Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.1 Cr+₹48,951.45 (0.44%)Rejected-Finance | ₹1.1 Cr+₹48,951.45 (0.44%) | L2 | Rejected-Finance L2 |
Tender Value
₹1.2 Cr
EMD Value
₹50,000
Closing Date
2 Aug 2023, 3:00 pmClosed
Superintending Engineer
O/o of Superintending Engineer PHC KWA TVPM
JJM CWSS to Peringamala Grama Panchayath in TVPM district Supply Erection Testing and Commissioning of Raw Water Pump Set in Well Cum Pump House at Thampuranvachudakayam And Clear water pump set at WTP at Ayiravallykunnu
2023_KWA_590480_1
102/2023-24/KWA/PHC/D3/TV
Open Tender
Civil Works - Water Works
Item Rate
180 days
Peringamala
Pls refer NIT
7 documents required · 7 mandatory
₹6,508
₹50,000
Yes
23 Sept 2023
26 Jul 2023
3 Aug 2023
26 Jul 2023
2 Aug 2023
26 Jul 2023
26 Jul 2023 - 2 Aug 2023
Amount
1-SUPPLY,ERECTION,TESTING ,COMMISSIONING OF VT PUMP SETS AT RAW WATER PUMP HOUSE, THAMPURANVECHUDAKAYAM
OD123999/2022-2023:Design, testing, Supply, erection, trial run and commissioning of Vertical Turbine Pumpsets (with stand by) of approx. 60.386lps against actual head (78m tentative) and having 1500 rpm sync. Speed, Bronze LTB2 Impeller, SS 316 shaft, cast iron casing, Bronze LTB2 neck ring, SS 410 sleeve, squirrel case EF2 motor with a complete integrated soft starter panel capable of operating the motor having a protection level of IP 40 or more with integrated bypass contactor in the panel and motor protection relay having parameters as per IE rules, with a power control MCCB and line power contactor, and the starting current shall be 2.5 – 3.5 times the normal full load current of motor with Ammeter, voltmeter and phase indicators, space heaters, floor monitory type and having an insulation level of 100 V (the standard of starter is to be I.E.C 60947-4-2) control switches, capacitors, pressure gauge etc satisfy the requirements and including the cost of internal wiring with suitable copper cable, valve( PN1.6), specials etc and fixing the flow meter to pump sets (motor, capacity, type etc should be specified.) pipes and specials required for the interconnection works with the existing pumping main suction and delivery part of pumps and provide the electrical and mechanical installation as per the KSEB, and KSEI specification and standards (All items required for the commissioning should be supplied and erected/fixed and initial and final approval obtained from KSEI and got energized from KSEB). The pump and motor supplied are to be from Kerala Water Authority short listed manufactures and should be in accordance with relevant IS Specification. (Rate vide proceedings of CE (Projects) No.10636/AE 15/2022/KWA dt. 29.03.2023). The efficiency of pumpset will not be less than 75% with replaceable warranty of minimum period of 2 years. (The actual head to be arrived by the contractor)
OD124000/2022-2023:Supply of flow meters and accessories of size 300mm-Supplying an Electromagnetic Flow meter confirming to protection level of IP-68 for Flow sensor and IP 67 for transmitter and having an accuracy level of 0.5% with LED /LCD display unit.The flow meter should have the housing (Flow sensor) to be made of ISS304/Carbon steel with anticorrossive protection and inside liner to be made up to Hard Rubber/neoprene all confirming to drinking water standads.The flow meter should be coupled with HART for data acquisition and transfer with provision for wirless transfer through GSM.The manufacturer should have the callibration standards as per ISO 17025 and the product shall have sufficient warranty provisions vide circular no KWA/HO/SP-4014/2012/Flowmeter and Soft starter dt 5/9/2012
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
100.37.9.1:In situ fabrication of M.S. pipes of size 300mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.9.2:Fabricating M.S. flanges of diameter 300mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.9.3:Cutting 300mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.9.4:Welding 300mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.9.5:Grinding cut and weld edges of 300mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
OD124014/2022-2023:upply of 1100 Voltage grade3.5 core 300 sq mm AYFY cable 3.5 core 300 Sq mm additional cable(2 run) beyond the initial supply of 10m
Supply,Erection,Testing and Commissioning of Clear Water Pump Set for proposed 10.6 OHSR at Ayiravallykunnu
OD48037/2023-2024:Supplying and fitting 250 mm an Electro-Magnetic Flow Meter confirming to protection level of IP-68 for flow sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit. The flow meter should have the (flow sensor) to be made of SS 304/Carbon Steel with anti corrosive protection and inside liner to be made up of Hard rubber/neoprene all confirming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions and including insulation charges with required fittings etc complete.
OD48206/2023-2024:Design, testing, supply, erection and commissioning of Split case centrifugal pump set with prime mover of required capacity to discharge 7.5lps on 18 hours(avg) pumping against actual head with all electrical and mechanical accessories like starter, Panel board, cable, capacitors, Non return valves (with ISI mark), sluice valve (PN 1.6), pressure gauge, required pipe and specials etc. complete upto the outside of the pump house including interconnection works as per the KSEB, and KSEI specification and standards (All items required for the commissioning should be supplied and erected/fixed and obtain initial and final approval from KSEI and got energized from KSEB). The materials of pump should confirm to the relevant IS and pump to be supplied should be strictly according to the relevant IS and Kerala Water Authority Approved manufacturer.(The actual head to be arrived by the contractor)<br> (Rates as per CE (Projects) KWA Proceedings no. 10636/AE 15/2022/KWA dated 29.03.2023)
OD48205/2023-2024:Supply of flow meters and accessories of size 225mm-Supplying an Electromagnetic Flow meter confirming to protection level of IP-68 for Flow sensor and IP 67 for transmitter and having an accuracy level of 0.5% with LED /LCD display unit.The flow meter should have the housing (Flow sensor) to be madeof ISS304/Carbon steel with anticorrossive protection and inside liner to be made up to Hard Rubber/neoprene all confirming to drinking water standads.The flow meter should be coupled with HART for data acquisition and transfer with provision for wirless transfer through GSM.The manufacturer should have the callibration standards as per ISO 17025 and the product shall have sufficient warranty provisions vide circular no KWA/HO/SP-4014/2012/Flowmeter and Soft starter dt 5/9/2012
THANKANPPAN CONTRACTOR
Bidder Name
THANKANPPAN CONTRACTOR
Renjith M
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_873764.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .