Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L1 | Accepted-AOC Admitted | |
| 2 | L2₹32.4 L+₹61,052.20 (1.92%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹32.4 L+₹61,492.70 (1.94%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹32.6 L+₹84,804.70 (2.67%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹33.8 L+₹2.1 L (6.54%)Rejected-AOC | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | VIJAYA ENTERPRISES L8 | G Srinivas Rao L12 | MSN ENGINEERING WORKS L1 | ESWAR ENTERPRISES L6 | SREE DURGA INFOTECH L7 | M/s.Raghava Enterprises L2 | Sri Jaya Surya Techs L5 | PNR CONSTRUCTIONS L11 | RAHITHI INFRA L10 | SONI ENGINEERS CONTRACTORS L4 | SRASHA MARINE SERVICES L3 | N.KRISHNA L9 | Y RAMESH L13 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| .01SCHEDULE 'A' PART-I: E/M WORKS | ||||||||||||||||
| 1.00 | Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including suitable size PVC conduit totally concealed/surface conduit in walls/ceiling with tee , bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for One light/fan point/bell point/5 Amp indepentent board controlled by one switch complete incl taking down the exisitng all as specified and as directed. Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cementing work to the disturbed and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour. | 180 | Point | 977 ₹1,75,860 | 1,080 ₹1,94,400 | 550 ₹99,000 | 796.5 ₹1,43,370 | 800 ₹1,44,000 | 405 ₹72,900 Lowest | 720 ₹1,29,600 | 1,062 ₹1,91,160 | 1,000 ₹1,80,000 | 650 ₹1,17,000 | 600 ₹1,08,000 | 1,058 ₹1,90,440 | 1,110 ₹1,99,800 |
| 2.00 | All as per item 1 above but for 5 Amps independant board complete all as specified and as directed | 35 | Point | 1,048 ₹36,680 | 1,162 ₹40,670 | 550 ₹19,250 | 858.75 ₹30,056.25 | 800 ₹28,000 | 405 ₹14,175 Lowest | 730 ₹25,550 | 1,145 ₹40,075 | 1,150 ₹40,250 | 620 ₹21,700 | 650 ₹22,750 | 1,135 ₹39,725 | 1,200 ₹42,000 |
| 3.00 | Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in exisiting PVC conduit (any size) totally concealed/surface conduit in walls/ceiling with tee , bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for One light/fan point/bell point/5 Amp indepentent board controlled by one switch complete all as specified and as directed. Note:-(i) The quoted rate shall includes dragging the old wires and providing the new copper wiring through exisitng conduits and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour. | 55 | Point | 492 ₹27,060 | 542 ₹29,810 | 450 ₹24,750 | 401.7 ₹22,093.5 | 850 ₹46,750 | 306 ₹16,830 Lowest | 390 ₹21,450 | 535.64 ₹29,460.2 | 550 ₹30,250 | 550 ₹30,250 | 600 ₹33,000 | 528 ₹29,040 | 567 ₹31,185 |
| 4.00 | Description all as per item No. 3 above but for 05Amp switch socket out let,on independent board complete all as specified | 30 | Point | 569 ₹17,070 | 630 ₹18,900 | 450 ₹13,500 | 464 ₹13,920 | 850 ₹25,500 | 306 ₹9,180 Lowest | 410 ₹12,300 | 618.72 ₹18,561.6 | 630 ₹18,900 | 580 ₹17,400 | 550 ₹16,500 | 615 ₹18,450 | 645 ₹19,350 |
| 5.00 | Description all as per item No.1 above but for 15/16Amp switch socket out let, independent with 4.0sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified | 25 | Point | 1,899.85 ₹47,496.25 | 2,075 ₹51,875 | 600 ₹15,000 Lowest | 1,548.75 ₹38,718.75 | 1,150 ₹28,750 | 630 ₹15,750 | 1,150 ₹28,750 | 2,065.1 ₹51,627.5 | 2,000 ₹50,000 | 700 ₹17,500 | 750 ₹18,750 | 2,061 ₹51,525 | 2,120 ₹53,000 |
| 6.00 | Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn surface stove enamel steel conduit (any size) on walls/ceiling with tee, bend, elbows,junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity suitable for flame proof switches, sockets regulator and connected the earth wire to common earth dolly for One light point/fan point controlled by one switch complete incl taking down the exisitng all as specified and as directed. Note:-(i) The quoted rate shall includes all the cost of making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour. | 25 | Point | 1,248 ₹31,200 | 1,370 ₹34,250 | 800 ₹20,000 | 1,017 ₹25,425 | 1,200 ₹30,000 | 405 ₹10,125 Lowest | 1,100 ₹27,500 | 1,356.22 ₹33,905.5 | 1,300 ₹32,500 | 600 ₹15,000 | 550 ₹13,750 | 1,353 ₹33,825 | 1,400 ₹35,000 |
| 7.00 | Description all as per item No. 5 above but for 15/16Amp flame proof switch socket out let, independent with4.0 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0Sqmm for earth continuity conductor, complete all as specified | 15 | Point | 2,311 ₹34,665 | 2,522 ₹37,830 | 900 ₹13,500 | 1,883.45 ₹28,251.75 | 1,500 ₹22,500 | 648 ₹9,720 | 1,350 ₹20,250 | 2,511.31 ₹37,669.65 | 2,500 ₹37,500 | 550 ₹8,250 Lowest | 600 ₹9,000 | 2,508 ₹37,620 | 2,560 ₹38,400 |
| 8.00 | Description all as per item No.7 above but in the existing conduit complete all as specified | 25 | Point | 1,102.5 ₹27,562.5 | 1,215 ₹30,375 | 840 ₹21,000 | 898.8 ₹22,470 | 1,400 ₹35,000 | 540 ₹13,500 | 850 ₹21,250 | 1,198.38 ₹29,959.5 | 1,100 ₹27,500 | 520 ₹13,000 | 499 ₹12,475 Lowest | 1,195 ₹29,875 | 1,240 ₹31,000 |
| 9.00 | M&L for removing under water lights by breaking the sealing compound/admix/ cement mix base, removing carefully the unsv fittings from the water RCC tank complete duly from the level vacated tank and replacing the defective, suitable cap LED Under water lights and refixing the new light fitting with the ceiling compund (any water proofing materail) to embedd the light to the RCC Tank complete all as specifed and as directed. (Note : Rates inclusive of necessary PCC work, Waterproofing compound/ mixture , requisite electrical connections ) (Lights will be measured and paid separately) | 5 | Each Job | 2,207 ₹11,035 | 2,431 ₹12,155 | 4,000 ₹20,000 | 1,800 ₹9,000 | 3,000 ₹15,000 | 1,800 ₹9,000 | 2,000 ₹10,000 | 2,450 ₹12,250 | 2,350 ₹11,750 | 500 ₹2,500 | 450 ₹2,250 Lowest | 2,445 ₹12,225 | 2,470 ₹12,350 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
28 Oct 2025, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
REPAIR MAINTENANCE OF INTERNAL WIRING SUBMAIN WIRING DBs EARTHING AND OTHER ACCESSORIES AT MO V OLD AND NEW INS VISWAKARMA BVY YARD NSB WED CTW AND DSRV ETC UNDER AGE E M OF GE ND VISAKHAPATNAM
2025_MES_734808_1
8530/GEND/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ND VISAKHAPATNAM
₹90,000
Yes
8 Jan 2026
11 Oct 2025
30 Oct 2025
11 Oct 2025
28 Oct 2025
21 Oct 2025
Amount
SCHEDULE 'A' PART-I: E/M WORKS
Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including suitable size PVC conduit totally concealed/surface conduit in walls/ceiling with tee , bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for One light/fan point/bell point/5 Amp indepentent board controlled by one switch complete incl taking down the exisitng all as specified and as directed. Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cementing work to the disturbed and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour.
All as per item 1 above but for 5 Amps independant board complete all as specified and as directed
Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in exisiting PVC conduit (any size) totally concealed/surface conduit in walls/ceiling with tee , bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for One light/fan point/bell point/5 Amp indepentent board controlled by one switch complete all as specified and as directed. Note:-(i) The quoted rate shall includes dragging the old wires and providing the new copper wiring through exisitng conduits and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour.
Description all as per item No. 3 above but for 05Amp switch socket out let,on independent board complete all as specified
Description all as per item No.1 above but for 15/16Amp switch socket out let, independent with 4.0sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified
Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn surface stove enamel steel conduit (any size) on walls/ceiling with tee, bend, elbows,junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity suitable for flame proof switches, sockets regulator and connected the earth wire to common earth dolly for One light point/fan point controlled by one switch complete incl taking down the exisitng all as specified and as directed. Note:-(i) The quoted rate shall includes all the cost of making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour.
Description all as per item No. 5 above but for 15/16Amp flame proof switch socket out let, independent with4.0 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0Sqmm for earth continuity conductor, complete all as specified
Description all as per item No.7 above but in the existing conduit complete all as specified
M&L for removing under water lights by breaking the sealing compound/admix/ cement mix base, removing carefully the unsv fittings from the water RCC tank complete duly from the level vacated tank and replacing the defective, suitable cap LED Under water lights and refixing the new light fitting with the ceiling compund (any water proofing materail) to embedd the light to the RCC Tank complete all as specifed and as directed. (Note : Rates inclusive of necessary PCC work, Waterproofing compound/ mixture , requisite electrical connections ) (Lights will be measured and paid separately)
Supply and fixing Surface under water LED light fittings 36 watts capacity with connected connector, epoxy joint and other connected accessories complete all as specified and as directed {Make Jaguar (WW DC IP68 : FLSUWL36WW0045DO)}
S & F in repairs Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge.
S & F in repairs Modular switch 1 way 16A, 1 module single pole complete all as specified and directed by Engr-in-charge.
S & F in repairs ceiling rose surface bake lite with 3 terminals complete all as specified and directed by Engr-in-charge.
S & F in repairs of modular Socket, 6A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified.
S & F in repairs of modular Socket 15A/16A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified.
S & F in repairs of modular Fan step regulator, 100W - 1 module complete all as specified.
S & F in repairs of modular Fan step regulator, 100W - 2 module complete all as specified.
S& F for modular modular white cover plate with frame 4 module complete all as specified and directed.
S& F for modular modular white cover plate with frame upto 4 to 8 module complete all as specified and directed.
S& F for modular modular metal/pvc flush box 4 module complete all as specified and directed
S& F for modular modular metal/pvc flush box upto 4 to 8 module complete all as specified and directed
S & F in repairs Switch flame proof switch socket and plug combined in LM6 cable termination box in LM6 ,16A 250 volt,2P+earth complete all as specified and directed.
S & F in repairs Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Supply and fix switch piano flush type,5 Amps 240 volts single pole one way.
S/F in repairs socket only 5 amps flush type.
S/F in repairs socket only 15 amps flush type.
S/F in repairs switch socket combination 2 in 1, 5 amps flush type.
S/F in repairs switch socket combination 15/16 amps, 5 in 1, flush type.
S/F in repairs switch socket combination 2 in 1, 5 amps box type.
S/F in repairs switch socket combination 15/16 amps, 5 in 1, box type.
S&F in repairs fan regulator electronic type, rotary step type , 240 Volt.
S&F in repair Bell push flush type, 5 Amps complete all as specified and directed
S&F in repair buzzer Ding dong, AC 230 volts single pole
S & F in repairs 4 feet long Hanging/Suspended type LED light fittings, retro bar professional WH 5700K to 6200K and minimum 4500 lumens (36-40 Watt) of cool white / warm, soft light and glare proof symmetrical illumination (with continuous mounting end cap) with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Light Batten Frame wall mounted with all accessories suitable for mounting 18W LED including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs LED Tube rod only complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Tube Light Batten Frame wall mounted with all accessories suitable for mounting 9/10W LED including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repairs of garden bollard light LED type 9 watt 230 watt volts AC outdoor type upto 3 feet height with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engineer- in -Charge.
Supply and fixing in repairs post top lantern LED type 25/36 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed
S & F in repairs square recessed mounted LED light (1'x1') of minimum (15 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Square surface mounted LED light (2'x2') of minimum (36 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Square recessed mounted LED light (2'x2') of minimum (36 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Square recessed mounted LED light (4'x1') of minimum (36 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Square recessed mounted LED light of round type for Ceiling cutout: Ø 160 mm, height 16 mm, (9- 12 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Square recessed mounted LED light of round type for Auditorium ceiling at a height of not less than 15 feet duly providing climbing arrangements with safety precautions in vouge by removing the old conventional type if recess fittings any cap and replacing with 22 watts /24 Watts warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge. (Note : Rates quoted are deemed to be incl of necessary arrangemnts to work at a ht of 15 Ft from the GL as directed by the Engr-in-charge)
Supply and fixing flame proof LED fitting 90 W , CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as directed by Engr-in-Charge.
S & F in repairs CMRI certified flame proof LED tube light fittings 40 watts with pressure die cast aluminium housing IP-65 protection heat resistance toughen glass cover, electronic driver all accessories internally prewired connecting with flexible copper conductor of size 1.5sqmm including taking down existing light fittings of any description all as specified and directed.
S & F in repairs CMRI certified flame proof LED flood light fittings 60 watts with pressure die cast aluminium housing IP-65 protection heat resistance toughen glass cover, electronic driver all accessories internally prewired connecting with flexible copper conductor of size 1.5sqmm including taking down existing light fittings of any description all as specified and directed.
S & F in repairs High bay LED flood light fittings of 150 Watts cap with pressure die cast aluminium housing IP-65 protection heat resistance toughen glass cover, electronic driver all accessories internally prewired connecting with flexible copper conductor of size 1.5sqmm including taking down existing light fittings of any description all as specified and directed.
S & F in repairs LED flood light fittings of 120Watts cap with pressure die cast aluminium housing IP-65 protection heat resistance toughen glass cover, electronic driver all accessories internally prewired connecting with flexible copper conductor of size 1.5sqmm including taking down existing light fittings of any description all as specified and directed.
(Note for sl item Nos 46,49 & 50) the work to be carried out at a ht of 15-20 mtrs and rates quoted to be incl of hiring of heavy duty manupulator suitable for the mentioned ht and ensuring safety of the workers working at that ht. The workers should be covered with suitable inusrancy policy by the tenderer and this will deptt will not be liable for any accident while repairing/ replacing the hightbay/ flood lights and rates quoted are deemed to inclu of all the rates to work of specific hts)
S & F in repairs Building Security light LED type of minimum 35Watts Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair Aviation obstruction light LED type filament-less bulb complete including standard fixing arrangements including timer switch complete all as specified and as directed.
S & F in repairs Light Batten Frame wall mounted with all accessories suitable for mounting 20Watts LED including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs LED bulb 7/9 watts with holder pin/thread type complete all as specified and as directed by the Engineer-in-Charge.
S & F MCCB Enclosure Box suitable for 63 to 250 Amps outdoor type, IP 65 rating including all accessories for connecting MCCB and Cables complete all as specified by Engr-in-Charge.
S & F in repairs MCCB 4 Pole, 63 Amps, 50 Hz, 16KA, 415 Volts with all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 100 Amps, 50 Hz, 16KA, 415 Volts with all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 125 Amps, 50 Hz, 25KA, 415 Volts,adjustable thermal and fixed magnetic type with all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 160 Amps, 50 Hz, 25KA, 415 Volts, adjustable thermal and fixed magnetic typewith all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 200/250 Amps, 50 Hz, 36KA, 415 Volts, adjustable thermal and fixed magnetic typewith all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 400 Amps, 50 Hz, 36KA, 415 Volts, adjustable thermal and fixed magnetic typewith all necessary aluminium lugs and glands, etc complete all as directed
Supply and fixing in replacement of Factory made sheet metal enclosure for VTPN MCCB DBs double door (Fixed flush to the wall), with provision of MCCB as incommer & outgoing as TPN 415 volt, 8 Way, with suitable rated bus bar suitable for having MCB’s , complete all as specified (Note : MCCB/MCBs will be measured and paid separately under relavent items )
Supply and fixing in replacement of Factory made sheet metal enclosure for VTPN MCCB DBs double door (Fixed flush to the wall), with provision of MCCB as incommer & outgoing as TPN 415 volt, 4 Way, Isuitable rated bus bar and suitable for having MCB’s , complete all as specified. (Note : MCCB/MCBs will be measured and paid separately under relavent items )
Supply and fixing in replacement of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified. (Note : MCBs will be measured and paid separately under relavent items )
Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 8 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified. (Note : MCBs will be measured and paid separately under relavent items )
Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 4 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified. (Note : MCBs will be measured and paid separately under relavent items )
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified
Supply and fixing of MCB 40-100 Amp, 415 Volt, TPN, breaking capacity 10 KA 'C' series, , complete all as specified
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, , complete all as specified
Supply and fixing of MCB 63 Amp, 415 Volt, TP, breaking capacity 10 KA 'C' series, , complete all as specified
M&L for sub main wiring with four run of 10.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 10.0 Sq mm drawn through PVC concealed/surface conduict of 40 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 05 run along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L for sub main wiring with two run of 10.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 10.0 Sq mm drawn through PVC concealed/surface conduict of 40 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 03 run along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L for sub main wiring with two run of 6.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 6.0Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L for sub main wiring with two run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L for sub main wiring with two run of 2.5 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 2.5 Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
Supply lay and testing of cable in trenches/walls/ floor XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 25sqmm 4.0 core complete all as specified and directed by Engr-in-charge.
Supply lay and testing of cable in trenches/walls/floor XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 10sqmm 4.0 core complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified
Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Material and labour for natural river sand as cushioning of cables, including spreading and punning down complete all as specified and directed by Engineer in charge. Note : punned thickness shall be measured for payment purpose
Supply and laying in trenches Bricks common burnt clay building bricks, sub-class ‘B’ designation 75 laid perpendiculat to the trench for cable protection complete all as specified and as directed
Material and labour for 50 mm dia GI steel tubes 'light grade' for cable protection including sealing both ends complete all as specified and as directed by Engineer-in-charge.
Material and labour for cutting existing road/PCC/drain for laying of underground cable and including necessary earth work and making good to match with the exisitng surface with PCC1:3:6 type CI using 20mm graded aggregates complete all as specified and as directed.
M&L for replacement of DOL Startor suitable for hanger / rolling shutter two way revolving type motors upto 3.0 HP cap (clockwise and anticlockwise both type) complete all as specified and directed
S & F in repairs Wall mounted AC plug and socket distribution box (Industrial socket) including plug connector 16 Amps, 2 pole and earth, IP 40 protection of metal body single phase 240 Volts, 50 Hz with provision for one 16 Amps MCB 2P including necessary fixing arrangements complete all as directed by the Engineer-in-Charge.
S & F in repairs Wall mounted AC plug and socket distribution box (Industrial socket) including plug connector of 32 Amps, 3 pole, neutral and earth, IP 44 protection of metal body three phase 415 Volts, 50 Hz with provision for one 32 Amps MCB TPN including necessary fixing arrangements complete all as directed by the Engineer-in-Charge.
S & F in repairs moduler sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete suitable for AC all as specified and directed.
Supply and laying of synthetic insulation rubber mat of size 1MX2MX2mm thickness of voltage upto 3.3KV power supply, insulation category of class A for indoor LT panel for electric shock safety complete all as specified
Labour only for cleaning , tightening nuts &screw and all associated works for DB & LT panel complete
Labour only for refixing disoriented pvc surface wiring , light fitting and all associated works complete. Note: Dilapidated conduit / casing cappingshall be measured and paid seperately of this schedule
Supply only pvc conduit upto 25 mm.
Supply only pvc casing capping 25 mm.
Supply and replacement of LED driver suitable for LED Light fittings of upto 36-75 watt LED light of any type complete all as specified
Supply and replacement of LED driver suitable for LED Light fittings of upto 75-100 watt LED light of any type complete all as specified
Supply and replacement of LED driver suitable for LED Light fittings of upto 100-150 watt LED light of any type complete all as specified
M&L Earthing complete with copper plate electrode 600x600x3mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with copper earth strip of 20X3 mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 5, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & ,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh, 40mm dia light grade GI pipe for protection of strip complete all as specified and testing on completion.
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI earth strip of 25X4 mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh, 40mm dia light grade GI pipe for protection of strip complete all as specified and testing on completion.
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh, 20mm dia light grade GI pipe for protection of strip complete all as specified and testing on completion.
M&L for 20X3 mm copper strip for earthing connection to building, complete all as specified.
M&L for 25x4mm galvanised iron strip for earthing connection to building, complete all as specified.
Dismantling earthpit chamber manually without disturbing the earth continutiy strp/wire, funnel, water pipe carefully and placing with new PCC earth pit chamber made of PCC 1:3:6 type C1 chamber (450mm 450mmx 300mm depth)& ,CI frame with CI 10mm thick cover alongwith new wire mesh water funnel complete all as specified and as directed
M&L for 4mm galvanised iron earth wire for earthing connection to building, complete all as specified.
Note :- (a) The rate quoted by the tenderer for item ser no 1 to 103 here in before shall deemed to be inclusive for the following provisions in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this account:- (i) The contractor on getting information through SMS/E-mail regarding the nature of repair to be carried out he shall immediately respond the same and make all out efforts to carry out the same on priority within 24 hours. In case of any delay in responding/ attending the repairs within 48 hours, the GE may at his absolute discretion impose penalty on the contractor at Rs 100/- per day per each work upto 05 (Five) days and Rs 200/- per day there after till completion of the work. Incase of delay without valid reasons as decided by GE.
(ii) Further, the above penalty is applicable even for the multiple works at multiple locations of work at the same period. It is responsiblity of contractor to make suitable arrangement for attending the repairs simultaneously at all the places.(iii) The decision of the GE as to weather of particular repair has been attended or not on a particular day will be final and binding. The above penality shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e. (Compensation for delay in completion of work).(b) Tenderers/ Bidders are advised to visit the site and quote the rate accordingly.
M/s.Raghava Enterprises (BID ID -3461440)
SRASHA MARINE SERVICES (BID ID -3461077)
SONI ENGINEERS CONTRACTORS (BID ID -3461516)
Sri Jaya Surya Techs (BID ID -3461637)
ESWAR ENTERPRISES (BID ID -3461145)
SREE DURGA INFOTECH (BID ID -3461393)
VIJAYA ENTERPRISES (BID ID -3460098)
N.KRISHNA (BID ID -3460076)
RAHITHI INFRA (BID ID -3460909)
PNR CONSTRUCTIONS (BID ID -3459859)
G Srinivas Rao (BID ID -3460187)
Y RAMESH (BID ID -3459097)
stage.html
html • 0.08 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_822799.xls
BOQ • 0.40 MB
Tender8530.pdf
Tender Documents • 1.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .