Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹12.1 L Quoted ₹12.4 L | L1 | Accepted-AOC Contract Awarded being lowest bidder. |
| 2 | L2₹12.9 L+₹54,626.50 (4.41%)Rejected-AOC 108 MARUTI COMPLEX NEAR DIGVIJAY TIN FACTORY MILE STONE BUILDING KV ROAD JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | ₹12.9 L+₹54,626.50 (4.41%) | L2 | Rejected-AOC Rejected due to Higher amount quoted. |
| 3 | L3₹14.0 L+₹1.6 L (13.0%)Rejected-AOC | ₹14.0 L+₹1.6 L (13.0%) | L3 | Rejected-AOC Rejected due to Higher amount quoted. |
| 4 | L4₹15.0 L+₹2.6 L (21.1%)Rejected-AOC PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | ₹15.0 L+₹2.6 L (21.1%) | L4 | Rejected-AOC Rejected due to Higher amount quoted. |
| 5 | L5₹22.0 L+₹9.6 L (77.2%)Rejected-AOC | ₹22.0 L+₹9.6 L (77.2%) | L5 | Rejected-AOC Rejected due to Higher amount quoted. |
| Sl No | Description | Qty | Unit | Rameshwar Enterprise L2 | SURESH ELECTRICALS L1 | ABR Trading Co L3 | OM ELECTRICAL ENERGY L5 | M/s Balaji Enterprise L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismandling of existing unserviceable cross arms of any description and in any position complete all as specified and directed by Engr - in - Charge. | 6.8 | Qtl | 600 ₹4,080 | 100 ₹680 Lowest | 500 ₹3,400 | 700 ₹4,760 | 1,400 ₹9,520 |
| 2.00 | Dismantling Insulators like 11 KV HT, Pin type, Disc type and loop insulators from existing Electrical Poles/ 2 pole/ 4 pole structure of any description and any size complete all as specified and as directed. | 9 | Each | 40 ₹360 Lowest | 50 ₹450 | 50 ₹450 | 400 ₹3,600 | 150 ₹1,350 |
| 3.00 | Dismantling complete GOD all as specified and directed by engr-in- charge | 4 | Each | 400 ₹1,600 Lowest | 1,100 ₹4,400 | 1,500 ₹6,000 | 7,000 ₹28,000 | 2,200 ₹8,800 |
| 4.00 | Supply and fix cable jointing kit for 11 KV grade cable for indoor termination, cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE , armoured, Al conductor cable of size 50 Sqmm to 95 Sqmm | 5 | Each | 12,000 ₹60,000 | 10,000 ₹50,000 | 5,500 ₹27,500 Lowest | 10,000 ₹50,000 | 7,500 ₹37,500 |
| 5.00 | Dismantling of ACSR Conductor of any size | 2.5 | Qtl | 1,000 ₹2,500 | 300 ₹750 Lowest | 500 ₹1,250 | 900 ₹2,250 | 1,600 ₹4,000 |
| 6.00 | Dismandling of existing unserviceable concret poles/ struts of any Size and in any position complete all as specified and directed by Engr - in - Charge. | 4 | Each | 500 ₹2,000 Lowest | 850 ₹3,400 | 500 ₹2,000 Lowest | 1,000 ₹4,000 | 1,400 ₹5,600 |
| 7.00 | (a) Supply, install, testing and commissioning of Ring Main Unit 11 KV, 630A, 21 KA for 3 sec, Outdoor Manual Non-Extensible RMU 4 way RMU with 2 Nos. Incoming LBS and 2 Nos outgoing VCB (CVV) safeplus compact switchgear including foundation work all as specified and directed by Engr-in-charge . | 1 | Each Job | 8,80,000 ₹8,80,000 | 7,77,777 ₹7,77,777 Lowest | 9,77,323 ₹9,77,323 | 15,61,252 ₹15,61,252 | 8,65,000 ₹8,65,000 |
| 7.01(b) STANDARD AND MECHANICAL DATA: Metal enclosed switchgear: IEC 62271-200, General purpose switches: IEC 60265-1 Disconnectors and earthing switches : IEC 62271-102 Switch fuse combination: IEC 62271-105 Circuit breakers: IEC 62271-100 Common cluases: IEC 60694 Pressure of SF6 gas : 1.4 bar at 20°C Cable bushings: DIN 47636 Temprature class: -25°C - +40°C outdoor Degree of protection: SF6 tank-IP67, Front cover- IP 2X, Cable cover- IP 3X, Enclosure- IP 54 Busbar: 240 sqmm Cu earth bar (external): 120 sqmm Cu - Bolt dimension: M10 Thickness of Stainless steel tank: 3 mm Colours: front cover- RAL 7035, Side and cable cover- RAL 7035, Enclosure IS 632 (c) ELECTRICAL DATA - 12 KV- 28 KV- 1 min: Nominal voltage: 11 KV Rated frequency: 50 Hz Rated current bus bar : 630A Rated current cable switch disconnector : 630A Short time withstand current: Cable switch disconnectorwith interface C (400-bolt) bushing: 21 kArms 3 sec, Vacuum circuit breaker with interface C (400-bolt) bushing: 21 kArms 3 sec Rated current for transformer T-off: 630A Impulse withstand voltage: To earth and between phases: 75 kv Insulation level: Power frequency 1 min: 28 kv | ||||||||
| 7.02(d) C - Load Break Switch: safeplus C is a cable switch module with a three-position load break switch and earthing switch, busbars, interlocking and earth bar. SafePlus type C: Cable switch 12 kv, 630A Cable cover standard Cable bushings interface C (400 bolted), 630A, standard Capacitive voltage indication fixed type VPIS 9-15 kv Cable support bars, standard for 1-way unit (e) V- Vacuum Circuit Breaker : SafePlus V is a Vacuum Circuit Breaker module with vacuum circuit breaker, three position isolator/ earthing switch, busbars, interlocking, earthbar and stored spring energy mech (EL- mech). SafePlus type V: Vacuum circuit breaker 12 kv, 630A Cable cover standard Self-powered over current and earth fault protection relay with RS485 port type ADR241S Capacitive voltage indication fixed type VPIS 9-15 kv Cable bushing interface C (400 bolted), 630A Cable support bars, standard for 1 way unit Ring core current transformer type 100/1 A, 2.5 VA, 5P10 | ||||||||
| 8.00 | Supply, install and testing for maintenance free chemical earthing of dual pipe technology of 3 mtr long with outer pipe dia 88 mm and inner pipe dia 48 mm, the pipes are properly galvanised for 80-120 micron and wall thickness of inner pipe 3 mm and 2 mm of outer pipe. There is additional copper coating on outer surface. There should be terminal for connection of 75 x 6 mm with 2 holes of 14 mm dia. Fast Electrode is duly filled with highly conductive material with sealing at boath ends with lead terminal of 75 x 6 mm at top along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any international accredited and BIS accredited laborartory. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be tested reffering to protocol IS 1350 and IEC 62321/111/54/CDV. The ph value of compound should be 7-8. The content of mercury and hexa chromium should be below detection level. The electrode should be tested for salt spray test as per BIS 117-09 for corrosion for minimum 500 Hrs. The electrode should be duly tested and certified by CPRI Govt of India for a min short circuit current of 42 k amps for 1 Sec with initial pick of 8.2 K amp connected to copper strip 20 x 3 mm thick earth strip by means of bolts, nuts, check nuts and washers of copper with 40 mm dia medium grade GI pipe as a protection up to 7.5 mtr long and RCC pit with cover complete and connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and as directed. Model FE 88, 3 Mtr (copper) of Make Fast Electrode or its equivalant specifications appoved make by Garrison Engineer. | 6 | Each | 14,500 ₹87,000 Lowest | 25,000 ₹1,50,000 | 15,000 ₹90,000 | 15,500 ₹93,000 | 39,000 ₹2,34,000 |
Tender Value
Refer Docs
EMD Value
₹28,500
Closing Date
2 Sept 2025, 6:00 pmClosed
CWE AHMEDABAD
CWE Ahmedabad Hanuman Camp Shahibaug Ahmedabad PIN-380003
SPECIAL REPAIR/REPLACEMENT TO CONVERT 04 POLE STRUCTURE TO RMU (RING MAIN UNIT) INCLUDING OTHER ALLIED WORKS AT MIL STN JAMNAGAR
2025_MES_724697_1
87424/E8
Open Tender
Civil Works
Item Rate
120 days
ARMY AREA JAMNAGAR
AS per Tender Documents
5 documents required · 5 mandatory
₹500
GE (A) JAMNAGAR
₹28,500
Yes
13 Dec 2025
6 Aug 2025
9 Sept 2025
6 Aug 2025
2 Sept 2025
21 Aug 2025
6 Aug 2025 - 20 Aug 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .