Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-Finance JYOTIRMAY COLONY WARD NO 32 P O SILIGURI BAZAR P S BHAKTINAGAR SILIGURI JALPAIGURI 734005 | SILIGURI | JALPAIGURI | WEST BENGAL | 734005 | L1 | Accepted-Finance Accepted as L1
Bidder and financially
qualified | |
| 2 | L2₹1.9 L+₹8,300 (4.61%)Accepted-Finance 9M SREEDHAR ROY ROAD KOLKATA 7000 39 | KOLKATA | KOLKATA | WEST BENGAL | 700039 | L2 | Accepted-Finance Accepted as L2
Bidder and financially
qualified | |
| 3 | L3₹1.9 L+₹11,990 (6.67%)Rejected-Finance 159B M G ROAD HARIDEVPUR KOLKATA WEST BENGAL 700082 UDYAM WB 10 0018308 | KOLKATA | WEST BENGAL | 700082 | L3 | Rejected-Finance Rejected due to L3
bidder and
financially
disqualified |
| Sl No | Description | Qty | Unit | S. ENTERPRISE L2 | M/S KARMAKAR ENGINEERING COMPANY L1 | MONDAL ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. (Make: Approved by EIC) | 10 | Each | 1,265 ₹12,650 | 1,200 ₹12,000 Lowest | 1,300 ₹13,000 |
| 2.00 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in MS box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. (Approved by EIC) | 4 | Each | 595 ₹2,380 | 590 ₹2,360 Lowest | 600 ₹2,400 |
| 3.00 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/ recess with stainless steel chain & hammer assembly complete with glass and push button tec as required. (Approved by EIC) | 4 | Each | 540 ₹2,160 | 500 ₹2,000 Lowest | 550 ₹2,200 |
| 4.00 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities with mimic diagram for all area/ zone covered complete with all connections, interconnections as required: 4 Zone (Approved by EIC) | 1 | Each | 9,400 ₹9,400 Lowest | 9,500 ₹9,500 | 9,500 ₹9,500 |
| 5.00 | Supplying, installation, testing & commissioning response indicator on surface/ recess MS box having two LEDs metallic cover complete with all connections etc as required. (Approved by EIC) | 10 | Each | 210 ₹2,100 | 200 ₹2,000 Lowest | 220 ₹2,200 |
| 6.00 | Supplying and fixing 20 mm PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. | 370 | RM | 63 ₹23,310 | 60 ₹22,200 Lowest | 65 ₹24,050 |
| 7.00 | Supplying & laying of 1100 Volts Grade 2 x 1.5 sqmm FRLSH PVC Insulated, Copper Conductor Flexible Industrial Cables complete as required. (Make: Gloster/ Havells/ Polycab or equ as approved by EIC) | 370 | Mtr. | 148 ₹54,760 | 140 ₹51,800 Lowest | 150 ₹55,500 |
| 8.00 | Supply, Installation, Testing & Commissioning of ABC Powder type Fire Extinguisher (Stored Pressure): HSN code-84241000 duly ISI marked conforming to IS : 15683:2006 and complete in all respect as per direction of EIC. 09 Kg with ISI marked Mono Ammonium Phosphate base ABC powder conforming to IS : 14609 and pressurized with nitrogen gas. Suitable for operating between (-)30 deg.C to (+)55 deg.C. Fire rating - 3A & 34B (Make - Fireshield/ Minimax/Ceasefire or equiv. as per approved by EIC) | 6 | Each | 6,300 ₹37,800 | 6,000 ₹36,000 Lowest | 6,500 ₹39,000 |
| 9.00 | Supply, Installation, Testing & Commissioning of CO2 type Fire Extinguisher: HSN code-84241000. 4.5 Kg capacity with ISI marked CO2 type Fire Extinguisher squeeze grip type conforming to IS : 15683:2006 made from seamless cylinder conforming to IS:7285 duly approved by Chief controller of explosive, Nagpur, fitted with ISI marked controlled valve conforming to IS:3224, high pressure 1 mtr. long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket suitable for operating between (-) 30 deg.C to (+) 55 deg.C. Fire rating - 13B. (Make - Fireshield/ Minimax/Ceasefire or equiv. as per approved by EIC) | 4 | Each | 10,900 ₹43,600 | 10,500 ₹42,000 Lowest | 11,000 ₹44,000 |
Tender Value
Refer Docs
EMD Value
₹3,700
Closing Date
21 Jul 2025, 2:00 pmClosed
Assistant Engineer (Elec.)- in charge
Shilpa Bhavan, 31, Black Burn Lane, Kolkata-12
Supply and Installation of Fire detection system and fire extinguisher at Siliguri Commercial Park, under The WBSIDC Ltd.
2025_MSMET_878366_3
NIET 20 (Elec.) of 2025-26
Open Tender
FIRE FIGHTING ORG
Item Rate
30 days
Siliguri CP
Please refer Tender documents.
5 documents required · 5 mandatory
₹236
₹3,700
26 Aug 2025
14 Jul 2025
23 Jul 2025
15 Jul 2025
21 Jul 2025
15 Jul 2025
Amount
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. (Make: Approved by EIC)
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in MS box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. (Approved by EIC)
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/ recess with stainless steel chain & hammer assembly complete with glass and push button tec as required. (Approved by EIC)
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities with mimic diagram for all area/ zone covered complete with all connections, interconnections as required: 4 Zone (Approved by EIC)
Supplying, installation, testing & commissioning response indicator on surface/ recess MS box having two LEDs metallic cover complete with all connections etc as required. (Approved by EIC)
Supplying and fixing 20 mm PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
Supplying & laying of 1100 Volts Grade 2 x 1.5 sqmm FRLSH PVC Insulated, Copper Conductor Flexible Industrial Cables complete as required. (Make: Gloster/ Havells/ Polycab or equ as approved by EIC)
Supply, Installation, Testing & Commissioning of ABC Powder type Fire Extinguisher (Stored Pressure): HSN code-84241000 duly ISI marked conforming to IS : 15683:2006 and complete in all respect as per direction of EIC. 09 Kg with ISI marked Mono Ammonium Phosphate base ABC powder conforming to IS : 14609 and pressurized with nitrogen gas. Suitable for operating between (-)30 deg.C to (+)55 deg.C. Fire rating - 3A & 34B (Make - Fireshield/ Minimax/Ceasefire or equiv. as per approved by EIC)
Supply, Installation, Testing & Commissioning of CO2 type Fire Extinguisher: HSN code-84241000. 4.5 Kg capacity with ISI marked CO2 type Fire Extinguisher squeeze grip type conforming to IS : 15683:2006 made from seamless cylinder conforming to IS:7285 duly approved by Chief controller of explosive, Nagpur, fitted with ISI marked controlled valve conforming to IS:3224, high pressure 1 mtr. long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket suitable for operating between (-) 30 deg.C to (+) 55 deg.C. Fire rating - 13B. (Make - Fireshield/ Minimax/Ceasefire or equiv. as per approved by EIC)
S. ENTERPRISE (BID ID -6740010)
MONDAL ENTERPRISE (BID ID -6740004)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .