Sri J.M. Basumatary
O/o the Addl. Chief Engineer-cum-Director, PWD, BTC, Kokrajhar.
Proposed Construction of RCC Building G-2 Storied Grade-III Staff Quarters for PWD RnB Udalguri Division under SOPD-G fund for the year 2019-20.
2020_BTC_16480_1
27/KOJ/IFB/2016-17/Pt-I/23
Open Tender
Civil Works - Building
Item Rate
730 days
BTC
Refer to SBD
6 documents required · 6 mandatory
₹9,200
Principal Secretary, BTC, Kokrajhar
₹6.1 L
Yes
12 May 2020
14 Feb 2020
29 Feb 2020
14 Feb 2020
29 Feb 2020
14 Feb 2020
14 Feb 2020 - 29 Feb 2020
Amount
CIVIL WORKS: EARTHWORK IN EXCAVATION 1.1 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
1.3 Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (a) With earth or silt or sand obtained by head load with lead upto 90m and lift upto 2m
1.3 Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
4.1.1 Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
PLAIN CEMENT CONCRETE WORKS: 2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement : 3 sand : 6 coarse aggregate by volume
2.1.3 Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
SHUTTER WORKERS TIMBER SHUTTERING (FORMWORK) 3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (i) Using 38mm thick plank
PLYBOARD SHUTTERING (FORMWORK) GROUND FLOOR: 3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not excedding 1.0 M
3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.3 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200 mm in thickness.
3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.8 Staircase with sloping or stepped soffit including riser and stringers but excluding landing
1ST FLOOR: 3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not excedding 1.0 M
3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.3 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200 mm in thickness.
3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.8 Staircase with sloping or stepped soffit including riser and stringers but excluding landing
2nd Floor. 3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not excedding 1.0 M
3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.3 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200 mm in thickness.
3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.8 Staircase with sloping or stepped soffit including riser and stringers but excluding landing
3rd Floor: 3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not excedding 1.0 M
3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.3 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200 mm in thickness.
REINFORCEMENT CEMENT CONCRETE WORKS: 2.2.1 Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete
2.2.1 Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M20 grade concrete (1:1.5:3)
2.2.3 Extra over item nos. 2.2.1(I) (B) , above for each subsequent floor or part thereof above the 1st floor level . Above 1st floor level
2.2.3 Extra over item nos. 2.2.1(I) (B) , above for each subsequent floor or part thereof above the 1st floor level . Above 2nd floor level
2.2.3 Extra over item nos. 2.2.1(I) (B) , above for each subsequent floor or part thereof above the 1st floor level . Above 3rd floor level
MASONARY WORK 4.1.4 Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed (I) In - Substructure upto plinth lvl. including dewatering if necessary (b) In proportion 1:4 Upto plinth level
4.1.4 Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed (II) In superstructure above plinth level up to 1st floor level. (b) In proportion 1:4.(1 cement:4 sand)
4.1.5 Extra over item no. 4.1.5 above for brick work in each subsequent floor or part thereof above 1st floor level .
4.1.8 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement:4 sand)
6.2 CEMENT PLASTERING 6.2.1 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
6.2.2 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
6.2.3 20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) b) In cement mortar 1:4
6.2.5 Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffit of stair uo to first floor level (Instead of plastering on walls) including curing complete as directed.
6.2.6 Extra over item no 6.2.1 to 6.2.3 for interior plastering above 1st floor level for every addl. Floor level including curing complete as directed. (a) single coat
6.2.7 Extra over item no 6.2.1 to 6.2.3 for exterior plastering above 1st floor leve lfor every addl. Floor level including curing complete as directed. (b) double coat
ANTI-TERMITE TREATMENT 26.1 PRE CONSTRUCTION ANTI - TERMITE TREATMENT 26.1.1 Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
18.1 REINFORCEMENT WORKS Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer : TATA/ SAIL/ Esser Steel/ Jindal steel/ Shyam steel/ RINL (ii)TMT Corosion resistance steel (CRS) reinforcement bar
18.1.2 Extra over item on 18.1.1 for each subsequent floor or part thereof above first floor level ii. 1st Floor
18.1.2 Extra over item on 18.1.1 for each subsequent floor or part thereof above first floor level iii. 2nd Floor
18.1.2 Extra over item on 18.1.1 for each subsequent floor or part thereof above first floor level iii. 3rd Floor
5.7.1 CERAMIC TILES 5.7.1.2 B) ON WALLS Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed.(Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). a) Normal range Somany/ Orient/Nitco/Asian Make ii) Of size 200mmx300mm and above
5.11 ANTISKID TILES 5.11.1 Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. (A) CERAMIC ii)Executive range-1 (Sizes 400 mm x 400mm and above) (a) Somany made- VC Shield (Group- 25) (406x406) mm Deluxe -VC
5.10 GRANITE FLOORING 5.10.2 Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
13.3.4 Providing two coats of Birla White Wall Care Putty(Water Resistance White Cement based putty for concrete /mortar walls and celling both internal and external) after removing all loosely ahering from the wall surface with the help of emery stone ,putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department .(Total thickness of two coats is maximum 1.5mm) (i) Thickness =1.5 mm thick
WOOD WORK 9.1.2 Providing wood work in frame (chowkaths) of doors,windows,clerestory windows and other similary works wrought,framed and fixed in position in contact with C.C or brick masonry wal including supplying fitting and fixing with M.S hold fast (40 mm x 3 mm x250mm)as per design embeded in cement concrete block in proportion 1:2:4 and and with two coats of kiricide oiling to he timber faces in contact with C.C and masonry as directed and specified.(Wall in Audotorium) (b) 1st class timber (Bonsum / Sundi)
9.9.2 Providing ,fitting and fixing full panelled doors /windows including oxidies M.S butt hinges (100 mm x 75 mm x 3.55mm) with necessary screws(other fittings to measured and paid seperately) A) With Teak wood / Sisu Wood (ii) 35mm thick
12.2 Providing, fitting and fixing 24mm/ 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately) b) 29mm thick
11.1.1 Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. a)Side hung and Top hung windows and ventilators i) 6 mm clear glass
11.1.2 Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (a)2 Track sliding window (iii) 6mm coloured glass
11.1.2 Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (b)3 Track sliding window (iii) 6mm coloured glass
13 PAINTING 13.4 WALL PAINTING 13.4.7 Wall painting (two coats) with plastic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Plastic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
13.4.5 Extra over item no 13.4.1 above for painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on celling and on sloping roof. (i).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
13.9.6 Finishing wall with water proofing weather coat smooth anti -fungal exterior painting brand of Dulux (ISI)
13.6 PAINTING ON WOOD AND WOOD WOOD BASED SURFACES 13.6.3 Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter , sand papering and knotting. (b). With ready mixed paint, wood primer (white)
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
13.7 PAINTING ON STEEL AND OTHER METAL SURFACE 13.7.2 Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
13.7.4 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
15 DOOR AND WINDOW FITTINGS 15.2 ALUMINIUM FITTINGS 15.2.1 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) a) Sliding door bolts ii) 250mm x 16mm
15.2.1 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) b) Tower bolts iii) 200mm x 12mm
15.2.1 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) C) Door handles ii) 100mm
15.2.1 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) t) Door stopper with rubber stopper
GRILLS 10.2 Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. II . Ornamental grill (C) Fixed to Brickwork/P.C.C/R.C.C
18.4 COLLAPSIBLE / ROLLING SHUTTER 18.4.1 Providing and fixing in position Collapsible M.S shutter with vertical channels 20 mm x10mm x 2 mm braced with flat iron diagonals 20 mm x 5 mm x size with top and bottom rails of T- iron 40mm x40mm x 6 mm with 38 mm dia steel pulleys complete with bolts and nuts, locking arrangements ,stooppers ,handles including applying a priming coat of red lead paint.
PLINTH PROTECTION WORKS 19.5 Providing plinth protection with 50mm thick to cement concrete 1:3:6 with coarse aggregate of 20 mm nominal size inclding finishing the surface with 1:3 with a floating coat of neat cement
19.5 Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
SANITARY FIXTURES EUROPEAN TYPE WATER CLOSET Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) A) Parryware make/a) White/(vi) Elite P Trap (Cat No. C0278) (inclusive of seat cover)
PVC FLUSHING CISTERN Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make/a) White/(i)Economy Single Flush (Cat No.C8090/C8055)
WASH BASIN Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) 1.13.1 PEDESTAL BASIN (with pedestal) (A) Parryware Make/(a) White/(iv) Cascade NXT 550 x 440 with long Pedestal (Cat. No.C0404/C0380)
C.P FITTINGS & ACCESSORIES: KITCHEN SINK(STAINLESS STEEL) Providing fitting & fixing stainless steel kitchen sink of parryware make with CI/MS brackets,C.P. brass chain with rubber plug ,PVC waste pipe etc .complete including painting the fittings,cutting & making good the walls wherever required .(Sink cock,stop cocks,waste coupling are to be paid separately) (A) Parryware Make (v) Single bowl (240x 180) Flat Edge -Glossy (Cat no.Cat No.C8543)
MIRROR Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER Providing, fitting and fixing Liquid soap dispenser and liquid soap container complete as directed and specified. (i) Jaquar Make/(a) Continental (Cat.No.ACN-1135N) (with glass bottle)
Providing, fitting and fixing Chrome Plated TOWEL RACK complete as directed and specified. (a) Jaquar make/ (i) Continental (Cat.No. ACN-1191N)
WASTE COUPLING Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (a) Jaquar Make/(i) 32mm (HT/FT) (Cat.No.ALD-705 / 709)
TOWEL RAIL,TOWEL RACK & TOWEL RING Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified. (a) Jaquar Make/(i) Continental 600mm long with hanger (Cat. No. ACN-1181N)
BOTTLE TRAP Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. (a) Jaquar make (ii) Bottle trap (with internal partition) 32mm size with 300mm long wall connection pipe (Cat.No. ALD-769B)
BIB COCK Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (II) Jaquare make/ (a)Continental /Clarion (i)Standard
STOP COCK Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (I) Jaquar/(a) Continental / Clarion/(ii)15mm dia( Angular stop cock )
PIPES & FITTINGS PVC PIPES,BENDS,JUNCTIONS,TEES ETC. Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (ii) 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Providing and fixing Chlorinated Polyvinyle Chloride(CPVC) Pipes, having thermel stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00m spacing.This includes joint of pipe. (A)) Exposed or in trenches e) 40 mm nominal outer dia pipe
(B) Concealed pipe with cutting chases & making good the walls a) 15 mm nominal outer dia pipe
b) 20 mm nominal outer dia pipe
c) 25 mm nominal outer dia pipe
Socket, Reducing Socket Renewing G.I. Socket Zololot -m brand ,heavy a) 15mm OD
b) 20mm OD
c) 25mm OD
BEND Renewing G.I. BEND ,heavy quality as specified and directed a. 15mm OD
b. 20mm OD
c.25mm OD
TEE, REDUCING TEE, REDUCER Renewing G.I. TEE ,heavy quality as specified and directed a) 15mm OD
b) 20mm OD
c) 25mm OD
WATER TANK Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (I) 500 Lt capacity (a) Sintex make
SEPTIC TANK (50 USERS): EARTHWORK IN EXCAVATION Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
PLAIN CEMENT CONCRETE WORKS Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement : 3 sand : 6 coarse aggregate by volume
MASONARY WORK Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary. (d) In proportion 1:6.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in sub-structure upto plinth level. (A) 112mm thick brick wall (c) In cement mortar in proportion 1:6. (1 cement:4 sand)
CEMENT SAND PLASTERING 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
Neat Cement Punning
Providing fitting and fixing PVC cowel of ISI make complete as directed and specefied (II) 110 mm dia PVC cowel ISI make
Construction of filter bed in soak pit including earth eork of soil and filing earth ...... as mention in the table .
Construction of inspection pit inside measurement 450mm x 450mm flush with 100mm dia. HCL/PVC pipes and cement concrete base proportion 1:3:6 over flat brick soling in cement mortar .... As directed
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110 mm dia.
(iv) 75 mm dia.
DEEP TUBE WELL.: Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. vi) Bore hole of 200mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. II. PVC Pipe SUPREME /PRINCE / FUSION /SFMC Brand vii) 160mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. A. G.I. Pipe a) TATA / SAIL (Medium)socket should be welded to the pipes. iv) 50mm diameter
Supplying fitting and fixing brass Tez filter 2.00 metre long.
Supplying fitting and fixing check valve (non return valve) including thread to pipes. iv) 50mm diameter
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Flushing, clearing, washing and watering of the tube well
IRON REMOVAL WATER FILTER Supplying fitting and fixing iron removal filter filling with treated sand, pebbles, manganishdioxide and other required materials of various filtration rate per hour of DOLPHIN make with all necessary fittings such as valve,bib cock,pipe connection etc.with a free maintanance period of six months (A) With Zoloto fittings (I) 1000 liters capacity (a) 4 mm thick Vessel
MOTOR PUMP SET Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. 39.7.3 Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 2 HP STAGE 6 to 30 with MCB controlled Submersible motor pump set control panel.
ELECTRICAL WORKS: Providing and fixing I.C.T.P and N link Main Switch fuse units with H.R.C fuses( HPL/ GECO / ANCHOR or equivalent make) including drilling boards/iron frames and fixing with bolts and nuts and connection as approved by the Deptt.)complete as required 100 Amps Capacity
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 2.1 ABB, Schneider MG, legrand, Hager make) 2.1.1 6 way TPN (4+18) double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 3.1 ABB, Schneider MG, legrand, Hager make) 3.1.1 12 way SPN double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 4.2 C Series (Schneider MG, legrand, Hager make) 4.2.1 6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 5.1 C Series (ABB, Schneider MG, legrand, Hager make) 5.1.1 6 to 32A
Supplying with fitting and fixing TPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 6.1 C Series (ABB, Schneider MG, legrand, Hager make) 6.1.1 63A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 7.1 100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 7.1.1 25A
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. 8.1 With 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. 9.1 With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete 10.1 Medium point up to 6.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. 11.1 Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) 12.1 Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Supplying with fitting and fixing of 120 watt electronic modular STEP speed control 2 - module type MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. 13.1 120 watt electronic modular step speed control 2 - module type
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6 amp one way modular clip in bell push MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 10 Amps 3 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 1-2 module type Metal
3 module type Metal
4 module type Metal
6 module type Metal
8 module type Metal
9 module type Metal
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 1 module
2 module
3 module
4 module
6 module
8 module
9 module
Supplying and fixing 18 S.W.G sheet steel metal boxes of the following sizes in surface/ recessed Wiring system with suitable size of 3 mm thickness phenolic laminated sheet cover on the front face of the boxes including painting etc. as required and specified by the department. 100 mm x 150 mm x 60 mm deep (Nominal size
Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
Slim Surface mounted rectangular / round shaped LED panel light fittings (12 W LED 6000 K) with PDC aluminum housing and PMMA diffuser to give glare free light with removable driver similar to model LCDSPLN-R/S-12-CDL of Crompton or Equivalent
Slim Surface mounted rectangular / round shaped LED panel light fittings (6 W LED 6000 K) with PDC aluminum housing and PMMA diffuser to give glare free light with removable driver similar to model LCDSPLN-R/S-06-CDL of Crompton or Equivalent
Sleek LED based mirror light (7W) of 1 ft length similar to model LCL-7-CDL of Crompton or Equivalent
decorative LED Batten suitable for LED T8 lamps.along with Linear LED T8 tubular lamp with extruded aluminium body, PC diffuser and inbuilt driver. similar to model LTT8-16 and DMLN1LT8-16 of Crompton or Equivalent
Decorative, wall mounting, SS finish fixture with opal glass diffuser suitable for 40 W mini GLS lamp or 8 W TU retrofit CFL. similar to model LHJC02108499 of Havells or Equivalent
LED based bulkhead luminaries (10W) suitable for outdoor application similar to model LBH-10-CDL of Crompton or Equivalent
Supplying fitting and fixing of retrofit LED lamp in the existing brass bracke10Watt LED lamp
Supplying fitting and fixing 25w /30w LED street light fittings along with fixing bracket arrangement complete as required
Supplying fitting and fixing 70w LED flood light fittings along with fixing bracket arrangement complete as required
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. CROMPTON make) Premium model 1200 mm Sweep CROMPTON make
Standard model 900 mm Sweep CROMPTON make
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Trans Air 300 mm sweep (Crompton make)
Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.
Supplying including fitting fixing of following A.C. Wall fan in the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. (CROMPTON /ORIENT/Havells/USHA or equivalent make) SDX 120 with metal body metal blade 400 mm sweep
Supplying including fitting and fixing of Call bell indicator with register 6 A ,250 V A.C 1 way 5P 1 module complete as directed and specified by the deptt. (Model Ref. 573415 Legrand/ equivalent make) 1.Call bell with indicator(Legrand/ C&S or equivalent as approved by the Deptt.) make)
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 2 Core A2XWaY A2XFaY 10.00 Sq.mm 2 Core armoured U.G. cable
3 Core A2XWY A2XFY 6.00 Sq.mm 3 Core armoured U.G. cable
4 Core A2XWY A2XFY 50.00 Sq. mm.4 Core armoured U.G. cable
SUPPLYING FITTING AND FIXING OF (DOWELLS/ COMET make) SINGLE compression BRASS GLAND HEAVY DUTY SINGLE compression BRASS GLAND HEAVY DUTY Size: 7/8"
SINGLE compression BRASS GLAND HEAVY DUTY 1-1/4"
SINGLE compression BRASS GLAND HEAVY DUTY Size: 3/4"
SUPPLYING FITTING AND FIXING OF (DOWELLS/ COMET make) ALUMINIUM alloy tubular bimetallic terminal. Size: ALUMINIUM tube terminal. Size: 10
ALUMINIUM tube terminal. Size: 50
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 8 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt.
Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid G.I. tube having 85 mm dia. single prong at top and 3 mm base plate at bottom complete with fitting & fixing with G.I. nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt.
Supply with fitting & fixing 60 mm dia 1830 mm height integrated with acrylic diffuser, translucent top, bottom clear , black powder painted finish tubular pole .The pole is made of GI tube with GI cylindrical control box with service door and a circular base plate, pre-cabled with control gear, 36 W CFL lamp and suitable for operation on 240 V 50 Hz single phase AC supply . The pole is to be fitted on 1:3:6 PCC pole foundation of size 300 mmx300 mmx1200 mm with grouting nuts & bolts as specified & directed by the deptt .(Metal Coats make). COBRA model or equivalent.
FOR FIRE FIGHTING: Supply , Installatiuon, Fixing of CARBON DIOXIDE Fire Extinguisher conforming to IS: 2878 with ISI Mark (4.5 lt.) Brand: FIRESTOP / FIREND / FIRESHIELD
Supply , Installatiuon, Fixing of ABC Stored Pressure Fire Extingusher with built- In pressure Gauge to know the ready ness of the Extinguisher Squeeze Grip Handle As per IS: 13849 with ISI mark (05 kg capacity.) Brand: FIRESTOP / FIREND / FIRESHIELD
LANDSCAPING : Supplying and planting of terrestrial orchids with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (A) With Aeirides (I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
Supplying and planting of palms with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (A) With Bottle palm (I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
(D) With Fan Palm /Finger palm (I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
Supplying and planting of seasonal flower in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
Supplying and planting of cactus in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, sand, cow-dung, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (A) With Peanut Cactus / Rat tail Cactus (I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(B) With Prickly pear (I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(C) With Parodia globular (I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
BED PLANTING Supplying and planting of Dahlia / Chrysanthemum / Gladiolus on the ground ( bed planting, bed size 45 cm x 45 cm x 45 cm) including the preparation of the soil, providing organic manure and fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed .
(B) With Hybrid tea rose / Miniatune rose
HEDGE PLANTING / EXTERNAL HEDGE Supplying and planting of suitable plant materials for preparation protective / external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) ADOPTING SINGLE ROW PLANTING METHOD (i) With Duranta
(ii) With Kamini
(iii) With Chinese Bamboo
(iv) With Thuja / Ixora
EDGE PLANTING / INTERNAL HEDGE Supplying and planting of suitable plant materials for edge making / Internal hedge(20 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) ADOPTING SINGLE ROW PLANTING METHOD (i) With Duranta
(ii) With Coleus
(iii) With Brindavan / Latifolius
(iv) With Acalypha wilkesiana
(v) With Acer palmatum
BOUNDARY WALL: EARTHWORK Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling(return filling) the quantity as necessary after completing of work, breking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in hard / dense soil including bailing out water where necessary as directed and specified.
PLAIN CEMENT CONCRETE Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately). (a)In prop. 1 cement : 3 sand : 6 coarse aggregate by volume 1. Foundation of RCC column 2. Under tie beams
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately). (a)In prop. 1 cement : 3 sand : 6 coarse aggregate by volume 2. In coping over wall
FORMWORK Providing form-work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 M. And reemoval of the same for in-situ reinforced concrete and plain concrete work. 3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (i)Using 38mm thick plank 1. Foundation base of RCC column 2. Tie beam sides
Columns, pillars, posts, struts . (i) Using 38mm thick plank (a) (i) 1. RCC columns upto tie beam 2. RCC columns above tie beam
Providing form-work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 M. And reemoval of the same for in-situ reinforced concrete and plain concrete work. 3.1.1.4 (a) (I) 3. In coping bottom 4. In coping sides
REINFORCEMENT Supplying, fitting and fixing in position (b)TMT Bar 1. Foundation base
REINFORCEMENT CEMENT CONCRETE Providing and laying plain/reinforced cement concrete works in prop 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone chips, 20mm down ) including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (i) In substructure up to plinth level Foundation, footing, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick. 1. column base
(ii) In super structure from plinth level up to 1st floor level. (b) Columns,pillars,posts,struts,suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing. 1. Columns
BRICWORK Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level. (c ) In proportion 1:5 (1 cement : 5 sand) 115 thick
PLASTERING 20 mm thick cement plaster in two coats, backing coat 10 mm and finishing coat 10mm thick on fair side of brick/stone masonry walls for interior plastering up to 1st floor level including arises, internal round angles,not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3 1. Wall
PAINTING Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Finishing old/ new wall with waterproofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian paints of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
MS Gate: Civil Works: Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling(return filling) the quantity as necessary after completing of work, breking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in hard / dense soil including bailing out water where necessary as directed and specified. (A)Upto adepth of 2.00m below the existing G.L (b)In hard / dense soil Foundation of RCC column
CEMENT CONCRETE WORK Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately). (a)In prop. 1 cement : 3 sand : 6 coarse aggregate by volume 1. Foundation of RCC column 2. Under tie beams
Providing and laying plain/reinforced cement concrete works in prop 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone chips, 20mm down ) including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) In substructure up to plinth level Foundation, footing, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick. 1. column base
In super structure from plinth level up to 1st floor level. (b) Columns,pillars,posts,struts,suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing. columns
FORMWORK Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Sub-structure 3.2.1.1 1. Foundation base of RCC column
2. Tie beam sides
Super-structure 1. RCC columns upto tie beam
STEELWORK Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) (b)TMT Bar 1. Foundation base
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ opening with M.S. flats at required spacing in frame all round, square or round M.S.bars with round headed bolts and nuts or screws. Ornamental grill Fixed to Brickwork/P.C.C/R.C.C. 1. 12mm square bars
PLASTER WORK 20 mm thick cement plaster in two coats, backing coat 10 mm and finishing coat 10mm thick on fair side of brick/stone masonry walls for interior plastering up to 1st floor level including arises, internal round angles,not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3 1. Sides
PAINT WORK Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Dulux (ICI) paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
brick DRAIN: EARTHWORK Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling(return filling) the quantity as necessary after completing of work, breking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in hard / dense soil including bailing out water where necessary as directed and specified. (A)Upto adepth of 2.00m below the existing G.L (b)In hard / dense soil Drain of 450 mm average depth
CEMENT CONCRETE WORK Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately). (a)In prop. 1 cement : 3 sand : 6 coarse aggregate by volume 1. Drain
BRICK WORKS Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level. (c ) In proportion 1:5 (1 cement : 5 sand) 230 mm thick 230 thick boundary wall side
230 thick landscape side
PLASTER WORK Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
EARTHWORK Clearing and Grubbing Road Land.( Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to be used or auctioned upto lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm thickness. (ii) By Mechanical Means A. In area of light jungle
Excavation in Soil using Hydraulic Excavator CK 90 & Tippers with Disposal upto 1000metres.(Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting & loading in tippers, trimming bottom & side slopes, in accordance with requirements of lines, grades & cross sections, loading & disposal of cut road with in all lifts & leads upto 1000 metres)
Construction of Subgrade and Earthen Shoulders ( Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table (300-2) (a), (Including cost of testing of materials at site and laboratory as directed by the deptt.) (b) from private land
Construction of Embankment with Material Deposited from Roadway Cutting ( Construction of embankment with approved materials deposited at site from roadway cutting & excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2.)
(C) Cost of haulage excluding loading and unloading for a distance of 64 kms on surfaced gravel road.
GSB Granular Sub-base with Close Graded Material (Table:-400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per cl. 401( with an initial lead of 5 Km.) (i) for grading-I Material
Cost of haulage excluding loading and unloading for a distance of 64 kms on surfaced gravel road.
WBM Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fill up the interstices of coarse aggregate, watering and compacting to the reqd. density ( with an initial lead of 5.0 km.) A. By Manual Means (I) Grading I (a) Using Screening Crushable type such as Moorum or Gravel
Cost of haulage excluding loading and unloading for a distance of 64 kms on surfaced gravel road.
PAVER BLOCK Providing and laying 40 mm thick factory made cement concrete paver block of M - 30 grade factory made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50 mm thick compacted bed of course sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer - in - Charge at all levels. A. SUNROCK HIGH CTS tiles (Pavers) (a) (Pavers) 80mm thick
RAISING LOW SITE: Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods,dressing etc. complete including paying nessary forest royelty,sales tax,land compensation,municipal gate fees,if any monopoly duty etc.(profile measurement to be taken and 12.5%deduction for shinkage to be made from total quantity)etc.conplete as directed and specified. b. other than guwahati city.
IINTERNAL DECORATION & FURNITURE WORKS: BED ROOM (VIP): Curtain full length high quality decorative cloth
Decorative pate made with male with ornamental stopper gard
Cot made CP wood Victorian leg polished with Malmain lagur finished with bed side
Matress curior made high quality full size
Light cussion made by silly silky designed stretched weld full size
Blanket cover with up holstair white cloth
Bed sheet white high quality Bombay Dying
Pillow High Quality Feather Fibre Cussion
Pillow Cover Full Size White
Pillow Towels White Color Bombay Dying
Bed Side Carpet Vension Type Size 6" x4"
Wardrop with inbuilt dressing table , made by % B. Board water proof beach teak wood finished malamute polished with bed side table
Bedside easy chair with sophisticate up holstair
DIESEL GENERATOR: Supplying including installation, testing and commissioning of Water Cooled Jackson Diesel Generator set coupled to suitable alternator of 415 V, AC, 3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF/Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the following Technical Specification.. (RANGE FROM 15 KVA TO 625 KV TECHNICAL DATA CJ50D5P GENERATOR SET SPECIFICATIONS 50/40 3. No. of Phases. 3 phase. 4. POWER FACTOR 0.8 LAG JACKSON ENGINE SPECIFICATION. 1. make). Cummins 2. Model. 53.8-G6 3. No. of Cylinders. 4 4. Aspiration. TURBO CHARGED 5. Cooling. Water Cooled. 6. Governor. Mechanical 7. Battery Capacity Rating. 12 Volt. 8. FUEL CONSUMPTION LTR/HR @ 75% LOAD 9.3 ALTERNATOR SPECIFICATION. 1. make). CGT (STAMFORD) 2. Voltage Regulation. +/- 1.0% 3. Insulation. Class - H. 4. Standard Enclosure. IP 23 5. No. of Phases. 3 WITH STANDARD CONTROL PANEL
Sajal Sengupta
Manas Das
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .