Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 58 667 SAPTHATHI BUILDING KONTHURUTHY THEVARA ERNAKULAM KERALA 682013 | ERNAKULAM | KERALA | 682013 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
17 Feb 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGM P and P
ASSISTANT GENERAL MANAGER PROJECTS AND PLANNING PD ADMINISTRATION
RENOVATION OF SUITE LOTUS AND KITCHEN IN UDYOGAMANDAL HOUSE
2025_FACT_844970_1
3017/2024-2025/E30781
Open Tender
Miscellaneous Works
Item Rate
365 days
Udyogamandal
ATTACHED IN TERMS AND CONDITIONS
6 documents required · 6 mandatory
₹0
₹5,000
Yes
18 Feb 2025
20 Jan 2025
18 Feb 2025
20 Jan 2025
17 Feb 2025
20 Jan 2025
RENOVATION OF SUITE LOTUS & KITCHEN IN UDYOGAMANDAL HOUSE
Supply, Erection, Termination and connection of the 6 way, 3ph, 415 V Horizontal double door MCB Lighting DB Having 100A, 30 mA 4 pole RCCB, 100 A 4 pole Isolator as incomer, 10 no's of 16A SP MCBs for each Power circuit and 5 No's of 10 A SP MCBs for Providing Supply for sub-circuit. LDB shall be mounted properly concealed on the wall by the contractor. Incomer for this DB should Drawn through pipe size not less than 20mm from Main Loads Center by suitable metal saddles spacing not less than 50 cm. 6 sq mm Phase and Neutral Wire and 4 Sq mm for Earth. All Required items for this Work Shall Be in the scope of the Contractor (Including the cementing and finishing of the wall after fixing of the DB) APPROVED MAKE FOR DB AND MCBs:-LEGRAND / HONEYWELL/L&T/SCHNEIDER
Supply, Erection, Termination and connection of the 6 way, 3ph, 415 V Horizontal double door MCB Lighting DB Having 100A,30 mA 4 pole RCCB, 100 A, 4 pole Isolator as incomer, 11 no's of 16A SP MCBs for each Power circuit and 7 no's of 10 A SP MCBs for Providing Supply for sub-circuit. DB shall be mounted in suitable frame fabricated by suitable MS angle frame (25 x 25 x 6), epoxy painted (primer + 2 coats) and properly fixed on wall by the contractor. All Required structural items, DB with 4P RCCB, 4P MCBs, MCBs, flexible glands, suitable pvc pipes, etc shall be in the scope of the contractor. Existing in-put armoured cable can be used for main supply from Load Center. If incomer cable length is not adequate for termination in DB Cable should be jointed with copper/aluminum flexible cable of size similer to incomer cable by proper lug/ferrules by providing suitable joint box near DB, This also be in the scope of the contractor. APPROVED MAKE FOR DB , RCCBs AND MCBs:-LEGRAND / HONEYWELL/L&T/SCHNEIDER
Supply of 6A Modular Switches as spares for The work specified in Schedule No 3 (Beand and type of switches should be exactly same as the switches used for the work specified in Schedule No-3)
Supply of 6A Modular Sockets as spares for The work specified in Schedule No 3 (Beand and type of sockets should be exactly same as the sockets used for the work specified in Schedule No-3)
Supply of Modular step type regulators as spares for The work specified in Schedule No 3 (Beand and type of Regulators should be exactly same as the Regulators used for the work specified in Schedule No-3)
Concealed pipe Point wiring with individual control For 16 A power sockets and 16 A DP switchs for ACs, using flexible copper cables 2.5 sqmm for control and neutral connection through pvc conduits not less than 20 mm using metal saddles with spacing not exceed 50 cm as per relevant drawings or instructions from FACT Engineer in Charge. The work shall include wiring along roof/beam/column/ceiling using clamps and drawing wires as required. Preparation and fixing of modular switch boards, switches, cover plates, dummy plates, Etc. Drawing of 1.5 sq mm earth wires of flexible copper wire of green color for body earthing of metal clad items, connecting, testing and commissioning. For a point wiring, pipe length greater than 10 metres shall be considered as one and a half point. All the materials for this work shall be in the scope of the contractor. If additional power sockets are required in same switch boards that shall be considered as half point. (Including the cementing and finishing of the wall after fixing of the Switch Box and Piping) APPROVED MAKE : WIRE : POLYCAB/ RR KABEL/ KEI/ FINOLEX OF FR TYPE SWITCH, SOCKETS, ETC : LEGRAND- MYRIUS/ HONEYWELL-HORIZON/SCHNEIDER-UNICA PURE/L&T-ENTICE PIPE SHALL BE OF MEDIUM ISI MARKED
Supply of 16A Modular Switches as spares for The work specified in Schedule No 7 (Beand and type of Switches should be exactly same as the sockets used for the work specified in Schedule No-7)
Supply of Modular Sockets 16A as spares for The work specified in Schedule No 7 (Beand and type of sockets should be exactly same as the sockets used for the work specified in Schedule No-7)
Supply of Modular Switch dummy cover plates for The work specified in Schedule No 3 & 7 (Beand and type of switch dummy cover plate should be exactly same as used for the work specified in Schedule No-3 & 7)
Supply and Installation of of 20 W LED tube fittings with required clamps/fastners, All materials such as LED Fittings, clamps and fastners required for this work are in the scope of the contractor. APPROVED MAKE :- LUKER/HAVELLS/PHILIPS/DEWTON
Supply and Installation of Calling Bells with required clamps/fastners etc, All materials such as ,Calling Bell of Reputed Make, clamps and fastners required for this work are in the scope of the contractor
Supply and installation of ceiling fans (1200 mm). Supply of all materials required for the work shall be under the scope of the contractor. The specifications of the ceiling fan is such that its service value shoould be higher than 5.5 CMM/Watts. (Refer BEE Guide Line For service value and Star Ratings). APPROVED MAKE :- LUKER/CROMPTON/ USHA/ ORIENT.
Supply and installation of wall fans (600 mm). Supply of all materials required for the work shall be under the scope of the contractor. The specifications of the wall fan is such that its service value shoould be higher than 5.5 CMM/Watts. (Refer BEE Guide Line For service value and Star Ratings). APPROVED MAKE :- LUKER/CROMPTON/ USHA/ ORIENT.
Supply and installation of Angle Batten Holders For Rooms, Bathrooms, Stores and Work area. All materials required for the work including the Angle Batten shall be supplied by the contractor.
Supply and Installation of 2MD 3W LED Foot lamp with required metal box, cover plate, etc. All materials such as LED Fittings, metal box, cover plate, clamps and fastners required for this work are in the scope of the contractor. APPROVED MAKE :- LEGRAND- MYRIUS /HAVELS-CORAL/SCHNEIDER-UNICA PURE/L&T-ENTICE
Supply of 2MD 3W LED foot lamp Fittings as spares for The work specified in Schedule No 17 (Brand and type of 2MD 3W LED foot lamps should be exactly same as the 2MD 3W LED foot lamp fittings used for the work specified in schedule No-17)
Supply and Installation of of 8W LED ceiling Light with required clamps/fastners, All materials such as LED Fittings, clamps and fastners required for this work are in the scope of the contractor. APPROVED MAKE :- LUKER/HAVELLS/PHILIPS/CROMPTON
Supply of 8W LED ceiling Light Fittings as spares for The work specified in Schedule No 19 (Brand and type of 8W LED ceiling Light should be exactly same as the 8W LED ceiling Light fittings used for the work specified in schedule No-19)
Supply and Installation of of 12W LED ceiling Light with required clamps/fastners, All materials such as LED Fittings, clamps and fastners required for this work are in the scope of the contractor. APPROVED MAKE :- LUKER/HAVELLS/PHILIPS/CROMPTON
Supply of 12W LED ceiling Light Fittings as spares for The work specified in Schedule No 21 (Brand and type of 12W LED ceiling Light should be exactly same as the 12W LED ceiling Light fittings used for the work specified in schedule No-21)
Supply and Installation of of 36W LED ceiling Light with required clamps/fastners. All materials such as LED Fittings, clamps and fastners required for this work are in the scope of the contractor. APPROVED MAKE :- LUKER/HAVELLS/PHILIPS/CROMPTON
Supply of 36W LED ceiling Light as spares for The work specified in Schedule No 23 (Brand and type of 36W LED ceiling Light should be exactly same as the 36W LED ceiling Light fittings used for the work specified in schedule No-23)
Supply and Installation of 12W LED Surface mount ceiling Light with required clamps/fastners, All materials such as LED Fittings, clamps and fastners required for this work are in the scope of the contractor. APPROVED MAKE :- LUKER/HAVELLS/PHILIPS/CROMPTON
Supply of 12W LED Surface mount ceiling Light Fittings as spares for The work specified in Schedule No 25 (Brand and type of 12W LED Surface mount ceiling Light should be exactly same as the 12W LED Surface mount ceiling Light fittings used for the work specified in schedule No-25)
Supply and Installation of 9W LED Fancy mirror Lamp with required clamps/fastners, All materials such as LED Fittings, clamps and fastners required for this work are in the scope of the contractor. APPROVED MAKE :- LUKER/HAVELLS/PHILIPS/CROMPTON
Supply and Installation of LED profile light with required profile channel, clamps/ fastners, All materials such as LED Strip (minimum 120/M), profile channel, suitable LED drive, Fittings, clamps and fastners required for this work are in the scope of the contractor, APPROVED MAKE :- LUKER/HAVELLS/PHILIPS/CROMPTON
Supply and Installation of LED strip light with required clamps/ fastners, All materials such as LED Strip (minimum 60/M), suitable LED drive, Fittings, clamps and fastners required for this work are in the scope of the contractor, APPROVED MAKE :- LUKER/HAVELLS/PHILIPS/CROMPTON
Erection of earth electrodes, earth cable laying 2 runs of 1 x 16 sqmm Aluminium PVC cable, from earthing pit to corresponding 3 phase DB, clamping, connection and commissioning of maintenance free copper bonded earthling systems of DB -at suitable locations . Installation of earthing system as per the specified condition mentioned above and supply of All required materials for this work such as maintenance free copper bonded earthing system approved by Kerala State Electrical Inspectorate, compressing of 3 m long, dia not less than 17 mm earth electrode of low carbon steel with 250 micron copper bonding on outer surface with associated items like environment friendly carbon based back fill compound, hardware, clamps, binding wires, connection lugs, anticorrosive paint, bituman, Sand, cement, Bricks and required length of 1 x 16 sqmm flexible Al PVC cable etc. as required for this work shall be in the scope of the contractor. (Double earth should be provided for 3 phase DB)
Rerouting of Power Cables up to 4*50 Sqmm from Existing 3 phase DB to New DB Location as specified by FACT Engineer -in -Charge
Excavation of New cable trenches of size 300 mm * 300 mm in ordinary soils for laying cables , refilling the trench and consolidating.
V V ELECTRICALS (BID ID -3172596)
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .