Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance A 5 ACHARYA NIKETAN PATPARGANJ MAYUR VIHAR PHASE 1 DELHI 1100091 | 1100091 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical As per recommendation |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹22.6 L
EMD Value
₹45,000
Closing Date
6 Dec 2019, 6:55 pmClosed
Senior Manager (Contracts)
Contracts and Procurement Division, Uri-II Power Station, NHPC Ltd., Nowpora, Tehsil-Uri, Distt.-Baramulla, J and K
Supply and installation of Cable trays and dismantling and laying of Cables on the trays in Main Access Tunnel (MAT) of Uri-II Power House
2019_NHPC_519048_1
NH/Uri-II/CnP/19-20/26
Open Tender
Electrical Works
Works
60 days
Nowpora
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
NHPC Limited
₹45,000
Yes
27 Apr 2020
16 Nov 2019
12 Dec 2019
16 Nov 2019
6 Dec 2019
16 Nov 2019
Amount
Dismantling of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Single core 240 sq.mm size unarmored cable laid on the ground/tray/hanged on MAT wall as required and rolled the same without cutting/ damaging the cables etc.
Dismantling of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3½ core 50 sq. mm. size unarmored cable laid on the ground/tray/hanged on MAT wall as required and rolled the same without cutting/ damaging the cables etc.
Dismantling of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 2 core 50 sq. mm. size unarmored cable laid on the ground/tray/hanged on MAT wall as required and rolled the same without cutting/ damaging the cables etc.
Dismantling of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3½ core 16 sq. mm. size size unarmored cable laid on the ground/tray/hanged on MAT wall as required and rolled the same without cutting/ damaging the cables etc.
Supply and Installing 300 mm width X 50 mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray with plane cover from the top and cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, nuts- bolts, washer etc. as required
Supply and installation of G.I single strut channel (C- Channel) of size 41mm width x 41mm depth and 2.5mm thickness of length 1 mtr. to bear load & support the cable & cable tray and fixing it vertical with the wall with G.I. C-clamps, anker bolts, washer etc. as required.
Supply and installation of G.I single strut channel (C- Channel) i.e. Horizontal cantilever arm of size 41mm width x 41mm depth and 2.5mm thickness of length 350mm to support the cable tray and fixing it perpendicular on vertical mounted c-channel with its welded base plate of size 150mm x 45mm with two 14mm dia hole for fixing nuts-bolts, spring washers etc.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Single core 240 sq.mm size on the cable tray with suitable size flat iron strip/saddle for fixing as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3½ core 50 sq. mm. size on the cable tray with suitable size flat iron strip/saddle for fixing as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 2 core 50 sq. mm. size on the cable tray with suitable size flat iron strip/saddle for fixing as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3½ core 16 sq. mm. size on the cable tray with suitable size flat iron strip/saddle for fixing as required.
Laying of 1.1kV grade of size 2 X 2.5 sq. mm of FRLS PVC insulated copper conductor in the existing MS pipe for PA system with fixed/laid on cable tray with required saddle, nuts & bolts as required
Supplying and fixing of 20 mm sizes of PVC conduit along with accessories on the cable tray as required
Laying of 10 pair of 0.5 sq. mm of telephone cable in the existing PVC pipe fixed/laid on cable tray with required saddle, nuts & bolts as required
Asif Iqbal
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .