Executive Engineer, Irri. Mech. Dn. No.1, Vadodara
Providing, supplying, installing, testing, and commissioning of a SCADA-based Gate Operation, Monitoring and Control System, Including O and M and Non - Comprehensive Annual Maintenance Contract (AMC), at Panam Irrigation Project, Di-Mahisagar, Gujarat.
368487
NIT-11 of 2026-27
Open
Electronics Equipment
Works
Vadodara
14 documents required · 14 mandatory
₹3,600
Executive Engineer, Irrigation Mechanical Division No.1, Vadodara
₹1.5 L
23 Nov 2026
23 Nov 2026
23 Nov 2026
9 Dec 2026
23 Nov 2026
120 days
BILL OF QUANTITIES
1. The bill of Quantities shall be read in conjunction with the Instructions to Bidder,
Conditions of Contract, Technical Specifications and Drawings.
2. The quantities given in the Bill of Quantities are estimated and provisional, and are
given to provide a common basis for bidding. The basis of payment will be the actual
quantities of work ordered and carried out, as measured by the Contractor and verified by
the Engineer and valued at the rates and prices tendered in the priced Bill of Quantities,
where applicable, and otherwise at such rates and prices as the Engineer may fix within
the terms of the Contract.
3. The rates and prices tendered in the priced Bill of Quantities shall, except in so far as
it is otherwise provided under the Contract, include all constructional plant, layout,
supervision, materials, erection, maintenance, insurance, profit, taxes and duties,
together with all general risks, liabilities and obligations set out or implied in the Contract.
4. The rates and prices shall be quoted entirely in Indian Currency.
5. A rate or prices shall be entered against each item in the Bill Quantities, whether
quantities are stated or not. The cost of Items against which Contractor has failed to enter
a rate or price shall be deemed to be covered by other rates and prices entered in the Bill
of Quantities (in case of Item rate contract).
6. The whole cost of complying with the provisions of the Contract shall be included in
the items provided in the priced Bill of Quantities, and where no Items are provided
the cost shall be deemed to be distributed among the rates and prices entered for the
related items of Work.
7. General direction and descriptions of work and materials are not necessarily
repeated or summarized in the Bill of Quantities. References to the relevant sections
of the contract documentation shall be made before entering rates or prices against
each item in the Bill of Quantities.
8. The method of completed work of payment shall be in accordance with the
specification for Road and Bridge works. For building works specifications for
building are to be followed.
9. Errors will be corrected by the Employer for any arithmetic errors pursuant to
Clause 29 of the Instructions to Bidder.
10. Rock is defined as all materials which, in the opinion of the Engineer, required
blasting, or the use of metal wedges and sledgehammers, or the use of
compressed air drilling for its removal, and which cannot be extracted by ripping with a
tractor of at least 150 kw with a single rear mounted heavy dutyripper.
BILL OF QUANTITIES
Name of Work : Providing, supplying, installing, testing, and commissioning of a SCADA-
based Gate Operation, Monitoring & Control System, Including O&M and Non -
Comprehensive Annual Maintenance Contract (AMC), at Panam Irrigation Project, Di-
Mahisagar, Gujarat.
Item Quantities Item of Work Estimated Unit Total
No. Estimated Rate (In Amount
Figures) According to
1 10 Design, Engineering, Supply, Installation, 247450.00 No.
Testing and Commissioning (SITC) of Local
PLC/RTU-based automation system,
including development and configuration of
PLC/RTU software. The scope of supply
shall cover a control panel housed in a front-
opening industrial cabinet, complete with
power bus bars, MCBs, and all necessary
internal wiring. The system shall include a
suitably rated power supply for
uninterrupted operation of the PLC/RTU
panel, Local display, and industrial-grade
electrical fittings. All associated cabling, GI
conduits, and accessories required for
interconnection with field instruments shall
be provided as per site requirement. The
quoted price shall be inclusive of packing,
transportation, insurance, and delivery up to
the installation site, complete in all respects.
(Preferred OEM/Manufacturer-Schneider/
Honeywell/ Siemens or approved by
Engineer-in-charge)
2 20 Design, Engineering, Supply, Installation, 20200.00 No.
Testing and Commissioning (SITC) of Gate
Position Sensor System, comprising
proximity-type limit switches for open/close
end-position detection including all necessary
mounting hardware, industrial-grade
cabling, junction boxes, and accessories. The
scope shall include signal interfacing,
configuration, and integration with
PLC/RTU system for remote monitoring and
data acquisition as per approved drawings
and technical specifications. The quoted
price shall inclusive of supply, packing,
transportation, insurance, and delivery up to
site. (Preferred OEM/Manufacturer:
Kubler/Baumer/banner/P&F)
3 10 Design, Engineering, Supply, Installation, 45955.00 No.
Testing and Commissioning (SITC) of
inclination sensor for gate positioning. The
system shall be suitable for continuous
indication and monitoring of spillway gates,
including all necessary mounting hardware,
industrial-grade cabling, junction boxes, and
accessories. The scope shall include signal
interfacing, configuration, and integration
with PLC/RTU system for remote
monitoring and data acquisition as per
technical specifications. The quoted price
shall inclusive of supply, packing,
transportation, insurance, and delivery up to
(Preferred OEM/Manufacturer:
Kubler/Siemens/E&H/P&F or approved by
Engineer-in-charge)
4 1 Supply, lnstallation, Testing and 280780.00 No.
Commissioning (SITC) of Non-contact
RADAR-type water level transmitter with
minimum measuring range up to 20 M,
suitable for continuous
upstream/Downstream water level
measurement at head regulators. The scope
shall include sensor mounting arrangement,
weather-proof junction box,
converter,industrial-grade signal and power
cabling with 25mm MS conduits,electrical
fittings, earthing, and all accessories
required for reliable outdoor operation. The
system shall be complete in all respects and
installed, calibrated, and commissioned as
per technical specifications. The rate shall be
inclusive of supply, packing,transportation,
insurance, and delivery up to site.(Preferred
OEM/Manufacturer: Endress+ Hauser/
Emerson/VEGA/Siemens)
5 1 Design, Engineering, Supply, installation, 2474500.00 No.
testing, and commissioning (SITC) of Main
PLC Controller System with firmware-based
hot redundancy, including PLC hardware
and application software development. The
scope shall include a control panel housed in
a front-opening industrial cabinet, complete
with power bus bars, MCBs,
modem/communication modules, and
industrial-grade electrical fittings and
internal wiring. The system shall be provided
with suitably rated Switch Mode Power
Supply (SMPS), a 12-inch or larger HMI
display, and all necessary communication
interfaces for interconnection with associated
PLCs/RTUs. The complete system shall be
supplied, installed, configured, tested, and
commissioned as per approved drawings and
technical specifications, ready for integration
with the overall automation and SCADA
system. The complete system rate shall be
Inclusive of supply, packing, transportation,
insurance, and delivery up to site.(Preferred
OEM/Manufacturer-Schneider/Honeywell/
Siemens/ABB/Phoenix)
6 1 Supply, engineering, design, development, 1798810.00 No.
and customized SCADA software for server
and Client Edition for the complete
automation and monitoring system,
including system architecture design,
database configuration, graphics
development, alarm management, trends,
reports, and user access control. The
software shall be provided with perpetual
(lifetime) license, without recurring license
fees, and shall be fully compatible with the
supplied PLC/RTU and communication
systems. Scope shall include FAT, SAT,
documentation, source configuration backup,
operator training, and complete system
handover, strictly as per approved technical
specifications. The rate shall be inclusive of
all engineering, software development,
licensing, documentation, training, and
support required for successful
implementation. (Preferred
OEM/Manufacturer-Schneider/
7 10 Supply of Local RDOL started Control 116150.00 No.
panel(LSP) for local control of each gate for
15HP Cage induction motor. The panel
shall be made by 2mm thk CRCA sheet with
proper powder coating, containing door with
proper locking arrangement. Each panel
will house 3 phase SPD, 32 A MCCB/MPCB
with aux. and alarm switches, rotary handle,
Reversible DOL contactors, Short circuit and
O/L protections, DP MCB with trip aux.
Switch, Control transformer, control fuses
with bases,Signal multipliers cum isolators
for analogue and binary signals, Relay
modules, gate moving up, down, Trip lamps;
gate fully open/closed lamps; control supply
healthy and trip lamps, Local/Remote
selector switch, RAISE/LOWER/Emergency
stop push buttons, Thermostat, panel space
heater, illumination lamp, terminal blocks
for interfacing and interlocking gate top and
bottom limit/proximity switches, gate
position transmitters.
8 1 Preparation and submission of as-built 212100.00 No.
engineering drawings, layouts,
documentation for SCADA system, wiring,
and communication network. The scope shall
include Layout drawings, blueprints, and
actual implemented engineering drawings,
Marking, tagging, and ferruling of all cable
terminations at racks, Structured racking
and cable dressing. Complete details of all
active and passive components, reflecting the
actual site installation and implementation.
Submission of full documentation after
project commissioning, suitable for
operation, maintenance, and future
reference. The rate shall be inclusive of
preparation, verification, compilation, (3
Sets) A3 or better size of physical copy
printing, and delivery of complete as-built
documentation at site and submission on
appropriate size of flash drive (16GB) to the
project engineer in CAD and PDF format
9 4 Providing Technical Training of the 50500.00 Job
purchaser's personnel at the Project
office/onsite in assembly, start up, operation,
maintenance and/or repair of the supplied
goods. Course topics will include sensor
calibration, PLC/RTU & SCADA
configuration, data downloading, data
retrieval, collection, Trouble shooting,
processing maintenance requirements and
procedure for equipment configuration,
installation, site testing and commissioning
including training kit containing course
material in soft and hard copies.
10 1 Supply, Installation, testing and 469650.00 No.
commissioning of next generation firewall
for medium enterprise level, having 9 x 2.5G
Copper ports, 1 x 10G SFP+ port, minimum
2.1 GBPS throughput for site to site VPN,
firewall should support SD WAN capability
without any additional license XGS118.
(Preferred OEM/Manufacturer: Firewall-
Sophos, Sonic wall, Fortinet )
11 1 SITC of Monochrome, Duplex Wireless 45450.00 No.
Laser Printer, All-in-One with Scanner,
Copier, Fax, Auto Document Feeder, Mobile
Ready, 1 Year Limited Warranty, 42 PPM.
(Preferred Make:Cannon/Samsung/HP)
12 1 Supply, Installation, Testing and 600950.00 No.
Commissioning (SITC) of large-format
display (LFD) system for monitoring of
SCADA systems at the Dam Control Room,
comprising either 86-inch LED display (86
inch, 16:9, 1920×1080, Android 9.0
2HDMI, 2 USB, 3.5 Audio Output, Ethernet
Port, power supply arrangements, signal
cabling, terminations, configuration, and
system integration with the SCADA systems.
The complete system shall be supplied as per
technical specifications, ready for continuous
operation in control room environment. The
complete system rate shall be inclusive of
supply, packing, transportation, insurance,
and delivery up to site.
(Preferred Manufacturer/OEM:
LG/Sony/Samsung)
13 1 Supply, Installation, Testing and 217150.00 No.
Commissioning (SITC) of High-End Desktop
Workstation suitable for SCADA operations,
Client Workstation as per following
specifications: Intel® Core™ Intel Core i7-
10700, OS - Genuine Microsoft Windows®
10 Enterprise 64-bit, RAM - 16GB, Hard
Drives - 500 GB 7200RPM SATA3, Video
Adaptor - Integrated Intel UHD graphics
630 and NVIDIA Quadro P620 supporting
4 Monitors over HDMI/VGA, Network
Connection - 1 Gbit/sec or greater, Two(2)
PCI-Express Expansion Slots 2/4 USB,
CD/DVD ROM, USB Keyboard and Mouse,
UPS, associated cables etc complete as
required.HP Z2 SERIES WORKSTATION
(Preferred OEM/ Manufacturer-HP/ Dell/
Lenovo/ Siemens/ Schinder)
14 1 Supply, Installation, Testing and 252500.00 No.
Commissioning (SITC) of online 5 kVA UPS
with battery system designed to support
control room equipment load with minimum
1-hour backup, including high-quality
batteries, battery interconnections, and
charging system. The scope shall include all
necessary power and control cabling,
conduits, industrial-grade electrical fittings,
earthing, and accessories required for
reliable and safe operation. The system shall
be complete in all respects, installed, tested,
and commissioned as per approved drawings
and technical specifications, ensuring
uninterrupted operation of control room
instrumentation and automation systems.
The complete system rate shall inclusive of
supply, packing, transportation, insurance,
and delivery up to site. (with 5 year
warranty) (Make: Numeric/APC/Vertive)
15 225 GI raceways made of pre-galvanised sheet 1212.00 Rmt.
with thickness of 1.5mm for distributing LV
and ELV cabling on wall/ floor/ structure
installations. Can be combined with junction
boxes, backboxes for wiring devices, fixing
and coupler accessories. Consist of body &
cover. Cover fitted on to the body with
screws & can be opened easily if required.
Particularly suitable for applications
requiring EMC screening.protection level
should be lP 20 & lK 08. Standard length
should be 2.44/3 mtrs.Confirm to standard
22.Resistance to vertical load applied
through small surface area should be 1500 N
& Resistance to vertical load applied through
large surface area should be 3000 N. Linear
impedance in mili ohm /m of metal
raceways length 5 mili ohm/m.Race ways
should be supplied with complete accessories
i.e. fixing brackets & couplers for joining
raceways from the same manufacturer.
X 38mm mm Hot dip Gl Raceways with
Coupler and fixing bracket.
16 10 Junction boxes for direct access to cables at 2121.00 Nos.
the intersection of raceways. Supply
completely with base and cover plate (Lid)
with height adjustable feature from 65mm to
90 mm. Confirms to standard EN 60-670,EN
adjustable junction box, resistance to vertical
load applied over a small surface area should
be 500N & resistance to vertical load applied
over a large surface area should be 2000N.
Use junction box with fly over for direct
acess to cables at the intersection of floor
raceways while maintaining perfect
separation and 90 degree cross overs between
data and power cables.
17 350 Providing & laying approved make ISI 249.47 Rmt.
marked HDPE 6Kg / cm2 (Class-3) as per
IS:4984:1995 PE-80 to be erected at road
crossing on or floor as directed for laying of
cable. The pipes as following size of dia &
weight per 6 mtr.
(A) 63 mm inner Dia.
18 20 Supplying and erecting B class Galvanized 215.13 Mtr.
iron pipe having smooth finished bore of the
pipe on both ends erected nuts and bolts
along the pole / wall shaping the pipe as per
site requirement. Pipe dia as following.(B)
19 20 Supplying & erecting approved make SMC 476.72 Nos.
press moulded composite FRP. loop-in, loop-
out approx. 2mm thick box complete with
Bakelite connector strip 5way(3P+N+E),DIN
rail for mounting mob & hinged doors as
per requirement having locking
arrangements with mounting clamp with
nuts, bolts & washers suitable for erection on
pole with cable clamps & earth bolt of
following size of box. (C)150mm x 125mm x
20 555 Providing and erecting XLPE(IS:7098)(I)-88 339.36 Mtr.
ISI armoured cable multistrand / Solid
Copper conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing
trench / pipe at road crossing or floor of
following size of cables.
(A) 4 CoreX2.5 sq. mm Cu armoured cable
Preferred Make : KEI/Polycab/RR/Finolex
21 375 Providing and erecting XLPE(IS:7098)(I)-88 397.94 Mtr.
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench /
pipe at road crossing or floor of following
size of cables,
(D) 8 Core X 2.5 sq. mm Cu Flexible cable
Preferred Make : KEI/Polycab/RR/Finolex
21a 100 (G) 12 Core X 2.5 sq. mm Cu Flexible cable 524.19 Mtr.
Preferred Make : KEI/Polycab/RR/Finolex
22 348 SITC of CAT6 UTP 23AWG Solid: Per 43.43 Each.
[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
Preferred Make : Finolex/RR/D-
23 420 Providing and erecting Mains with ISI 70.70 Mtr.
marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with
heat resistant PVC insulated conforms to IS
694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel,
relays, power switchgears, motor starters &
control wiring) with required size of copper
lugs, nuts and bolts if required. (A) One wire
6.00 sq. mm (for earthing Connectivity)
Preferred Make : KEI/Polycab/RR/Finolex
24 397 SITC of O. F.Cable 06F Outdoor - 50.50 Mtr.
Armoured Unitube SM - HDPE Sheath
[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
Preferred Make : Finolex/D-link/Legrand
25 5 SITC of 14.2 mm dia 3 mtr long Earth 5992.33 Per set
electrode of High tensile steel electrode with
250 micron copper bonding & 1 bag of
Carbon fill Based environment friendly
backfill tested as per IEC 62561-7 in NABL
accredited Laboratory and suitable stainless
Steel double sided clamp. Eco Friendly rust
proof heavy duty weather proof Polyethylene
Earth Pit Chamber with following
dimensions :254 mm dia (top), 330 mm dia
(bottom) & 260 mm (height).
26 200 Providing , erecting , fabricating the M.S. 77.77 Kg.
structure as per requirement on site
incorporating proper size of M.S.
angles,square,round, flats, bars, channels,
sections complete with cutting, welding,
grinding & finishing duly painted with one
coat of red oxide with erection on site as per
direction of engineer in charge with
necessary grouting, cementing, plastering &
finishing complete.
Item Item Description Unit
27 1 1st Year Estimated Amount : Annual 457963.00 Yr.
Operation & Maintenance (O&M), Non-
Comprehensive Annual Maintenance
Contract (AMC) for supplied and installed
SCADA System equipment at dam, head
regulators, and remote monitoring stations.
The scope shall include Operation,
monitoring, and preventive maintenance of
all SCADA system components, Replacement
of consumables and materials, as required, as
per rate received in Schedule-C Unit Cost of
the bid documents, the AMC cost is including
of communication charges and data porting
including GPRS/SIM data transmission fees.
Deployment of One Diploma Engineer
(Instrumentation) and One ITI Tchnician in
2 Shift during Monsoon Season and
Remaining 8 month in Single Shift of
Diploma Engineer(Instrumentation), at the
Project Control Room for System operation,
maintenance and support. This Services to be
provided after final acceptance of the
SCADA system. The Per Year Rate shall
inclusive of all manpower, non-
comprehensive maintenance, communication
charges, travel, and related operational costs
for the SCADA system.
28 1 2nd Year Estimated Amount : Annual 503759.00 Yr.
Operation & Maintenance (O&M), Non-
Comprehensive Annual Maintenance
Contract (AMC) for supplied and installed
SCADA System equipment at dam, head
regulators, and remote monitoring stations.
The scope shall include Operation,
monitoring, and preventive maintenance of
all SCADA system components, Replacement
of consumables and materials, as required, as
per rate received in Schedule-C Unit Cost of
the bid documents, the AMC cost is including
of communication charges and data porting
including GPRS/SIM data transmission fees.
Deployment of One Diploma Engineer
(Instrumentation) and One ITI Tchnician in
2 Shift during Monsoon Season and
Remaining 8 month in Single Shift of
Diploma Engineer(Instrumentation) at the
Project Control Room for System operation,
maintenance and support. This Services to be
provided after final acceptance of the
SCADA system. The Per Year Rate shall
inclusive of all manpower, non-
comprehensive maintenance, communication
charges, travel, and related operational costs
for the SCADA system.
29 1 3rd Year Estimated Amount : Annual 554134.00 Yr.
Operation & Maintenance (O&M), Non-
Comprehensive Annual Maintenance
Contract (AMC) for supplied and installed
SCADA System equipment at dam, head
regulators, and remote monitoring stations.
The scope shall include Operation,
monitoring, and preventive maintenance of
all SCADA system components, Replacement
of consumables and materials, as required, as
per rate received in Schedule-C Unit Cost of
the bid documents, the AMC cost is including
of communication charges and data porting
including GPRS/SIM data transmission fees.
Deployment of One Diploma Engineer
(Instrumentation) and One ITI Tchnician in
2 Shift during Monsoon Season and
Remaining 8 month in Single Shift of
Diploma Engineer(Instrumentation) at the
Project Control Room for System operation,
maintenance and support. This Services to be
provided after final acceptance of the
SCADA system. The Per Year Rate shall
inclusive of all manpower, non-
comprehensive maintenance, communication
charges, travel, and related operational costs
for the SCADA system.
30 1 4th Year Estimated Amount : Annual 609547.00 Yr.
Operation & Maintenance (O&M), Non-
Comprehensive Annual Maintenance
Contract (AMC) for supplied and installed
SCADA System equipment at dam, head
regulators, and remote monitoring stations.
The scope shall include Operation,
monitoring, and preventive maintenance of
all SCADA system components, Replacement
of consumables and materials, as required, as
per rate received in Schedule-C Unit Cost of
the bid documents, the AMC cost is including
of communication charges and data porting
including GPRS/SIM data transmission fees.
Deployment of One Diploma Engineer
(Instrumentation) and One ITI Tchnician in
2 Shift during Monsoon Season and
Remaining 8 month in Single Shift of
Diploma Engineer(Instrumentation) at the
Project Control Room for System operation,
maintenance and support. This Services to be
provided after final acceptance of the
SCADA system. The Per Year Rate shall
inclusive of all manpower, non-
comprehensive maintenance, communication
charges, travel, and related operational costs
for the SCADA system.
31 1 5th Year Estimated Amount : Annual 670501.00 Yr.
Operation & Maintenance (O&M), Non-
Comprehensive Annual Maintenance
Contract (AMC) for supplied and installed
SCADA System equipment at dam, head
regulators, and remote monitoring stations.
The scope shall include Operation,
monitoring, and preventive maintenance of
all SCADA system components, Replacement
of consumables and materials, as required, as
per rate received in Schedule-C Unit Cost of
the bid documents, the AMC cost is including
of communication charges and data porting
including GPRS/SIM data transmission fees.
Deployment of One Diploma Engineer
(Instrumentation) and One ITI Tchnician in
2 Shift during Monsoon Season and
Remaining 8 month in Single Shift of
Diploma Engineer(Instrumentation) at the
Project Control Room for System operation,
maintenance and support. This Services to be
provided after final acceptance of the
SCADA system. The Per Year Rate shall
inclusive of all manpower, non-
comprehensive maintenance, communication
charges, travel, and related operational costs
for the SCADA system.
* All rates are exculusive of GST
I/We am/are willing to carry out the work at…………………….% above/below
percent(Shouldbe written in figures and words) of the estimated rate mentioned above.
Amount of my /our Quotation works out as under.
Estimated amount put to Quotation Estimated amount put to Quotation
Deduct……………% below Add……………….…% Above
In words …………………………….. In words……….………………………
1. The Contractor shall exhibit a board with detailed specification and details of work as directed by the
Engineer-In-Charge and as per GR No. MIS/102010/17(2)/k-1 of dtd. 29/01/2011 for which no extra payment
2. The labourcess will be deducted as per prevailing rules i.e. 1% of the work done.
3. GST and Income tax TDS will be deducted at a source while making payments of bills.
4. Rates quoted include clearance of site (prior commencement of work and at its close) in all respects and hold
good for work under all conditions, site, moisture, weather etc.
5. The quoted rates should be inclusive of cost of minor rectification work which may have to be done for
correcting the distoration caused during transportation of the gate components.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Bank Guarantee.pdf
NIT-11 of 2026-27 Panam Scada Work.pdf
SBD SCADA Panam Dam.pdf
BOQ Nprocure.pdf
Mendatory Documents(1).pdf
Mendatory Documents(2) Panam SCADA.pdf
Bank Guarantee.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .