Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | ₹21.6 L Quoted ₹23.4 L | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹25.0 LRejected-Finance 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | ₹25.0 L | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹25.8 LRejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹25.8 L | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹28.1 LRejected-Finance | ₹28.1 L | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹28.4 LRejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹28.4 L | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | Raman Electric Trading Co L5 | u and v engineers and consultants L2 | MM Engineers L4 | The Rahul Vig L3 | Saurav Enterprises L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays, locating fault of LT cable and stay assembly etc not exceeding 10 square metre on plan and getting out in any type of soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and directed. | 371 | Cubic Metre | 80 ₹29,680 | 80 ₹29,680 | 140 ₹51,940 | 100 ₹37,100 | 60 ₹22,260 |
| 2.00 | All as per Ser item No 1.00 here in before but depth exceeding 1.5 metre and not exceeding 3.0 metre. | 1 | Cubic Metre | 100 ₹100 | 398 ₹398 | 200 ₹200 | 450 ₹450 | 90 ₹90 |
| 3.00 | Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed. | 167 | Cubic Metre | 20 ₹3,340 | 50 ₹8,350 | 5 ₹835 | 100 ₹16,700 | 30 ₹5,010 |
| 4.00 | Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | 204 | Cubic Metre | 20 ₹4,080 | 10 ₹2,040 | 5 ₹1,020 | 100 ₹20,400 | 40 ₹8,160 |
| 5.00 | Material and labour for sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and directed. | 130 | Cubic Metre | 200 ₹26,000 | 200 ₹26,000 | 400 ₹52,000 | 350 ₹45,500 | 50 ₹6,500 |
| 6.00 | Supply and lay bricks, common burnt clay, sub class "B', old size, laid in perpendicular direction to cable as cable protection complete all as specified and directed. | 14 | 1000 Nos | 2,900 ₹40,600 | 2,500 ₹35,000 | 4,550 ₹63,700 | 3,500 ₹49,000 | 1,800 ₹25,200 |
| 7.00 | All as per Ser Item No 6.00 here in before but except bricks complete all as specified and directed.
Note:- Old bricks retrieved from Ser Item No 11.00 to 20.00 here in after shall be re-used. | 2.8 | 1000 Nos | 400 ₹1,120 | 500 ₹1,400 | 4,550 ₹12,740 | 1,000 ₹2,800 | 500 ₹1,400 |
| 8.00 | Material and labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc. complete all as specified and directed. | 0.4 | Cubic Metre | 1,000 ₹400 | 2,500 ₹1,000 | 2,000 ₹800 | 2,000 ₹800 | 800 ₹320 |
| 9.00 | Material and labour for cement concrete (1:3:6) type C-1 using 20mm stone graded crushed stone aggregate as in pole and strut, stay around the pole etc complete all as specified and directed. | 4 | Cubic Metre | 1,000 ₹4,000 | 2,000 ₹8,000 | 2,200 ₹8,800 | 3,000 ₹12,000 | 800 ₹3,200 |
| 10.00 | Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts including connecting and testing for any size omplete all as specified and directed. (Excavation / earth work & sand cushioning, bricks and joint shall be measured & paid for separately). | 600 | Running Metre | 10 ₹6,000 | 20 ₹12,000 | 45 ₹27,000 | 6 ₹3,600 | 40 ₹24,000 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
11 Apr 2026, 6:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
REPAIR AND MAINT REPLACEMENT OF OH UG LT NETWORK INCL MISC WORK AT SECTOR A UNDER GE UTILITY AMBALA
2026_MES_756172_1
CA NO GE U AMB 69 OF 2025-26
Open Tender
Civil Works
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹66,000
28 Apr 2026
13 Mar 2026
13 Apr 2026
13 Mar 2026
11 Apr 2026
28 Mar 2026
13 Mar 2026 - 20 Mar 2026
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays, locating fault of LT cable and stay assembly etc not exceeding 10 square metre on plan and getting out in any type of soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and directed.
All as per Ser item No 1.00 here in before but depth exceeding 1.5 metre and not exceeding 3.0 metre.
Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and directed.
Supply and lay bricks, common burnt clay, sub class "B', old size, laid in perpendicular direction to cable as cable protection complete all as specified and directed.
All as per Ser Item No 6.00 here in before but except bricks complete all as specified and directed. Note:- Old bricks retrieved from Ser Item No 11.00 to 20.00 here in after shall be re-used.
Material and labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc. complete all as specified and directed.
Material and labour for cement concrete (1:3:6) type C-1 using 20mm stone graded crushed stone aggregate as in pole and strut, stay around the pole etc complete all as specified and directed.
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts including connecting and testing for any size omplete all as specified and directed. (Excavation / earth work & sand cushioning, bricks and joint shall be measured & paid for separately).
Supplying, laying, connecting and testing in replacement XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. complete all as specified and directed. Note: (i) Earth work, sand, bricks, removing, returning filling Aluminium thimbles/lugs will be paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
All as per Ser Item No 11.00 here in before but for 3.5 core 25 Sqmm.
All as per Ser Item No 11.00 here in before but for 3.5 core 35 Sqmm.
All as per Ser Item No 11.00 here in before but for 3.5 core 50 Sqmm.
All as per Ser Item No 11.00 here in before but for 3.5 core 70 Sqmm.
All as per Ser Item No 11.00 here in before but for 3.5 core 95 Sqmm.
All as per Ser Item No 11.00 here in before but for 3.5 core 120 Sqmm.
All as per Ser Item No 11.00 here in before but for 3.5 core 150 Sqmm.
All as per Ser Item No 11.00 here in before but for 3.5 core 185 Sqmm.
All as per Ser Item No 11.00 here in before but for 3.5 core 240 Sqmm.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as specified and directed.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6 sqmm 2 core complete all as specified and directed.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 4 sqmm 2 core complete all as specified and directed.
Supplying and fixing in replacement of light grade galvanised mild steel pipe 80 mm bore with all fittings, laid under roads, drain, paths, fixed to poles/walls with suitable mild steel clamps, bolts, nuts and washers complete all as specified and directed. Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule.
All as per Ser Item No 24.00 here-in-before but of size 50 mm bore.
Dismantling and taking down old unsv Precast Concrete Pole LT pole and Supply, fix and erection of Precast Concrete Pole 9.0 mtr long in true vertical position 102x172 mm at top 102x279 mm at bottom class-10 incl providing black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr including 2 bands of radium tape of 2' width greeen & red colour above the coping of pole starting with black strip complete all as specified and directed. Note:- (i) Earth work and PCC shall be measured and paid seperately. (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
Dismantling and taking down old unsv Steel tubular LT pole and Supply, fix and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts,nuts and screws as specified type 410 SP-31, 09 meter long, providing synthetic enamel aluminium paint over one coat of red oxide and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 mtr including 2 bands of radium tape of 2' width greeen & red colour above the coping of pole starting with black strip, incl arrangement of galvanised/Mild steel circular lantern carriage arrangement suitable for 5 luminares symmetrically on steel tubular poles complete all as specified and directed. Note:- (i) Earth work and PCC shall be measured and paid seperately (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
Supply and fixing in replacement of stay assembly complete with all accessories, such as stay plate 230x230x6 mm, stay rod 215 cm long and 16 mm dia with nuts incl GI bow turn buckle, GI stay wire, Loop type insulator etc all as per electrical plate No 1 or SSR part 1 complete all as specified and directed.
Material and labour in replacement of Loop insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, large size with overall dimensions 90mm x 140mm, clearance of hole 25.5 mm complete all as specified and directed.
Material and labour in replacement for shackle type porcelain vitreous white or brown insulator including GI straps washers, insulator bolts and nuts for working pressure 1100 volts, 75 mm hight, 90 mm dia, section of strip 30mmx3mm & dia of bolt 12 mm complete all as specified and directed.
Material and labour in replacement for pin type insulator porcelain vitreous white or brown 1100 volts grade 100 mm hight and 65 mm dia with GI spindle two washer and one GI nut complete all as specified and directed.
Dismantling and taking down old unserviceable ACSR conductor incl cutting, welding complete all as specified and directed .
Material and labour for aluminium conductor steel reinforced (ACSR) conductor of size 6/1 x 2.59 (Weasel) and 6/1 x 2.11 (Squirrel) ISI marked for LT over head lines on poles including complete stretching, tightening of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor complete all as specified and directed .
Dismantling and taking down old unserviceable cross-arms of M.S. channel or angle sections etc. complete incl cutting, welding complete all as specified and directed .
Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel section incl nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Supply and fixing indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 x 10-50 Sqmm complete all as specified and directed .
Supply and fixing indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-120 Sqmm complete all as specified and directed .
Supply and fixing indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 150-300 Sqmm complete all as specified and directed .
Supply and fixing straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4 x 25-50 Sqmm complete all as specified and directed .
Supply and fixing straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-120 Sqmm complete all as specified and directed .
Supply and fixing straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 150-300 Sqmm complete all as specified and directed .
Dismantling and taking down old unsv earthing & material and labour for earthing complete with galvanised earth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 25x4 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GI protection pipe (light grade), funnel, wire mesh, cast iron cover and frame etc including testing on completion complete all as specified and directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost
Material & labour for repairing existing earthing any type incl making & cleaning of earth pit, repair of pits, fixing of new funnel , pit cover, painting on pit with cement base white paint complete all as specified and directed. Note: Cost of funel, pit cover, cement work, PCC work and painting etc incl is quoted rate.
Supply and fixing in replacement of MCCB TPN 400 Amps, 415 Volts, 36KA, 4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete all as specified and directed .
Supply and fixing in replacement of MCCB TPN 315 Amps, 415 Volts, 36 KA, 4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete all as specified and directed .
Supply and fixing in replacement of MCCB TPN 250 Amps, 415 Volts, 25 KA, 4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete all as specified and directed .
Supply and fixing in replacement of MCCB TPN 200 Amps, 415 Volts, 25 KA, 4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete all as specified and directed .
Supply and fixing in replacement of MCCB TPN 160 Amps, 415 Volts, 25 KA, 4 pole ,fixed thermal release fixed magnetic protection incl complete all as specified and directed .
Supply and fixing in replacement of MCCB TPN 100 Amps, 415 Volts, 16/18 KA, 4 pole fixed thermal release fixed magnetic protection incl complete all as specified and directed .
Material and labour for Detecting of fault in cable LT with fault locator equipment supplying of LT electric supply (430 Volts) to make the LT cable serviceable with Straight through joint of size 70-300 Sqmm complete all as specified and directed . Note:- (a) The LT fault which is detected through cable fault locator will only be paid under this item. (b) Transportation charges of cable fault locator and DG set deemed to be included in the quoted rate. (c) Cable fault locator will be provided by the contractor for even single LT fault and no delay on this account will be acceptable otherwise penalty will levied Rs 500.00 per hour. (d) Straight through joint, 95 to 300, sqm, Labour charges, excavation and making joint deemed to be including in quoted rate.
Supply and fixing LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 4 line as per IS complete all as specified and directed .
Supply and fixing LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 3 line as per IS complete all as specified and directed .
Re-streching of loose over head ACSR conductor of any type/GI wire and repair of the broken conductors and adding new length( if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire complete all as specified and directed. Note:- Each Run should be measured as one length.
Labour only for trimming of Tree branches OH lines of HT/LT & maintain approaching minimum clearance of 3 Mtr from branches. Proper shutdown will be taken and maintained in the register complete all as specified and directed.
Material and labour in replacement of aluminium terminals (thimbles) after cutting the worn out/faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminium lugs including crimping with crimping tools in the existing LT cable 25 Sqmm 4 core upto 50 Sqmm including necessary connection complete all as specified and directed.
All as per Ser item No 55.00 here in before but size of LT cable 70 Sqmm 3.5 core upto 120 Sqmm 3.5 core.
All as per Ser item No 55.00 here in before but size of LT cable 150 Sqmm 3.5 core upto 300 Sqmm 3.5 core.
Material and labour for shifting heavy items upto 5 Ton /using excavator / cleaning areas / cleaning site by providing crane/hydra/excavators/tractors/trolley etc as required at site complete all as specified and directed.
Material & Labour for repair of LT panel of any type and any size including replacement of old unsv items such as busbar, insulator, CT/PT coils, insulating sleeves, front and rear doors, door hinges, gland, lugs volt meter, ammeter, indicator, locking arrangement and internal copper wiring after cleaning of surface including removing rusted particles, carbon removing dust tightening nut, bolts welding of hinges if damaged complete all as specified and directed. Note : (i) Cost of marking description on the front door as per direction of Engr-in-Charge is incl in quoted rate (ii) Cost of misc items like copper cable, lugs thimbles etc if required are included in quoted rates. (iii) Cost of welding works such as hinges, locking arrangement, door and angles are included in qouted rates.
Material & Labour for surface cleaning of LT steel tubular poles 9 mtrs long including removing rusted particles painting with two coats of synthetic enamel aluminium paint over a coat of red oxide primer including stand cross arms, bracing, supports,clamps eye hooks, security light bracket clamps etc providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with cement base white paint complete all as specified and directed. Note : (i) The quoted rate shall include making of numbers on self adhesive stickers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall include the repairing of coping with cement / PCC (1:2:4)
Material & Labour for cement base paint for PCC pole 9 mtr including black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paint and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including cross arms bracing supports, clamps, eye hooks, security light bracket, clamp etc incl incl repairing and painting on coping with cement base white paint complete all as specified and directed. Note : (i) The quoted rate shall include making of numbers on self adhesive stickers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall include the repairing of coping with cement / PCC (1:2:4).
Supply and fixing in replacement of fabrication of Kiosk box made out of fibre material complete with TPN ,aluminium bus and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and directed. Make: Havells/Sintex or equivalent as approved by GE.
Material and labour for fabrication and commissioning of box type display boards of size not less than 1.5M x 1.0M x 0.2M made out of ACP sheet of 3mm thickness with english alphabets and numerics cut out and designed out of 3mm thick acrylic sheet neatly pasted on the ACP board with flushed LED strips running along the sides of the acrylic letters to be fixed on wall with necessary fixing arrangement as per the site requirement on roof, wall etc. complete all as specified and directed. Note:- (a) Before fabrication of the display board, the contractor has to produce a paper printout detailing all documents and matter to be displayed so as to get it inspected and passed. (b) Matter to be displayed, colour of the ACP sheet and colour of Retro Reflective sheet will be as specified and directed. (c) The quoted rate is deemed to be inclusive of cost of labour and materials required for fixing of the display board at the location including providing electrical connections complete as specified by Engr-in-Charge.
Material and labour for fixing of Layout diagram of LT or HT lines/ flow chart/ shock treatment chart etc of size 1.5M x 1.0M for power houses, sub stations and other E/M installations as per the requirement at various locations made out of pre laminated board with digital printing, pasting side beadings of decorative aluminium channel with proper fixing arrangement etc complete all specified and directed. Note:- (a) Before fabrication of the display board, the contractor has to produce a paper printout detailing all documents and matter to be displayed so as to get it inspected and passed . (b) Matter to be displayed, colour of the ACP sheet and colour of Retro Reflective sheet will be as specified and directed . (c) The quoted rate is deemed to be inclusive of cost of labour and materials required for fixing of the display board at the location including providing electrical connections complete as specified by Engr-in-Charge.
Supply & fixing in replacement of LED street light fitting 90 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover/ toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 5700K, LED efficiency >110 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.270A, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs : LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular pole incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed . Note :- PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to street shall be measured and paid for separately.
Dismantling and taking down old UNSV LT panel and Supply, installing, testing & commissioning outdoor type cubical panel board of size 1.2mX1.0mX.5m, outer shell made out of 3.15 mm thick CRCA sheet with 60 to 70% perspex sheet of min 3 mm thickness and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and back openable double door system and cable alley (Each door hinged with body at 3 places should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl AL bus bar of 800 Amp - 03 Nos and 400 Amp - 01 No bus bar for Nuetral, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-56 and breaking capacity 65 KA comprising of the following :- (a) MCCB 630 Amps, 36 KA 4 pole 415 Volts AC, adjustable type, (incoming)-01 No. (b) MCCB 200 Amp, 415 volt, 4 pole, breaking capacity 16 KA , adjustable type (Outgoing)-02 Nos. (c) MCCB 160 Amp, 415 volt, 4 pole, breaking capacity 16 KA , adjustable type (Outgoing)-02 Nos. (d) MCCB 125 Amp, 415 volt, 4 pole, breaking capacity 10 KA , adjustable type (Outgoing)-01 Nos. (e) RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos (f) Multi function meter for reading volt, Amp, KWH, Frequency etc including CT Coils complete. (g) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates.
Supply, installing, testing & commissioning in replacement of bus bar chamber, outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 40x40x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated and completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl bus bar of 600 A of 3 phases and 300 amp of neutral bar , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-65 and breaking capacity 65 KA comprising of the following :- (a) MCCB 400 Amps, 4 pole 415 Volts AC , 36 KA - 01 No (Incoming) (b) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete are included in quoted rates.
Supply, fabrication, erection, connection, testing and commissoning of factory made, CPRI approved,cubical type, outdoor type LT panal board, totally enclosed , dust, weather and vermin proof 1100 Volt grade , 50HZ AC supply made out by 3.15mm thick CRCA sheet steel for load bearing and 2 mm thick for non load bearing, fully compartmentalised, with IP 65 protection all as per conferming to IS 2417 of 1962 complete including the following accessories housed in complete all as specified and as directed. (a) Al bus bar of suitable size with PVC insulated colour coded heat shrinkabale type sleeves, of rating 400 Amps, mounted on non cracking resin type insulators - 01 Job (b) MCCB, 4 pole, 415 volts, 36 kA, with Fixed Thermal Magnetic release, 250 Amps, - 01 No (Incoming). (c) Interconnection of MCCBs to Busbar with Al strip of suitable size with PVC insulated colour coaded heat shrinkable type sleeves - 1 Job (d) MCCB, 4 pole, 415 volts, 25 kA, with fixed thermal magnetic release, Ics = 100% Icu, 63 Amps, -06 Nos (Outgoing). (e) Digital type Ammeter with sellector switch and Set of CTs - 01 Set (f) Digital type volt meter with sellector switch '0' to '500 Volts - 01 No (g) Indication lamps R, Y & B - 01 Set (h) Provisioning of copper tinned cable glands for incoming & Outgoing cables. - 01 Job (j) Interconnection of metering equipment with PVC insulated unsheathed, single core cables 1100 volts grade of suitable size - 01 Job Notes- (i) The quoted rate shall include minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (v) Cable will be entered in panles through gland. (vi) Cost of marking description and matter on the front door as specified and directedis incl in quoted rate.
Supply and fixing in replacement off load change over switches 4 pole 100 Amps, 415 volts, with enclosure complete all as specified and directed.
Supply and fixing in replacement off load change over switches 4 pole 200 Amps, 415 volts, with enclosure complete all as specified and directed.
Material and labour for painting to LT panel board/LT feeder pillar box indoor/out door type of size inner shell & outer shell including angle iron frame by applying two coats of sunthetic enamelled paint over a coat of red oxide primer after cleaning of panel board inner shell & outer shell by means of rubbing by sand paper grinding and removing rusted and corroded particles cleaning with cloths including reparing smooth surface for painting complete all as specified and directed.
Repairing of existing unserviceable PCC coping of LT/HT pole by breaking completely and material and labour for PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) of size 600X600X300mm including form work and applying two coats of cement base paint complete all as specified and directed.
Taking down old unserviceable Indicator any type any colour and supply and fixing new Indicator red/yellow/green including making electrical connection with suitable size of copper lugs duly crimped complete all as specified and directed.
Supply and fix in replacement of bracket made out of GI tubing single piece not welded, bended at proper angle of size 40mm dia, light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide primer to the bracket including 1.0 sqmm 3.0 core flexible copper cable in PVC conduit with clamp from juction box to connecter of street light fitting complete all as specified and directed.
Supply and fix in replacement of MS clamp suitable for holding street light bracket on steel/PCC pole made out of 40 mm x6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia with flat washer 3mm thick -02 No for each including painting with aluminium paint over one coat of red oxide primer to the M.S clamps complete all as specified and directed.
Taking down old unsv and Supply and fixing of Retro reflective sign board of size 600 X 750 sqmm made of ACP sheet of 3 mm thick fixed on MS frame with legs of MS angle section 35 mm X 35 mm X 6 mm on PCC 1:3:6 type 750 mm above the ground level and 600 mm below the ground level. The back ground of board to be provided with red colour, letters and border with white retro reflective tape. Same description will be mentioned on both side of ACP Sheet. The size of letters and description will be as per direction of Engr-in-charge, board will be complete fixing/grouting with nut/bolts/Anchor fastener with washers.
Material & labour in replacement for fabrication of door/surfaces of LT panel indoor/outdoor as per existing size / thickness/shape and fitted in the panel with door handle, formed gasket around doors, lock insets, earthing strips, door stay, hinges, rivets etc. including two coat of synthetic enamel paint by spray painting on inside/outside surface of panel complete all as specified and directed.
Note:- Amount of credit of Rs. 182573.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in PDF form which will be deducted offline while acceptance of tender.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.74 MB
BOQ_847012.xls
BOQ • 0.66 MB
Tender.pdf
Tender Documents • 0.79 MB
Download all tender documents and submit your bid