Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Admitted |
Tender Value
₹1.2 Cr
EMD Value
₹50,000
Closing Date
4 May 2026, 11:15 amClosed
Chief Engineer, KIIDC
Kerala Irrigation Infrastructure Development Corporation Ltd., KWA Campus, Vellayambalam, Thiruvananthapuram
This proposal is about providing CMI in the ayacut areas of Chinnar River in Idukki District an area of 30 acres of land would be brought under irrigation.
2026_KIIDC_841429_2
IRR/KIIDC/TR/1148/2026_5_1_1/1
Limited
Civil Works - Lift Irrigation Schemes
Item Rate
180 days
Idukki
Please refer tender document
6 documents required · 6 mandatory
₹6,508
₹50,000
3 Sept 2026
12 Mar 2026
6 May 2026
12 Mar 2026
4 May 2026
12 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing Submain Works | |||||
| 1.001 | OD50664/2025-2026:DESIGN, SUPPLY, INSTALLATION, TESTING, AND COMMISSIONING OF
SUB-MAIN MICRO-IRRIGATION SYSTEM AS PER THE IS SPECIFICATIONS
AND APPROVED DESIGN FROM KIIDC DESIGN WING INCLUDING ALL
SUBMAIN PVC PIPELINES-IND, PLACING EMITTER TAKE-OFF AND
FITTINGS, ACCESSORIES, FLUSH VALVES, IRRIGATION CONTROL
VALVES, AND FITTINGS AND ACCESSORIES, SUPPLY OF SPARE PARTS,
TOOLS ETC WITH ALL COST OF MATERIALS, LABOUR CHARGES, COST OF
FITTINGS, CONVEYANCE INCLUDING ALL COST OF TRENCHING,
BACKFILLING, AND LAYING AS PER DESIGN ALIGNMENT AND LEVELS,
IF ANY, ETC, INCLUDING MATERIAL TEST REPORT FROM THE
THIRDPARTY
QUALITY CONTROL UNIT, AS PER THE SPECIFICATIONS AND
DIRECTIONS OF DEPARTMENTAL OFFICERS AT SITE. | 3,000 | cent | - | - |
| 2Providing Mainline works | |||||
| 2.001 | OD50665/2025-2026:DESIGN, SUPPLY, AND INSTALLATION, TESTING AND COMMISIONING OF MAINLINE MICRO-IRRIGATION SYSTEM AS PER THE IS SPECIFICATIONS AND
APPROVED DESIGN FROM KIIDC INCLUDING MAIN LINE PVC FERTIGATION
UNIT(UV PROTECTED), IRRIGATION CONTROL VALVES & PRV FOR MAINLINE,
FITTINGS AND ACCESSORIES, SUPPLY OF SPARE PARTS, TOOLS,PRESSURE
TESTING OF LAID PIPE LINES ETC WITH ALL COSTS OF MATERIALS, LABOUR
CHARGES, COST OF FITTINGS, CONVEYANCE INCLUDING ALL COSTS OF
TRENCHING, BACKFILLING, AND LAYING AS PER DESIGN ALIGNMENT AND
LEVELS IF ANY, ETC INCLUDING, MATERIAL TEST REPORT FROM THE THIRD
PARTY CONTROL UNIT, AS PER THE SPECIFICATIONS AND DIRECTIONS OF
DEPARTMENTAL OFFICERS AT THE SITE. | 3,000 | cent | - | - |
| 3Providing Automation works | |||||
| 3.001 | OD50663/2025-2026:SURVEY, DESIGN, INSTALLATION AND TESTING OF FULLY AUTOMATED
COMMUNITY MICRO IRRIGATION SYSTEM WITH ELECTRONICALLY
CONTROLLED VALVES IN THE PROJECT AREA INCLUDING CONDUCTING
CONTOUR SURVEY, INDIVIDUAL FARM BOUNDARY SURVEY, PREPARATION OF
DESIGN AND DRAWINGS, PREPARATION OF OPERATION MANUAL,SUBMISSION
OF MATERIAL APPROVAL REQUEST, SUBMISSION OF WORK SCHEDULE,
FORMATION OF WATER USERS ASSOCIATION, TRAINING TO THE FARMERS,
SUITABLE PUMPS &BOOSTER PUMPS WITH STANDBY AND ACCESSORIES FOR
SUCTION AND DISCHARGE, CONSTRUCTION OF SUMP TANK OF SUITABLE SIZE
AND INCLUDING COST OF RELATED ALL ACCESSORIES SUCH AS PRIMARY
FILTRATION, SECONDARY FILTRATION,(SUITABLE AVAILABLE WATER SOURCE
CAN BE UTILIZED, THE FILTERS SHALL BE SUITABLE FOR GROUNDWATER OR
SURFACE WATER ACCORDING TO THE SITE CONDITION), FEEDERMAIN FROM
FILTERS, SOLENOID VALVES, PRESSURE RELEASE VALVES, PRESSURE GAUGES,
SAFETY ACCESSORIES, DRIP LOOP SYSTEM WITH PC EMITTERS OF MAXIMUM 3
LPH DISCHARGE HAVING EMITTER TO EMITTER SPACING OF MINIMUM 0.5 M (IN
LINE LATERALS SHOULD BE HIGH UV RESISTANT,WITH ANTI SIPHON MECHANISM, PRESSURE-COMPENSATED RANGE: 0.4 BAR ? 3.5 BAR, WIDE
FILTRATION AREA OF DRIPPER IN BETWEEN 30 MM2 TO 39MM2, SELF-FLUSHING
AND CONTINUOUS SELF-CLEANING MECHANISM, IDEAL FOR PERMANENT
CROPS IN COMPLEX TOPOGRAPHY AND SUB SURFACE APPLICATIONS,
RESISTANT TO STANDARD NUTRIENTS USED IN AGRICULTURE AND MEETS ISO
9261 STANDARDS), PRESSURE REGULATOR, DRIP MANIFOLD
ACCESSORIES,QUICK RELIEF VALVE,PRESSURE REGULATORS,NRV, MCU
SYSTEM WITH ALL OTHER ACCESSORIES(MCU SHOULD BE SCADA SCREEN WITH
REAL TIME STATUS OF OUTPUTS AND SENSORS READING, COLOR DISPLAY,
TOUCH SCREEN WITH RESOLUTION - 1280 * 800, CAPABLE OF WIRELESS
OPERATION, INBUILT GLOBAL SIM, OPTION OF INTERNET CONNECTION VIA
LOCAL SIM & LAN, MULTIPLE USERS ACCESS WITH HIERARCHY BASED ON
DIFFERENT ROLES, DOWNLOADABLE USER REPORTS - IRRIGATION AND
FERTIGATION REPORTS WITH CUSTOM TIME PERIOD, CREATE AND VIEW
IRRIGATION BLOCKS , CROP UNITS AND FARM VIEW WITH LIVE IRRIGATION
BLOCK STATUS, SATELLITE WEATHER INFORMATION BASED ON COORDINATES,
MULTI MAINLINE OPERATION (UP TO 4 MAINLINES), REMOTE ACCESS THROUGH
WEBVIEW AND MOBILE APP WITH PASSWORD PROTECTION, FLEXIBLE LOCAL 6
MODULES FOR OUTPUT, ANALOG INPUTS AND DIGITAL INPUTS CAPABILITY,
INBUILT 12 DIGITAL INPUT AND 6 DIGITAL OUTPUT AND COMMUNICATION
PORT, 256 OUTPUTS PER CONTROLLER WITH UPTO 102 LOCAL CONNECTIONS,
MONITOR IN-FIELD IRRIGATION STATUS BY SOIL MOISTURE SENSORS WITH
GRAPHICAL ANALYSIS AND WEATHER STATION, CAN BE OPERATABLE FROM
ANYWHERE WITH MULTI LOGIN ACCESS), RTU UNIT WITH SOLAR PANEL AND
ALL OTHER ACCESSORIES, SOIL TESTING AT THE FREQUENCY AS
REQUIRED,CONTRACTOR HAS TO DIPLOY EXPERIENCED AGRICULTURAL
ENGINEER, MACHINERY AND EQUIPMENT FOR EXECUTION, QUALITY CONTROL
ARRANGEMENTS, PREPARATION&SUBMISSION OF PRODUCTION PLAN &
OBTAINING CONSENT FROM FARMERS FOR LAYING PIPES AND ALLIED WORKS
IN THEIR PROPERTY WITH THE ASSISTANCE OF KIIDC STAFF, MARKET STUDY,
FORMING FARMERS ASSOCIATION AND ADVISING FARMERS ON CROP
SELECTION BASED ON WATER AVAILABILITY, MARKET STUDY,AND ALL
MATERIALS, FITTINGS, ADHESIVES SHALL BE AS PER THE SPECIFICATIONS AND
STANDARDS OF BIS/INTERNATIONAL CODES, INCLUDING OPERATION AND
MAINTENANCE FOR THREE YEARS AS MENTIONED IN THE TENDER
DOCUMENTS. | 3,000 | cent | - | - |
| 4APPENDIX 5 ELECTRICAL | |||||
| 4.001 | 1.12:Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 40 | metre | - | - |
| 4.002 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | 100 | metre | - | - |
| 4.003 | 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 100 | metre | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.87 MB
Tendernotice_2.pdf
PDF • 0.30 MB
Tendernotice_3.pdf
PDF • 0.33 MB
Tendernotice_4.pdf
PDF • 0.19 MB
Tendernotice_5.pdf
PDF • 0.45 MB
BOQ_1431012.xls
BOQ • 0.37 MB
3corrigendumtimeextention.pdf
PDF • 0.21 MB
corrigendumtimeextension2.pdf
PDF • 0.14 MB
corrigendumtimeextension1.pdf
PDF • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .