| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.0 LAdmitted-Finance PULLIYIL PARAMMA THODY HOUSE MELMURI PO MALAPPURAM 676517 | MALAPPURAM | KERALA | 676517 | ₹68.0 L | L1 | Admitted-Finance |
| 2 | L2₹74.9 L+₹6.9 L (10.2%)Admitted-Finance | ₹74.9 L+₹6.9 L (10.2%) | L2 | Admitted-Finance |
| 3 | L3₹76.1 L+₹8.1 L (11.9%)Admitted-Finance KOUSTHUBAM 31 76A 1 MAYANAD KOZHIKODE 673008 | KOZHIKODE | KERALA | 673008 | ₹76.1 L+₹8.1 L (11.9%) | L3 | Admitted-Finance |
| 4 | L4₹76.9 L+₹8.9 L (13.1%)Admitted-Finance | ₹76.9 L+₹8.9 L (13.1%) | L4 | Admitted-Finance |
| 5 | L5₹79.6 L+₹11.6 L (17.0%)Admitted-Finance | ₹79.6 L+₹11.6 L (17.0%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | CIS GLOBAL INFRATECH PVT LTD L7 | SIRAJUDHEEN P.P. L1 | BETHLAHEM CONSTRUCTIONS L4 | K V SANKARANKUTTY L8 | Celmech Engineering Pvt.Ltd L3 | M.K MOIDEEN L2 | Jayakumar V V L6 | HRL ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00REINFORCED CEMENT CONCRETE | |||||||||||
| 1.01Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: | |||||||||||
| 1.01 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 100 | cum | 11,700 ₹11,70,000 | 9,800 ₹9,80,000 Lowest | 10,500 ₹10,50,000 | 10,900 ₹10,90,000 | 9,800 ₹9,80,000 Lowest | 11,500 ₹11,50,000 | 11,000 ₹11,00,000 | 12,400 ₹12,40,000 |
| 1.02Centering and shuttering including strutting, propping etc. and removal of form for | |||||||||||
| 1.02 | Lintels, beams, plinth beams, girders, bressumers and cantilevers | 435 | sqm | 800 ₹3,48,000 | 580 ₹2,52,300 | 800 ₹3,48,000 | 340 ₹1,47,900 Lowest | 450 ₹1,95,750 | 750 ₹3,26,250 | 800 ₹3,48,000 | 790 ₹3,43,650 |
| 1.03Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. | |||||||||||
| 1.03 | Thermo-Mechanically Treated bars of grade Fe-500D or more. | 8,000 | kg | 122 ₹9,76,000 | 100 ₹8,00,000 | 94 ₹7,52,000 Lowest | 114 ₹9,12,000 | 100 ₹8,00,000 | 100 ₹8,00,000 | 125 ₹10,00,000 | 98 ₹7,84,000 |
| 2.00MASONRY WORK | |||||||||||
| 2.01Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer | |||||||||||
| 2.01For superstructure above plinth level up to floor five level, including all cost of materials, labour charges etc. | |||||||||||
Tender Value
₹80.5 L
EMD Value
₹1.6 L
Closing Date
16 Jul 2026, 6:00 pmClosed
Director
NIT Calicut, NIT Calicut Campus PO, Kerala, 673601
Vertical extension of boundary wall around 12th mile ground by increasing the height with solid block masonry wall and barbed wire fencing
2026_NITC_914792_1
Engg/D1/JE3/504/2026-27
Open Tender
Civil Works
Item Rate
180 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1.6 L
Yes
3 Sept 2026
25 Jun 2026
20 Jul 2026
25 Jun 2026
16 Jul 2026
25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1REINFORCED CEMENT CONCRETE | |||||
| 1.01 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: | - | - | - | - |
| 1.0101 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | - | cum | - | - |
| 1.02 | Centering and shuttering including strutting, propping etc. and removal of form for | - | - | - | - |
| 1.0201 | Lintels, beams, plinth beams, girders, bressumers and cantilevers | - | sqm | - | - |
| 1.03 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. | - | - | - | - |
| 1.0301 | Thermo-Mechanically Treated bars of grade Fe-500D or more. | - | kg | - | - |
| 2MASONRY WORK | |||||
| 2.01 | Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer | - | - | - | - |
| 2.0101 | For superstructure above plinth level up to floor five level, including all cost of materials, labour charges etc. | - | - | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_961351.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .