Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹37.4 L+₹12,455 (0.33%)Rejected-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹37.8 L+₹50,309 (1.35%)Rejected-AOC HQ CWE AHMEDABAD | GANDHINAGAR | GUJARAT | 382006 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹38.0 L+₹72,126 (1.93%)Rejected-AOC 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹38.4 L+₹1.1 L (2.87%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹73,000
Closing Date
26 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
IMPROVEMENT TO E/M INTERNAL AND OTHER SERVICES WITH REPLACEMENT OF ELECTRICAL FITTING AND FIXTURES AT OTM ACCN AT ICGAE PORBANDAR UNDER GE I CG PORBANDAR
2022_MES_514099_2
8725
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
GE I CG PORBANDAR
₹73,000
Yes
20 May 2022
19 Apr 2022
27 Apr 2022
19 Apr 2022
26 Apr 2022
20 Apr 2022
60 days
Amount
SCHEDULE 'A'
Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc to be measured and paid for seprately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc complete all as spd and directed.
Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces inclduing painting .
Disconnecting electric connections and taking down old unserviceableMCCB, MCB SPN/SP/TP and DB's of any capacity.
Modular Point wiring
M & L for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors, conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in existing PVC cassing capping surface/recessed conforming to IS: 9537 (Part 3)- 1983, colour-coded as specified in IS: 11353- 1985, including factory made sunken, galvanized, not less than 1.00 mm thick modular flush sheet metal enclosure having top, bottom, side and back-wall knockout for conduit entry from any direction, conforming to IS: 14772- 2000 and including modular cover-plates complete all as specified in IS: 732- 1989 and directed.Make Havells/ Anchor/RR Cables
(a) One light/ Bulb Holder /fan/exhaust point / bell point controlled by one, one way switch
(d) One light point controlled by 2, Two way switch
(c) One 5 pin socket outlet 5/6 amps on the same board.
(d) One 5 pin socket oulet 5/6 amps on independent board..
M & L for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694- 1990, having multi?drawn thin strands of electrolytic copper conductors, conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in existing PVC cassing capping conforming to IS: 9537 (Part 3)- 1983, colour-coded as specified in IS: 11353- 1985, including factory made sunken, galvanized, not less than 1.00 mm thick modular flush sheet metal enclosure having top, bottom, side and back-wall knockout for conduit entry from any direction, conforming to IS: 14772- 2000 and including modular cover?plat for 15 Amp Independent swotch and socket point complete all as specified in IS: 732- 1989 and directed Make Havells/ Anchor/RR Cables
M & L for point wiring of 4.00 Sqmm using ISI marked 1.1 kV grade single core FR?LSH flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors, conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm size PVC cassing capping surface/recessed conduits, conforming to IS: 9537 (Part 3)- 1983, colour-coded as specified in IS: 11353- 1985, including factory made sunken, galvanized, not less than 1.00 mm thick modular flush sheet metal enclosure having top, bottom, side and back-wall knockout for conduit entry from any direction, conforming to IS: 14772- 2000 and including modular cover-plates complete all as specified in IS: 732- 1989 and directed.Make Havells/ Anchor/RR Cables
S & F in replacement of modular type 6 A one-way SP switch, conforming to IS: 3854-1997 with finger proof terminalcomplete as specified and directed.Make : Legrand Arteor Cat- Part No : 573400 or equivalent in L&T(Entice)/ABB(Snieo).
S & F replacement of modular type 16 A one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal complete as specified and directed . Make : Legrand Arteor Cat- Part No : 573410 or equivalent in L&T(Entice)/ABB(Snieo).
S & F replacement of modular type 2/3 pin combined shuttered type 6 A socket conforming to IS: 1293- 2005 complete as specified and directed. Make : Legrand Arteor Cat- Part No : 573470 or equivalent in L&T(Entice)/ABB(Snieo).
S & F replacement of modular type 2/3 pin combined shuttered type 6/16 A socket conforming to IS: 1293- 2005 complete as specified and directed. Make : Legrand Arteor Cat- Part No : 573471 or equivalent in L&T(Entice)/ ABB(Snieo).
S & F replacement of modular type 6 A bell-push conforming to IS: 8884- 1978 with finger proof terminal complete all as specified and directed. Make : Legrand Arteor Cat- Part No : 573413 or equivalent in L&T(Entice)/ABB(Snieo).
S & F replacement of Bell multi music type 230 Volt complete as specified and directed.
S & F replacement of modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984 complete as specified and directed. Make : Legrand Arteor Cat- Part No : 573469 or equivalent in L&T(Entice)/ABB(Snieo)
S & F 6 A, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5 mm complete all as specified and directed. Make : ABB(Snieo) / L&T(Entice) / Anchor.
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm NB UPVC medium grade surface/recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, all complete as specified and directed. Make: RR Kabel, Polycab, Havells, Finolex (HR-FR flexible cable) & Precision, Prince, Supreme (PVC conduit) NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of concealed conduit shall be measured as one length.
2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire
2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire
Supply and fixed SPN DB double door 240 Volt 4 way with 200 amp rated bus bar compleete with fixing accessories complete all as specified and as directed .Make Legrand/ C&S/L&T
Supply and fixed SPN DB double door 240 Volt 8 way with 200 amp rated bus bar compleete with fixing accessories complete all as specified and as directed .Make Legrad/ C&S/L&T
Supply and fixed SPN DB double door 240 Volt 12 way with 200 amp rated bus bar compleete with fixing accessories complete all as specified and as directed. Make Legrand/ C&S/L&T
Supply and fixed TPN DB double door 240 Volt 4 way with 200 amp rated bus bar compleete with fixing accessories complete all as specified and as directed. Make Legrand/ C&S/L&T
Supply and fixing in replacment of following MCB
MCB SP 230 Volt 6-32 Amp C series complete all as specified and as directed . Make Legrand/ C&S/L&T
MCB DP 230 Volt 16 to 32 Amp C series complete all as specified and as directed .Make Legrand/ C&S/L&T
MCB FP 415 Volt 40-63 Amp C series complete all as specified and as directed .Make Legrand/ C&S/L&T
Supply and fixing in replacement of MCCB thermal magnetic release 63 Amp 4pole 415 Volt 25 KA complete all as specified and as directed Make Legrand/ C&S/L&T
Supply and fixing in replacement of MCCB thermal magnetic release 100 Amp 4pole 415 Volt 25 KA thermal magnetic release complete all as specified and as directed Make Legrand/ C&S/L&T
Ceiling/Exhaust Fan
Taking down of followin items for servicing, cleaning all the dust partical and oiling and greasing the bearing and cheking the electrical connection, including painting and refixing of ceiling fan/exhaust fan and wall mounted fan in situ complete aall as spd and directed. Note: (i) Spare parts will be measured and paid separatly . (ii) Rewinding/repair of fan motor will be measured and paid seprately.
Ceiling Fan 1200 mm sweep
Exhaust Fan 240/300 mm
Exhaust Fan 450 mm
Wall mounted fan 300 mm
M & L for cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling all as spd and directed by Engineer-in-Charge.Note Taking down and refixing charges will be paid under relvent items
Ceiling Fan 1200 mm sweep
Exhaust Fan 240 mm
Exhaust Fan 450 mm
Wall mounted fan 450 mm
Supply only spare parts of Fan/Exhaust fan of following rating all as spd and directed
Capacitor 2.5 MFD
Capacitor 3.15 Mfd
Ball Bearing No 6201
Ball Bearing No 6202
Mild steel Down Rod 600 mm Long with Clamp nut bolts & split pin as par sample
Mild steel Down Rod with Clamp nut bolts& split pin for 900 mm Long as par sample
Ceiling Fan Blade suitable for 1200 mm sweep as per sample.
Ceiling fan canopy suitable for 1200 mm sweep
3 core 1.5 sqmm PVC insulated cable 1.5 m long with 3 pin 15 Amp plug top.
Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V. Make : Sudhir.
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessoriesprewired and including connecting up with three core flexible copper conductor cable with suitable size.Make : Sudhir
S & F Flame proof wall mounted fan complete with all electric accessories, 230 volt 400 mm sweep minimium air deleivery 245 CFM and all as aspecified and directed.Make : Sudhir
S&F Metal flush box 1 module and make good and pain the wall with matching colour.Make ; Havells/Legrand/L&T(Entice)
S&F Metal flush box 3 module and make good and pain the wall with matching colour.Make ; Havells/Legrand/L&T(Entice)
S&F Metal flush box 4 module and make good and pain the wall with matching colour.Make ; Havells/Legrand/L&T(Entice)
S&F Metal flush box 6 module and make good and pain the wall with matching colour.Make ; Havells/Legrand/L&T(Entice)
S&F Metal flush box 8 module and make good and pain the wall with matching colour.Make ; Havells/Legrand/L&T(Entice)
S&F Metal flush box 10 module and make good and pain the wall with matching colour.Make ; Havells/Legrand/L&T(Entice)
S&F Metal flush box 12 module and make good and pain the wall with matching colour.Make ; Havells/Legrand/L&T(Entice)
White cover plate with frame, 1 Module.Make ; Havells/Legrand/L&T(Entice)
S&F White cover plate with frame 3 Module.Make ; Havells/Legrand/L&T(Entice)
S&F White cover plate with frame 4 Module.Make ; Havells/Legrand/L&T(Entice)
S&F White cover plate with frame 6 Module.Make ; Havells/Legrand/L&T(Entice)
S&F White cover plate with frame 8 Module.Make ; Havells/Legrand/L&T(Entice)
S&F White cover plate with frame 10 Module.Make ; Havells/Legrand/L&T(Entice)
S&F White cover plate with frame 12 Module.Make ; Havells/Legrand/L&T(Entice)
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.Make : Havells/Philips/Wipro.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make : Havells/Philips/Wipro
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.Make : Havells/Philips/Wipro
S&F 25 mm dia Rigid non-metallic PVC casing capping inclusive of junction boxes (1 to 4 way), medium duty, including all Tees, bends, elbows, reducers, bell mouth tube ends, and fixing couplers, lock nuts, saddles, pipe hooks etc, fixed in repairs. Make Press fit/Finolex/Anchor
S&F 32 mm dia Rigid non-metallic PVC casing capping inclusive of junction boxes (1 to 4 way), medium duty, including all Tees, bends, elbows, reducers, bell mouth tube ends, and fixing couplers, lock nuts, saddles, pipe hooks etc, fixed in repairs .Make Press fit/Finolex/Anchor
S&F 18/20 Watt recess mounted LED down light, extruded alumimium housing with high efficiency diffuser and integrated electronic driver with high efficiency long life LED chips, PF>0.95, system liminouse eifficiency 100 Lumen/Watt, Operating voltage 140V-270V, 50 Hz including electrical connection with 3 core flexible Cu conductor cable of appropriate size complete all aspecified and directed.Make : Wipro Cat No CRDL11R023HP57 or equivalent in Philips/Osram.
Split AC
M & Lfor servicing and testing of Split type air conditioners of 1.5/2 ton capacity of any make complete for minimum two times during the contract period of each unit by cleaning cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing , oiling, compressor greasing of blower motor, checking and removing any vibration, remvoing and cleaning the air filter pad testing after fixing and topup gas upto desired level at site all as directed.
M&L for detecting the cause of leakage in any type/capacity of 1.5 tonne AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity including testing for smooth functioning complete all as spd and as directed by Engr-In Charge Notes :- (i) Dismantling of unserviceable compressor , cost of refrigarent gas and re-installation of serviceable compressor after repairing are deeemed to be included in the quoted rates .
Supply and fix in replacment of following parts of Split type AC1.5/2 Ton capacity complete all as spd and as directed by Engr-In Charge
(i) PCB suitable for split type AC 2 TR with chordless remote complete all as specified and as directed.
(ii) PCB suitable for split type AC 1.5 TR with chordless remote complete all as specified and as directed.
(iii)Condenser coil of copper of 2 run for 1.5 Ton AC complete all as specified and as directed.
(iv)Condenser coil of copper of 2 run for 2TR AC complete all as specified and as directed.
(v) Blower motor,single phase,230V,3 speed for 1.5 /2TR AC all as spd and directed.
(iii) Blower motor,single phase,230V,3 speed for 2TR AC all as spd and directed.
(vii) condenser fan motor single phase,230V for 1.5 /2TR AC all spd in directed.
(viii) capacitor 36/45 mfd 230 volt suitable for 1.5 Ton ac
(ix) copper tube with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge of exsisitng size mm bore including brazing etc
(xi) Running capcitor 50 MFD for 2 TR capacity
(xii) Supply and fix in replacement Air filtter for split type AC as per sample
M&L Shifting of Split type AC1.5/2 Ton from one place to another place including fixing on wall and replacement of refrigerant tubing as per site std requirement upto 6 RM,any insulated complete all as spd and as directed Note- Gas charging if required deemed to be included in unit rate.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed Make ABB/Havells/legrend
M & L for dismentling unserviceable compressor fromSplit type A/C various capacity from any location , supply and fix new hermatically sealed compressor unit (coy repaired) , assembling, brazing pressure/vaccum testing initial oil charging, gas charging,reinstalling A/C in situ and connecting to electric supply and testing all as directed and specified. Make : Voltas/Carrier/Hitachi Note : (i) Job including removing A/C from any site/height/location (ii) Transporting A/C unit to repair workshop and back to site (iii) Loading/unloading etc
M & Lfor charging of refrigerant with exsisitng refrigerent in refrgerator of 165 to 315 Ltr capacity, deepfreezer and water Cooler of 40/80 Ltr and double door refergerator of 984 Ltr capacity with appropriate quantity including testing for smooth functioning complete all as spd and as directed .
Taking down of split type AC 2 Ton from site for replacement of outdoor unit and re installing existing model split type AC at site and including refixing of outdoor unit on walll mounted including bracket of MS and replacement of refrigerant tubing as per site std requirement upto 6 RM,any insulated complete all as spd and as directed Note- Gas charging if required deemed to be included in unit rate.Make : Carrier/Voltas/Hitachi.
Taking down of split type AC 1.5 Ton from site for replacement of outdoor unit and re installing existing model split type AC at site and including refixing of outdoor unit on wall mounted including bracket of MS and replacement of refrigerant tubing as per site std requirement upto 6 RM,any insulated with AC deflect Anti dust blowing AC windshield cover complete all as spd and as directed Note- Gas charging if required deemed to be included in unit rate Make : Carrier/Voltas/Hitachi
Taking down of split type AC 2 Ton from site for replacement of indoor unit and re installing existing model split type AC at site and including refixing of indoor unit on walll mounted including replacement of refrigerant tubing as per site std requirement upto 6 RM,any insulated with AC deflect Anti dust blowing AC windshield cove complete all as spd and as directed Note- Gas charging if required deemed to be included in unit rate.Make : Carrier/Voltas/Hitachi
Taking down of split type AC 1.5 Ton from site for replacement of indoor unit and re installing existing model split type AC at site and including refixing of indoor unit on wall mounted including replacement of refrigerant tubing as per site std requirement upto 6 RM,any insulated with AC deflect Anti dust blowing AC windshield cover complete all as spd and as directed Note- Gas charging if required deemed to be included in unit rate Make : Carrier/Voltas/Hitachi
S&F in replacement of rusted/damaged MS bracket for 1.5/2 Ton Out door unit of existing AC and reinstalled at site all as directed.
S&F LED taxiway medium intensity Omini-direction, elevated light with one watt LED for operation at 6.6 amps, series circuit with an integrated encapsulated electric module, with Die-cast aluminium alloy frangible body finished with stove enamel aviation yello with stainless steel hardware eith lens of heat resistant and thermal shock presed glass provided with heat and weather resistant neoprene rubber gasket, equiped with a 14" long secondary lead as per FAAL-823, mounted on a breakable coupling, confirming IS 7785 Part I-V, including blue lens and CI base plate. Make : AMA or equivalent as approved by GE.
Supply and fixing LED flood light 80 watt 230 V AC of 5700K outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and all as spd and directed by Enge-in-Charge. Make : Wipro (LR06-981-XXX-57-XX) or equivalent in Philips/Cropmton.
S&F LED flood lights 120W , high pressure die cast aluminium housing, IP-66, Nominal Lumen output 14400 lm, PF>0.95, Operating voltage 150-230V AC, 50 Hz including 3 core 1 Sqmm PVC insulated copper cable from control box to fitting complete all as specified and directed by Engr-in-Charge.make : Wipro (LF20-132-060-57-G3) or equivalent in Philips/Cropmton.
Supply and fix LED street light nominal watt 40 W, 5700K and IP 66 , high pressure die cast aluminium housing with street optic LENS for uniform light distribution, 140-270V , 50 Hz, PF>0.95 and fixing of existing steet light poles including 3 core 1 Sqmm PVC insulated copper cable from control box to fitting complete all as specified and directed by Engr-in-Charge.make : Wipro (LR02-451-XXX-57-G1) or equivalent in Philips/Cropmton.
M & L for disconnecting the exsisitng incoming and outgoing cable connection of taki track light and refixing the same with other location with PCC work complete all as specified and as directed
Supply, laying & testing in replacement of insulated stranded plain anneled copper PVC insulated & PVC sheathed of 5 KV insulated and PVC sheathed of 5 Kv grade single core 6 Sqmm .
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core.Make : Havells/RR Cables/Polycab.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Soft/ Loose soil and including taking out of PCC cable cover and getting out complete all as specified and directed
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Supply and Lay in replacment of OD 50mm Double Wall Corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings laid in trenches/road/nallah or fixed along wall poles or laid under floor. Make : Rex/Poly/Gemini.
S&F LED Bollard light Cool white 6500 K of wattage 11 watt with integrated mounting base plate and driver complete with housing dark grey RAL 7043 with long life time of 50,000 hours (70% lumen maintenance @ Tc = 35ºC), IP65 protection and IK10 impact resistance including PCC (1:2:4) foundation of suitable size for mounting of light fitting including mounting pole with accessories not less than 1.2m height complete all as specified and directed. Make Wipro cat Ref No LB14-131-XXX-65-08 or equivalent to Philips. Note: The Contractor should submit LM 79 & LM 80 certificates for the batch of fittings procured before incorporating fittings in the work.
Repair/Replacement of unserviceable bollard Led light of 5W - 10W size including 3 core 1 Sqmm PVC insulated copper cable from existing point with folloewing items :-
Driver Cat No : BGD21040, Make : Bajaj
Chips of suitable size.
Repair /Replacement of solar lights with following items :-
12v, 100AH Solar Battery.
200WP, 24V Solar Panels.
Charge Controller unit + driver
S&F in repair of Search lights with following items
150W Driver
OM ENGINEERING
roxy enterprise
MADHAV ENTERPRISE
RAJESH ENTERPRISE
jitendra c joisar
SURESH ELECTRICALS
shree chamunda enterprise
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .