Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC | ₹1.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.9 L+₹30,131.50 (18.3%)Rejected-Finance | ₹1.9 L+₹30,131.50 (18.3%) | L2 | Rejected-Finance L2 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Not paid EMD |
Tender Value
Refer Docs
EMD Value
₹4,231
Closing Date
14 Oct 2024, 5:00 pmClosed
Director
Regional Cancer Centre Medical College Campus Medical College PO
URGENT REPAIR WORKS OF THE FIRE DETECTION AND ALARM SYSTEM INSTALLED AT VARIOUS BUILDING BLOCKS OF RCC
2024_RCC_685311_2
RCC/ENG-M/2024-25/E-97
Open Tender
Miscellaneous Works
Item Wise
14 days
RCC-TVM
Please refer Tender documents.
6 documents required · 6 mandatory
₹590
Yes
₹4,231
Yes
1 Mar 2025
28 Sept 2024
16 Oct 2024
28 Sept 2024
14 Oct 2024
30 Sept 2024
30 Sept 2024 - 14 Oct 2024
FIRE DETECTION AND ALARM SYSTEM
Supplying, installation, testing & commissioning of below False Ceiling UL approved optical smoke detector for detecting visible smoke particles with Mounting Base with inbuilt indicator having a smoke sensitivity of 1.9 +/- 0.6 %/ft. The LED shall be located in such a way that it shall be visible from the 360º
Supplying, installation, testing & commissioning of above False Ceilling UL approved optical smoke detector for detecting visible smoke particles with Mounting Base with inbuilt indicator having a smoke sensitivity of 1.9 +/- 0.6 %/ft. The LED shall be located in such a way that it shall be visible from the 360º
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supply of GI plane washer 16 mm
Supply of spring washer 16 mm
Supply and fixing of 3mm thick glass for manual call point box of size 80 mmx80 mm
Servicing of fire alarm control panels in A, B, C, D & E block of RCC
Supply and installation of single door FRP hose box with acrylic glass in front suitable for accommodate 63 mm dia hose pipe having 15 meter length with nozzle. Having front door with locking arrangement, handle and transparent acrylic sheet.
Replacement of damaged shut off nozzles in rubber hose made of PVC of jet spray type, strong and corrosion free, serrated end for hose fitting having a pressure rating of minimum 16 GPM @ 100 PSI.
Sythetic fibre circular woven jackated rubber lined fire hose delivery having 38Kg. Per Cm. Sq. burst pressure, 28Kg. Per Cm. proof pressure, 14Kg. Per Cm. working pressure as per IS:636 (ISI Marked) Type A in 15 Meters length, 63mm dia duly copper via bounded two coupling pair of male female parts any duly intantanous type, 63mm size as per IS:903 (ISI Marked)
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .