Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC | L1 | Accepted-AOC M/S GANESH CONSTRUCTIONS IS THE LOWEST BIDDER, HENCE ACCEPTED | |
| 2 | L2₹40.0 L+₹4.6 L (13.0%)Rejected-Finance | L2 | Rejected-Finance Other Than L1 Bidder | |
| 3 | L3₹43.9 L+₹8.5 L (24.1%)Rejected-Finance | L3 | Rejected-Finance Other Than L1 Bidder | |
| 4 | L4₹44.1 L+₹8.7 L (24.6%)Rejected-Finance H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | L4 | Rejected-Finance Other Than L1 Bidder | |
| 5 | L5₹44.2 L+₹8.8 L (25.0%)Rejected-Finance | L5 | Rejected-Finance Other Than L1 Bidder |
Tender Value
₹43.1 L
EMD Value
₹86,200
Closing Date
29 Aug 2023, 6:00 pmClosed
Garrison Engineer Kota
Dadwara Complex, Military Station Kota - 324002
SPECIAL REPAIR TO SINGLE OR ACCN BLDG NOS. T-20, T-21 AND T-22 IN CENTRAL SECTOR AND PROVN OF COVERED SHED ALONGWITH HARD STANDING OF CERTAIN UNITS AT MIL STN KOTA
2023_MES_603086_1
8728/E8
Open Tender
Civil Works
Item Rate
183 days
KOTA
Contractor shall be enlisted with MES in Class D and above and category a(i) subject to satisfactory remarks wrt performance in respect of works in hand as reflected in Work Load Return (WLR) or any other report circulated by competent engineer a
8 documents required · 8 mandatory
₹500
GE KOTA
₹86,200
Yes
2 Dec 2023
10 Aug 2023
31 Aug 2023
10 Aug 2023
29 Aug 2023
24 Aug 2023
10 Aug 2023 - 19 Aug 2023
Amount
Taking down cement plaster of any description and thickness on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Taking down chowkhat or frames not exc 1.50 Sqm each with shutters (with out taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhat or frames exc 1.50 Sqm and not exc 4.00 Sqm each with shutters (with out taking off shutters from the frame), complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for and removing rubbish from premises, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and pavings n.exc 15 cm thickness (below or above GL) and removing rubbish from premises, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, any thickness incl hooks and ridge as retrieved from site complete all as specified and directed.
Dismantling floor, hearth or wall tiling/ terrazzo including cement mortar bedding (but not backing), removing tiles and rubbish off the premises, complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles, complete all as specified and directed.
M&L walling of random rubble, uncoursed well bonded, bedded and solidly hearted, built in Cement Mortar 1:6, including finishing the joint, flush as the work proceeds complete all as specified and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc. 40mm to face stones and dressing or face beds and joints, as specified, of random rubble walling, uncoursed or bourght upto courses complete all as specified and directed.
M&L brick work with old size pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), straight or curved on plan exc 6 m mean radius, built in CM 1:6, complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggreate), 75 mm thick as in plinth protection/Path/PCC paving etc including finishing the surface even & smooth without using extra cement, with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where dirtected and providing 6 mm wide joints throughout the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three parts of fine sand by weight), complete all as specified & directed.
M&L for 75mm thick PCC 1:2:4 mix, type B1 (using 20mm graded crushed stone agg) as in path/hard standing etc, finishing surfaces even and smooth without using extra cement, laid in panels, complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 mix, type B1 (using 20mm graded crushed stone agg) as in path/hard standing etc, finishing surfaces even and smooth without using extra cement, laid in panels, complete all as specified and directed.
Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, for thickness of concrete slab 100mm complete all as specified and directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound, Grade ‘A’, complete all as specified and directed.
M&L for PCC 1:4:8 type D-2, using 40 mm graded crushed stone aggregate, as in foundation, filling, mass concreting etc, complete all as specified and directed.
M&L for PCC 1:3:6 type C-2, using 40 mm graded crushed stone aggregate, as in foundation, filling, mass concreting etc, complete all as specified and directed.
S&F 35mm thick factory made IInd Class Hard wood (Hollock) paneled door shutters single panel with lock rail and panel of 9mm B.W.P. marine grade plywood bonded with high quality liquid phenol formaldehyde synthetic resin adhesive conforming to IS-710 or 12mm thick particle board veneered with commercial veneering on both faces. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed.
S & F factory made steel windows conforming to IS-1038 with side hung shutters including projection type hinges with 2 Nos MS 100mm size tower bolt over MS flat iron for each openable leaf & Z section handles & steel pag stay complete (with glazing bars), dovetailed or welded including fixing of lugs in PCC 1:2:4, type B-1, using 20mm graded stone aggregate & making good walls & cills to match the existing and including one coat of red oxide/ zinc chrome primer complete all as specified and directed. Note :- Glass/SS or MS cloth wire shall be measured and paid for separately under respective items.
S&F of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor, overall length of cover plate 140 mm, complete all as specified and directed.
S&F for 150 mm mild steel barrel tower bolts, stove enamelled black with bright bolts and fixed, complete all as specified and directed.
S&F 100 mm size mild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws, complete all as specified and directed.
S&F 150 mm size, mild steel pressed handles, oval type, stove enamelled black, ISI marked complete all as specified and directed.
S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed.
S&F sheet glass 3mm thick ordinary quality and glazing with oil putty etc in squares n.exe 0.50 Sqm in each pane, complete all as specified and directed.
S&F Powder coated (thickness of powder coating minimum 50 micron) anodised aluminium frame for doors, windows, ventilators & partition etc., with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F Powder coated (thickness of powder coating minimum 50 micron) anodised aluminium window and ventilator shutters, side hung without sash bars, aluminium sections weighing 0.55 kg/m & including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21 100mm long (2 No.), suitable handle (1 No), complete all as specified and directed. Note :- Wire cloth & Glass pane shall be measured and paid for separately.
S&F Powder coated (thickness of powder coating minimum 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. Note :- Wire cloth & Glass pane shall be measured and paid for separately.
Supply, fabricated & fixing Powder coated (thickness of powder coating minimum 60 micron) anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge.
Supply only 6mm thick aluminium composit panel sheet as in aluminium doors and partitions complete all as specified and directed. Note :- Cost of fixing of aluminium composit panel sheet shall be deemed included in the unit rates under respective items.
Supply only 5.5mm thick sheet glass ordinary quality, cut to size as required at site, complete all as specified and directed. (Cost of fixing of glass shall be deemed included in the unit rates under respective items.)
Supply only stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm, complete all as specified and directed. (Note: cost of fixing of wire cloth shall be deemed included in the unit rates under respective items.)
S&F in renewal of door closer hydraulically regulated, aluminium die cast body, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm width and weight between 61 to 80 Kg and fixed, complete all as specified and directed.
S&F in renewal of mortice lock, made of brass, vertical type, size 100 mm, mild steel, 4 levers complete all as specified and directed.
S & F of framed work as in doors or gates of angles or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with including either hooks and hinges or steel hanging door fittings (excluding of steel sheeting or other covering running rails and guides) and hanging also fastening and fixing, conforming to Fe-290 Grade-E-165, complete all as specified and directed.
S&F mild steel framed work as in grills, grating etc. with end of bars shouldered and/or riveted, or forged into spikes: framed guard bars: barred iron doors: ladders: cages, frame balusters: walk ways: railing: frame work of water tanks and similar works conforming to Fe-290 Grade-E-165, complete all as specified and directed.
S&F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240, complete all as specified and directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410W, Grade-E-250, quality 'A' complete all as specified and directed.
S & F for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 5cm but not exceeding 10cm long and dia of neck exceeding 16mm but n.exc 20mm complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, wall cladding etc, fixed to iron/wooden members with self drilling zincoulium coated metal screws having cap with rubber and metal washers, complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, wall cladding etc, fixed to iron/wooden members with self drilling zincoulium coated metal screws having cap with rubber and metal washers, complete all as specified and directed.
S&F of wire netting of galvanised steel wire 1.40 mm dia fixed with tinned tacks of wire staples, size of mesh 20 mm, complete all as specified and directed.
S&F in renewal of wire netting of galvanised steel wire 1.40 mm dia fixed with tinned tacks of wire staples, size of mesh 20 mm, complete all as specified and directed.
S&F peg set of six hooks of stainless steel, design as approved by GE complete all as directed.
Dismantalling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
S&F of micro perforated square edge and attractive finish mineral fibre (sand micro of nominal size 595x595x15 mm thick having building attribute as in false ceiling, fixed with and including grid of size 600x600mm having main frame of aluminium T of size 35x25x0.70 mm thick, cross aluminium T of size 25x35x0.70mm thick and wall angle of size 25x25x0.7 mm thick, the grid shall be suitable for mineral fibre tiles and hanging from soffits of existing RCC roof slab with using connecting/levelling clips, complete all as per manufacturer’s instructions, all as specified and directed.
S&F in renewal of stainless steel tubular curtain rods, 25 mm dia, with fixing brackets and one pair of decorative end caps etc, complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8 type D-2, using 40 mm graded crushed stone aggregate, as in sub base of floors, etc., finished surface even & fair to receive floor finishes/ screed complete all as specified and directed.
M&L chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment, laid over and including 15 mm thick screed in CM 1:6, complete all as specified and directed.
M&L precast (factory casted) cement concrete kerb stone casted in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate with plain or interlocking joints (as directed) including weathering, slightly rounded or chamfered angles, placing in position, set and jointed in CM 1:4, complete all as specified and directed.
M&L for 25mm thick plain cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in flooring /sub base finished surface even & fair to receive floor finishes/ screed complete all as specified and directed.
M&L for light coloured vitrified tiles, 10mm thick (square/ rectangular) area of each tile not exceeding 0.36 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for light coloured vitrified tiles, 10mm thick (square/ rectangular) area of each tile not exceeding 0.36 Sqm, fixed on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick on stone masonry surfaces or other than fair faces of brick work in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick on stone masonry surfaces or other than fair faces of brick work in cement mortar 1:4, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for preparing new steel surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over & including one coat of red oxide zinc chrome primer, complete all as specified and directed.
M&L for preparing old steel surfaces exceeding 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L applying 2 coats of synthetic enamel paint over and including a coat of pink primer on wooden surfaces, exceeding 10 cm in width or girth, incl preparation of the new surfaces complete all as specified and directed.
M&L for applying two coats of cement based paint on newly plastered surfaces of walls over and including a coat of white wash & including preparation of surfaces, complete all as specified and directed.
M&L for complete removal of existing treatment from previously treated plastered/unplastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of suitable primer, complete all as specified and directed.
M&L for complete removal of existing treatment from previously treated plastered/unplastered surfaces of walls and applying two coats of cement based paint over and including a coat of white wash, complete all as specified and directed.
M&L for applying three coats of white wash on walls including preparation of new or previously untreated surfaces, complete all as specified and directed.
Excavating in post holes (or similar holes) in any type of soil, each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm around foundation concrete as ordered, watering and removing surplus soil to a distance not exceeding 50 m and making good surface, complete all as specified and directed.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings or for laying cables etc not exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in excavated soil including spreading, levelling, watering and well ramming in layers not exc 25 Cm, complete all as specified and directed.
Removing excavated materials (soil) not exc 50 m distance and depositing where directed at a level not exc 1.5 m above the starting point, complete all as specified and directed.
M&L hardcore (broken stone) of gauge not exc 63 mm, deposited spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for reuse or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Dismantling unserviceable main switch/DBs incl wooden board and deposit to MES store yard including making good disturbed surface of wall complete all as specified and directed.
Taking down sub main wiring /XLPE cable of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surface, complete all as specified and directed.
M&L for Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface including providing wooden rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces, complete all as specified and directed for the following: - One light/ceiling fan/exhaust fan/bell buzzer point controlled by one, one way switch of 5/6 Amps. Note :- Cutting chases (if required) and making good to match with the adjoining surface shall be included in the unit quoted rate.
All as per item No 75.00 (here-in-before) but one 5 Pin, 5/6 amps socket outlet point on independent board, controlled by one, one way 5/6 Amp switch.
All as per item No 75.00 (here-in-before) but one 5 Pin, 5/6 amps socket outlet point on same board, controlled by one, one way 5/6 Amp switch.
M&L Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable FRLS of size 2.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface for one socket outlet 15 amp on independent board including providing wooden/PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surface, complete all as specified and directed.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
Supply and fixing switch socket combination, 5/6 and 15/16 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
Supply and fixing socket outlet, 5/6 Amps, 230 volt, five pin, flush type universal, complete all as specified and directed.
S&F PVC/polycarbonate lamp holder, angular/batten type with back plate, ISI marked complete all as specified & directed.
S&F in renewal of stepped type electronic fan regulator, flush type, 230 volts AC, single pole, humming free, fixed on the existing phenolic laminated sheet, complete all as specified and directed.
S&F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 50mm, 3 terminals, complete all as specified & directed.
S&F bell push paino flush type, AC, 5 Amp, ISI marked complete all as specified & directed.
S&F in renewal of call bell, AC, 230 volts, single pole, ISI marked complete all as specified & directed.
S&F in renewal of wall mounted 18 watt LED Tube light fittings, batten type with bipin holders, powder coated steel with internally prewired, complete all as specified and directed.
S&F in renewal of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in renewal of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
M & L in renewal of street/road light GI mounting bracket made out of steel tube, medium grade, 40 mm dia (or higher size to suit the opening of the fitting) 1.50 mtr long by hydraulic pressed mechine bend to require arc shape and fixed to pole with 02 Nos MS flat iron clamps of suitable size fixed with bolts, nuts and washers including drilling holes and grouting with the same for fixing bolts as required & incl duly painted with two coat of aluminum paint over a coat of aluminum red oxide primer and fixing with lights fittings on the existing old street light poles complete all as specified and directed. Note :- Cost of Necessary tools and plants such as ladders, hydra for renewal of mounting brackets, light fittings, nuts, bolts etc shall be deemed to be included in the unit rate quoted.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volt, 10 KA 'C' curve including all accessories, complete all as specified and directed.
S&F MCB, 6 to 32 Amps, Single Pole & Neutral, 240 Volt, 10 KA 'C' curve including all accessories, complete all as specified and directed.
S & F MCB TPN 63 Amps, 415 volts, four pole, C-curve, rupturing capacity 16KA conforming to IS-8828-1996, IEC-60898, complete, all as specified & directed by Engineer-in- charge.
S & F factory made MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, IP-43-IK09 protection grade, earth bar and Din rail, 415 Volts TPN with 4 ways, Double door, complete all as specified and directed. Note for items of MCB DB - (1) The unit rate includes for cutting the brick/stone walls to accommodate DB to make flush to wall. (2) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface.
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 240 Volts SPN with 8 ways, Double door, complete all as specified and directed.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multistranded copper conductor cable of size 6 Sqmm LT, 1100 volts grade, drawn through and including 20 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 6 sqmm single core multistranded FRLS copper conductor cable green colour as earth continuity conductor, complete all as specified & as directed. NOTE for items of submain wiring:- Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length. Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the PVC conduit.
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized iron earth wire of 4 dia by means of bolts, nuts, check nuts and washers of galvanized iron including 15 mm bore light grade GI tubing for protection of earth wire, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling and taking out old earthing complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 5 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire and earth wire upto 7.5 m. Any variation below or above shall be measured and paid for separately under relevant item of this Sch ‘A’.
Supplying, laying, jointing testing and commisioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade of cross-sectional area 25 Sqmm, 3.5 core, laid in trenches / ducts / encased in GI pipe / fixed to pole/wall, complete all as specified and directed.
Supplying, laying, jointing testing and commisioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade of cross-sectional area 16 Sqmm, 2 core, laid in trenches / ducts / encased in GI pipe / fixed to pole/wall, complete all as specified and directed.
M&L dry clean Sand filling in trenches around underground cables for earth cushion, complete all as specified and directed. Note: - Depth of sand shall be measured after punning.
Supplying and laying pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), laid flat adjoining each other as in protection to UG cables, complete all as specified and directed.
Cutting of road / hardstanding upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable protection pipe line, making good the disturbed portion so as to match existing finishing or with PCC 1:2:4 type B1 complete all as specified and directed.
M&L in renewal of 40 mm bore Steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
L P Singh and Co.
K B Enterprises
Aditya Enterprises
ANNAPURNA ENTERPRISES
M/S MOHINI ENTERPRISES
SINGH ENTERPRISES
M/s Prem Associates
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .