| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.0 CrAccepted-AOC | ₹4.0 Cr | 1 | Accepted-AOC L1 BIDDER |
| 2 | 2₹4.3 Cr+₹26.2 L (6.52%)Rejected-AOC | ₹4.3 Cr+₹26.2 L (6.52%) | 2 | Rejected-AOC OTHER THAN L1 BIDDER |
Tender Value
₹3.3 Cr
EMD Value
₹4.0 L
Closing Date
12 Nov 2022, 6:00 pmClosed
Chief Engineer Shillong Zone
HQ Chief Engineer Shillong Zone Spread Eagle Falls Shillong 793001
PROVN OF SINGLE LIVING OFFICER ACCN AT MIL STATION AGARTALA UNDER AGE(I) AGARTALA
2022_MES_546602_2
CESZ/AGR/ /OF 2022-23
Open Tender
Civil Works
Lump-sum
365 days
As per tender
As per NIT
2 documents required · 2 mandatory
₹2,000
Yes
AGE (I) Agartala
₹4.0 L
Yes
6 Feb 2023
17 Oct 2022
14 Nov 2022
17 Oct 2022
12 Nov 2022
31 Oct 2022
Amount
NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Lumpsum price workedout by the tenderer for BUILDING & STRUCTURE WORKS as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the bidder/ tenderer for SITE CLEARANCE, SITE DEVELOPMENT, EXCAVATION AND EARTH WORK as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the bidder/ tenderer for INTERNAL Water Supply as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIFICATION as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the bidder/ tenderer for ROADS/CULVERT/ PATH & HARD STANDING as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the bidder/ tenderer for COMPOUND WALL/SECURITY FENCING/GATE as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule 'A' Part-X.
Sch 'A' Sec-XI (Miscellaneous Items)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 signifies this fact only.
S&F of brass chromium plated health faucet with health faucet tube of 1.2 mtr long and standered accessories etc. suitable for 15mm bore pipe for WC all as specified and directed by Engr-in-Charge
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one light/fan point controlled by one, one way switch complete all as specified and directed by Engr-in-Charge
M & L for concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One socket outlet point 6 A on Same board complete all as specified and directed by Engr-in-Charge
M & L for concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One socket outlet point 6 A on independent board complete all as specified and directed by Engr-in-Charge
M & L for concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One Bell point controlled by one,one way bell push switch all as specified and directed by Engr-in-Charge
M & L for Concealed Point wiring with 4 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 4 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for for one 16 Amp socket outlet on independent board. all as specified and directed by Engr-in-Charge
M&L sub main wiring (concealed type) single core FRLSH PVC insulated unsheathed cable, 1100 volts, grade having multi stranded copper conductor of 6 sqmm nominal cross sectional area each drawn into and all accessories including one No single core 6 sqmm copper conductor for earth continuity conductor connected to earth dolly complete all as specified & as directed by Engr-in-Charge. (Note - Two run single core cable, One run of earth conductor and one run of PVC conduit shall be measured as a unit length.)
M & L for Sub main Wiring with two run of 6.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 6.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified & as directed by Engr-in-Charge. (Note - Two run single core cable, One run of earth conductor and one run of PVC conduit shall be measured as a unit length.)
Supply and fix epoxy powder coated Distribution Board, double door SPN 10 way for MCBs with common bus-bar at incoming end of outgoing MCBs grouted/ flush to wall complete all as specified and as directed by Engr-in-Charge.
S & F or Raised pavement marker of CAT EYE size of 100 x 100 x 20 mm thick with twin shaks installed with , special hot melt bitumen adhesive ATSM D-4280 complete all as specified ad as directed by Engineer-in - charge.
S & F for round or square pipe(height of delineators 50 CM above the GL) delineators with reflective tape complete all as specified and directed
Material and labour for painting lines, dashes, Arrows, letters etc on roads pavements and the like exc 10 cm wide applying 2.5 mm thick thermoplastic road marking painting of specified shade/ colour etc., either continuous or broken lines, to the required width and length over the existing painted surface/ new bituminous surface with solvent based road marking paint (Thermoplastic road marking paint) using semi-automatic thermoplastic paint applicator machine fitted with profile shoe, glass bead dispenser, propane tank heater and profile shoe heater driven by experienced operator on road including all materials, labour, T&P and cleaning the road surface of dirt, seals, oil, gease and foreign materials etc., complete all as specified and as directed. (Note : Thermoplastic road marking paint shall be applied as per manufacturer’s instructions along with MORTH technology and speciality.)”
S & F for Convex mirror made of PC material provided with suitable MS Pipe post duly powder coated as per site requirement it should have clear and deficate mirror image valving 130 degree of viewing angle and unbreakable and stronger than glass size 1000mm complete all as specified and directed
Material and Labour for sand filling around the cable with approved quality coarse and for sand cushioning for under ground cable including spreading and puning down desired thickness compete all as specified and as directed.
Supply & fixing bricks well burnt sub class ‘B’ bricks in trenches on cable as cable protection across the length of the cable (width wise) complete all as specified and as directed.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 25 x 4mm as earthing lead connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layers complete as shown in electrical plate No. 3 of SSR Part-I all as specified and directed by Engr-in-Charge.
Earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to GI earth lead 4 mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No3 of MESschedule part-I, earth lead strip connected to indicated position including concrete pit in PCC(1:3:6, C1),Precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe"medium grade" for watering with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as specified and as directed and testing on completion.
Septic tanks, exc, in any type of soil, foundation in PCC 1:2:4, RCC M25 in walls 1:4, RCC slab covers including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame Vent shaft sludge chambers etc., complete for 25 users complete all as specified and shown on drawings No CESZ/2020/STD/01 Sheet 1/2 to 2/2 dated 28.04.2020.
M & L for Soakage wells of size 3.0x4.5m, with all fittings and fixtures complete all as specified and shown on drawing No. TD/SZ/502 sheet No 1/1
NIROJ KANTI DHAR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .