Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC H NO 765 VPO BIHTA TEHSIL BARARA DISTRICT AMBALA 133101 | AMBALA | AMBALA | HARYANA | 133101 | L1 | Accepted-AOC AOC | |
| 2 | L2₹1.1 Cr+₹1.1 Cr (4432.8%)Rejected-Finance AGGARSAIN CHOWK VILLAGE BHOJPUR POST OFFICE FETEHPUR SAHARANPUR ROAD YAMUNANAGAR HARYANA 135101 | YAMUNANAGAR | HARYANA | 135101 | L2 | Rejected-Finance Highest | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected |
Tender Value
₹2.4 L
EMD Value
₹4,840
Closing Date
19 May 2022, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Const. of Sub Health Centre at village Shahpur in Ambala District (Pdg. E.I work).
2022_HRY_221133_1
PWD/Elect-KNL/Elect-AMB/110260
Open Tender
Construction Works
Works
120 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹4,840
Yes
15 Jun 2022
13 May 2022
20 May 2022
13 May 2022
19 May 2022
13 May 2022
Amount
1.5 Sq. Mm ISI marked, FRLS PVC insulated single core copper conductor cable. EL003
2.5 Sq. Mm ISI marked, FRLS PVC insulated single core copper conductor cable. EL004
4.0 Sq. Mm ISI marked, FRLS PVC insulated single core copper conductor cable. EL005
Supply, erection, testing of ceiling Fan IS marked (as per IS Code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer in charge. 48" (1200mm). HSR No. 20.71.1
COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B HSR No. 23.2.1.2
Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B HSR No. 23.2.4.2
Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLs copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B HSR No. 23.2.5.2
Supply, erection, testing of Exhaust Fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer in Charge. HSR No. 20.72
Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia. HSR No. 23.6.6.1
MS pipe of 25 mm dia. HSR No. 23.6.6.2
Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. HSR No. 23.7.6.2
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Double pole MCCB 16 to 63 Amp HSR No. 23.22.1.1
MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP HSR No. 23.22.2.1
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) HSR No. 23.22.4.5
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole HSR No. 23.22.5.1
EARTHING AND LIGHTENING ARRESTOR Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. HSR No. 24.1.1
Extra for using salt and char coal/coke for pipe earth electrode as required. HSR No. 24.1.2
Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop carthing as required. HSR No. 24.1.13
Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. HSR No. 24.1.11
Supply and erection of 32mm dia metre 1.5 m long bracket (B-class) making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing of GI. bracket on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections. HSR No. 24.4.3
S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Mtr below ground level including diging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia HSR No. 24.5.2.3
Supply of 10 Sq. mm 2 Core Cable Armoured underground cable ,loose in existing pipe or trenches, make as per approved list complete with necessary connections complete in all respect including all material required to complete the job in all respect & up to the entire satisfaction of the Engineer in charge of the work . NS-1
Supply of 16 Sq. mm 4 Core Cable Armoured underground cable ,loose in existing pipe or trenches, make as per approved list complete with necessary connections complete in all respect including all material required to complete the job in all respect & up to the entire satisfaction of the Engineer in charge of the work. NS-2
Supply and erection of SMC Junction box GSJB2520-(250x200x100) material required to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work. Make Sintex. NS-3
Supply of LED Batten 18/20 Watt. with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work. Make Bajaj/Halonix/Philips/Crompton/ Havells. NS-4
Supply of LED Batten 40 Watt. with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work. Make Bajaj/Halonix/Philips/Crompton/ Havells. NS-5
Supply and erection of 72 watts LED street light with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work (Make:Bajaj/GE Wipro/ Surya/ Polycab. NS-6
Radhey Krishan Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .