| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC | L1 | Accepted-AOC As being L1 and qualifies eligibility criteria | |
| 2 | L2₹3.4 L+₹1.0 L (44.9%)Rejected-Finance 161 GROUND FLOOR SHRI SAI ELECTRICALS VITTHAL RUKHMINI TEMPLE ROAD WARD NO 02 AT NANDORI TA SAONER NAGPUR MAHARASHTRA 441112 | NAGPUR | MAHARASHTRA | 441112 | L2 | Rejected-Finance As L2 | |
| 3 | L3₹4.9 L+₹2.6 L (110.2%)Rejected-Finance | L3 | Rejected-Finance As L3 | |
| 4 | Rejected-Technical WARD NO 11 NEAR CENTRAL SCHOOL MOUHARPARA MANENDRAGARH DIST MCB C G 497442 | MANENDRAGARH | MCB | C G | 497442 | - | Rejected-Technical Does not qualify eligibility criteria |
Tender Value
₹5.8 L
EMD Value
₹7,300
Closing Date
27 Jan 2025, 5:00 pmClosed
Staff Officer (EnM), Chirimiri Area
Office of the General Manager, SECL Chirimiri Area , P.O. West Chirimiri, Distt. MCB (C.G.) 497773
Repairing/Rewinding of 03 Nos. Power Transformers, 1600 KVA, 1250 KVA and 1000 KVA, 33kV/3.3kV of Kurasia Group.
2025_SECL_326019_1
SECL/GM/CHRM/EM/e-Tender/ 24-25/45 dtd. 16.01.2025
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
RWS Korea, Chirimiri Area
As per NIT
4 documents required · 4 mandatory
₹7,300
14 May 2025
17 Jan 2025
28 Jan 2025
17 Jan 2025
27 Jan 2025
17 Jan 2025
17 Jan 2025 - 24 Jan 2025
Amount
For Transformer 1000 KVA , 33kV/3.3kV , Sl. No. 30180 V , Make - Crompton Greaves
99.96% electrolyte copper conductor for primary coil (14 SWG TPC)
Re-insulation & recoiling of damaged secondary winding
Other Insulation material cost @15% of above {1.1 + 1.2}
Labour Charges @10% of above {1.1+1.2+1.3}
Less Scrap Material (-) (to be subtracted)
Testing and Supervision Charges @10% of {1.1 to 1.5}
For Transformer 1600 KVA , 33kV/3.3kV , Sl. No. 24196 , Make - Marsons Electricals Pvt. Ltd.
99.96% electrolyte copper conductor for primary coil (11 SWG TPC)
Re-insulation & recoiling of damaged secondary winding
Other Insulation material cost @15% of above {2.1 + 2.2}
Labour Charges @10% of above {2.1+2.2+2.3}
Less Scrap Material (-) (to be subtracted)
Testing and Supervision Charges @10% of {2.1 to 2.5}
For Transformer 1250 KVA , 33kV/3.3kV , Sl. No. 12134 , Make - ETE Thana Electric Supply Co. Ltd.
99.96% electrolyte copper conductor for primary coil (11 SWG TPC)
Re-insulation & recoiling of damaged secondary winding
Other Insulation material cost @15% of above {3.1 + 3.2}
Labour Charges @10% of above {3.1+3.2+3.3}
Less Scrap Material (-) (to be subtracted)
Testing and Supervision Charges @10% of {3.1 to 3.5}
Total impact of GST for the purpose of CTC
SHREE SAI ELECTRICALS (BID ID -1120987)
SAMEER ELECTRICAL (BID ID -1121221)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .