Loading…
Loading…
Tender Value
₹33.9 L
EMD Value
₹34,000
Closing Date
5 Sept 2026, 6:30 pm
Manager
CIVIL REPAIRING/ RENOVATION WORK OF RAJKOT NAGARIK SAHAKARI BANK BUILDING AT MITHAKHALI, AHMEDABAD GUJARAT.
336300
RNSB/2026-27/11
Open
Civil - All
Works
Rajkot
3 documents required · 3 mandatory
₹1,500
RAJKOT NAGARIK SAHAKARI BANK LTD
₹34,000
19 Aug 2026
19 Aug 2026
19 Aug 2026
5 Sept 2026
19 Aug 2026
Item no. Drawing Floor level Item Description Quantity Unit Rate Amount
Excavation for foundation upto 2'-6" depth including
Ground floor sorting out and stacking of useful materials and
Item No. 1 I-AH-2501-02 22.87 CBM 250
Parking Level plan disposing off the excavated stuff upto 50 Meter lead.(A)
Loose or soft soil
Filling available excavated earth (excluding rock) in
trenches in layers not exceeding 20 cm. in depth consolidating each
Item No. 2 I-AH-2501-02 disposited layer by watering. 22.87 CBM 475
Parking Level plan
Providing and laying cement concrete 1:2:4 (1- Cement :
2- Coarse sand : 4- graded stone aggregates 20 mm
Item No. 3 I-AH-2501-02 nominal size) and curing complete including cost of 25.73 Sq.M. 850
Parking Level plan
formwork in foundation and Plinth (6" thick)
Providing 20mm thick cement plaster in single coat on
existing wall of the of the dug trenches in planter area
Ground floor finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand)
Item No. 4 I-AH-2501-02 36.70 Sq.M. 290
Parking Level plan
Providing and applying chemical water proofing treatment with
cement polymer modified based waterproof compound like Tap Crete
Item No. 5 I-AH-2501-02 P151 of CICO or equivalent. On existing wall of the of the dug trenches 36.70 Sq.M. 650
Parking Level plan
in planter area.
Providing and laying VYARA Wet Cast paver blocks (Square, 200 × 200 ×
60 mm), free from cracks, cavities, or defects, laid over 50 mm thick
Item No. 6 I-AH-2501-02 kori bedding with proper slope to ensure water drainage as per site 30.19 Sq.M. 1050
Parking Level plan
Demolition of existing overground water tank as indicated in drawings,
including disposal of unserviceable materials and debris with all leads
Item No. 7 I-AH-2501-02 and lifts, using necessary equipment and transportation. 1.00 no. 2500
Parking Level plan
Repair and refurbishment on the under gound water tank with
removal of all tile/other material from the wall and floor surface
Item No. 8 I-AH-2501-02 including disposal of the debire and clearing the surface for water 20.81 Sq.M. 225
Parking Level plan
proofing treatment and plastering.
Providing and applying 2 coats of mala plaster with chemical
waterproofing treatment using cement polymer modified waterproof
compound such as Tapcrete P-151 of CICO or approved equivalent,
Ground floor including application of glass-fiber/net reinforcement in three coats on
Item No. 9 I-AH-2501-02 23.97 Sq.M. 695
Parking Level plan all wall and floor surfaces of the underground water tank, complete
with all necessary materials, equipment and labour as per site
conditions and instructions.”
Providing and laying premium quality waterproof white ceramic tiles
size (12" x 8") for under ground water tank. confirming to IS: 15622 of
approved make as specified laid on 20mm thick cement mortar 1:3 (
Item No. 10 I-AH-2501-02 cement: 3 coarse sand) including grouting the joints with white 23.97 Sq.M. 850
Parking Level plan
cement and matching pigment etc. on all wall and floor surface of
under ground water tank, considering with material with all the lead
Re-plastering of compound wall as indicated in drawings and wherever
required as per site assessment, Two-coat external plaster: 18–20 mm
total thickness, comprising 12 mm base coat (1:4 cement:sand)
Ground floor finished rough, and 6–8 mm finishing coat (1:4 or 1:5 cement:sand),
Item No. 11 I-AH-2501-02 11.61 Sq.M. 425
Parking Level plan with proper surface preparation, curing, and workmanship as specified.
including all the material and equipments required
Demolition of exiting kota stone as indicated in drawing and disposal
of unserviceable materials with all lead and lift from the site with all
Item No. 12 I-AH-2501-02 necessary equipments and transportation. 231.77 Sq.M. 130
Parking Level plan
Providing and laying Plain Cement Concrete (PCC) 1:2:4 (1 cement :
coarse sand : 4 graded stone aggregate of 20 mm nominal size) in
flooring of 75 mm (3") average thickness, including embedding 8 mm
TMT bar jali at 300 mm (1'-0") c/c spacing in both directions, properly
Ground floor tied with binding wire and fixed in position before concreting.
Parking Level plan The work shall include cost of all materials, labor, machinery,
formwork (if required), compaction, finishing, curing, and all leads and
lifts, complete as per standard specifications and as directed by the
Engineer-in-Charge.
Providing and laying machine-cut Kota stone slabs of size
approximately 600 mm × 600 mm (2'×2') and 20 mm thick, free from
cracks, cavities, or other defects, laid over a 20–25 mm thick cement
mortar bed (1:4, cement : coarse sand) on a 3" (75 mm) PCC base,
properly leveled and compacted to required slope to ensure drainage
as per site conditions.
Parking Level plan
Joints shall be filled with neat cement slurry mixed with matching
pigment, slabs rubbed, machine-ground, and polished to a smooth and
The rate shall include cost of all materials, labour, tools, equipment,
curing, finishing, and all leads and lifts, complete as directed by the
Engineer-in-Charge.
Demolition of existing damaged white marble as indicated in drawings,
removal and disposal of unserviceable marble pieces off-site, including
Banking hall first
Item No. 15 I-AH-2501-03 all required hand and power tools, cutting, chiselling, breaking, careful 6.97 Sq.M. 130
dismantling to avoid damage to adjoining finishes, stacking of
serviceable materials, loading, transport, and all leads & lifts.
Providing and laying White Agariya Marble slabs of size approximately
900 mm × 600 mm (3'×2') and 15 mm to 18 mm thick, free from cracks,
cavities, and other defects, laid in flooring or skirting over a 20–25 mm
thick cement mortar bed (1:4), properly leveled and compacted to
required slope for drainage as per site conditions.
Banking hall first
Item No. 16 I-AH-2501-03 Joints shall be filled with neat white cement slurry mixed with pigment 7.05 Sq.M. 2700
(matching the marble shade), cleaned, rubbed, polished, and finished
to a smooth and even surface.
The rate shall include cost of all materials, labour, mixing, laying,
finishing, curing, cleaning, and all leads and lifts, complete as directed
by the Engineer-in-Charge.
Providing and applying one coat of primer and three coats of approved
exterior paint (approved by the Bank & Architect), after thorough
Item No. 17 I-AH-2501-02 surface preparation including cleaning, sanding, removal of old paint, 217.15 Sq.M. 255
Parking Level plan
and finishing wall surface with putty wherever necessary. Complete
with all materials, labour and equipment, as specified
Providing and laying premium quality vitrified tiles (300 x 600) for
Basement floor, Dado as per approved design of VERMORA and confirming to IS:
Item No. 18 Banking hall first 15622 of approved make in colours and shades as specified laid on 10.78 Sq.M. 1200
floor 20m thick cement mortar 1:3 ( 1 cement: 3 coarse sand) including
grouting the joints with white cement and matching pigment etc.
Providing and installation of POP gypsum ceiling with all necessary
framework installation, board attachment, finishing work and light
Item No. 19 I-AH-2501-01 Basement floor 4.04 Sq.M. 699
cutting according to the light selection as shown in the drawing. Board
room (washroom).
Installation of wooden Glass door (3' X 7'-9") with 3" X 3.5" wooden
frame with polish and 5mm clear glass fixed in between the fram as
Item No. 20 I-AH-2501-01 Basement floor 1.00 no. 25000
indicated at the area shown in the drawing with polish to be matched
with board room partition and door.
Repair and refurbishment of the existing wooden ceiling in the pantry
area corridor, including replacement/rectification of damaged
Item No. 21 I-AH-2501-01 Basement floor 6.97 Sq.M. 650
members, as required, and providing all necessary materials, labour,
and equipment, complete (as per site condition)
Providing and installation of Plywood plament with 1mm laminate on
Item No. 22 I-AH-2501-01 Basement floor all side (6'6" x 2' x 3") for 1.5 ton splite Ac in bank locker waiting area. 1.21 Sq.M. 3295
As indicated in the drawing
Safely remove and refix the same exiting telephone black granite on all
Basement floor,
I-AH-2501-01 I- sides of lift door with BIOFLEX of Kerakoll including rubbing complete
Item No. 23 Banking hall first 10.36 RM 230
AH-2501-03 Granitic slab(mirror polish) 20 mm thick with all exposed edge
Demolition of exiting terrace floor (with microcement or terrazzo)
Above stair cabine,
flooring, disposal of unserviceable materials and debris with all lead
Item No. 24 Terrace Floor, 330.35 Sq.M. 340
and lift from the site with all necessary equipments and
Guest house floor,
transportation. To obtain clear slab surface for treatment.
Providing and applying chemical water proofing treatment with
cement polymer modified based waterproof compound like Tap Crete
P151 of CICO or equivalent without net in three coats in terrace
Above stair cabine, balconies and depressed portions including treatment up to 300 mm
Item No. 25 Terrace Floor, on side with (CC 1:2:4) 100X100 mm vata at corners vertical & 330.35 Sq.M. 610
Guest house floor, horizontal as per manufacturers specifications and direction of
engineer-in-charge and furnishing a guarantee bond of 10 years. (Only
plan area shall be measured, vata & treatment on joints and corner
shall not be measured separately and paid for.)
Providing and laying premium quality waterproof white ceramic tiles
size (12" x 8") for terrace. confirming to IS: 15622 of approved make
Above stair cabine, as specified laid on 20mm thick cement mortar 1:3 ( 1 cement:
Item No. 26 Terrace Floor, coarse sand) including grouting the joints with white cement and 330.35 Sq.M. 945
Guest house floor matching pigment etc. considering with material with all the lead and
lift. with slop ration of 1:80 for proper water dranage from the terrace
and balcony area.
staircares area,
Banking hall First Dismantling old aluminium windows, ventilators etc. shutters including
I-AH-2501-02 I- floor, Mezzanine chowkhats architraves, holdfasts and other attachment etc. complete
AH-2501-03 I- floor, Conference and stacking them within the premises condidering all lead and lift.
Item No. 27 230.48 Sq.M. 290
AH-2501-04 I- hall second floor, Including all necessary equipments, labor, scaffolding, etc. for removal
AH-2501-05 Guest house floor of aluminum windows from outside without disturbing exiting the
safety grills installed inside.
staircares area, Providing and fixing Fix aluminum windows of approved Jindal sections
I-AH-2501-02 I- Banking hall First (as per drawing no. 101) with anodized coating (make and finish to be
floor, Mezzanine approved by the Bank and Architect), including all necessary fittings,
floor, Conference labour, equipment, and scaffolding. Windows shall be fixed from the
hall second floor, exterior side of building without disturbing the existing safety grills
Guest house floor installed inside. Dimensions (width and height) shall be taken at site as
AH-2501-101 per actual condition, and installation shall be carried out as per typical
window drawing provided, complete in all respects.
Providing and fixing two track sliding openable aluminum (full height
Banking hall First
I-AH-2501-02 I- floor, Mezzanine 8') windows of approved Jindal sections (as per drawing no. 101) with
anodized coating (make and finish to be approved by the Bank and
AH-2501-03 I- floor, Conference
Architect), including all necessary fittings, labour, equipment, and
Item No. 29 AH-2501-04 I- hall second floor, 37.25 Sq.M. 3850
scaffolding. Windows shall be fixed without disturbing the existing
AH-2501-05 I- Guest house floor
safety grills installed inside. Dimensions (width and height) shall be
AH-2501-101 taken at site as per actual condition, and installation shall be carried
out as per typical window drawing provided, complete in all respects.
Providing and fixing two track sliding openable on top and fix window
Banking hall First in the bottom of aluminum windows of approved Jindal sections (as
I-AH-2501-02 I- floor, Mezzanine per drawing no. 101) with anodized coating (make and finish to be
AH-2501-03 I- floor, Conference approved by the Bank and Architect), including all necessary fittings,
Item No. 30 AH-2501-04 I- hall second floor, labour, equipment, and scaffolding. Windows shall be fixed without 53.45 Sq.M. 4500
AH-2501-05 I- Guest house floor disturbing the existing safety grills installed inside. Dimensions (width
AH-2501-101 and height) shall be taken at site as per actual condition, and
installation shall be carried out as per typical window drawing
provided, complete in all respects.
Providing and fixing two track sliding openable aluminum windows of
Banking hall First
I-AH-2501-02 I- floor, Mezzanine approved Jindal sections (as per drawing no. 101) with anodized
coating (make and finish to be approved by the Bank and Architect),
AH-2501-03 I- floor, Conference
including all necessary fittings, labour, equipment, and scaffolding.
Item No. 31 AH-2501-04 I- hall second floor, 23.92 Sq.ft. 3850
Windows shall be fixed without disturbing the existing safety grills
AH-2501-05 I- Guest house floor
installed inside. Dimensions (width and height) shall be taken at site as
AH-2501-101 per actual condition, and installation shall be carried out as per typical
window drawing provided, complete in all respects.
Providing and fixing glass louvered aluminum windows of approved
Banking hall First
I-AH-2501-02 I- floor, Mezzanine Jindal sections (as per drawing no. 101) with anodized coating (make
and finish to be approved by the Bank and Architect), including all
AH-2501-03 I- floor, Conference
necessary fittings, labour, equipment, and scaffolding. Windows shall
Item No. 32 AH-2501-04 I- hall second floor, 17.37 Sq.M. 3950
be fixed without disturbing the existing safety grills installed inside.
AH-2501-05 I- Guest house floor
Dimensions (width and height) shall be taken at site as per actual
AH-2501-101 condition, and installation shall be carried out as per typical window
drawing provided, complete in all respects.
Banking hall First
Providing & fixing of Bird/Pigeon net will high quality net (approved by
floor, Mezzanine
I-AH-2501-02 I- the bank with a guarantee or warranty of 5 years) with all necessary
floor, Conference
AH-2501-03 I- hooks and wire string on the all side of the opening for better
Item No. 33 hall second floor, 143.62 Sq.M. 226
AH-2501-04 I- protection. instalation at all height. Including all material, labour,
Guest house floor
AH-2501-05 transpotation, scaffolding, etc. complete as per direction of site in
Banking hall First
floor, Mezzanine
floor, Conference Applying priming coat and two coat of oil paint over existing metal
Item No. 34 hall second floor, safety grill, after all preparing of the surface by thoroughly cleaning 204.01 Sq.M. 180
Guest house floor with sand paper and necessary chemicals.
Repair and refurbishment on the overhead water tank with removal of
all tile/other material from the wall and floor surface, including
Above stair cabine disposal of unserviceable materials and debris with all lead and lift
Item No. 35 33.26 Sq.M. 240
on Terrace floor from the site with all necessary equipments and transportation. To o
btain clear surface for treatment.
Providing and applying 2 coats of mala plaster with chemical
waterproofing treatment using cement polymer modified waterproof
compound such as Tapcrete P-151 of CICO or approved equivalent,
Above stair cabine including application of glass-fiber/net reinforcement in three coats on
Item No. 36 33.26 Sq.M. 695
on Terrace floor all wall and floor surfaces of the overhead water tank, complete with
all necessary materials, equipment and labour as per site conditions
and instructions.
Providing and laying premium quality waterproof white ceramic tiles
size (12" x 8") for Overhead water tank. confirming to IS: 15622 of
approved make as specified laid on 20mm thick cement mortar 1:3 (
Above stair cabine
Item No. 37 cement: 3 coarse sand) including grouting the joints with white 33.26 Sq.M. 850
on Terrace floor
cement and matching pigment etc. on all wall and floor surface of
under ground water tank, considering with material with all the lead
Repair and refurbishment of existing 25 mm thick flush door, including
supply and installation of 1 mm thick laminate on both sides, with
Item No. 38 Terrace floor necessary surface preparation, adhesive, hardware fittings, and 3.34 Sq.M. 1950
finishing, complete with all materials, labour, equipment, and with all
leads and lifts as specified.
Supply, fabrication and fixing of MS door (single leaf) of clear size 4′-6″
× 7′-6″ (to be checked at site), fabricated from 50 × 50 mm MS box
section frame and fitted with 12 mm bright bar grill at 150 mm ×
mm (6″×6″) centres, including intermediate stiffeners / cross members
Item No. 39 Terrace floor as required, supply & fixing of all necessary hardware (hinges, tower 69.00 KG 140
bolt, aldrop, handle, lock plate etc.), necessary welding, grinding,
cleaning, one coat red-oxide primer, complete with supply, fabrication,
erection, adjustment, scaffolding, labour, tools, transport, lead & lift,
and as per site conditions.
Conference hall
Dismantling of the existing balcony roofing, comprising MS fabrication
and polycarbonate sheet covering, including ridges, hips, valleys,
floor and Guest
I-AH-2501-05 gutters, and all associated fittings. Serviceable materials shall be
Item No. 40 house floor 56.20 Sq.M. 180
I-AH-2501-105 carefully stacked for reuse, and unserviceable materials disposed of
with all leads and lifts. complete in all respects as directed including
all necessary labour, equipment, and scaffolding.
Supply, fabrication and fixing of MS box section fabricated roof using
sections of1) 80 X 40 X 3mm, 2) 50 X 50 X 3mm and 3) 25 X 25 X 2mm
Conference hall (as per typical drawing, to be verified with site conditions), including
Balcony provision of intermediate stiffeners/cross members wherever
second floor and required. The work shall also include supply and fixing of all necessary
Item No. 41 Guest house floor hardware such as metal plates, American bolts, tower bolts, aldrops, 745.00 KG 140
Balcony etc.; complete welding, grinding, surface cleaning, and application of
one coat of red-oxide primer. The item is inclusive of complete supply,
fabrication, erection, alignment/adjustment, scaffolding, labour, tools,
transportation, with all leads and lifts, executed as per site conditions
and directions of the Engineer-in-Charge.
Supply, fabrication and fixing of pre-coated galvanized iron (GI) roofing
sheets of approved make, profile and colour (approved by the bank
Conference hall and the Architect), including cutting, shaping, aligning and fixing in
Balcony position with self-drilling/self-tapping screws with EPDM washers,
second floor and complete over MS purlins. The work includes necessary overlaps,
Item No. 42 Guest house floor ridges, hips, valleys, etc. and sealants to make the roofing fully 56.20 Sq.M. 840
Balcony watertight, as per typical drwaing, site condition, specifications. The
item is inclusive of complete supply, fabrication, erection,
alignment/adjustment, scaffolding, labour, tools, transportation, with
all leads and lifts, executed as per site conditions and directions of the
Engineer-in-Charge.
Supply, fabrication and fixing of MS hollow box pipe frame in the
Banking Hall (double height area as indicated in the drawing and to be
verified at site), fabricated from 100 × 50 x 3mm MS hollow box
section with intermediate stiffeners/cross members as per approved
drawings. The work shall include cutting, welding, grinding, cleaning,
Banking hall First
Item No. 43 I-AH-2501-03 provision of all necessary hardware, erection, alignment and 351.00 KG 140
adjustment, complete with scaffolding, labour, tools, transport, lead
and lift. The surface shall be finished with one coat of red-oxide primer
and two coats of approved oil paint of shade approved by the Bank.
The work shall be executed in accordance with site conditions,
specifications, and as directed by the Engineer-in-Charge.
Repair and refurbishment of existing metal fabrication works in the
building wherever necessary, including staircases, railings, grills, doors,
windows, ventilators, gates, and other fabricated items. The work shall
comprise dismantling damaged/loose members, straightening, re-
Item No. 44 All floor welding, tightening of joints, replacement of worn-out 100.00 KG 140
sections/hardware, alignment and adjustment, grinding. The item shall
AH-2501-05 include supply of required MS sections, hardware, consumables,
scaffolding, labour, tools, transport, lead & lift, and shall be executed
as per site conditions and directions of the Engineer-in-Charge.
Demolition of existing dado tiles as indicated in the drawings (inside
the Board Room), including careful removal of tiles, mortar bedding
and backing where required. The work shall include collection and
stacking of serviceable material and disposal of all unserviceable
materials, debris and rubbish with all leads and lifts outside the site
Item No. 45 I-AH-2501-01 Basement floor 1.95 Sq.M. 420
premises, using necessary equipment, labour, tools and transportation.
After demolition, the surface shall be prepared and finished with one
coat of 12 mm thick smooth cement plaster (1:4 cement–sand mix) in
line, level and plumb.
Removal, repair, and refurbishment of existing plaster in the building
wherever necessary, including all walls, ceilings, staircases, corridors,
and other areas. The work shall include careful scraping/removal of
damaged or loose plaster, cleaning of surfaces, filling of cracks, and
preparation of the substrate for new plaster.
Item No. 46 All floor 46.45 Sq.M. 415
Executing of double coat plaster comprising of base coat 12 mm thick
cement–sand plaster (1:4) applied evenly over the prepared surface
and finishing coat 6 mm thick cement–sand plaster (1:3) applied over
the base coat to achieve a smooth, uniform, and level finish ready for
painting or other finishing.
Providing and applying 1 coat of primer and 3 coats of interior paint of
Basement floor,
I-AH-2501-01 I- approved make (approved by the bank and the architect) after all
Mezzanine floor,
Item No. 47 AH-2501-04 I- preparing of the surface by 167.22 Sq.M. 315
Conference hall
AH-2501-05 throughly cleaning with sand paper removing old paint and finsihing
wall surface with putty if necessary
Banking hall First Providing and fixing Aluminium Composite Panel (ACP) cladding in
floor, Mezzanine drainage duct area and service duck area, suitable for external weather
floor, Conference conditions, using 3 mm / 4 mm thick ACP sheets of approved make,
Item No. 48 hall second floor, shade and finish, fixed on aluminium framing with necessary cleats, 38.55 Sq.M. 3250
Guest house floor fasteners, weather sealant, and accessories, complete in all respects
AH-2501-05 including scaffolding, labour, materials, equipment, and disposal of
debris, all as directed by the Engineer-in-Charge.
Demolition of existing parapet wall and metal railing at the balcony of
the Conference Hall floor as indicated in the drawings. The work shall
include careful dismantling, breaking, and removal of the parapet wall
and metal railing, along with collection, stacking of serviceable
Conference hall
materials (if any), and disposal of all unserviceable materials and
Item No. 49 I-AH-2501-05 second floor Level 7.51 CBM 1150
debris from the site with all necessary leads and lifts.The work shall be
carried out using appropriate tools, equipment, and labour, ensuring
safety and protection of adjacent finishes and structures, as directed
by the Engineer-in-Charge.
Demolition of exiting balcony floor tiles and entrance lobby floor tiles,
disposal of unserviceable materials and debris with all lead and lift
Conference hall from the site with all necessary equipments and transportation. To
Item No. 50 I-AH-2501-05 second floor Level obtain clear slab surface for treatment. The work shall be carried out 45.34 Sq.M. 340
plan using appropriate tools, equipment, and labour, ensuring safety and
protection of adjacent finishes and structures
Providing and applying chemical water proofing treatment with
cement polymer modified based waterproof compound like Tap Crete
P151 of CICO or equivalent without net in three coats in terrace
Conference hall balconies and depressed portions including treatment up to 300 mm
Item No. 51 I-AH-2501-05 second floor Level on side with (CC 1:2:4) 100X100 mm vata at corners vertical & 40.13 Sq.M. 650
plan horizontal as per manufacturers specifications and direction of
engineer-in-charge and furnishing a guarantee bond of 10 years. (Only
plan area shall be measured, vata & treatment on joints and corner
shall not be measured separately and paid for.)
Providing and laying premium vitrified tiles of 8–10 mm thickness and
size 600 × 600 mm (24″ × 24″) of approved make, shade, and finish
(approved by bank and the Architect). Tiles shall be laid over 20 mm
thick cement mortar (1:3) with proper leveling, alignment, and
Conference hall adequate slope in balconies for water drainage as per site conditions.
Item No. 52 I-AH-2501-05 second floor Level Joints shall be grouted with white cement and matching pigment for a 45.34 Sq.M. 1400
plan neat and uniform finish. The work includes surface preparation,
cutting, fitting, finishing, cleaning, and disposal of debris, along with all
labour, materials, tools, transportation, lead, and lift, executed as
directed by the Engineer-in-Charge.
Supply and installation of 10 mm thick toughened glass railing with SS-
304 handrail along with all necessary accessories, clamps, brackets,
and fittings as per approved drawings. The railing shall be fixed on a 6″
wide granite pedestal, secured with chemical adhesive of approved
Conference hall make (such as Kerakoll or K2). The work includes civil preparation,
Item No. 53 second floor Level proper leveling, finishing, and installation of glass panels with stainless 17.68 RM 5100
AH-2501-105 steel clamps or channels, along with the SS-304 handrail fixed on top.
The scope also covers supply of all materials, accessories, labour,
scaffolding, tools, transportation, lead & lift. executed as per site
conditions and directions of the Engineer-in-Charge.
Dismentalling existing M.S. railling and Providing & fixing new
Item No. 54 I-AH-2501-02 grade S.S. Railling. (Market rate) 9.14 RM 3000
Parking Level plan
Repair and refurbishment of basement bathroom with removal of all
tile/other material from the wall and floor surface, including disposal
Item No. 55 Basement floor of unserviceable materials and debris with all lead and lift from the 21.62 Sq.M. 225
site with all necessary equipment's and transportation. To obtain clear
surface for treatment.
Providing and applying 2 coats of mala plaster with chemical
waterproofing treatment using cement polymer modified waterproof
compound such as Tapcrete P-151 of CICO or approved equivalent,
I-AH-2501-01 I- including application of glass-fiber/net reinforcement in three coats on
Item No. 56 Basement floor 22.57 Sq.M. 695
AH-2502-201 all wall and floor surfaces of the bathroom, complete with all
necessary materials, equipment and labour as per site conditions and
Providing and fixing white urinal (CERA Cat. No. S4020112) with all
fittings, fixtures, and plumbing materials, including supply and
installation of Jaquar flushing valve (Model PRS-CHR-077) with
I-AH-2501-01 I- installation box and control cock and bottle trao. All connections shall
Item No. 57 Basement floor 1.00 unit 16000
AH-2502-201 be leak-proof and tested under working pressure. Repairing and
making good disturbed surfaces to match existing finish complete as
per manufacturer’s specifications and directions of the Engineer-in-
Supplying and fixing CERA Corren wall-hung wash basin with built-in
counter on right (Cat. No. S2030109), including approved waste
coupling, bottle trap, necessary CPVC/UPVC plumbing fittings,
Item No. 58 Basement floor brackets/fasteners, and all fixtures required for proper installation. 1.00 unit 10000
The work shall include connecting to existing water supply and waste
line, sealing joints, testing for leak-proof performance, as directed by
the Engineer-in-Charge.
Providing and fixing pillar cock of Jaquar make, Model OPP-CHR-
15001PM, including all necessary fittings such as flexible connection
pipe, approved stopcock/angle valve below the counter, and required
Item No. 59 Basement floor accessories for proper installation. The work shall include fixing, 1.00 unit 4500
connecting to existing water supply, ensuring leak-proof joints, testing,
and making good any disturbed surfaces, complete as directed by the
Engineer-in-Charge.
Supplying and fixing CERA wall-hung WC, Casper model (Cat. No.
S1044173), including supply and installation of Jaquar Metropole Flush
Valve (Model: FLV-CHR-1095NSQ) in chrome finish, complete with all
required CPVC/UPVC plumbing fittings, brackets, fasteners, and
Item No. 60 Basement floor installation accessories. The work includes proper mounting and 1.00 unit 27500
alignment of the WC, connection to the existing water supply and
waste line, sealing of all joints, and testing the system for leak-proof
performance. All work shall be carried out as per manufacturer’s
specifications and the directions of the Engineer-in-Charge.
Providing and fixing ISI-marked Nahani Trap of approved make, with
minimum 75 mm water seal and C.P./SS grating, including all fittings,
I-AH-2501-01 I- cutting and preparing floor, fixing in cement mortar, connecting to
Item No. 61 Basement floor 1.00 unit 2000
AH-2502-201 waste/SWR pipe, making all joints leak-proof, testing, and restoring
the floor finish. Complete with all materials, labour, and tools as
directed by the Engineer-in-Charge
Providing and fixing a health faucet of approved make and quality,
including a flexible hose (minimum 1.0 meter), wall hook/holder, and
all necessary fittings. The work shall include complete plumbing with
I-AH-2501-01 I- CPVC/UPVC pipes, connection to an angle valve/stopcock (supply and
Item No. 62 Basement floor 1.00 unit 2600
AH-2502-201 installation), ensuring proper water flow, leak-proof joints, and secure
fixing. All materials, labour, tools, and testing shall be included, and
the work shall be carried out in accordance with manufacturer’s
specifications and the directions of the Engineer-in-Charge.
Providing and laying premium quality vitrified anti-skid floor tiles of
size 600 × 600 mm (VERMORA or approved equivalent), conforming to
IS:15622, in specified colours and shades. The tiles shall be laid over a
20 mm thick cement mortar bed in proportion 1:3 (1 cement : 3 coarse
I-AH-2501-01 I- sand), properly leveled and aligned. Necessary slope shall be provided
Item No. 63 Basement floor 3.59 Sq.M. 1400
AH-2502-201 in the flooring to ensure smooth water flow towards the nahani trap
(NT). Joints shall be filled with white cement mixed with matching
pigments to obtain a uniform finish. The work shall be carried out as
per manufacturer’s specifications, architect’s drawings, and the
direction of the Engineer-in-Charge, complete in all respects.
Providing and laying premium quality vitrified tiles (300 x 600) for
Dado as per approved design of VERMORA and confirming to IS:
Item No. 64 Basement floor 15622 of approved make in colours and shades as specified laid on 22.60 Sq.M. 1200
20m thick cement mortar 1:3 ( 1 cement: 3 coarse sand) including
grouting the joints with white cement and matching pigment etc.
IN WORDS : THIRTY FOUR LAKH TY FORTY FIVE THOUSAND NINE HUNDRED AND FOURTEEN ONLY
I/We _________________________________________________ am/are willing to carry out the above work at ___________________ % above/below ___________________
percent (should be written in figures and words) of the estimated rate mention above estimated amount of my/ours tender work out as under.
ESTIMATED AMOUNT PUT TO TENDER
Total Amount Rs. ________________________
Total Amount Rs. ________________________
SIGNATURE OF THE BIDDER
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. Cover Page.pdf
2. MEMORUNDUM - Renovation work of mithakhali RNSB.pdf
3. Schedule B.pdf
4.Final Drg. File.pdf
5. INSTRUCTION TO BIDDER.pdf
6.TECHNICAL SPECIFICATION.pdf
7.TENDER DECLARATION FORM (1).pdf
8.VENDOR LIST (1).pdf
9.TERMS AND CONDITIONS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].