Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹23.7 L
EMD Value
₹50,000
Closing Date
22 Feb 2025, 5:00 pmClosed
Executive Engineer
Office of the executive engineer LID EW Division Wayanad DP Kalpetta
LAC-ADS-MLA - ADF - 2024-25 - Street lights (Low mast) at 13 Locations - Edavaka GP
2025_LSGD_738291_25
D2-2478/24(8)
Open Tender
Electrical Works
Item Rate
90 days
Kalpetta
Please refer in tender documents
7 documents required · 7 mandatory
₹2,760
Yes
₹50,000
Yes
25 Apr 2025
15 Feb 2025
24 Feb 2025
15 Feb 2025
22 Feb 2025
15 Feb 2025
Amount
ELECTRIFICATION
90.15.1.2:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 155 mm bottom diameter thickness 3mm base plate dimensions of 250x250x16 mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos fixed in existing RCC foundation adn junction box etc, complet 9 Meters
90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
OD119832/2024-2025:Supply and installation of 40A, 6 Way Bakelite Connector strip in existing panel/box with all accessories.
OD119779/2024-2025:Supply & laying of one No. PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.6 core 1.5 sq mm.
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD119841/2024-2025:Supplying and Fixing DIN rail inside the existing MCB DB/ Panel/Meter board etc.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
OD110747/2024-2025:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in position and binding all complete.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
OD110752/2024-2025:Supply and provide 6Sqmm Aluminum conductor 2core weather proof service wire drawn through existing PVC conduit including giving connection as required.
OD110751/2024-2025:Supply and provide Nylon stay wire for supporting weatherproof service wire including binding the WP wire using Alu. wire as required.
OD110758/2024-2025:Supply and fixing of 32A, Bakelite HRC fuse with HRC fuse link
OD110759/2024-2025:Supplying and fixing 32A, 2 way Bakelite Neutral link mounted on DMC/SMC base with connection, in the existing meter board
OD110749/2024-2025:Supply and fixing of 1P+N,40KA,1 module surge protector on existing mcb DB/enclosure and giving connection as required. (Schneider A9L40500 or equivalent).
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
OD110750/2024-2025:Supplying and fixing 32A 2Pole AC1 Power contactor in Din bar complete with connections, testing and commissioning, etc. as required.
OD110753/2024-2025:Supplying and fixing 24Hours Timer switch for operating ON-OFF function in the existing MCB DB/enclosure complete with connections, testing and commissioning, etc. as required. (L&T-j6107b204) or equivalent.
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD110755/2024-2025:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipments including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 4.00Sqmm single run
OD110754/2024-2025:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/equipment including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 1.5Sqmm single run
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
OD110748/2024-2025:Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
OD110756/2024-2025:Supply and providing 25x6mm brass nut and bolt etc. as required
OD110757/2024-2025:Supply and providing 25x3mm brass nut and bolt etc. as required
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
OD110760/2024-2025:Fabrication, supply, and conveyance and installation of name board by using granite stone with inscriptions such as scheme and the required names as per the direction from panchayath/local body, etc. on suitable size angle iron frame cut and welded to shape including painting with two coats of synthetic enamel paint over a coat of Zinc chromate primer and fixing the whole to the high mast/Low mast pole by using required bolt and nuts as required. (size not less than 60x45cm)
Bidder Name
BASIL MATHEW
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .