Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC POST MISAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹45.0 L+₹2.3 L (5.36%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹49.6 L+₹6.9 L (16.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹97,400
Closing Date
5 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MISSAMARI
PO-Missamari Dist-Sonitpur Assam
PROVN OF LIGHTS ALONG THE MAIN ROAD ADJACENT TO FAMILY ACCN FROM REKHAMARI TCP AND PROVN OF CERTAIN REV AND MINOR WORKS UNDER GE MISSAMARI
2024_MES_658884_2
8475/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE MISSAMARI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE MISSAMARI
₹97,400
Yes
25 Sept 2024
12 Jul 2024
7 Sept 2024
12 Jul 2024
5 Sept 2024
19 Jul 2024
13 Jul 2024 - 17 Jul 2024
Amount
Supply, erection and fixing steel tubular swaged poles complete with cast iron base plate , finial taper plug bolt nuts and washer 9.0 Mtr long type 410 SP -31 including painting with two coats of Aluminium paint over a coat of red oxide primer (Externally from top of coping), applying two coats of black bituminous paint in the enbedded portion of Pole in concete complete all as specified and as directed. NOTE : Excavation, earthwork, PCC foundation and coping shall be measured and paid seperately.
S&F steeet light bracket made out of 32mm bore light grade pipe, 1.2 mtr long bend to shape as directed and fixing with 40mm x 5mm MS flat of suitable length and suitable size nuts bolts etc as required including necessary preperation of surfaces of MS clamp anf applying two coats of Aluminium paint over a coat of red oxide primer complete all as specified and as directed.
S&F energy saving & environment friendly long life 60 Watt,(or nearest next higher wattage) CT ≥ 6500 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy > 110 lumens/Watt, power factor ≥ 0.90, operating range 140 to 270 V, 50 Hz complete and connecting up with copper conductor cable of suitable size all as specified & as directed. Note:- Copper cable for connection will be measured and paid seperately under appropiate item
S&F thermoplastic cable junction box for street light, IP 66, size 205 x 255 x 112 mm, comprising of bus bar of suitable size mounted on epoxy insulators with incomming and outgoing terminal for cable connection including one MCB SP 10Amps 10KA, fixed with pole with necessary MS flat iron, nuts bolts as required complete all as specified & as directed.
S&F 2.5Sqmm PVC insulated weather proof, sheathed,3 core, multistranded copper conductorrun through pole for connection from junction box to light fitting connector block complete all specified & as directed.
M&L PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation of pole/copping, mass concrete including necessary formwork ad required complete all as specified and as directed.
M&L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation of pole, mass concrete including necessary formwork ad required complete all as specified and as directed.
M&L 50mm thick PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in floor finished even and fair without using extra cement complete all as specified and as directed.
Excavation in trenches n.exc. 1.5 m width and n.exc. 1.5 m in depth for foundation, laying of UG cable, pipe etc in soft/loose soil & getting out, complete all as directed.
Returning filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm, complete all as specified and directed.
Removing excavated material (soil) n exc 50 m & depositing where directed at a level n exc 1.5 m, complete all as directed.
M&L sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed.
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
M&L for 40mm bore GI pipe light grade with all necessary fittings (ISI marked) as in cable protection fixed to pole with MS clamps nuts bolts etc/,laid in trenches/road/floor complete all as specified and as directed.
M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means of bolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab (1:2:4, type B1)reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
M&L Single Phase Street light Panel, Astronomocal type, with maximium load 6 KW, Contactor rating 32 Amps, three pole and having 40 Amps TPN MCB fixed with MS flat of adequate size, nut bolts etc as required complete all as specified and directed.
Supply, installation, testing and commissioning of centrifugal pumping set spilt case with discharge of 300cum per hour at 15 mtrs head, coupled with 4 Pole, 50HP Capacity motor along with accessories. CI casing, Bronze impleller,CS shaft, gland packed, base frame, coupled fuard etc including preperation of foundation as per manufactueres specification and coonection of pipe with required fittings complete all as specified and as directed.
S&F thermoplastic cable junction box for street light, IP 66, size 225 x 295 x 122 mm, comprising of bus bar of suitable size mounted on epoxy insulators with incomming and outgoing terminal for cable connection including one MSB SP 10Amps 10KA, fixed with pole with necessary MS flat iron, nuts bolts as required complete all as specified & as directed.
S&F energy saving & environment friendly long life 45 Watt,(or nearest next higher wattage) CT ≥ 6500 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy > 110 lumens/Watt, power factor ≥ 0.90, operating range 140 to 270 V, 50 Hz complete and connecting up with copper conductor cable of suitable size all as specified & as directed. Note:- Copper cable for connection will be measured and paid seperately under appropiate item
M&L PCC (1:2:4) type B-2 (using 40 mm graded stone aggregate) as in copping to poles including necessary formwork ad required complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 4 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
S&F 25mm bore GI pipe Heavy grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F 15mm bore GI pipe Heavy grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F 25mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F 15mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
M&L surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed. Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.
S&F Switch piano, flush type single pole, one way 5/6 Amp complete all as specified and as directed.
S&F ceiling rose, 3 phase PVC/ polycarbonate, insulated body, three terminals, complete all as specified and as directed
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed.
M&L for cutting brickwall for making hole for fixing exhaust fan of size 300mm sweep and making good the distrubed surfaces of wall and finishing the surfaces as per existing finishes complete all as specified and as directed.
Shree Krishna Traders (BID ID -3086843)
M/s B.M. Enterprise (BID ID -3073770)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .