Executive Engineer
Executive Engineer PHDIVISION.KOLLAM
MLA ADF-CWSS to Oachira and adjoining Panchayath-General Civil Work- Construction of New tube well at Ward no.13 in Clappana Panchayath
2026_KWA_855955_1
.6/etender1/4763/EE/PHDNK
Open Tender
Civil Works - Water Works
60 days
Ward no.13 in Clappana Panchayath
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,760
₹46,770
16 Jun 2026
16 Jun 2026
24 Jun 2026
16 Jun 2026
23 Jun 2026
16 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Construction of tube well and pump house | ||||||
| 1.001 | OD237380/2024-2025:Boring /drilling bore well of required dia for casing / strainer pipe, by suitable method
prescribed in IS: 2800 ( part I), including collecting samples from different strata, preparing and submitting strata
chart/ bore, including hire & running charges of all equipments, tools, plants & machineries required for the job, all
complete as per direction of Engineer- in- charge, beyond 150 metre & upto 200 metre depth below ground
level.<br>Rocky strata including Boulders<br>400 mm dia | - | metre | - | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | OD237371/2024-2025:Supplying, assembling, lowering and fixing in vertical position in bore well ERW ( Electric Resistance
Welded ) FE 410 mild steel screwed and socketed / plain ended casing pipes or required dia , conforming
to IS 4270, of reputed & approved make, including painted with outside surface with two coats of
anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings
& accessories, all complete, forall depths, as per direction of Engineer-in-Charge.450 mm
nominal size dia having minimum wall thickness 8 mm | - | metre | - | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | 23.15.3:Providing and fixing Bail plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS : 2800 (part I).200 mm dia | - | each | - | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | 23.3.3:Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS : 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer- in- Charge.200 mm nominal size dia | - | metre | - | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | 23.4.3:Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer - in-charge200 mm nominal size dia | - | metre | - | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | 23.13.3:Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia | - | each | - | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | OD237360/2024-2025:Supplying, Conveying and stacking at site for taking measurement best quality round pebbles, which
should pass through 10 mm sieve and should retain in 5 mm sieve as per relevant IS Specification and
packing round the strainer pipe using pebble for graded size as directed by the department officers and
back washing including all labour charges cost and conveyance of water etc,complete. | - | cum | - | - | BI01010001010000000000000515BI0100001120 |
| 1.008 | OD237377/2024-2025:Clay packing around the well for perfect clay sealing using saddle clay including conveyance cost of all materials and labour charges etc complete | - | cum | - | - | BI01010001010000000000000515BI0100001121 |
| 1.009 | 23.12:Development of tube well in accordance with IS: 2800 (Part I) and IS : 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc.by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer - in-charge. | - | hour | - | - | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.56 MB
NIT6.pdf
Tender Documents • 0.54 MB
GENERALSPECIALCONDITION1.pdf
Other Document • 0.03 MB
BOQ_1446718.xls
BOQ • 0.31 MB
AdditionalSpecialConditions.pdf
Additional Documents • 0.08 MB
Download all tender documents and submit your bid