Loading…
Loading…
Tender ID
Tender Value
₹30 L
EMD Value
₹40,000
Closing Date
16 Feb 2026, 6:00 pmClosed
Executive Engineer, RANDER DIVISION
Work of ARC for Erection &Maintenance of HT/LT Line and TC work and other maintenance work O/H & UGXLPE Cable & Laying of underground cable network with terminations inthe area of DGVCL under all schemefor Rander T-1, T-2 , Adajan , Pal ,Palanpore , Ramnagar Sub division under Rander Division and if required work to be carried out at other subdivision under Rander Division.
272155
DGVCLSDPLN/0005/02/2026 Approved Date: 02-02-2026
Open
Electrical - All
Works
Surat
3 documents required · 3 mandatory
₹1,180
SURAT
₹40,000
2 Feb 2026
2 Feb 2026
2 Feb 2026
16 Feb 2026
2 Feb 2026
Name of Work : Work of ARC for Erection & Maintenance of HT/LT Line and TC work and other maintenance work
O/H & UG XLPE Cable & Laying & Commissioning of UG Cable with as per REC Norms for Rander T-1,Rander T-
2,Pal,Adajan,Ramnagar, Palanpore Sub division under Rander Division under All scheme and if required work to be
carried out in Other Sub Division under Rander Division.
Part- A- HT,LT& TC WORK & O/H UG XLPE Cable
CAPITAL WORK LABOUR RATES FOR FY 2024-25 (WITHOUT GST)
Item Code Item Unit FY 2024-25
HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING OF
CROSS ARMS, CLAMPS ANTI-CLIMBING DEVICES, DANGER
BOARD, INSULATORS ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS AND NUMBERING COMPLETE WITH
COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF PSC POLES OF 8 *200 KG INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING
OFCROSS ARMS, TOP FITTING CLAMPS ANTI-CLIMBING
DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
ERECTION OF STEEL POLES OF 9 TO 11 METERS INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING
OFCROSS ARMS, TOP FITTING CLAMPS ANTI-CLIMBING
DEVICES, DANGER BOARD, INSULATORS ETC. COMPLETE AND
PAINTING OF STEEL POLE, FABRICATED MATERIALS USED ON
THE POLEAND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SET AND EARTHING.
ERECTION OF STEEL POLE OF 13 METERS FOR RAILWAY
CROSSING ON BG/MG/NG LINE FOR 0.400/11/22KV OVERHEAD
LINES I.E INCLUDING EXCAVATION OF PIT & REFILLING OF
EARTH, FIXING CROSS ARMS, TOP FITTING CLAMPS,ANTI-
4 9926000004 CLIMBING DEVICES DANGER BOARD, INSULATORS ETC. No.
COMPLETE AND PAINTING OF STEEL POLES, FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING WITH
COSTOF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS
KG PSC POLES INCLUDING EXCAVATION OF PITS & REFILLING
OF EARTHING, FIXING OF CHANNELS, SUPPORTING
ANGLES,CLAMPS, ANTI-CLIMBING DEVICES DANGER
5 9926000005 BOARDS,INSULATORS ETC.COMPLETE AND PAINTING OF No.
FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE OF 9 TO
METERS.STEEL POLE INCLUDING EXCAVATION OF PITS &
REFILLING OFEARTH, FIXING OF CHANNELS, SUPPORTING
ANGLES, CLAMPS,ANTI-CLIMBING DEVICES DANGER BOARDS,
6 9926000006 INSULATORS ETC.COMPLETE & PAINTING OF No.
POLES,FABRICATED MATERIALSUSED ON THE POLES AND
NUMBERING WITH COST OF PAINTSAS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF
AB SWITCH, HG FUSES OF 8 MTRS 200 KG PSC POLES
INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH,FIXING OF CHANNELS SUPPORTING ANGLES, CLAMPS,
ANTI-CLIMBING DEVICES, DANGER BOARDS,
INSULATORS,DOFUSES ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COSTOF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDINGOF ERECTION OF GUY SET
AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF
AB SWITCH,HG FUSES, 9 TO 11 METERS STEEL POLES
INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH,
FIXING OFCHANNEL, SUPPORTING ANGLES, CLAMPS, ANTI-
8 9926000008 CLIMBING DEVICES , DANGER BOARDS, INSULATORS, ETC. No.
COMPLETE AND PAINTING OF POLES FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING
OFAB SWITCH, HG FUSES, TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX. OF 8 METER,200KG PSC
POLE METERS POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS
FROMSTORES TO SITE, FIXING OF CHANNELS, SUPPORTING
ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING
DEVICES DANGER BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS
USEDON THE POLES AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF
AB SWITCH,HG FUSES TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX 9 TO 11 METERS STEEL
POLES INCLUDING EXCAVATION OF PITS & REFILLING OF
EARTH CARTING OF TRANSFORMERS FROM STORE TO SITE,
FIXINGOF CHANNELS SUPPORTING ANGLES, BRACING, CROSS
ARMS,CLAMPS, ANTICLIMBING DEVICES, DANGER
BOARDS,CONDUCTOR AND CABLE WIRING ETC. COMPLETE
AND PAINTING OF POLES FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTIONS OF GUY SETS
ERECTION OF GUY SET INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTH AS PER STANDARD SPECIFICATION
11 9926000011 WITH STAY CLAMPS, STAY WIRE, ANCHOR ROD, TURN No.
BUCKLE, EYEBOLT, GUY INSULATOR, CEMENT CONCRETE
BLOCK ETC. BUT EXCLUDING CONCRETING.
CONCRETING OF POLES, GUYS, ETC. INCLUDING COST OF
CEMENT SAND METAL (1:2:4) AND WATER ETC. AS PER
STANDARD SPECIFICATION.(cement Should be 53 grade) used for
ERECTION OF COIL TYPE EARTHING INCLUDING COST OF
13 9926000013 COAL,SALT ETC. BUT WITHOUT COST OF GI WIRE AS PER No.
STANDARD SPECIFICATION(20kg solt+20kg coal)
ERECTION OF GI PIPE/CI PLATE TYPE EARTHING
INCLUDINGCOST OF COAL SALT ETC. BUT WITHOUT COST OF
PIPE/GIPLATE GI WIRE AS PER STANDARD
SPECIFICATION.(20kg solt+20kg coal)
ERECTION OF STREET LIGHT FIXTURE COMPLETE WITH
CLAMPS, BRASS NIPPLE, BRASS HOLDER TECK WOOD
BUSH,REFLECTORS FUSE, WIRING ETC. AS PER STANDARD
SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
STRINGING OF(30mm2)ACSR/34MM@,55MM2 AAA CONDUCTOR
for ALL TYPE OF CONDUCTOR (EXCEPT DOG CONDUCTOR)
FOR 11/22KV & LT LINES INCLUDING FIXING OF INSULATORS,
BINDING JUMPERING ETC.
STRINGING OF GI WIRE 8 SWG INCLUDING BINDING
PROVIDING SINGLE PHASE SERVICE CONNECTION WITH PVC
2.5/4MM2 TWIN CORE CABLE FROM TERMINAL POLE TO
18 9926000018 METERING POINT INCLUDING FIXING OF METER WITH METER No.
EARTHING COMPLETE WORK AS PER STANDARD
SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE SERVICE CONNECTION
WITH PVC 4MM2/10MM2 FOUR CORE CABLE FROM TERMINAL
19 9926000019 POLE TO METERING POINT INCLUDING FIXING OF METER WITH No.
METER EARTHING COMPLETE WORK AS PER STANDARD
SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD ROCK
AREA FOR ERECTION OF POLE/ GUY ETC. AS PER STANDARD
SPECIFICATION OVER & ABOVE NORMAL COST COVERED
AGAINST EXCAVATION OF PIT UNDER NORMAL SOIL FOR
ERECTION OF POLE,GUY, DOUBLE POLE STRUCTURE
EARTHING WITH THE APPROVAL OF SUPDT.ENGINEER.
21 9926000021 PROVIDING GUARDING TO HT LINE ON ROAD/ RAIL CROSSING. MTR
22 9926000022 PROVIDING GUARDING OF LT LINES ON ROAD/RAIL CROSSING. MTR
23 9926000023 LT LINE TAPPING- SINGLE PHASE No.
24 9926000024 LT LINE TAPPING- THREE PHASE No.
Stringing/LAYING OF OVER HEAD LT CABLE FOR ROAD
25 9926000025 CROSSING,HT LINE CROSSING AND TELEPHONE LINE No.
CROSSING ETC.(PER SPAN)
ERECTION OF SINGLE POLE STRUCTURES WITH , HG
FUSES,TRANSFORMERS, LIGHTENING ARRESTOR,
DISTRIBUTION BOX. ON 8 METERS 200 KGAND PSC POLE
INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH,
CARTING OF TRANSFORMERS FROM STORES TO SITE, FIXING
OF CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS
ARMS CLAMPS, ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED ON THE POLE
AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OFGUY SETS AND
ERECTION OF SINGLE POLE STRUCTURES WITH MOUNTING
OFAB SWITCH , HG FUSES,TRANSFORMERS,
LIGHTENINGARRESTOR, DISTRIBUTION BOX. ON 9 to
METERS RSJ POLE INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS FROM
STORES TO SITE, FIXING OF CHANNELS, SUPPORTING
ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING
DEVICES DANGER BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS
USED ON THE POLE AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND EARTHING.
ERECTION OF PSC POLES OF 10 *270 KG INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING OF
CROSS ARMS, TOP FITTING CLAMPS ANTI-CLIMBING DEVICES,
28 9926000028 INSULATORS ETC. COMPLETE AND PAINTING OF FABRICATED No.
MATERIALS USED ON THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 10 METERS
KG PSC POLES INCLUDING EXCAVATION OF PITS & REFILLING
OF EARTHING, FIXING OF CHANNELS, SUPPORTING
ANGLES,CLAMPS, ANTI-CLIMBING DEVICES DANGER
29 9926000029 BOARDS,INSULATORS ETC.COMPLETE AND PAINTING OF No.
FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
EARTHING.(WITHOUT AB SWITCH)
STRINGING OF 100MM2 ACSR/100MM2 AAAC CONDUCTOR FOR ONE
30 9926000030 11/22KV & LT LINES INCLUDING FIXING OFINSULATORS, COND
BINDING JUMPERING ETC. PER KM
STRINGING OF DOG CONDUCTOR FOR 11/22KV & HT LINES
INCLUDING FIXING OF INSULATORS, BINDING JUMPERING ETC.
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING
OF AB SWITCH, HG FUSES, TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX. OF 10 METERS 270 KGAND
PSC POLES INCLUDING EXCAVATION OF PITS AND REFILLING
OF EARTH, CARTING OF TRANSFORMERS FROMSTORES TO
SITE, FIXING OF CHANNELS, SUPPORTING ANGLES,BRACINGS
CROSS ARMS CLAMPS, ANTI-CLIMBING DEVICES,DANGER
BOARDS, CONDUCTOR AND CABLE WIRING ETC.COMPLETE
AND PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SETS AND EARTHING.
DISMENTALLING OF 8 MTR PSC POLE WITH CREDITING OF
33 9926000033 FABRICATION AT STORE & STACKING OF POLE SAFELY ON No.
ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE WITH CREDITING OF
34 9926000034 FABRICATION AT STORE & STACKING OF POLE SAFELY ON No.
ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC
POLE) (WITH TRANSFORMER) WITH CREDITING OF
35 9926000035 FABRICATION & TRANSFORMER AT STORE & STACKING OF No.
POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC
POLE) (WITHOUT TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE & STACKING OF POLE SAFELY ON
ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, LT
SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE
AND TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH
CABLE BY INSULATED PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ
MM INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS
38 9926000038 ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF KM
MESSENGER WIRE AND TO PROVIDE SERVICE CONNECTION
ON AERIAL BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED BY ENGINEER IN
STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM,
BINDING TO PIN INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED & DIRECTED BY
ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM,
BINDING TO PIN INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED AND DIRECTED BY
ENGINEER IN CHARGE
STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, LT
SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE
AND TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH
CABLE BY INSULATED PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
DISMENTALING OF RSJ (9/11 METER) POLE AND CREDITING
THE OLD MATERIAL TO STORE
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG
PSC POLE(WITHOUT TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE AND STACKING OF POLE SAFELY ON
ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG
PSC POLE(WITH TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE AND STACKING OF POLE SAFELY ON
ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM AND
45 9926000045 CREDITING FITTING OF ALL ACESSARIES AND FABRICATION KM
TO DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM AND
46 9926000046 CREDITING FITTING OF ALL ACESSARIES AND FABRICATION KM
TO DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM AND
47 9926000047 CREDITING FITTING OF ALL ACESSARIES TO DEPARTMENTAL KM
DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35
48 9926000048 SQ MM AND CREDITING FITTING OF ALL ACESSARIES TO KM
DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ
49 9926000049 MM AND CREDITING FITTING OF ALL ACESSARIES TO KM
DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT DOG ONE
50 9926000050 CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING FIXING OF COND
INSULATORS, BINDING JUMPERING ETC. PER KM
RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT LINES
INCLUDING , BINDING JUMPERING ETC.
LABOUR CHARGE FOR THE INSTALLATION OF NEW DTR
METER. (METER WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR THE REPLACEMENT OF DTR METER
53 9926000053 AND OLD METER SHOULD BE CREDITED TO SDN STORE. No.
(METER WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR METER
CONNECTION. (CT COIL WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF CT COIL FOR DTR
55 9926000055 METER CONNECTION AND OLD CT SHOULD BE CREDITED TO PER CT
SDN STORE. (CT COIL WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR FIXING OF MMB FOR DTR METER (MMB
WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF DTR METER BOX.
(METER WILL BE PROVIDED BY DGVCL)
PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE COPPER
CABLE 3.5 METER (CABLE TO BE PROVIDED BY AGENCY)
LABOUR CHARGE FOR PROVIDING/RECONNECTION OF PER
59 9926000059 TERMINAL CONNECTION WITH PROPER SIZE OF LUGS. (LUGS TERMINA
COST IS BORNE BY AGENCY) TION
LABOUR CHARGE FOR THE SPOT READING OF DTR METER
WITH DETAIL SURVEY OF DEFECT IF ANY. A DULY SIGN COPY
BY SURVEYOR PERSON OF AGENCY IN PRO-FORMA REPORT
60 9926000060 SHOULD BE SUBMITTED TO SDN OFFICE.(* ONLY IF ALL PER DTR
PARAMETER OF VOLTAGE, CURRENT & LOAD AS SHOWN IN
PER-FORMA IS FILLED) AS PER THE INSTRUCTION OF
ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING OF DTR METER
WITH DETAIL SURVEY OF DEFECT IF ANY. A DULY SIGN COPY
BY SURVEYOR PERSON OF AGENCY IN PRO-FORMA REPORT
SHOULD BE SUBMITTED TO SDN OFFICE. (DULY FILL PER-
FORMA IN FAULT CONDITION IN WHICH READING PARAMETER
IS NOT SHOWN IN METER)
INSTALLATION OF DTR METER INCLUDING METER BOX,
PROVIDING & FIXING OF 1.5SQ MM SINGLE STRAND 10 CORE
62 9926000062 ARMOURED COPPER CABLE (3.5METER), TERMINATION IN No.
METER & COIL ETC.(METER, METER BOX, C.T./P.T. COIL WILL
BE PROVIDED BY DGVCL)
INSTALLATION OF DTR METER INCLUDING METER BOX,
TERMINATION IN METER & COIL ETC. (WITHOUT 10CORE
COPPER CABLE) (METER, METER BOX, C.T./P.T. COIL WILL BE
PROVIDED BY DGVCL)
Binding of messanger Conductorat with a distance not more than
64 9926000064 0.75 mtr with 6 turns minimum on XLPE Cable with single strand No
binding wire (including cost of binding wire)
Supply and Installation of 11/22 kV Distribution Transformers HT
65 9926000086 Terminal protector (UV Resistance) with using 95/120/150 sq.mm long PER SET
barrel aluminum lug. (1Set = 3 Nos i.e. on R, Y, B)
Supply & Installation of HT EPR Tap on 11/22 kV Distribution
Transformer with replacement of bare conductor by HT ABC
66 9926000087 conductor (DO bottom side to transformer) after removal of semi PER SET
conductor by HT ABC (6 inch both side). HT ABC to be supplied by
DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
Supply, Installation, Testing and Commissioning of Maintenance Free,
Ready Capsule, Pipe-In-Cage (Pic) Type, Earth Electrodes for HT
67 9926000088 Feeder Pole Having 2000 mm Electrode Length as per the Tender NO
Specifications and Drawing. (All Materials Will Be Supplied By
Supply, Installation, Testing and Commissioning of Maintenance Free,
Ready Capsule, Pipe-In-Cage (Pic) Type, Earth Electrodes for HT
68 9926000089 Feeder Pole Having 3000 mm Electrode Length as per the Tender NO
Specifications And Drawing. (All Materials Will Be Supplied By
Supply and Installation of 25 X 3 mm GI Strip having hot dip-
galvanized-zinc coating of 80-100 microns without any joints or
welding. Both the end of the GI strip should be connected with GI nut
bolts and required fabrication work for giving separate earthing
(1) Neutral of the transformer
(2) MS structures of the transformer center (Approximately 25 meter
GI strip per transformer centre
- as per requirement and instruction of Engineer in- charge) (All
Materials will be supplied by Agency)
Supply and Installation of uPVC standard make Pipe of 1.25" diameter
for covering GI strip with UV protected Cable Ties of 550 X 7.6 mm
70 9926000092 size to bind with pole face(Approximately 25 meter uPVC pipe for GI Meter
strip covering per transformer centre -as per requirement and
instruction of Engineer in-charge.
Supply & fixing of upto 33 kV Conducotr sleev for Busbar to Drop out
Fuse and Drop out fuse to Transformer H.T. including Busbar (12 mm
sleev) as per technical specification. (All Materials will be supplied by
Supply & fixing of upto 33 kV Conducotr sleev for Busbar to Drop out
Fuse and Drop out fuse to Transformer H.T. including Busbar(15 mm
sleev) as per technical specification. (All Materials will be supplied by
Supply & fixing of Disc type Red Color FRP(Non-flammable) material
with Weather resistant, Non-conductive bird guard OD=300 MM,
73 9926000095 ID=33 MM, Width =1.25 MM, one side cut from ID to OD. (All NO
Materials will be supplied by Agency)
Providing and fixing of LT Terminal protectors i.e. Re-useable boot
74 9926000096 (LT Side 1.1 kV) including LT (1.1 kV) insulating taps. All live part at No
LT side shall be covered with fixing of LT insulating taps.
75 Nylon Net around Transformer Center
75.1 9926000097 Nylon Net (12 * 15 ft) Per Net
75.2 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All fabricated material for fitting
nylon net shall be provided by DGVCL)
LABOUR RATES FOR MAINTENANCE WORKS FOR THE
Item Code Details of works Unit FY 2024-25
(A) LINE MAINTENANCE
1 9924000001 Cutting of Tree branches surounding HT/LT line Per Tree
Replacement of old jumpers & providing new double jumpers with 8"
binding [D Type] & capsuling with PVC pipe etc
3 9924000005 Support pole for Stay PSC/STP/RSJ No.
4 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
Pin binding of conductor 11/22kv Pin insulator per pole in costle area
with cleaning .
6 9924000008 Pin binding of conductor LT shakel insulator No.
7 9924000009 Replacement of one/both disc.insulator at strain pole No.
8 9924000010 Replacement of LT shackle insulator at cut point No.
9 9924000011 Refixing of V cross Arm No.
10 9924000012 Replacement of V cross Arm (With Transportation & Painting) No.
11 9924000013 Refixing of Top fitting in proper position No.
12 9924000014 Replacement of Top fitting No.
13 9924000015 Replacement of LT cross Arm No.
14 9924000016 Providing DO fuse on DP with carting & jumpuring(ONE DO FUSE) No.
Numburing of pole with paint by preparing back ground of one colour
and have lettering(height 3" * width 0.5") using stensil
16 9924000018 Fixing of MMB(1PH.) at consumer end No.
17 9924000019 Fixing of MMB(3PH.) at consumer end No.
18 9924000020 Replacement of (1ph.) meter for Urban area No.
19 9924000021 Replacement of (1ph.) meter for Rural area No.
painting consumer no. on MMB (Urban) (with letter size height
40mm* width 8mm)
painting consumer no. on MMB (Rural) (with letter size height 40mm*
22 9924000024 Replacement of deteriorated Single phase Service line No.
Fixing of new dist. Box with complete wiring including clamps,nut bolts
Reparing of guarding involving reshaping of bearer wire cross lacing
25 9924000027 Painting of steel fabricated material of RSJ DO DP structure with paint No.
Painting of steel fabricated material of RSJ pole mounted transformer
double pole structure with paint
27 9924000029 Painting of steel fabricated material of RSJ single pole with paint No.
painting of steel fabricated material of PSC Single pole (HT line) with
painting of steel fabricated material of PSC DO DP double pole with
painting of steel fabricated material of PSC double pole at pole
mounted transformer with paint
31 9924000033 Providing line seperater single phase No.
32 9924000034 Providing line seperater three phase No.
Replacement / Providing of stay insulator along with adjustment of
tension in stay wire
Replacement of deteriorated /providing LT dist. Box with new up to
100KVA capacity & crediting it to store.
Replacement of deteriorated /providing LT dist. Box with new above
100KVA capacity & crediting it to store.
36 9924000038 Adjustment of tension in stay wire No.
37 9924000039 Refitting of LA No.
Converting pin point to Shackle point including dismentaling &
38 9924000040 location
restringing etc.
replacement of 11KV Pin insulator with providing new double pin
replacement of 22KV Pin insulator by new 11kv pin insulator with
spares & providing new double pin binding
41 9924000043 Providing 11kv double disc insulators with binding & restringing No.
Replacement of existing 11kv conductor (all size) with new double pin
43 9924000046 Plumbing of PSC Pole with straightening at pin point No.
44 9924000047 Plumbing of PSC Pole with straightening at tension point No.
Plumbing of tilted DP structure (PSC/RSJ/STP) with refilling of stone
Providing new 11kv AB /GO switch with fabrication and insulated
colour code jumper, binding, lugs etc
Replacement of old 11kv AB /GO switch with providing new insulated
jumper, binding, lugs etc
Providing cage type loop guard in verticle LT line with using PVC reel
48 9924000052 per pole
Labour charges for replacement /providing of MMB & service with all
accessories for three phase connection
Labour charges for replacement /providing of MMB & service with all
accessories for single phase connection
Dismentalling of existing Dist.X'mer center(RSJ /STP POLE)
51 9924000055 25/63/100/200 KVA with all fabrication & creditig the old material to No.
Disconnection from LT pole 1 phase
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
54 9924000058 Disconnection from LT pole 3 phase No.
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
Dismentaling & removing of service line from pole & crediting to S/dn
Dismentaling & removing of service line from pole & crediting to S/dn
58 9924000062 Reconnection of service line complete with PVC cable (1 Ph) No.
59 9924000063 Reconnection of service line complete with PVC cable (3 Ph) No.
Providing spiral type earthing by G.I. NO 8(weight 2kg -5mtr in length)
with salt and coal 10kg each, including pvc rigid pipe 20mm dia(
1.5mtr length) to pass exposed part of G.I. wire at consumer end with
all materials, earth resistance should be less than 2 ohms
Providing and fixing of signle core 1.5 sq mm single strand copper
insulated cable with cable nail clip for spiral type earthing at consumer
end. The end of G.I. no 8 is to be connected by connector with copper
61 9924000070 cable of which other end shall be connected to the earth terminal of per meter
meter box. This item shall be used in location where there is more
distance between earth terminal and earthing terminal of meter. (All
materials supplied by contractor)
LABOUR RATE FOR UNDERGROUND CABLE WORK FOR FY 2024-25 (WITHOUT GST)
Part-B for UG Cable
Item Code Description Unit FY 2024-25
Labour charge for excavation of cable trench of 400mm width x
1200mm depth, in any type of soil for laying of cable of size up to
240 mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered)
Labour charge for excavation of cable trench of 600mm width x
1200mm depth, in any type of soil for laying of cable of size up to
240 mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered)
Labour charge for excavation of cable trench of 400mm width x
1500mm depth, in any type of soil for laying of cable of size up to
240 mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered)
Labour charge for laying of 11kV / 22 kV XLPE Cable of size up to
240 mm2 & preparation of sand layer 100mm thick, in the cable
trench & covering the cable with 150 mm dia (Inner), thickness
mm, 1.0 meter long RCC half round muffs and providing and fixing of
4inch width yellow colour polyethylene tape with printing "CAUTION
ELECTRIC CABLE BELOW" at 0.75 m depth from ground surface
after laying cable in trench. This will provide indication that electric
cable is passing underground so as to protect cable from mechnical
injuries, refilling the same, as per Instruction of Engineer in Charge
Labour charge for horizontal drilling using Auger machine without
damage to surface road at max 2.0 mtrs depth & putting of
kg/cm2 , class-4,Green color, 110mm O.D. , 8.5mm thickness
H.D.P.E. pipe confirms to IS 4984-1987(3rd revision) and BIS
certification and laying of 11KV/22KV XLPE cable of size up to
5 9925000005 mm2 in HDPE pipe, as per Site Condition (excluding cost of pipe). Meter
The detail map obtained from HDD machine and excell sheet(hard
and soft copy) indicating the respective depth and distance from
adjacent landmark for each segment for HDD is must required to be
submitted. HDD to be carried out at depth 1.5 mtrs to 2.0 mtrs as per
site conditions and as per instruction of EIC.
Labour charge for horizontal drilling manually without damage to
surface road at max 2.0 mtrs depth & putting of 6.11 kg/cm2 , class-
4,Green color, 110mm O.D. , 8.5mm thickness H.D.P.E. pipe confirms
to IS 4984-1987(3rd revision) and BIS certification and laying of
11KV/22KV XLPE cable of size up to 240 mm2 size, as per Site
Condition (excluding cost of pipe). The detail map and excell
sheet(hard and soft copy) indicating the respective depth and distance
from adjacent landmark for each segment of cable to be submitted.
Drilling to be carried out at depth Minimum 1.2 mtrs to 2.0 mtrs as per
site conditions as per instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5 mm
7 9925000007 thickness H.D.P.E. pipe confirms to IS 4984 and BIS certification for Meter
laying of underground 11KV / 22KV XLPE cable up to 240 mm2 size.
Labour work for RCC concreting on disputed location and repairing of
damage portion of road crossing for the work carried out for roads
crossing as well as concreting & muffing of ploes including all
materials (1:2:4)
Providing & fixing concrete stone route marker of 300 mm width x
150 mm thick x 650 mm height embedded in earth at least 300 mm
below & 350 mm above ground level respectively at distance approx
50 meters along the length of cable. The RCC concreting (1:2:4)(all
necessary maeterials will be in bidder's scope) of route marker is to be
carried out 300 mm width x 150 mm thick x 300 mm below ground
level as per instruction of EIC. The route marker should be with
name of company with approved yellow colour-DGVCL. The distance
from marker to cable and cable depth with feeder name etc., marked
with arrow sign is to be painted on it.The route marker is to be fixed at
location near to any fixed permanent location (not necessary to fix
exact on top of cable) as per instruction of EIC.
Erection of D.P. (double pole) structure using 9 / 11 Mtr. RSJ pole
with cable connection arrangement along with fitting of necessary
10 9925000010 fabrication for 11KV cable including excavation of pit & refilling of No.
earth as per instruction of EIC. (Exclusive of concreting & muffing of
Erection of Single pole structure using 9 / 11 Mtr RSJ pole with
cable connection arrangement along with fitting ofnecessary
11 9925000011 fabrication for 11KV/22 KV cable including excavation of pit & refilling No.
of earth as per instruction of EIC. (Exclusive of concreting & muffing of
Erection of D.P. (double pole) structure using 8.0 Mtr. PSC pole
with cable connection arrangement along with fitting of necessary
12 9925000012 fabrication for 11KV cable including excavation of pit & refilling of No.
earth as per instruction of EIC. (Exclusive of concreting & muffing of
Erection of Single pole structure using 8.0 Mtr PSC pole with cable
connection arrangement along with fitting ofnecessary fabrication for
11KV/22 KV cable including excavation of pit & refilling of earth as per
instruction of EIC. (Exclusive of concreting & muffing of poles)
Labour charge for erecting of 11kV / 22 kV XLPE cable of size up to
14 9925000014 240 mm on DP Structure with fixing of 02 Nos polymer cleats on Per Job
top and middle part.Polymer cleats, nut bolts etc. fixing material to
be provided by contractor.
Providing & fixing of 6.11kg/cm2 , class-4,Green color, 110mm O.D.
, 8.5mm thickness H.D.P.E. pipe confirms to IS 4984 and BIS
certification on the erected DP structure for the mechanical
protection of cable by inserting the cable inside HDPE pipe. The
HDPE pipe shall be erected in such a way that 300mm shall be below
the ground level and the rest 2700 mm shall be supported on the
DP Structure with 01 No Polymer cleat.All materials including polymer
cleat and Nut bolt to be provided by contractor.
Providing and fixing of pipe type earthing from 80 mm dia class-B GI
pipe with pit to be filled with salt & coke and construction of chamber
16 9925000016 as per DGVCL Drg. No. dg /100 for DP and cable. The earthing pit No.
should be joined with cable by G.I. strip of size 1” width & 2 mm thick.
All material GI pipe, Coke, Salt etc will be supplied by bidder.
Supply & fixing of heat shrink type end terminations (outdoor) for
17 9925000017 upto 11kV 3C x 185 mm2 size XLPE cable as per DGVCL technical No.
Supply & fixing of heat & shrinkable end terminations (outdoor) for
18 9925000018 upto 22 kV 3C x 185 mm2 size XLPE cable as per DGVCL technical No.
Supply & fixing of heat shrink type end terminations (indoor) for
19 9925000019 upto 11kV 3C x 185 mm2 size XLPE cable as per DGVCL technical No.
Supply & fixing of heat & shrinkable end terminations (indoor) for
20 9925000020 upto 22 kV 3C x 185 mm2 size XLPE cable as per DGVCL technical No.
Supply & fixing of heat shrinkable straight through joint for upto
21 9925000021 11kV 3C x 185 mm2 size XLPE cableas per DGVCL technical No.
Supply & fixing of heat shrinkable straight through joint type for
22 9925000022 upto 22kV 3C x 185 mm2 size XLPE cable as per DGVCL technical No.
Labour charge for excavation of 2100mm long x 1200mm wide x
1200 mm deep joint pits for installation of 11kV / 22kV Straight
23 9925000023 through joints as per instruction of engineer-in-charge & covering the No.
cable with 150 mm dia (Outer), thickness 25 mm, 1.0 meter long
RCC half round muffs & refilling same as per instruction of EIC .
Providing and fixing of insulating bus bar, made from 11KV/22KV
XLPE cable after removal of semi conducting layer and applying of
PVC heat shrinkable anti-tracking core insulating tubing (1.1KV), on
both end terminal using Aluminium long barrel heavy duty up to
24 9925000024 sq mm lugs, Aluminium bus connector. Taping with PG- clamp for bus No.
conductor as per drawing and as per instruction of EIC. The
Alluminium lugs and PG clamp shall be covered with 11KV/22KV HT
insulating tapes.(11KV/22KV XLPE cable will be in scope of DGVCL
while all other materials will be in bidder's scope)
Testing of cable at various points and commissioning the feeder as
25 9925000025 per instruction of engineer-in-charge.Test result shall be submitted by No.
contractor with bill.
Preparation and submission of 6 (six) copies, of complete layout
26 9925000026 drawings with GIS mapping as per actual cable routing showing Set
road crossing, HDPE pipe sleeving, jointing locations, markers etc.
Providing and fixing of Sign Board at junction point Made out of 2 mm
aluminium sheet size 750x300 mm (2.5 x 1ft) rectangle, as per design,
pre treated with phosphate process and acid etching coated with one
coat of epoxy primer and two coats of best quality paints,
refloctrorised with Hi-Intensity retro – reflective sheeting as per the
latest and frame fabricated from suitable size iron angle. The Sign
Board is to be fixed on the base prepared from channel and bracing
angles which is grouted by means of cement concreting of 1:2:4 for
size of 300 mm dia x 800 mm height (500 mm to be grouted in
ground). The details to be displayed on sign board will be given by In-
charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing and fixing of Sign Board (Danger Board) on Distribution
Transformer Centers
Made out of 2mm aluminium sheet size 300x300mm (1x1ft) as per
design, pre treated with phosphate process and acid etching coated
with one coat of epoxy primer and two coats of best quality paints,
refloctrorised with Hi-Intensity retro-reflective sheeting as per the
latest and frame fabricated from suitable size iron angle. The Sign
Board (Danger Board is to be fixed at the location as per instruction of
In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing & fixing of aluminium tag of size 250 mm (L) x 75 mm (W)
from 3 mm aluminium sheet along with 1.0 mm dia aluminium binding
wire for fixing of aluminium tag near end termination joint at DP
structure for identifyng the cable. The details of feeder i.e. 11 / 22 KV
with feeder name shound be punched on the tag by letter punch of
size 16 mm as per instruction of In-charge Engineer.
Supply & fixing of heat shrink type end terminations (outdoor) for
30 9925000030 11kV 3C x 240 mm2 size XLPE cable as per DGVCL technical No.
Supply & fixing of heat & shrinkable end terminations (outdoor) for
31 9925000031 22 kV 3C x 240 mm2 size XLPE cable as per DGVCL technical No.
Supply & fixing of heat shrink type end terminations (indoor) for
32 9925000032 11kV 3C x 240 mm2 size XLPE cable as per DGVCL technical No.
Supply & fixing of heat & shrinkable end terminations (indoor) for
33 9925000033 kV 3C x 240 mm2 size XLPE cable as per DGVCL technical No.
Supply & fixing of heat shrinkable straight through joint for 11kV 3C
x 240 mm2 size XLPE cableas per DGVCL technical specification.
Supply & fixing of heat shrinkable straight through joint type for
35 9925000035 22kV 3C x 240 mm2 size XLPE cable as per DGVCL technical No.
Installation, Testing and commissioning of 11 KV,630 A SCADA
Compatible, RRL type- 3 Way RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of 11 KV,630 A SCADA
Compatible, RRLL type- 4 Way RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A SCADA
Compatible, RRL type-3 Way, RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A SCADA
Compatible, RRLL type-4 Way, RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Construction of plinth for 11KV, RRL type- 3 Way (i.e Two
numbers of Isolator & One number of Breaker) Ring Main Unit as per
DGVCL's technical specification mentioned in drawing no: Drg. 11kv-
01. All required material will be supplied by contractor.
Construction of plinth for 11KV, RRLL type- 4 Way (i.e Two
numbers of Isolator & Two number of Breaker)Ring Main Unit as per
DGVCL's technical specification mentioned in drawing no:Drg. 11kv-
02.All required material will be supplied by contractor.
Construction of plinth for 22KV, RRL type- 3 Way (i.e Two
numbers of Isolator & One number of Breaker) Ring Main Unit as per
DGVCL's technical specification mentioned in drawing no: Drg. 22kv-
01. All required material will be supplied by contractor.
Construction of plinth for 22KV, RRLL type- 4 Way (i.e Two
numbers of Isolator & Two number of Breaker)Ring Main Unit as per
DGVCL's technical specification mentioned in drawing no:Drg. 22kv-
02.All required material will be supplied by contractor.
Modifications e.g.Providing and fixing of Terminal protectors i.e. Re-
use able boot (HT Side 11/22KV, LT Side 1.1KV) including 11/22 KV
insulating taps and L.T.(1.1 KV) insulating taps ,Busbar, Tapping
from Bus Bar (11/22 KV XLPE cable) through P.G. Clamp for H.T.
Jumper to D.O. Fuse to bushings of Transformer Center, providing &
Fixing of jumper and providing & fixing of Heat Shrinkable Anti
Tracking Core Insulating Tubing (Insulation Level 11/22 KV) in H.T.
jumper , Clamping arrangement of cable support frame on both side of
44 9925000046 existing Over Head type Distribution Transformer to utilize in Under No.
Ground cable network as per drawing & as per instruction of Engineer
incharge. All live parts i.e. PG-Clamp, connections of D.O.fuses, HT
bushings etc . shall be covered with fixinng of 11/22 KV HT insulating
tapes. ( 11/22 KV XLPE cable will be in scope of DGVCL while all
other materials will be in bidder's scope ) .
Laying of any size of 11/ 22 KV XLPE /PILC Cable in redaymade Per Cable
trench or in open space Per Mtr
46 9925000060 Labour charges for Lying of O/H XLPE cable pole to pole KM
Supply of 150 mm dia (Inner), thickness 25 mm, 1.0 meter long RCC
half round pipe
In Words : - Thirty Lakh Rupees Only
% Above/Below of Estimate Amount
Stamp & Sign of Contractor
Executive Engineer (O&M)
DGVCL, Rander Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. 30LAKH HT LT TC AND UG CABLE WORK TENDER.pdf
2. T-1-T-2-PAL-ADJ-RAM-PALA SDN Bid Document.pdf
3. T-1-T-2-PAL-ADJ-RAM-PALA SDN Detail Tech Specification.pdf
4. Erection and Maintenance for Technical Specification.pdf
5.RT-1-T-2-ADJ-PAL-RAM-PALA Schedule-b.pdf
6. Reference Bid Drawing.pdf
7.UG CABLE TENDER IMP POINTS.pdf
8. Utilization of pole erection device.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .