Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC ADMITTED | |
| 2 | L2₹16.4 L+₹1.2 L (7.57%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | Rejected-Technical | - | Rejected-Technical THE FIRM IS NOT ENLISTED FOR THE CATEGORY OF WORK |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
5 Nov 2019, 6:00 pmClosed
GE I CG PORBANDAR
GE I CG PORBANDAR, DHQ NO 1 COAST GUARD PORBANDAR
REPAIR MAINTENANCE OF INTERNAL ELECTRIFICATION MAINTENANCE OF ACs GYESERs WATER COOLERs ETC AT DHQ NO 15 OKHA UNDER GE I CG PORBANDAR
2019_MES_279035_1
8437
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
OKHA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE I CG PORBANDAR
₹27,000
Yes
5 Mar 2020
2 Sept 2019
6 Nov 2019
2 Sept 2019
5 Nov 2019
8 Oct 2019
Amount
SCHEDULE 'A'
Servicing and testing of AC of any make complete by cleaning cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing , oiling, greasing of blower motor, checking and removing any vibration, including top up of refrigerant and testing at site all as directed by Engineer-in-Charge. Note :- (a) Cost of any minor nature repair / items costing upto Rs 300/- per AC per Servicing including nuts, bolts,washers,screws, rubber mounting pads of compressor, labour for replacement of PCB, condensor, fan blade, blower, chord, remote etc and removing / refixing after repair of equipment is deemed to be included in the unit rate of this items. (b) Spare parts as detailed here-in-after shall be measured and paid as supply only. (c) Each Periodical Servicing of AC as ordered/required shall be measrued and paid.
Split type air conditioners of capacity 1.5 ton
Split type air conditioners of capacity 2.0 ton
Window type AC 1.5 ton
M&L Detecting the cause of leakage in any type/capacity of 1.5 tonne AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity as directed by EIC including testing for smooth functioning complete all as specified and as directed. Notes :- (i) Dismantling of unserviceable compressor , cost of refrigarent gas and re-installation of serviceable compressor after repairing are deemed to be included in the quoted rates .
All as per item No 2.00 above but of capacity 2 ton .
M&L refrigerant tubing for suction /discharge including insulation tubing all as per site requirement and as directed by Engr-in-Charge.
Supply only spare part for Split type AC cap 1.5/2.0 TR of make as per AC of Item No. 1
Compressor Heremetically sealed Rotary Type for 1.5 TR AC
Compressor Heremetically sealed Rotary Type for 2.0 TR AC
Blower Motor / condensor Motor for 1.5/2.0 TR AC
Outdoor Unit without compressor for 1.5/2.0 TR AC
PCB suitable for existing model of AC's
Condensor suitable for existing model of AC's
Fan blade suitable for existing model of AC's
Remote control for operation of indoor unit of split AC suitable for existing model of AC's
S&F in replacement hand shut valve suction for split AC 1.5/2 Tonne complete all as specified and as directed.
Ditto- but hand shut valve discharge
S&F In replacement of condensing coil (copper) of indoor split type AC 1.5/2.0 Tonne capacity complete all as per existing make and model
M&L Detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of capacity 40/80 Litre complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Supply only Compressor shall be measured and paid separately under respective items of Sch "A"
S&F Repair of thermostat switch suitable for existing water cooler any make and capacity complete all as specified and as directed.
M&L In replacement of running capacitor 25 mfd or nearest cap suitable for existing size & make of water cooler complete all as specified and as directed.
Dismantling of old defective condenser fan motor of water cooler of any make and capacity and replace with new of same capacity and testing the same as approved by Engineer-in-Charge including replacement of shaft/ bush etc complete all as specified and as directed.
S&F In replacement of fan blade of condenser motor of any make and capacity of water cooler complete all as specified and as directed.
S&F Bib tap Cast copper alloy, 15 mm, Push type, chromium plated for water cooler.
S&F PVC Connection with brass unions at both ends with brass nuts, suitable for fixing to 15 mm dia GI Pipe.
S&F PVC Float valve with epoxy coated aluminium arm , with PVC polythene ball suitable for water coolers.
S&F 32mm dia PVC spiral drain out pipe, as per existing by providing necessary GI Clamps nuts bolts etc.
Taking down carefully burnt out aluminium/copper circuit wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc to be measured and paid for seprately) removing materials to store for reuse and making good to the disturbed surfaces of walls ceilings and floors etc complete all as spd and directed by Engineer-in-Charge.
M&L Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable, drawn through and including PVC conduit ISI Marked with wall thickness not less then 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable as earth continuity wire with modular metal flush box complete all as spd and directed.
One light/fan point controlled by one, one way switch
One bell point controlled by push button on the same board with other switch.
One 5 pin socket outlet 5/6 amps on the same board.
One 5 pin socket oulet 5/6 amps on independent board..
M&L Point wiring complete with stranded copper conductor 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable, drawn through and including PVC conduit heavy duty grade ISI marked 20 mm dia (external) ISI Marked with wall thickness not less then 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable as earth continuity wire with modular metal flush box complete all as spd and directed. Make of wire: Finolex/RR Cables/Havells/Anchor
M&L Sub-mainwiring with two single core 1.5 sq mm stranded copper conductor PVC insulated and unsheathed cable ISI marked in existing ,concealed, cundit alongwith 1.5 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete including taking down of worn old wiring, complete all as specified and directed by Engr-in-Charge. Note:Cost of Cutting, drilling, cheasling and making good of wall/ ceiling surface included in quoted unit rate.
M&L Sub main wiring with two single core 2.5 sq mm stranded copper conductor PVC insulated and unsheathed cable ISI marked in existing conduit concealed in wall concealed sub main wiring alongwith including 2.5 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete including taking down of worn old wiring , complete all as specified and directed by Engr-in-Charge. Note:Cost of Cutting, drilling, wall/ ceiling surface included in quoted unit rate.
Supply and fix following electrical accessories for new point wiring . Make :Havells (Crabtree)/Anchor (Roma)
Modular switch 1 way 6 Amp, 1 module ISI marked.
Modular switch 1 way 16 Amp, 1 module ISI marked.
Modular socket 2-in-1 6A-2/3 pin combination, 2 module, ISI marked.
Modular socket 2-in-1 6A/16A-6 pin combinationd, 2 module, ISI marked
Supply and fix following electrical accessories in repairs . Make :Havells/Anchor.
Socket outlet 3 pin 15 Amp flush type, ISI marked.
Socket outlet, 2 in 1, 3 pin, 5 and 15 Amp flush type
Socket outlet 3 pin, 5A, flush type
Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal
Switch socket combination 5 in 1, 5A/16Amp flush type universal. Make of Modular accessories:
step type fan regulator, 120W - 2 module
S&F metal flush box 3 module including modular white cover plate with frame all as specified, in repair. Make :Havells (Crabtree)/Anchor (Roma)
S&F metal flush box 8 module including modular white cover plate with frame all as specified, in repair. Make :Havells (Crabtree)/Anchor (Roma)
S&F metal flush box 12 module including modular white cover plate with frame all as specified, in repair. Make :Havells (Crabtree)/Anchor (Roma)
S&F in replacement Casing and caping of size 25mmX16mm , complete all as specified and directed by Engr-in-Charge.
Taking down ceiling fans/ Exhaust fan, complete servicing of fan motor including replacement of minor worn out parts and hanging of ceiling fan/fixing of exhaust fan in situ all as specified and directed. Note: (i) Minor spare parts like copacitor, flaxible cable sofeting pings, rubber bushes for hanging etc, as required costing upto Rs 50/- per fan shall be deemed to include in the unit rate quoted. (ii) Rewinding/repair of fan motor will be measured and paid seprately.
M & L Rewinding of burnt winding of fan rotar, of sweep 1200 mm, with existign wire gauge of copper insulated wire, all as directed by the Engineer-in-charge, including cutting of burnt winding of rotar winding and reassembling vide item No 29.00 above, all as directed by Engineer-in-Charge.
All as per item No 30 above but for exhaust fan.
Supply only spare parts of Fan/Exhaust fan of following rating all as spd and directed by Engineer-in-Charge.
Capacitor (a)2.5 MFD ISI marked.
Ball bearing 6203 of make TATA, SKF.
Dismantling electric/water connection and taking down of storage type water heater,servicing,cleaning of inner tank etc.at site.and replacement of burnt out parts etc. and refixing in situ all as specified and directed. Note- wornout parts shall be measured as seperatly.
Supply only spare parts for Gyser
(a) Copper Heating element 1.5 KW with rubber gasket .
(b) Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked.
(c) Hot/Cold water connection pipe 450 mm length.
(e) 3 core 1.5 sqmm PVC insulated cable 1.5 m long with 3 pin 15 Amp plug.
(f) Gyser Apparatus assembly made of copper.
Supply and fix ceiling rose surface type bakelite / PVC three terminal 65 x 50mm in repair.
Supply and fix LED tube light fitting 20 Watt with aluminium extrusion housing, energy effient T5, up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal, in repair. Make: Bajaj BLTRU 20 W WH VIVA/Philips BN108C-LED_20 S-6500/OSRAM LUXPOWER BATTEN 19WL 840
Supply and fix surface mounted LED 1x9 watt with driver complete all as specified and directed, in repair . Make : Wipro (Moon LED)/Philips (Sleek surface Downlight)/Havells
Supply and fix in repair Bell Multi Music type AC 230 V
Supply and fix LED batten 10 Watt including electrical connections fixed complete in repair as directed. Make : Wipro (Trim LED Neo)/Havells/Philips
M&L Pipe earthing by drilling bore complete with galvanised steel pipe electrode, 40 mm bore, medium grade, 3.0 metres length, not less than 2.75 metres below ground level connected with earthing lead of 6 sqmm bare aluminium wire conductor drawn in to and including PVC conduit medium grade, filling of bore with charcoal dust and salt and earth enhance gel, and connected to the earth test point all as specified and directed in electrical plate no.2 of SSR Part-I including provision of earth pit all as specified. Note: 1. cost of earth wire and PVC conduit for protection of earth conductor deemed to be included in unit rate up to 7.5 meter 2. Result should be less than 2 Ohms.
S&F MCB DB SPN 240 Volts 12 Way thermoplastic circuit breaker enclosure IP 65 in repair and including :- (i) MCB SPN 63A -01 Nos (ii) MCB SPN 16 A -04 Nos (iii) MCB SPN 6A -06 Nos Make : MCB:Legrand/ABB/Schneider DB : Hensel/Hager/Neptune
S&F MCB DB SPN 240 Volts 08 way thermoplastic circuit breaker enclosure IP 65 in repair and including:- (i) MCB SPN 25A -01 Nos (ii) MCB SPN 16 A -02 Nos (iii) MCB SPN 6A -04Nos Make : MCB:Legrand/ABB/Schneider DB : Hensel/Hager/Neptune
ABR Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .