Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
8 Nov 2021, 6:00 pmClosed
Executive Engineer,Minor Irrigation Division, Mal
Executive Engineer Minor Irrigation Division B1 Block Civil Station Malappuram 676505
RLIS-Construction of new building of LIS Thrikkanapuram in Thavanur Grama Panchayath -Malappuram District-Electrification and providing HT Installation Re E Quotation
2021_Irrig_422435_2
EEMI/EQ/02/2021-22
Open Tender
Electrical Works
Item Rate
180 days
Thrikanapuram
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹50,000
15 Mar 2022
1 Nov 2021
11 Nov 2021
1 Nov 2021
8 Nov 2021
1 Nov 2021
Amount
Light Wiring
90.2.1.1Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Controllight point with 6A, plate ceiling rose - Short point
90.2.1.3Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single controllight point without ceiling rose - Short point
90.2.1.6Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combinedplug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of lightpoints
90.2.1.4Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single controlceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short poin
90.3.21.3Supply & installation of light fittings on 'C/U' shaped flat iron bracket<br>Supply, conveyance, installation,testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet completewith all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MSflat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copperconductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc.as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.20.3Supply & installation of light fittings on TW round block<br>Supply, conveyance installation testing andcommissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with allaccessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit thefitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wireconforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box typefixture
90.15.4.1Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factorgreater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-castPowder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatlyaccessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be producedmentioning chip manufacturer)
90.15.4.2Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greaterthan 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with powerfactor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-castPowder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatlyaccessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be producedmentioning chip manufacturer)
90.3.18.1Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut andwelded to shape and fixing the same to wall / parapet using clamps as noted along with each size,painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good thedamages, colour washing etc as required.25 mm dia with HG company fabricated clamps
od23149/2019_2020/IASupply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminiumbody, epoxy powder coated, heat resistant prismatic glass cover suitable for 5/7 W LED to wall / ceilingincluding giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 coreround copper conductor flex wire conforming to relevant ISS or extending the original wiring and makinggood the surface as required including 5/7 w W LED lamp.
od8568/2020_2021/IASupply and fixing angle / straight brass lined skirt type, bakelite batten holder with 200 mm polishedplastic shade and 7 W LED bulb including giving connection etc as required
90.4.5.2Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes usingstandard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVCinsulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extendedoriginal wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod ,canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C
90.4.1Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required
od23151/2019_2020/IASupply, conveyance, installation, testing& commissioning of Exhaust fans of size 300/305 mm in theexisting opening fixing necessary anchor bolts and nuts etc. as required including giving connection withthe supplied wire along with the fan
90.4.8Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep includingplastering colour washing etc. as required.
1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.3 Module (100mmX75mm)
1.28.2Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. asrequired.3 Module
1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.15/16 amp switch
od23094/2019_2020/IASupply and Fixing the following modular switches & accessories in the existing front plates and givingnecessary connections as required (RoHS compliant )<br>16A 3pin Shuttered socket
90.11.1.18Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure ofMCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DBwith provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12way, Double door
2.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required.63 amps
2.15.3Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual currentcircuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.63 amps
2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB completewith connections, testing and commissioning etc. as required.40 amps
2.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrentcircuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.40 amps
2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole
od28468/2019_2020/IASupplying and fixing 50 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required.<br>Triple pole
2.11Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Panel Board-MSB
90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dustand vermin proof, cubicle type MV panel board comprising of the following components/ devices &complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panelassembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved designand requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gearcompartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outsfor mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus barchamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for thefabrication of panel assembly. The measurments will be taken the area of the complete sheets used forpanel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. includingrequired nut & bolt etc.
90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beedingsuitable for 1.60/ 2.00 mm sheet
90.14.6Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber,suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7Supply and providing copper earth bus in the panel board
90.14.4Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolledsteel channel (ISMC)
90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panelboard
90.14.10.18Supply, conveyance and fixing the following types & current rated control gears & switchgearsconforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly asrequired.630A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor basedrelease with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.3Supply, conveyance and fixing the following types & current rated control gears & switchgearsconforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly asrequired.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal settingrange of 80 - 100% with thermal magnetic release having adjustable OL
90.14.10.6Supply, conveyance and fixing the following types & current rated control gears & switchgearsconforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly asrequired.125A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor basedrelease with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.9Supply, conveyance and fixing the following types & current rated control gears & switchgearsconforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly asrequired.250A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor basedrelease with overload setting of 50 - 100% having adjustable OL & SC
90.14.11.4MCCB AccessoriesSupply and fixing one number earth fault Relay up to 630A to 800A with CBCT
90.14.11.7MCCB AccessoriesSupply and fixing 630 - 800A earth fault module of MCCB requiring external CBCT.
90.14.11.15MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with doorinterlock ) in the existing MCCB of rating up to 315-630 A
90.14.11.5MCCB AccessoriesSupply and fixing 100 - 200A earth fault module of MCCB with builtin CBCT.
90.14.11.6MCCB AccessoriesSupply and fixing 250 - 400A earth fault module of MCCB with builtin CBCT.
90.14.11.12MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
90.14.11.13MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with doorinterlock ) in the existing MCCB of rating up to 250 A
90.14.11.9MCCB AccessoriesSupply and fixing auxiliary switch (1 NO + 1 NC) in the existing MCCB of rating up to630 A.
90.14.11.11MCCB AccessoriesSupply and fixing one number under voltage release for all voltage range up to 630AMCCB
90.14.11.17MCCB AccessoriesSupply and fixing kastel interlock kit up to 250A.
od23072/2019_2020/IASupply and fixing Three phase volt meter (V - RY, YB, BR, R, Y, B) of accuracy class 1
od23066/2019_2020/IA Supply and fixing Three phase ammeter (A - R, Y, B) of accuracy class 0.50
od23054/2019_2020/IASupply & fixing 200/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5
od23074/2019_2020/IASupply and providing LED indicators for all voltage ranges - Blue colour LED indicator, AC/DC, 22.5 mmcut out dia.
od23076/2019_2020/IASupply and providing LED indicators for all voltage ranges - Red, Green, Black,<br>Yellow or OrangeColour
od23080/2019_2020/IAAluminium anodised Danger Notice Board of size 150 x 100 mm. with inscriptions ( both in English andMalayalam) and conventional Skull and Bone in Red colour.
od23082/2019_2020/IASupply and fixing 2 A( C curve),SP MCB (C curve)(for control wiring protection)
od23084/2019_2020/IACarrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 Vgrade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 forinterconnecting the control devices/ equipments including providing suitable size insulated sockets at thetermination points or soldered properly, providing numbering ferrules for the proper identification of thewiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.1.5 sqmm single runwith required socket
Panel Board(SSB1,SSB2,SSB3,SSB4 &SSB5)
90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dustand vermin proof, cubicle type MV panel board comprising of the following components/ devices &complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panelassembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved designand requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gearcompartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outsfor mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus barchamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for thefabrication of panel assembly. The measurments will be taken the area of the complete sheets used forpanel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beedingsuitable for 1.60/ 2.00 mm sheet
90.14.7Supply and providing copper earth bus in the panel board
90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panelboard
od24274/2019_2020/IAProviding and fixing 250 Amp TP&N Isolator unit inside the existing panel board , including drilling holesin cubicle panel, making connections, etc. as required
od24275/2019_2020/IAProviding and fixing 125 Amp TP&N Isolator unit inside the existing panel board , including drilling holesin cubicle panel, making connections, etc. as required.
od24276/2019_2020/IAProviding and fixing 63 Amp TP&N Isolator unit inside the existing panel board, including drilling holes incubicle panel, making connections, etc. as required.
od23063/2019_2020/IASupply & fixing 100/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5
od23066/2019_2020/IA Supply and fixing Three phase ammeter (A - R, Y, B) of accuracy class 0.50
od23072/2019_2020/IASupply and fixing Three phase volt meter (V - RY, YB, BR, R, Y, B) of accuracy class 1
od23074/2019_2020/IASupply and providing LED indicators for all voltage ranges - Blue colour LED indicator, AC/DC, 22.5 mmcut out dia.
od23076/2019_2020/IASupply and providing LED indicators for all voltage ranges - Red, Green, Black,<br>Yellow or OrangeColour
od23080/2019_2020/IAAluminium anodised Danger Notice Board of size 150 x 100 mm. with inscriptions ( both in English andMalayalam) and conventional Skull and Bone in Red colour
od23082/2019_2020/IASupply and fixing 2 A( C curve),SP MCB (C curve)(for control wiring protection)
od23084/2019_2020/IACarrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 Vgrade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 forinterconnecting the control devices/ equipments including providing suitable size insulated sockets at thetermination points or soldered properly, providing numbering ferrules for the proper identification of thewiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.1.5 sqmm single runwith required socket
90.14.24.20Supply & fixing the following Power Capacitors 3 phase delta connected in positon and givingconnection.5 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor,Box Type, suitable for direct connection to motors.
90.14.24.24Supply & fixing the following Power Capacitors 3 phase delta connected in positon and givingconnection.12.5 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly PropyleneCapacitor, Box Type, suitable for direct connection to motors
90.14.24.26Supply & fixing the following Power Capacitors 3 phase delta connected in positon and givingconnection.20 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly PropyleneCapacitor, Box Type, suitable for direct connection to motors
od24349/2019_2020/IASupply,installation,testing & commissioning of Heavy duty Motor starters of the following ratings<br>Fullyautomatic star delta starter for 15 HP moto
od24350/2019_2020/IASupply,installation,testing & commissioning of Heavy duty Motor starters of the following ratings<br>Fullyautomatic star delta starter for 40 HP motor
od24368/2019_2020/IAsupply ,installation ,tesing & Commissioning of 40 HP oil immersed stator rotor starter with separate OCB( with out oil) suitable for rotor amperes
od24369/2019_2020/IAsupply ,installation ,tesing & Commissioning of 100 HP oil immersed stator rotor starter with separateOCB ( with out oil) suitable for rotor amperes
od24370/2019_2020/IAsupply ,installation ,tesing & Commissioning of jyothi brand/unitech/equilent make 100 HP fully automaticoil immersed auto transformer starter with out oil
od24371/2019_2020/IASupply, conveyance and filling of good quality LT grade transformer oil
Meter Board
90.14.1.1Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dustand vermin proof, cubicle type MV panel board comprising of the following components/ devices &complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panelassembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved designand requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gearcompartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outsfor mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus barchamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for thefabrication of panel assembly. The measurments will be taken the area of the complete sheets used forpanel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using2.00mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. includingrequired nut & bolt etc.
90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beedingsuitable for 1.60/ 2.00 mm sheet
90.14.7Supply and providing copper earth bus in the panel board
od28471/2019_2020/IAAluminium anodised Danger Notice Board of size 150 x 100 mm. with inscriptions ( both in English andMalayalam) and conventional Skull and Bone in Red colour.
90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panelboard
Cable Laying
90.12.5.36Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe asrequired.3.5 core 300 sq mm
90.12.9.7Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out ofHDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with allrequired accessories in ground in the existing trench120/102.5 mm or nearest size
90.12.7.28Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium powercable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clampsnot exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mmwith factory made clamp
90.12.7.34Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium powercable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clampsnot exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
90.12.7.36Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium powercable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clampsnot exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm
90.12.41.34Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable,1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps notexceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm withfactory made clamp
90.12.41.33Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable,1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps notexceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm withfactory made clamp
9.1.27Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.3 1/2X 185 sq. mm (57mm)
9.1.21Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.3 1/2X 35 sq. mm (32mm)
9.1.30Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.3 1/2X 300 sq. mm (70mm)
9.1.33Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.4 X 16 sq. mm (28mm)
9.1.32Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.4 X 10 sq. mm (25mm)
od23070/2019_2020/IASupply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductorcables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes 120.00 sq.mm 3 Run
od23075/2019_2020/IASupply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductorcables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.120.00 sq.mm 6 Run
od24520/2019_2020/IASupply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductorcables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.25 sq.mm 3 Run
od24521/2019_2020/IASupply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductorcables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.25 sq.mm 6 Run
90.6.4.53Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductorcables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.10.00 sq.mm 3 Run
90.6.4.56Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductorcables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.10.00 sq.mm 6 Run
1.17.11Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.20Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
od28503/2019_2020/IASupply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper Control cable,of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms,making good the damages , colour washing etc. as required.<br>12 core 2.5 sq mm with factory madeclamp<br>
90.12.24.11Supply of superior quality copper tubular cable socket and making core termination of cables of thefollowing sizes including crimping etc. as required.120 sq mm
90.12.24.4Supply of superior quality copper tubular cable socket and making core termination of cables of thefollowing sizes including crimping etc. as required.10 sq mm
90.12.24.6Supply of superior quality copper tubular cable socket and making core termination of cables of thefollowing sizes including crimping etc. as required.25 sq mm
90.12.24.1Supply of superior quality copper tubular cable socket and making core termination of cables of thefollowing sizes including crimping etc. as required.2.5 sq mm
90.12.24.2Supply of superior quality copper tubular cable socket and making core termination of cables of thefollowing sizes including crimping etc. as required.4 sq mm
od28490/2019_2020/IASupplying and fixing of 63/50 mm DWC pipe along with accessories in surface/ recess including cuttingthe wall and making good the same in case of recessed conduit as required.
od28491/2019_2020/IASupplying and fixing of 77/63 mm DWC pipe along with accessories in surface/ recess including cuttingthe wall and making good the same in case of recessed conduit as required
90.6.10.1Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recessincluding cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.3Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recessincluding cutting the wall and making good the same in case of recessed conduit as required32 mm
od29032/2019_2020/IASupplying and fixing of 20 mm Corrugated PVC flexible conduit along with accessories in surface/ recessincluding cutting the wall and making good the same in case of recessed conduit as required.
od23086/2019_2020/IASupplying and installation including all manner of supports/ suspenders, anchor bolts etc for cable traysmade out of suitable size channel sections, slotted angles, flats, MS plates etc as required includingpainting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good thedamages, colour washing etc as required.
Earthing
od28935/2019_2020/IAEarthing with G.I. earth plate 1200 mm X 1200 mm X 12.5 mm thick including accessories, and providingmasonry enclosure with 450x450x10mm cover plate and watering pipe of 3 metre long etc. with charcoal/coke as required.<br>
od28938/2019_2020/IASupply and providing the following sizes of cast iron gully trap with covering at the top of the inspectionchamber of earth pit as required . - 300 x 300 x 10 mm cast iron gully trap with covering
od28939/2019_2020/IAProviding and fixing 32 mm X 6 mm G.I. strip earth lead from the test joint to the earth plate
od28940/2019_2020/IAProviding and fixing 2X 32 mm X 6 mm G.I. strip test joint for earthing system
5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andprovidingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/ coke and salt as required.
90.16.1.1Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.5Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required4.75 mm copper conductor (6 SWG)
90.16.1.6Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required6.00 mm copper conductor (4 SWG)
90.16.3.5Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray usingclamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing ofclamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontalrun)32 x 6 mm GI strip
90.16.3.9Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray usingclamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing ofclamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontalrun)25 x 3 mm copper strip
90.16.5.1Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.2.00 mm (14 SWG)
90.16.5.3Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.3.15 mm (10 SWG)
90.16.5.5Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.4.75 mm (6 SWG)
90.16.5.6Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.6. mm ( 4 SWG)
od28941/2019_2020/IASupplying and laying 32 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode,including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall bedone by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)<br>
od23088/2019_2020/IASupply and providing the following sizes of bolt and nut with washers on the existing MS box / earth busetc. as required including drilling necessary holes as required - 25 x 6 mm brass bolt & nut
od23091/2019_2020/IASupply and providing the following sizes of bolt and nut with washers on the existing MS box / earth busetc. as required including drilling necessary holes as required - 25 x 3mm brass bolt & nut.
od23092/2019_2020/IASupply and providing the following sizes of bolt and nut with washers on the existing MS box / earth busetc. as required including drilling necessary holes as required - 12 x 3mm brass bolt & nut.
HT Installation
od28523/2019_2020/IA Fabrication, Supply and Erection of 11 KV 4 pole structure as per standards made out of ISMB 175x85mm joist of 10mtrs. Length and cross members of ISMC 100x50mm MS channels the post has to be fixed 1.6M below ground level using 1:3:6 coment concrete as per standard including painting with 2 coats of aluminium paint over 2 coats of red oxide primer 600x600x10mm MS plate shall be welded to all poles as base plate. including fixing suitable bolts and nuts etc. complete and the pole structure, including '0' SWG solid copper conductors shall be used for all jumber connections from suppliers AB switch to transformer through various equipments
13.1 Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mmdia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stayclamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulatoretc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mmnominal size ) foundation including excavation and refilling etc. as required.
od28530/2019_2020/IA Supplying and erection of 11 KV, DO Fuse suitable for 3 wire. 11 KV overhead lines and complete with galvanized clamping arrangement, G.I. bolts, nuts, washers etc. as required.
13.13 Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire. 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KSA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as require
13.10 Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
13.11 Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
od28622/2019_2020/IA Supplying and erection of 11 KV, 400A GO AB Switch suitable for 3 wire. 11 KV overhead lines and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
od28623/2019_2020/IA Supply,Conveyance,installation, testing and commissioning of 11kV/433V , 315 KVA Oil Cooled Transformer (As per IS 1180 Level -2) , ON type 11000/433V, 50Hz delta/star connected copper wound oil filled Natural cooled , Laser scribed core type out door minimum IP 65/66 protection attached transformer with bushing on HT side cable box with provision for terminating suitable size AYFY cable on LT side, first fill of transformer oil, offload tap changer +5% in steps of 2.5% with all standard fittings on the existing plinth conforming relevant ISS and its latest amendment
od28630/2019_2020/IA Supply, Erection, Testing and Commissioning of outdoor oil filled CTPT unit with bushing as per KSEB standard consist of following: CT Ratio - -/5A 15 VA Class - 0.2 S CTs 3 Nos 11KV/110V 100VA 0.2 S CLASS PT: 1 Nos.CTPT unit incuding cost of transformer oil as per KSEB standards and including testing at KSEB TMR unit
od28634/2019_2020/IA Supply, Erection, and Commissioing of -/5A, class 0.2 S, 11KV/110V 4 wire HT TOD meter with terminal block and 20A fuse with HRC Link including testing TOD meter.
od28708/2019_2020/IA Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc,as required, In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works, for HT fencing<br>
od28709/2019_2020/IA Painting with synthetic enamel paint of approved brand and manufacture to give an even shade - For HT Fencing painting
od28710/2019_2020/IA Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand) With F.P.S. ( non modular ) bricks(from floor 2 level up to floor 5 level) CPWD code 6.3.1
od28711/2019_2020/IA 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
od28712/2019_2020/IA Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level <br>Thermo - Mechanically Treated bars
od28713/2019_2020/IA Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers
od28714/2019_2020/IA Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
od28715/2019_2020/IA Providing and laying in position graded stone aggregate 40 mm nominal size in transformer yard etc as required.
od28721/2019_2020/IA Providing and fixing (0 SWG) copper wire Net
od29012/2019_2020/IA supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.- 0 SWG
Miscallaneous Items
od29013/2019_2020/IASupply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps includingfixing it to wall as required.
od29014/2019_2020/IASupply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of redoxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with finesand, painting the bracket/ floor stand including making good the damages, colour washing etc. asrequired.
od29015/2019_2020/IASupply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
od29016/2019_2020/IASupply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 towithstand 3.3 KV dielectric strength.
od29017/2019_2020/IAPainting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panelboard etc as required- 2.50 cm, 4 cm or 5 cm height
od29020/2019_2020/IA Charges for preparation of scheme for the Electrical Installation for sheet of A3 size.
od29021/2019_2020/IAFor additional copies of scheme for the Electrical Installation for sheet of A3 size.
od29022/2019_2020/IAFee to be paid to KSELB towards scrutiny & inspection/KSEB testing charges etc
od62407/2019_2020/IASupply of Tools - 1) Electrical grade Rubber Gloves - 2 Pair. 2) Neon Tester - 5 Nos. 3) 300 mm Screwdriver-2 Nos 4).200 mm Combination pliers - 2 Nos. 5).3 cell Torch with cells - 2 Nos. 6).Ring spanner 12pieces set. 2 sets. 7).Double end spanner 12 pieces - 2 sets 8).Adjustable spanner 305 mm - 2 Nos 9).15Ltr capacity aluminium bucket - 4 Nos 10). First Aid Box with essential medicine, cotton ,plaster,1 noscissors etc.- 2 Nos
Motor Pump set Maintenance
od56013/2019_2020/IA Dismantling the 6-25 HP motor into stator and rotor, cleaning the windings attending minor repairs, retaping the coils if necessary, varnishing the coils with best quality insulation varnish, cleaning andgreasing the bearings with good quality grease, heating the windings, reassembling, test runningincluding scrapping, cleaning and painting with enamel paint.
od56014/2019_2020/IADismantling the 40-50 HP motor into stator and rotor, cleaning the windings, attending minor repairs,retaping the coils if necessary, varnishing the coils with best quality insulation varnish, cleaning andgreasing the bearings with Lithium base grease, heating and baking the windings, reassembling, testrunning including scrapping, cleaning and painting with 2 coats of Grey enamel paint.
od56026/2019_2020/IADismantling the 76HP -100HP motor into stator and rotor, cleaning the windings, attending minor repairs,retaping the coils if necessary, varnishing the coils with best quality insulation varnish, cleaning andgreasing the bearings with Lithium base grease, heating and baking the windings, reassembling, testrunning including scrapping, cleaning and painting with 2 coats of Grey enamel paint.
od56016/2019_2020/IADismantling the pump,taking out the impeller shaft assembly,removing any foreign materials from thepump,cleaning,checking the impeller leaves,supply and providing fresh gland packing greasing thebearings etc of 100HP-125HP pump scraping cleaning painting with two coats of best enamel paint
od56018/2019_2020/IADismantling the pump,taking out the impeller shaft assembly,removing any foreign materials from thepump,cleaning,checking the impeller leaves,supply and providing fresh gland packing greasing thebearings etc of 30-50 HP pump scraping cleaning painting with two coats of best enamel paint
od59252/2019_2020/IASupply &changing damaged bearing of 6-25 HP motor of No,equivalent or nearest 6308
od59253/2019_2020/IASupply &changing damaged bearing of 76-100 HP motor of No,equivalent or nearest 6319C3
od59256/2019_2020/IASupply &changing damaged bearing of 40-50 HP motor of No,equivalent or nearest 6313/C3
od59264/2019_2020/IASupply & changing suitable bearing for damaged bearing of 76-100 HP sulzer pump
od59265/2019_2020/IASupply &changing suitable bearing of 40-50HP sulzer pump
od59271/2019_2020/IASeperate the motor in to stator and rotor , remove the whole burnt stator coil by cutting, pulling andcleaning the slots.Insulating the slots by using nomex paper, rewinding the complete stator slots by usingsame gauge new copper super enameled winding wire and taping coils.Providing new lead wires,sockets etc.Varnishing the coil using best quality insulation varnish and baking the coils, reassemblingand test run the motor.(Less the cost of scarp copper wire)
Bidder Name
KEYAS ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .