Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAdmitted-Finance | ₹2.0 L | L1 | Admitted-Finance |
| 2 | L2₹2.0 LAdmitted-Finance | ₹2.0 L | L2 | Admitted-Finance |
| 3 | L3₹2.0 LAdmitted-Finance 110 MINI SHOPPING COMPLEX NEHRU MARKET JAMMU | ₹2.0 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Rishabh Electricals and Mechanical Works L3 | JAIN LUBRICANTS AND MOTOR SPARE PARTS L2 | R M ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Replacement of refrigerant pipes of 33TR packaged air conditioning units- 2 &4 by way of SITC of new refrigerant pipes in place of stolen pipes of ward no. 18 along with allied works govt. SMGS hospital, Jammu.The job includes SITC of new refrigerant pipes with proper insulation of size 5/8” for discharge side and 7/8” for suction side along with allied accessories and fittings – 130 feet each per machine from three compressors per machine to their outdoor units - 2 jobs.The job also includes brazing of the refrigerant pipes and fittings as per site requirement along with providing and fitting of necessary supports at required intervals to prevent damages from vibrations and other effects. The job further includes supplying and filling of refrigerant 407 – 12 kg per machine after leak detection test of the compressors’ lines (both suction and discharge) by way of flushing the line and holding pressure with nitrogen for 24 hours, rectification of the leakages and then vacuumizing of the refrigeration line with deep vacuumizing pump and then charging the compressors with refrigerant R-407. Complete job also includes testing of system and rectification of any fault thereafter of package AC system. Complete job as per directions of Engineer-in-charge and includes cost of material, all kinds of taxes, labour charges, tools & tackles, other unforeseen materials required for execution of job and also involves cost of technicians, as and when required to attend the complaints of machines and its rectification. Moreover, all the electro-mechanical materials used should conform to relevant IS/BIS/CE standards and codes. | 1 | job | 0.02 ₹2.0 L | 0.02 ₹2.0 L | 0.02 ₹2.0 L |
Tender Value
₹2.1 L
EMD Value
₹4,500
Closing Date
2 May 2026, 4:00 pmClosed
XEN MH DIVISION GMCH JAMMU
XEN MH DIVISION GMCH JAMMU
REFRIGERANT PIPES OF33TR PACKAGED AIR CONDITIONING UNITS 24BY WAY OF SITC OF NEW REFRIGERANT PIPES IN PLACE OF STOLEN PIPES OF WARD NO. 18 ALONG WITH ALLIED WORKS GOVT. SMGS HOSPITAL, JAMMU.
2026_PWDJK_308579_1
MHDJ/e-NIT 14 of 2026-27
Open Tender
Repair and Maintenance Services
10 days
smgs
as per e nit
2 documents required · 2 mandatory
₹200
Yes
Convener, purchase committee, Directorate of ISM
₹4,500
6 May 2026
24 Apr 2026
4 May 2026
24 Apr 2026
2 May 2026
27 Apr 2026
24 Apr 2026 - 2 May 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division GMCH Jammu.
REFRIGERANT PIPES OF33TR PACKAGED AIR CONDITIONING UNITS-2&4BY WAY OF SITC OF NEW REFRIGERANT PIPES IN PLACE OF STOLEN PIPES OF WARD NO. 18 ALONG WITH ALLIED WORKS GOVT. SMGS HOSPITAL, JAMMU
MHDJ/e-NIT 14 of 2026-27 Dated: 24.04.2026 Due : 02.05.2026
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate including GST to be quoted by the bidder Rs. P Currency Convertion against each Item Quoted Currency in INR / Other Currency Rebate on old parts in Percentage (%) if any Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Net Cost of item Rs. P
1 Replacement of refrigerant pipes of 33TR packaged air conditioning units- 2 &4 by way of SITC of new refrigerant pipes in place of stolen pipes of ward no. 18 along with allied works govt. SMGS hospital, Jammu.The job includes SITC of new refrigerant pipes with proper insulation of size 5/8” for discharge side and 7/8” for suction side along with allied accessories and fittings – 130 feet each per machine from three compressors per machine to their outdoor units - 2 jobs.The job also includes brazing of the refrigerant pipes and fittings as per site requirement along with providing and fitting of necessary supports at required intervals to prevent damages from vibrations and other effects. The job further includes supplying and filling of refrigerant 407 – 12 kg per machine after leak detection test of the compressors’ lines (both suction and discharge) by way of flushing the line and holding pressure with nitrogen for 24 hours, rectification of the leakages and then vacuumizing of the refrigeration line with deep vacuumizing pump and then charging the compressors with refrigerant R-407. Complete job also includes testing of system and rectification of any fault thereafter of package AC system. Complete job as per directions of Engineer-in-charge and includes cost of material, all kinds of taxes, labour charges, tools & tackles, other unforeseen materials required for execution of job and also involves cost of technicians, as and when required to attend the complaints of machines and its rectification. Moreover, all the electro-mechanical materials used should conform to relevant IS/BIS/CE standards and codes. job Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
BOQ_999823.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid