Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L1 | Accepted-AOC Admitted | |
| 2 | L2₹31.5 L+₹2.4 L (8.28%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹36.0 L+₹6.9 L (23.9%)Rejected-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L3 | Rejected-AOC Rejected | |
| 4 | Rejected-Technical HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | - | Rejected-Technical Not Meeting the eligibility criteria |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Sept 2024, 6:00 pmClosed
GE (AF) No 02 Jodhpur
GE(AF) No. 2 Jodhpur, AFS Jodhpur
Repair/maint of water supply installatons and allied GI/CI pipeline work under AGE E/M, GE (AF) No. 2 Jodhpur and Repair/rewiring/rewinding of pump electric motors and allied E/M work to water supply installations under AOR of AGE E/M, GE (AF) No. 2
2024_MES_667044_1
8470/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) No 02 Jodhpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) No 02 Jodhpur
₹80,000
Yes
4 Nov 2024
20 Jul 2024
16 Sept 2024
20 Jul 2024
13 Sept 2024
5 Aug 2024
27 Jul 2024 - 3 Aug 2024
Amount
Supply and fixing MCCB in replacement of 100 Amps, 3 pole, 415 volts, 50 HZ, rupturing capacity 16KA, connection with proper size of thimbles complete including taking out defective/ unserviceable MCCB all as specified and directed.
Supply and fix MCCB in replacement with thermal magnetic release adustable type DU 160, 160A, 36KA, 415 Volts 3 pole all as specified & directed.
Supply and fix MCCB in replacement with thermal magnetic release adustable type DN2-250D, 250A, 415 Volts 4 pole 36KA all as specified & directed.
Supply and fix MCCB in replacement with thermal magnetic release adustable type DN3-400D, 400A, 415 Volts 4 pole 36KA all as specified & directed.
Supply and fix MCCB in replacement with thermal magnetic release adustable type DN3-630D, 630A, 415 Volts 4 pole 50 KA all as specified & directed.
S&F in repair soft starter, suitable for 15 HP pumpset ,3 phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in repair soft starter, suitable for 50 HP pumpset ,3 phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in replacement 80mm dia butterfly valve complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 8.00 here-in-before but 100 mm dia bore.
All as per Srl item No 8.00 here-in-before but 150 mm dia bore.
All as per Srl item No 8.00 here-in-before but 200 mm dia bore.
All as per Srl item No 8.00 here-in-before but 250 mm dia bore.
Material and labour in repair for earthing complete with copper plate electrode 60cmx60cmx3.15mm thick, buried directly in ground, vertically to a dpeth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not lss than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead copper strip 20 x 3 mm by means of bolts, nuts, check-nuts and wahsers of galvanised iron and thimbles and of earth wire protected by galvanised iron pipe light grade 40mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh complete 1:3:6 type C-1 using 20mm graded stone aggregate in lieu of CI cover and frame etc all as specified and directed.
Supply & fixing as in repair cast iron sluice valve Long body of 80 mm bore, ISI marked with IS 14846 – 2000 with flanged ends and drilled, stainless steel spindle, CI gate with brass ring and iron wheel handle, cast iron cap, complete with neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, complete including testing all as specified.
All as per item No. 14 here-in-before but size of 100mm
All as per item No. 14 here-in-before but size of 150mm
All as per item No. 14 here-in-before but size of 200mm
All as per item No. 14 here-in-before but size of 250mm
S&F and testing in replacement of energy efficient LED street light fitting of 90 watt pole mounting comprising a diecast aluminium houing with heat resistant toughened glass with frame IP 66 protection complete all as specified and as directed.
S&F and testing in replacement of energy efficient LED street light fitting of 120 watt pole mounting comprising a diecast aluminium houing with heat resistant toughened glass with frame IP 66 protection complete all as specified and as directed.
S&F and testing of energy efficient LED Flood light fitting of 200 watt pole mounting comprising a diecast aluminium houing with heat resistant toughened glass with frame IP 66 protection of complete all as specified and directed .
S & F in repair GI Bracket for mounting street light fittings made out of light grade 32mm GI pipe and have angle of 120 degree incl fixing arrangement complete all as specified and as directed by engr-in-charge.
Supply and fix single core PVC insulated FR cable with multi stranded copper conductor 1.5 sq mm cross sectional area 3 core ,1100 volts grade including PVC conduit pipe all as specified and as directed.
Supply and fixing in replacement LED Solar street light fitting 36 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete.
Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 15cm deep including sweeping removing the same to distance not exceeding 50m away from the installation and burning the same all as specified and directed by Engr-in-Charge.
Supply & fixing as in repair cast iron body Foot valve of size 80mm bore ISI marked with IS 4038 with flanged ends and drilled, with neoprene rubber gasket joint and nuts bolts (high tensile) washers etc complete including testing all as specified.
All as per item No. 26.00 here-in-before but size of 100mm
All as per item No. 26.00 here-in-before but size of 150mm
S&F Cast iron non return valve / reflux valve with rubber seat flanged type with by pass arrangement suitable for 80mm bore pipe, ISI marked, conforming to IS- 5312/2004 with stainless steel spindle, CI gate with brass nuts, bolts, washers and jointing with necessary ruber gasket etc complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 29.00 here-in-before but 100 mm dia bore.
All as per Srl item No 29.00 here-in-before but 150 mm dia bore.
S&F in replcement FRP junction box for street light central with linked door control incl 6 amp MCB SP with aluminium bus bar-04 nos for controling street light/garden light complete as directed by Engr-in-Charge.
M&L for Construction of brick masonry valve pit, in repair, of internal size 60cm x 60cm x 60cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock , complete all as specified and directed by Engineer - in - Charge Note :- (i) Brick wall shall be 23 cm thick built in cement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds. (iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Three coats of white wash to internal surfaces of valve pit. (vi) Depth of valve pit shall be reckoned from the top of PCC in foundation.
All as per Srl item No 34.00 here-in-before but internal size 90cm x 90cm x 90cm
All as per Srl item No 34.00 here-in-before but internal size 150cm x 150cm x 90cm
M & L for repairing the rolling shutter of EM installations including main replacement of rolling GI pipe upto 50 mm dia and painting of shutter and minor parts like spring,nut bolts complete all as specified and as directed.
M & L for writing letters or figures (block,roman,) n exc 30 cm height including scrubbing/cleaning the floor /wall as per requirment /dimensions and double coat of a base paint complete all as specified and as directed.
M&L for preparation of old painted steel surfaces of panel body of any size incl scrapping old paint, denting and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for complete removal of existing paint of Elect motor with pump including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for complete removal of existing paint of pipeline of dia 80mm to 150mm, including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for complete removal of existing paint of pipeline / header of dia 200mm to 550mm, including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
Supply and fix in repair flanged GI pipe medium grade 80mm bore (as suction line of pump) including cutting threading welding of flange etc with GI fitting such as bend, flange, reducers etc including taking out old existing suction line.
Supply and fix in repair flanged GI pipe medium grade 100mm bore (as suction line of pump) including cutting threading welding of flange etc with GI fitting such as bend, flange, reducers etc including taking out old existing suction line.
Supply and fix in repair flanged GI pipe medium grade 150mm bore (as suction line of pump) including cutting threading welding of flange etc with GI fitting such as bend, flange, reducers etc including taking out old existing suction line.
S&F in repair soft starter, suitable for 75 HP pumpset ,3 phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
M&L for taking out of Elect Motor 50 HP Capacity installed as motor from foundation after disconnecting electrical connections, dismantling motor and rewiding the same with super enamelled copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts, reassembling and fixing the same in its original position including replacement of unserviceable nut-bolts, washer, lugs, terminal plate and making proper electrical connection complete all as specified and directed by Engineer-in-charge. Make of winding wire : - Devidayal / Chetak or equivelnent make. Note : - (i) Bearing if required for replacement shall be paid seprately (ii) Transportation of motor is included in the unit rate of items nothing extra shall be paid on this account
All as per serial item No. 47.00 here-in-before but motor of capacity 20 HP
All as per serial item No. 47.00 here-in-before but motor of capacity 15 HP
All as per serial item No. 47.00 here-in-before but motor of capacity 10/12.5 HP
All as per serial item No. 47.00 here-in-before but motor of capacity 7.5 HP
All as per serial item No. 47.00 here-in-before but motor of capacity 5 HP
All as per serial item No. 47.00 here-in-before but motor of capacity 3 HP
All as per serial item No. 47.00 here-in-before but motor of capacity 2 /1 HP
Taking out centrifugal motor of any capacity from foundation, dismantling the motor, taking out rotor and filling the material by welding work, finishing by lathe machine, replacement of unserviceable bearing, reassembling the motor and fixed in its original position complete all as specified and directed by Engineer-in-charge. Note: - (i) Bearing shall be measured and paid for separately as “Supply only” (ii) New Nuts, bolts and washers if required for refixing the motor shall be provided by the contractor, nothing extra shall be paid on this account.
Supply only Ball Bearing of suitable size for rotor of motor 75 HP installed complete all as specified and directed by Engineer-in-charge.
All as per serial item No 56.00 here-in-before but for motor of 50 HP.
All as per serial item No 56.00 here-in-before but for motor of 20 HP.
All as per serial item No 56.00 here-in-before but for motor of 15 HP.
All as per serial item No 56.00 here-in-before but for motor of 10 /12.5 HP.
All as per serial item No 56.00 here-in-before but for motor of 7.5 HP.
All as per serial item No 56.00 here-in-before but for motor of 5 HP.
All as per serial item No 56.00 here-in-before but for motor of 3 HP.
All as per serial item No 56.00 here-in-before but for motor of 1/ 2 HP.
Taking out defective centrifugal pump set , assembled with 75 HP elelctric motor, dismantling the pump set for carrying out repair / replacement of unserviceable parts such as CI impeller, Bush, ball bearing etc. reassembling, installing, commissioning and testing complete all as specified and directed by Engineer-in-charge. Note :(i) CI impeller, Bush & ball bearing required to replace shall be measured and paid for separately under respective items of BOQ as “Supply only”. (ii) The cost of transportation is included in the unit rate of this item nothing extra shall be paid on this account.
All as per serial item No 65.00 here-in-before but pump set assembled with 50 HP elelctric motor
All as per serial item No 65.00 here-in-before but pump set assembled with 20 HP elelctric motor
All as per serial item No 65.00 here-in-before but pump set assembled with 15 HP elelctric motor
All as per serial item No 65.00 here-in-before but pump set assembled with 10 /12.5 HP elelctric motor
All as per serial item No 65.00 here-in-before but pump set assembled with 7.5 HP elelctric motor
All as per serial item No 65.00 here-in-before but pump set assembled with 5 HP elelctric motor
All as per serial item No 65.00 here-in-before but pump set assembled with 2 /3 HP elelctric motor
Supply only ball bearing suitable for centrifugal Pump set assembled with 75 HP motor complete all as specified and directed by Engineer-in-charge.
All as per serial item No 73.00 here-in-before but assembled with 50 HP Motor
All as per serial item No 73.00 here-in-before but assembled with 20 HP Motor
All as per serial item No 73.00 here-in-before but assembled with 15 HP Motor
All as per serial item No 73.00 here-in-before but assembled with 10 /12.5 HP Motor
All as per serial item No 73.00 here-in-before but assembled with 7 .5 HP Motor
All as per serial item No 73.00 here-in-before but assembled with 5 HP Motor
All as per serial item No 73.00 here-in-before but assembled with 3 HP Motor
Supply only stainless steel Bush suitable for pump set assembled with 75 HP motor complete all as specified and directed by Engineer-in-charge.
All as per serial item No 81.00 here-in-before but assembled with 50 HP Motor
All as per serial item No 81.00 here-in-before but assembled with 20 HP Motor
All as per serial item No 81.00 here-in-before but assembled with 10 / 12.5 HP Motor
All as per serial item No 81.00 here-in-before but assembled with 7.5 HP Motor
All as per serial item No 81.00 here-in-before but assembled with 5 HP Motor
Supplying, laying & jointing in replacement submersible cable flat type, copper conductor of size 16 Sqmm 3 core complete all as specified & as directed by Engineer –in-charge.
All as per serial item No.87.00 here-in-before but 10 Sqmm 3 core.
All as per serial item No.87.00 here-in-before but 6 Sqmm 3 core.
All as per serial item No. 87.00 here-in-before but 4 Sqmm 3 core.
S&F as in replacement coupling assembly as per existing model & make suitable for centrifugal pump set assembled with 75 HP motor complete all as specified & as directed by Engineer –in-charge.
All as per serial item No. 91.00 here-in-before but assembled with 50 HP motor
All as per serial item No. 91.00 here-in-before but assembled with 20 HP motor
All as per serial item No. 91.00 here-in-before but assembled with 15 HP motor
S&F in replacement rubber coupling as per existing model & make suitable for centrifugal pump set assembled with 75 HP motor complete all as specified & as directed by Engineer –in-charge.
All as per serial item No. 95.00 here-in-before but assembled with 50HP motor
All as per serial item No.95.00 here-in-before but assembled with 20/30HP motor
All as per serial item No. 95.00 here-in-before but assembled with 15/10/7.5 HP motor
All as per serial item No. 95.00 here-in-before but assembled with 5 HP motor
S&F in replacement bakelite sheet of connection plate with cable connector suitable for 75 / 50 HP motor complete all as specified & as directed by Engineer –in-charge.
All as per serial item No. 100.00 here-in-before but suitable for 20 / 12.5 /10 HP motor
S&F in replacement cooling fan with locking aluminum cast type screw, as per existing type, suitable for 75 / 50 HP motor complete all as specified & as directed by Engineer –in-charge.
All as per serial item No. 102.00 here-in-before but suitable for 25 / 20 / 12.5 HP motor
All as per serial item No. 102.00 here-in-before but suitable for 10 / 7.5 HP motor
All as per serial item No. 102.00 here-in-before but suitable for 5 HP motor
S&F gland rope of size 10 sqmm or as required complete all as specified & as directed by Engineer –in-charge
M&L for taking out defictive submersible pump set of capacity 5 / 7.5 HP Capacity from bore well after disconnecting electrical connections, transportation to workshop for repair, dismantling the pump set for detection of repair such as rewinding of motor, replacement of iron stainer, bronze impeller, gun metal bushes stainless steel sleeve, impeller key, thrust bearing, replacement of unserviceable nut-bolts, washer, lugs, terminal plate, reassembling, lowering in well in its original position, making proper electrical connections, commissioning & testing complete all as specified and directed by Engineer-in-charge. Note : - (i) Cost for transportaion to workshop and carry back to site after repair is inlcuded in the unit rate of item nothing extra shall be paid on this acount. (ii) Rewinding of submersible motor, Iron stainer, bronze impeller, gun metal bushes stainless steel sleeve, impeller key and thrust bearing if required for replacement shall be paid separetly against respective items of BOQ as "Supply only". (iii) Lathe work and grinding of shaft if required shall be paid separately against respective items of BOQ. (iv) Cost of new nuts, bolts, washers, lugs and terminal plate required to be replaced is included in the unit rate of this item nothing extra shall be paid on this account.
All as per serial item No. 107.00 here-in-before but submersible pump set of capacity 10 / 12.5 HP
M&L for rewiding of submersible pump set of capacity 5 / 7.5 HP with PVC insulated copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts complete all as specified and as directed by Engineer –in-charge
All as per serial item No. 107.00 here-in-before but submersible pump set of capacity 10 / 12.5 HP
Supply only Iron stainer suitable for submersible pump of capacity 5 /7.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Iron stainer suitable for submersible pump of capacity 10/ 12.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Gun metal Bush suitable for submersible pump of capacity 5 / 7.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Gun metal Bush suitable for submersible pump of capacity 10 /12.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
S&F in replacement contactor ML-2, 3 phase 415 volts having auxillary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, 50 Hz of AC3 Rating 70 Amps and AC1 Rating 110 Amps complete all as specified and as directed by Engineer –in-charge. Make : L&T (type ML 2) Cat Part No SS90701 or equivalent of Siemens / English Electric / ABB / Legrand.
S&F in replacement contactor ML-3, 3 phase 415 volts having auxillary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, 50 Hz of AC3 Rating 70 Amps and AC1 Rating 110 Amps complete all as specified and as directed by Engineer –in-charge. Make : L&T (type ML 3) Cat Part No SS90721 or equivalent of Siemens / English Electric / ABB / Legrand.
S&F in replacement contactor MNX80, 3 phase 415 volts having auxillary contracts suitable for coil voltage 110 V, 220, 240 & 415 volts, complete all as specified and as directed by Engineer –in-charge. Make : L&T / Siemens / English Electric / ABB / Legrand.
S&F in replacement contactor MNX110, 3 phase 415 volts having auxillary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, complete all as specified and as directed by Engineer –in-charge. Make : L&T / Siemens / English Electric / ABB / Legrand.
S&F in replacement Digital type Voltmeter 96mm x 96mm, of range 0-500 volts, class -1, incl internal wiring with 1.0 sqmm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge
S&F in replacement Digital type Ammeter 96mm x 96 mm, single phase,as suitable range, class -1, incl internal wiring with 1.0 sqmm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge
S&F in replacement oveload relay, suitable for 10 HP to 40 HP motor, 3 phase, 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in replacement oveload relay, suitable for 50HP to 75 HP , motor 3, phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in soft starter, suitable for 15 HP pumpset ,3 phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in soft starter, suitable for 50 HP pumpset ,3 phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in replacement fully automatic star delta starter type ML2 FASD having relay of range 20 - 32 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge Make :- L&T Cat Part No SS90705 or equivalent Crompton Greaves / ABB / Schneider / Seimens
S&F in replacement fully automatic star delta starter type for 10 HP having relay of range 08 - 12 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge
S&F in replacement DOL starter range 13 - 22 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge Make :- L&T Cat Part NoSS96228 or equivalent Crompton Greaves / ABB / Schneider / Seimens
S&F in replacement DOL Starter range 28 - 42 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge Make :- L&T Cat Part NoSS96228 or equivalent Crompton Greaves / ABB / Schneider / Seimens
S&F in replacement single phase preventer type SDz5, SPPR + Timer, 415 V including necessary copper connection, lugs etc complete all as specified & as directed by Engineer-in-charge Make :- L&T Cat Part No XM818090000 /or equivalent in ABB or other similar technocommercial make.
S&F in replacement electronic timer type ET100, 110 / 240V, 50 HZ including necessary electric connection complete all as specified & as directed by Engineer-in-charge Make :- L&T Cat Part No SE 92003 or equivalent in ABB or other similar technocommercial make.
S&F in replacement on / off switch (push button) complete all as specified & as directed by Engineer-in-charge
S&F in replacement indicating lamp with holder and cover as per existing complete all as specified & as directed by Engineer-in-charge
S&F in replacement MCCB 4 Pole 100 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge. Make : Legrand Cat Part No. DPX 160 420055 or equivalent in L&T / Schneider / Standard
All as per item No. 133.00 here-in-before but MCCB 4 Pole, 125 Amps rating, breaking capacity 25 KA, 415 Volt Make : Legrand Cat Part No. DPX 160 420056 or equivalent in L&T / Schneider / Indoasian
All as per item No. 133.00 here-in-before but MCCB 4 Pole, 160 Amps rating, breaking capacity 25 KA, 415 Volt Make : Legrand Cat Part No. DPX 160 420057 or equivalent in L&T / Schneider / Indoasian
All as per item No. 133.00 here-in-before but MCCB 4 Pole, 250 Amps rating, breaking capacity 36 KA, 415 Volt Make : Legrand Cat Part No. DPX 250 420249 or equivalent in L&T / Schneider / Indoasian
All as per item No. 133.00 here-in-before but MCCB 4 Pole, 400 Amps rating, breaking capacity 36 KA, 415 Volt Make : Legrand Cat Part No. DPX 630 422007 or equivalent in L&T / Schneider / Indoasian
Repair/remarking to existing scale and indicator (water level indicator of RCC UG reservoir or over head reservoir) with & connecting wire & synthetic enamel paint as per colour code and as directed by Engr-in-Charge.
Supply and fixing in replacement emtork electric actuator valves with 3 ph induction motor 2 HP , 415 V ,AC 50 Hz, RPM 1500 ,complete as per existing make and model suitable for 150 mm valve opertion complete all as per specified and as directed. Model No : M1/030/A and M0/030/E , Make -Marsh or equivalent make.
Supply and fix Capacitor rating in KVAr normal three Phase Cylindrical Capacitors including connection and fittings. complete all as specified and directed by Engineer-in-charge.
S&F in repair fan belt B-32 of air compressor.The fan belt B-32 shall be ISI marked best quality and shall be approved by GE before incorporation in the work complete all as specified and directed by Engineer-in-charge.
Supply and laying in repair rubber mat of size 2 m x 1 m x 19mm thick complete all as specified and directed by Engineer-in-charge.
Supply and fix pressure gauge air water meter of pressure range 0-10 kg/Sqcm complete all as specified and directed by Engineer-in-charge.
M & L for Earthing complete with copper plate 60×60cm.× 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion
S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3 1/2 core. complete all as specified & as directed by Engineer –in-charge.
Supply and fixing in replacement emtork electric actuator valves with 3 ph induction motor 2 HP , 415 V ,AC 50 Hz, RPM 1500 ,complete as per existing make and model suitable for 350 mm valve opertion complete all as per specified and as directed. Model No : M1/030/A and M0/030/E , Make -Marsh or equivalent make.
Supply and fix in repair flanged GI pipe medium grade 50mm bore (as suction line of pump) including cutting threading welding of flange etc with GI fitting such as bend, flange, reducers etc including taking out old existing suction line.
S & F for LED sign board of size 4 X 4 including writing of installations details as directed by engr in charge and including stand with 40mm x 6mm thick angle iron with flat strip including welding, cutting & installed at site incl two coats of mettallic paint over a coat of mettallc primer with PCC locking arrangement complete and pcc copping 1 :2 :4 all as specified & directed by the Engineer-in-Charge.
L C ASSOCIATES (BID ID -3094811)
Shri Electrical Enterprises (BID ID -3090394)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .