All the inner / outer doors should have locking facility through castle locks 4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. 5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. 6)The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm 7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. 8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process. Note : 1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. 2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. 3) All the inner / outer doors should have locking facility through castle locks 4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. Note:- 1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. 2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. 3) All the inner / outer doors should have locking facility through castle locks 4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. 5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. 6)The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm 7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. 8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
6)The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm 7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. 8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 2100mm width x 1000mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 600 amps, Provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables and 4 way ebonite cable connector (rating 32 amps) for termination of outgoing cablesfor MCBs.TheFeeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :- PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables.
BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 600 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size FRLS grade PVC insulated multiflexible type copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA Fixed magnetic and Fixed thermal setting (100% - 80%) of rating 400Amps. Make : LEGRAND /SCHNEIDER / ABB
OUTGOING :- a) MCCB 250 Amps (16 KA) 4 Pole Adjustable thermal(100% - 80% and fixed magnetic setting - 01 No b) MCCB 63 Amps (16 KA) 4 Pole Adjustable thermal(100% - 80% and fixed magnetic setting - 03 Ns Note : 1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. 2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. 3) All the inner / outer doors should have locking facility through castle locks 4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. 5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department.
6)The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm 7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. 8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
Taking Down Old U/S flame proof light fitting from its existing position and S&F of CMRI Certified LED Flameproof 1x16/20W LED Tube Light Fixture with Recommended for Gas/Vapor Group of IIA & II B and Zone 1& IP 65 Protection.etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specidfied & directed. Make Crompton Cat part No EXTN2LT8-16/20, Bajaj / SUDHIR / BALIGA or equivalent make/model as approved by GE.
S & F of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V including taking down of existing complete all as specified & directed. Make;- SUDHIR/BALIGA/PHILIPS
Material and Labour for point wiring complete with 1100 Volt grade FRLS PVC insulated unsheathed cable, multi-stranded copper conductor of size 1.5 sqmm conforming IS 694 & colour code in conduit system of wiring, drawn in and including medium grade stove enamelled Steel conduit not less than 20 mm dia concealed, including cutting chases and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size of not less than 1.2 mm thick factory made and factory painted with top cover 3mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including FRLS single core solid conductor copper 1.5 sqmm size solid PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit including taking down old U/S point wiring complete all as specified and directed
Material and Labour for sub main wiring complete with 2 x 6 Sqmm single core multi stranded copper conductor 1100 volt grade PVC FRLS) insulated unsheathed cable drawn in and including medium grade stove enamelled Steel conduit ISI Marked not less than 25 mm dia concealed, on surface,including single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable 4.0sqmm size as earth wire drawn in same conduit complete including making good distributed surface of wall,including taking down old U/S sub-main wiring complete all as specified and directed .
Material and Labour for sub main wiring complete with 2 x 4 sqmm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable drawn in and including Perimiter ISI Marked not less than 25 mm dia PVC conceale including making good distrubed surface, of wall, including single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable 4.0 sqmm size as earth wire drawn in same conduit complete including making good distrubed surface of wall including taking down old U/S sub-main wiring complete all as specified and directed .
S & F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth complete all as specified & directed. Make;- SUDHIR/BALIGA/PHILIPS
Material and Labour for point wiring complete with multi-stranded copper conductor 2.5 sqmm size PVC insulated unsheathed cable 1100 Volt grade, conforming IS 694 & colour code in conduit system of wiring, drawn in including medium grade in stove enamelled Steel conduit not less than 20 mm dia concealed, including cutting chases and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size of not less than 1.6 mm thick factory made and factory painted with top cover 3mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core solid conductor copper 2.5 sqmm size solid PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit including taking down old U/S point wiring complete all as specified and directed.
Suuply and fix CMRI Certified LED Flame Proof Bulkhead/ Wellglass Luminaire recommended for Gas/Vapor Group of IIA & IIB and Zone 1&2 Die cast Aluminum housing with heat resistant toughened glass.IP65 Protection add suffix HB to the Cat. complete incuding taking down old U/S light fitting complete all as specified and directed Make : Crompton , Sudhir or equivalent make as approved by GE.
Supply and Fix Flame Proof Control Panel Box size 500mm x 185mm Inner depth 150mm main Incomer 63 AMP Double Pole MCB-1 Nos Out going 16 Amp DP MCB-06 Nos with Switch Socket Combine 16 AMP 230 Volt 3 PIN-2 Nos complete including taking down old U/S control box all as specified and directed. Make;- SUDHIR/BALIGA/PHILIPS
Taking down old U/S Distribution board of any description including MCBs / Isolators etc.and Supply and Fix flush mounting factory made SPN DB's Double door , protection level IP-43 Protection ,IK-09 with metal door ,with neutral bar ,Earth bar and cables ties for cable management fully insulated bus bar 8 way complete all as specified and directed.
Supply and fix MCB single pole and neutral, 240 volts, 32 to 40 amps breaking capacity 10KA, ‘C’ Series. etc , complete all as specified and directed.
Supply and fix MCB single pole 240 volts, 6 to 32 amps, 50HZ, 10 KA. , ‘C’ series all as specified and directed.
Taking down old u/s electric siren and Supply and Fix electric siren single phase 220/250 Volt 6000 RPM 50 Hz AC of Horizontal double Mounting siren 3.25 KM radius 1/2 HP DS-325 with all connected accessories including fixing at site with and connected accessories complete all as specified and directed Make : SIYARAM ELECTRICALS/ KHERAJ mAKE OF dol STARTER : L&T/ SIEMENS/ TELEMECHANIC/BCH
S&F two core PVC insulated Hevy Duty Armoured cable 1.5 sqmm Solid copper conductor cables 1100 Volt grade complete and making connection from MCP to Siren /Repeater Panel all as specified and directed. Make: Finolex, Polycab, Havells, Plaza & Grandlay.
Supply and fix addressable type Manual call point break glass type compatible with main fire alarm control board microprocessor based as per IS-2189 and including chain hammer facility and blinking facility complete all as specified and directed. Make: Agni, safeway, Suraksha, Ravel, Apolo
Builders Harpal
yash enterprises
Sudhir Sharma Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .