Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹26.0 L+₹52,355 (2.05%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹26.2 L+₹75,455 (2.96%)Rejected-Finance 40 VISHNU VIHAR KHERAI SHAMSHABAD ROAD KHERAI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹26.4 L+₹96,654.65 (3.79%)Rejected-Finance JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Meeting Eligibility Criteria |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
8 Jun 2020, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Outsourcing and resources for Operation and management of E/M installation at Chandan and Ramgarh under GE (AF) Jaisalmer
2020_MES_344877_1
8656/GE/E8
Open Tender
Miscellaneous Works
Item Rate
335 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹54,000
Yes
23 Jun 2020
14 May 2020
10 Jun 2020
14 May 2020
8 Jun 2020
27 May 2020
Amount
Schedule 'A' Part-I General Note as applicable for serial item No 2.00 & 3.00 of BoQ/Sch 'A' Contractors attention is hereby invited that estimated cost of serial item No 2.00 & 3.00 is Rs. 16,50,000.00 based on prevailing rates of Schedule of Minimum fair wages. Quoted amount against serial item No. 2.00 & 3.00 is less than the amount the work (Estimated of serial item No. 2.00 & 3.00 of BoQ/Sch 'A') then lowest bidder will have to deposit FDR in favour of Accepting Officer within 07 days from financial bid opened difference in Estimated cost & quoted amount of serial item No. 2.00 & 3.00 before evaluation of financial bid for acceptance of tender, failing which lowest tender will not be accepted. FDR submitted at the time of Acceptance of bidder will be realesed only after satisfactory proof of payment of deployed person under the respective serial item No. 2.00 & 3.00 of BoQ.
Manning and Operation of 11 KV Sub Station, Chandan 3 AFRU One (Skilled Electrician) in three shift of 8 hours each for 24 hours continuous operation in a day (including Sunday/Holiday) to maintain sub station, HT/LT day to day complaint & including daily, weekly check-up, monthly, quarterly and half yearly maintenance as per maint schedule as specified under particular specification with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge.
Note for item No. 2.00 (a) The contractor shall take over all equipment in serviceable condition at the time of commencement of contract and shall hand over in the same state at the time of completion of contract period. Any damage/loss shall be made good by the contractor at the time of completion of contract. GE's decision will be final and binding. (b) Daily cleaning of all Panels, transformers, recording meter readings. (c) Daily cleaning of all rooms viz floor, walls and ceiling fan including internal electrical fixtures. (d) No unauthorized person shall be allowed to enter in sub division. (e) 11 KV Sub Station will be operated 24 hours round the clock including Sunday/Holidays. (f) All T&P insulating cloths, for operators, log-books, instruction board duly laminated for 'DO or "NOT DO" Fire safety instruction board etc. shall be provided by the contractor. (g) During maintenance & operation of 11 KV Sub station, any parts found defective and require to be replaced same will be measured and paid under Schedule 'A' Part-II. (h) Contractor shall be responsible for group insurance for eleven month of manpower deployed by him against the contract.
Note for item No. 2.00 (Contd...) (j) Contractor shall provided proper uniform of the operator as deployed by him and dress code shall be approved by GE/AGE concerned. (k) Daily attendance register shall be maintained by both contractor and concerned JE and register weekly putup to concerned AGE for the record purpose. (l) Labour deployed by the contractor shall be responsible for complete area cleaning of 33 KV installation inside / outside all as specified and directed by Engr-in-Charge. (m) Fuel for operation of DG Sets shall be supplied by the Department as free for filling only. However storage facilities of fuel and collection of fuel from MES Store shall be provided by the contractor. (n) Daily log sheet for running hours, fuel consumption register shall be maintained by the contractor and signed by the JE /Other superintending staff employed by the contractor. (o) Daily checking of oil level, Oil pressure, priming, frequencey temperature shall carried out and records shall be maintained.
Manning and Operation of 11 KV Sub Station, Ramgarh unit One (Skilled Electrician) in three shift of 8 hours each for 24 hours continuous operation in a day (including Sunday/Hiliday) to maintain sub station in/out side HT Panels as specified, including daily and weekly check-up, monthly quarterly and half yearly maintenance as per Maint. schedule specified under particular specification with all minor consumable and expendable items and labour and tools for smooth and efficient operation all as specified and Directed by Engineer-in-Charge. Note for item No. 3.00 (a) The contractor shall take over all equipment in serviceable condition at the time of commencement of contract and shall hand over in the same state at the time of completion of contract period. Any damage/loss shall be made good by the contractor at the time of completion of contract. GE's decision will be final and binding. (b) Daily cleaning of all Panels, transformers, recording meter readings. (c) Daily cleaning of all rooms viz floor, walls and ceiling fan including internal electrical fixtures. (d) No unauthorized person shall be allowed to enter in sub division. (e) 11 KV Sub Station will be operated 24 hours round the clock including Sunday/Hilidays. (f) All T&P insulating cloths, for operators, log-books, instruction board duly laminated for 'DO or "NOT DO" Fire safety instruction board etc. shall be provided by the contractor. (g) During maintenance & operation of 11 KV Sub station, any parts found defective and require to be replaced same will be measured and paid under Schedule 'A' Part-II.
Note for item No. 3.00 (Contd....) (h) Contractor shall be responsible for group insurance for eleven month of manpower deployed by him against the contract. (j) Contractor shall provided proper uniform of the operator as deployed by him and dress code shall be approved by GE/AGE concerned. (k) Daily attendance register shll be maintained by both contractor and concerned JE and register weekly put up to concerned AGE for the record purpose. (l) Labour deployed by the contractor shall be responsible for complete area cleaning of 33 KV installation inside / outside all as specified and directed by Engr-in-Charge. (m) Fuel for operation of DG Sets shall be supplied by the Department as free for filling only. However storage facilities of fuel and collection of fuel from MES Store shall be provided by the contractor.
Schedule 'A' Part-II Servicing of HT, 11 KV VCB relays including calibration of IDMT relays through primary and secondary injection method and testing complete re-setting where required and ensuring proper functioning of earth fault and overcurrent relays including removing carbon deposits from contact points, spraying CRC spray and tightening fixed and moving contacts and ajdusting for smooth functioning including replacement of tripping and closing coils, 30 volt, DC and servicing solenoid switch complete all as specified and directed by Engineer-in-Charge.
S&F in replacement LED fittings of 45 watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection, impact resistance of IK07 & 10 KV complete with all accessries like nuts and bolts ,clip etc at wall, pole, roof all as specfied and directed. Make: Syska/CG/Havells /philips/GE
S&F in replacement surface and wall mounted LED tube light fittings of capacity 20 watt, Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver all as specified and directed by EIC. Make : Syska/Havells/CG Philips/GE
S&F in replacement surface and wall mounted LED tube light fittings of capacity 9 watt, basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver complete all as specified and directed by Engineer-in-Charge. Make : Havells Cat Part No. LHEXBQP7IN1W009 or equivallent in Philips/CG
S&F in replacement sheet metal enclosure powder coated single phase DB SPN 8 ways and neutral 240 Volts with 200 Amps rated bus bar double door suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces complete all as specified and directed by Engr-in-Charge. Make Legrand Cat Part No. 5076 11 or equivalent Standard/C&S/Havells
S&F in replacement sheet metal enclosure powder coated single phase DB SPN 4 ways and neutral 240 Volts with 200 Amps rated bus bar single door suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces complete all as specified and directed by Engr-in-Charge. Make Legrand Cat Part No. 5076 00 or equivalent Standard/C&S/Havells
S&F in replacement MCB, 10 to 40 Amps, Single Pole with Neutral, 240 Volts, repturing capacity 10 KA, 'C' curve, complete all as specified. Make : Legrand Cat Part No. 4086 18 or equivalent Havells/Schneider
S&F in replacement MCB, 10 to 40 Amps, Single Pole 240 Volts, repturing capacity 10 kA, 'C' Curve, complete all as specified. Make : Legrand Cat Part No. 4085 96 or equivalent Havells/Schneider
M&L for Sub main wiring with 6.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor FRLS 1100 volts grade conforming to IS 694 including and 6.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour drawn through in and including PVC conduit of suitable size and connecting terminal ends including taking down old unserviceable submain wiring complete all as specified by Engineer-in-Charge. Note : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
M&L for Sub main wiring with 4.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor FRLS 1100 volts grade conforming to IS 694 including and 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour drawn through in and including PVC conduit of suitable size and connecting terminal ends including taking down old unserviceable submain wiring complete all as specified by Engineer-in-Charge. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
S&F in replacement energy efficient LED street light fittings of 60 Watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection, individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings should be provided 5 KV surge protection external and a part from this surge, arrestor driver should have additional 4 KV surge protector in built in driver for maximised protections, should have lumens out put of 100 lumens watt minimum protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections complete all as directed. Make : Cromption Greaves Cat Part No. LSTP-60-CDL or equivalent in Philips / Orient /Havells / Wipro Note: 1. Driver should be BIS registered with "R" marking.
S&F MCCB, 4 Pole, 250 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal magnetic and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Legrand Cat Part No. 4202 49 or equavalent Indo Asian/Siemens/Havells/C&S.
S&F MCCB, 4 Pole, 200 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal magnetic and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Legrand Cat Part No. 4202 48 or equavalent Indo Asian/Siemens/Havells/C&S.
S&F MCCB, 4 Pole, 160 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal magnetic and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Legrand Cat Part No. 4202 48 or equavalent Indo Asian/Siemens/Havells/C&S.
S&F MCCB, 4 Pole, 125 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, thermal magnetic and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Legrand Cat Part No. 4200 56 or equavalent Indo Asian/Siemens/Havells/C&S.
S&F MCCB, 4 Pole, 100 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, thermal magnetic and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Legrand Cat Part No. 4200 55 or equavalent Indo Asian/Siemens/Havells/C&S.
S&F MCCB, 4 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, thermal magnetic and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Legrand Cat Part No. 4200 13 or equavalent Indo Asian/Siemens/Havells/C&S.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 95 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 50 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
S&F in replacement of ultra modern designed architectural, LED Recessed full open 2X2 Tile, Glare free uniform illumination with longer life and less maintenance, luminaire of capacity 36 watt which provides soft-light and suitable for armstrong/grid ceiling complete all as specified and directed. Make : Crompton Greaves Cat Part No. LCTLRN-36-FO-CDL or equivallent in Philips/GE/Havells.
M&L for repairing of complete LT Panel by welding of hings, door, including fixing Aldrop/Sliding door bolt with locking arrangement and layout the existing cable in proper manner by necessary excavation work and painting the panel as colour approved by Engineer-in-Charge
M&L for preparation of steel surfaces for electric poles upto 11.00 mtr long extension portion and apply one coat of aluminium paint over full length and making of pole number and five strips each 30cm wide in black & white colour using synthetic enamel paind upto 1.50mtr height from top of PCC foundation block complete all as specified and directed. Make of Paint : Asian/Narolac/Burger.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and complete to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 15mm bore, complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and complete to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 20mm bore, complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 25mm bore with & including all fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 25mm bore, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
M&L for galvanized steel water tubing medium grade of 40mm bore with & including all fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 40mm bore, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
M&L for galvanized steel water tubing medium grade of 50mm bore with & including all fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 50mm bore, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
M&L for galvanized steel water tubing medium grade of 80mm bore with & including all fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 80mm bore, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
S&F in replacement gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 50mm bore pipe line complete all as specified & directed by Engr-in-charge.
S&F in replacement gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 40mm bore pipe line complete all as specified & directed by Engr-in-charge.
S&F in replacement gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 25mm bore pipe line complete all as specified & directed by Engr-in-charge.
S&F in replacement gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 20mm bore pipe line complete all as specified & directed by Engr-in-charge.
M&L for 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe including disconnecting & taking down the existing water tank complete as specified in SSR Part-I
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for laying of cables, pipes, erection of poles, structs/stays etc not exceeding 10 sqm and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
M&L for stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
M&L for dry sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 23 mm thick sand stone slab pit cover etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
GM Construction Co.
S.D. And Company
M/s Ramesh & Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .