Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹77.6 LAccepted-AOC VILLAGE PO RAJAIN TEHSIL BHATTIYAT DISTT CHAMBA HP | L-1 | Accepted-AOC Accepted | |
| 2 | L-2₹1.1 Cr+₹4.9 L (4.68%)Rejected-AOC | L-2 | Rejected-AOC Rejected | |
| 3 | L-3₹1.4 Cr+₹30.6 L (29.1%)Rejected-AOC HOSPITAL ROAD OPP VIPUL GAS AGENCY SOLAN HP 173212 | SOLAN | SOLAN | HIMACHAL PRADESH | 173212 | L-3 | Rejected-AOC Rejected | |
| 4 | Rejected-Technical | - | Rejected-Technical Reject |
Tender Value
₹70.4 L
EMD Value
₹1.0 L
Closing Date
14 Aug 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE Rampur
JSD Rampur
imp. of LWSS Nogli khad to Shingla Uru
2020_HPIPH_39657_1
EE-JSD-RMP-E-Ten/21-3439-3489 dt 7.8.20
Open Tender
Civil Works
Item Rate
365 days
Rampur
Please refer Tender documents.
7 documents required · 7 mandatory
₹800
EE Rampur
₹1.0 L
25 Nov 2021
7 Aug 2020
17 Aug 2020
7 Aug 2020
14 Aug 2020
7 Aug 2020
120 days
Amount
Cutting in earth work in all classification of earth work such as pick work, jumper work, saturated soil, blasting soft/ hard rock or chiselling soft/ hard rock where blasting is prohibited in all lifts including trimming and dressing of sides levelling of beds to correct grades including shoring, strutting, planking, timbering where ever required, stacking the serviceable/ unserviceable materials/soil separately complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Excavation in earth work and disposal of all excavated earth up to all leads and lifts, disposed earth to be levelled neatly dressed as per direction and to the entire satisfaction of the Engineer-in-Charge.
Excavation in foundation trenches etc.(for pipes & pits upto all depth) in earth work in all classification of earth work such as pick work, jumper work, saturated soil , blasting soft/hard rock or chiselling soft/ hard rock including wedging out of a rock where blasting is prohibited in all lifts including trimming and dressing of sides levelling of beds to correct grades including shoring, strutting, planking, timbering and dewatering where ever required, stacking the serviceable/unserviceable materials/soil separately and after laying and jointing of pipes, returning the usable soil in trenches in 15 CM layers including consolidation of each deposited layers by ramming and watering and then dispositng of all surplus excavated soil, useable materials as directed within all leads/lifts including restoration of metalled surfaces to its original condition and including cost of diversion for traffic night signals, fixing caution boards, crossing over trenches for access to houses fencing etc. complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Providing and laying cement concrete 1:6:12 ( 1 cement : 6 sand : 12 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete in all respect with in all leads & lifts and as per the direction & to the entire satisfaction of the Engineer-in-Charge.
Providing and laying cement concrete 1:5:10 ( 1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete in all respect with in all leads & lifts and as per the direction & to the entire satisfaction of the Engineer-in-Charge.
Providing and laying cement concrete 1:5:10 ( 1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) with 15 % plum and curing complete excluding cost of form work in foundation and plinth complete in all respect with in all leads & lifts and as per the direction & to the entire satisfaction of the Engineer-in-Charge.
Providing and laying cement concrete 1:4:8(1Cement: 4Sand: 8Graded stone agg.40mm nominal size)& curing complete excluding cost of form work in foundation and plinth as per direction & to the entire satisfaction of the Engineer-in-Charge with in all leads and lifts .
Providing and laying cement concrete 1:3:6(1Cement:3Sand:6Graded stone agg.40mm nominal size)& curing complete excluding cost of form work in foundation and plinth as per direction & to the entire satisfaction of the Engineer-in-Charge with in all leads and lifts .
Providing and laying cement concrete 1 : 2 : 4 ( 1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced cement concrete work in :-
In suspended floor roofs ,landing and shelves and their support.balconies , beams,girders, bressumers and contilever up to floor two level with in all leads and lifts.
Providing and laying cement concrete 1 : 1.5 :3(1 cement :1.5 sand :3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcemnt for reinforced concrete work complete in all respect with in all leads and lifts as per the direction and to the entire satisfaction of Engineer-in-Charge .
Foundation and plinth complete as per the direction and to the entire satisfaction of the Engineer-in-Charge.
Walls (any thickness but not less than 0.10m thickness) attached pillaster, buttresses, plinth & string courses etc from top of foundaation level upto floor two level as per the direction & to the entire satisfaction of the Engineer-in-Charge.
In lintels, Beams, girders etc.
Arches upto floor two level
Prov.form work with steel plates 3.15mm thick welded with angle iron frame 30 x 30 x 5mm so as to give a fair finish including centring, shuttering,strutting & propping etc. with wooden battens and ballies, height of propping & centering below supporting floor to ceiling not exceeding 4mtr.& removal of same for insitu rainforced concrete and plain concrete work complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge :-
Flat surfaces such as soffits & suspended floors, roofs, landing and the like. Floor etc. upto 200mm in thickness.
Vertical surfaces such as walls ( any thickness ) partition and the like including attached pillasters buttresses, plinth and string courses and the like.
Edges of slab under 20 cm wide.
Prov.form work of ordinary timber planking so as to give a rough finish including centering shuttering struting and propping etc. height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs & removal of the same for instu reinforced and plain conctrete work in:-
Arches beond 6.00 mtr span
Providing in RCC work smooth finishing of the exposed surface with Cement mortar 1:3 (1 Cement : 3 Sand) & as per direction & to the entire satisfaction of the Engineer-in-Charge.
Providing mild steel / tor steel reinforcement for reinforced cement concrete work including bending, binding and placing in position complete upto floor two level complete in all leads and lifts and as per the direction and to the entire satisfaction of the Engineer-in-Charge. Tor Steel.
Providing & Fixing of MS manhole cover with frame 500mm dia (light duty). Total weight of frame and cover should not less than 100 Kg. complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
P/F Compound gate as per standard design i.e M.S angle iron clamps, pintal sets with pin clamps in cement concrete block (150x30x29) size complete
Constructing chamber for sluice valve, with CI surface box 100 mm top dia, 160 mm bottom dia & 180 mm deep (inside) with chained lid RCC top 1:23:4 mix(1 cement:2sand:4geaded stone aggerate 20 mm nominal size) 100 mm thick foundation concrete1:5:10 mix(1cement:5sand:10graded stone aggregate 40 mm nominal size)& inside plastering with cement mortor 1:3 (1cement:3sand)finished with a floating coat of neat cement 1/c curing complete 1000x1000x1000 mm inside size with 150 mm thick walls of RCC 1:2:4 (1 cement:2sand:4graded stone aggregate 20 mm nominal size) complete with form work & reinforcement with 6 mm bars at not exceeding 150 mm centers both ways)
Steel work welded in built up section , trusses and framed work including cutting,hoisting,fixing in postion and applying a priming coat of red lead paint.
In gratings framed guard bars,ladders, railling,brackets and similar work. & as per direction & to the entire satisfaction of the Engineer-in-Charge
1.80mt.height fencing with 2.5mt (50x50x6 mm) angle iron post ,2.50mt centre to centre with nine horizental lines and two diagonals of galvinised steel barbed wire) IS:278-1962 type-I) weighting 9.38kg per 100mt.(minimum) strained and fixed to post complete in all respect with CC 1:5:10 within all leads and lifts as per direction & to the entire satisfaction of Engineer-in-charge.
Boulder filling behind retaining wall as per direction and to the entire satisfaction of Engineer -In-Charge.
White Washing with lime on undecorated wall surface two coats to give an even shade including thoroughly brooming the surface to remove all dirt, dust, mortar dirt and other foreign matter
Laying, jointing and testing in trenches to be levelled to grade galvanised mild steel pipe light grade of following nominal diameter including fittings complete in all respect to the entire satisfaction of the Engineer-in-Charge. ( Earth work in trenches to be measured and paid for separately).
15mm nominal diameter.
20 mm nominal diameter.
25 mm nominal diameter.
32 mm nominal diameter.
40 mm nominal diameter.
50 mm nominal diameter.
65 mm nominal diameter.
100 mm nominal diameter.
Dismentalling of old GI pipe (LG) of 50 mm diameter complete within all leads & lifts and to the entire satisfaction of Engineer-in-charge(Earth work in trenches to be mesured and paid for separately
50 mm nominal diameter.
Re Laying , Jointing and Testing in trenches galvanized mild steel screwed and socked/ flanged pipes of following diameter and class tube fitting in trenches i/c carraige of pipes from sub divisional store to site of work , ( earthg work in trenches to be measured and paid for separately) complete in all respect and to the entire satisfaction of Engineer-in-charge (LR)
50 mm nominal diameter.
Providing & fixing full way valve with wheel of following diameter complete within all leads and lifts.
15 mm nominal diameter.
20 mm nominal diameter.
25 mm nominal diameter.
32 mm nominal diameter.
40 mm nominal diameter.
50 mm nominal diameter.
65 mm nominal diameter.
Providing & fixing CI Sluice valve with hand wheel of following diameter complete within all leads and lifts.
100 mm nominal diameter.
PUMPING MACHINERY
Providing Supplying & errection, testing and commisioning with horizontal spindle/ redial split casing /side suction Multistage centrifugal pumps of recommended make, such as Mathar platt/BS & BE ,KSB/ Kirloskar BE/Jyoti /Crompton etc. as per IS -1520-1980 or latest addition suitable for lifting clear water for under mentioned characteristics . the pump hall be fitted with bronze inmpeller , sharp soft of stainless steel grade 45 C-8 discharge casing and all stage casing above 400 mtr shall be cast steel balancing /counter balancing disk of chrome steel , tie bolts EN-8 . rest of item shall be as per manufacturer standard suitable for duty condition . MS fabricated base plate shall be of suitable channel section as recommended by the manufacturer of the pump . The pump set shall be coupled directely RPM squrrel cage SPDP induction motor of standard make such as kriloskar /crompton /GEC suitable for 415 (#) 10% volts 50 cycles /second three phase AC electric supply . The power of electric motor should be at least 10% in excess of the maximum power required by the pumps in the operating range of (+) 10% and (-) 15% of the duty point head . The motor shall be as per IS -325-1978 with upto date ammendments and read with IS 900-1972 . it should include cost of bearing , nuts bolts and painting etc. and should meat the following requirements
2 set ( One working and one for stand by)
A) SITE CONDITIONS i) Location of site= Near Nogli ii) Turbidity (if any) 50PPM iii) altitude of instalation above MSL= iv) Characterstic of water= clear water x). Temprature= 32-35.4 C
B PUMP OPERATING CONDITIONS i). Discharge = 13.362 LPS per sec ii). Total dynamic head in Mtrs= 516.78 Mtrs iii). Static head/ Discharge head= 499.70 Mtrs iv). LWL in sump well.= 1070.50 v). Pump shaft level= 1070.50 vi). level at discharge point= 1570.20 vii). suction lift= positive suction viii). pumping hours.= 8 Hours viii). Length of R/Main= 1680 Mtrs viii). Dia of R/Main= 150mm
Prov. & fixing ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen / Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.( Each pannel board comprising below mention accessories)
Motor protection oil circuit breaker400 Amp. of kilburn/ L&T/MEI/ GEC make and suitable capacity on incoming feeder with initial oil filling with neutral linked under voltage release as per IS-2516-1985 with up to date ammendments suitable for offered motor i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
OJSVI VIJAY BHANDARI
HYDRAULIC ENGINEERING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .