| 1 | L1₹24.6 LAccepted-AOC SHOP NO 1 KARGI CHOWK HARIDWAR BY PASS DEHRADUN UTTARAKHAND | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹26.1 L+₹1.5 L (6.13%)Rejected-AOC | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹29.9 L+₹5.3 L (21.5%)Rejected-AOC | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹27.3 L
EMD Value
₹54,500
Closing Date
8 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
PROVISION OF CERTAIN REVENUR WORKS AND MINOR WORKS AT IRDE AND DEAL UNDER GE (I) R N D DEHRADUN
2021_MES_495970_1
GE(I)RND/9101/E8/21-22
Open Tender
Civil Works
Item Rate
180 days
DEHRADUN
PROVISION OF CERTAIN REVENUR WORKS AND MINOR WORKS AT IRDE AND DEAL UNDER GE (I) R N D DEHRADUN
6 documents required · 6 mandatory
₹500
Yes
GE I R N D DEHRADUN
₹54,500
Yes
24 Jan 2022
18 Dec 2021
10 Jan 2022
18 Dec 2021
8 Jan 2022
25 Dec 2021
18 Dec 2021 - 25 Dec 2021
60 days
Amount
Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
Demolition of reinforced cement concrete in any position and any description including cutting of reinforcement bars to facilitate demolition complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and directed.
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards / slabs / blankets, any thickness including cover fillet complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for laying of cable etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
M&L for dry sand cushioning for UG cable in trenches including spreading levelling and hand paning and consolidating complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M & L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M & L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M & L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M & L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Cutting holes into or through brick walls built in cement mortar and making good the same in cement concrete 1:2:4 type B-0 or cement mortar 1:3 as required, superficial area of cutting not exc. 150 Sqcm complete all as specified and directed.
M & L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in fair finished surface of concrete complete all as specified and directed.
M & L for form work to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, opening in concrete wall, sides of RCC slab, RCC / PCC bends in walls or similar work thickness exc 5cm but not exc. 10cm wide in fair finished surfaces complete all as specified and directed.
M & L for Ist class hard wood (SAL) plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S & F of 32 mm thick factory made flush shutter, solid core construction with block board core and plywood face panels commercial type on both faces including teakwood lipping 6 mm thick fixed with nails complete all as specified and directed.
S & F of 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S & F of 250 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy complete all as specified and directed.
S & F of 150 mm long anodised aluminium handle, cast type complete all as specified and directed.
S & F of 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 8 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F of rolled mild steel sections as in main and cross beams, hip and jack rafter, purlins where connected to common rafters, running rails, guides for sliding doors fixed with angle cleat and other connecting plates conforming to Fe-290 (Gde E- 165) complete all as specified and directed.
S&F Roof trusses (framed) Fe 410-W (Gde -E-250) quality-A, trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle channel or flat sections) including distance pieces cleats etc. complete all as specified and directed..
S & F of mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed ends to be fitted with washer and one hexagonal or square nut, not exc. 5 cm long and 11 to 15 mm dia of neck complete all as specified and directed.
S & F of steel windows with glazed with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed
S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F of anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F of anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
M&L for suspended false ceiling system using chicago metallic (E grid)exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length)with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant termite resistant , fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture complete all as directed.
S&F of 18 mm thick prelaminated both side cellulka PVC board anti-terminite & moisture proof for cubical tables, cupboard, service tables haivng drawer, office Almirah, partition etc. covering with 10 mm glass on top from front, sides including all accessories like sliding drawer, handle , hinges , cather's peg stay , locks etc complete all as specified and directed.
S&F in repair polyster coloured vertical venetian blind mounted on doors / windows with aluminium hanging channel with sliding wheel / rope including all necessary fittings as per manufacture instructions and complete all as specified and directed.
S & F of Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed . NOTE:- Corrugated shape of sheet shall be approved by GE
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
M & L for 15 – 18 mm thick machine cut Kota stone slab as in flooring with and including 20 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish complete all as specified and directed.
M & L for 15 – 18 mm thick machine cut Kota stone slab as in risers of steps, skirting, dado and pillar with and including 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough suitable for laying wall tileslaid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-1, using 20 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm thick joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed.
M & L for providing 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor complete all as specified and directed.
M & L for providing 50 mm thick cement concrete 1:2:4 type B-1 (using 20 mm thick graded stone aggregate) as in sub base finished complete all as specified and directed.
M&L PVC Linoleum 3.20/4.5 mm thick, plain coloured, laid dry in floors including stretching, cutting and fitting and laid with approved rubber based adhesive in floors incl removing of old tiles/sheets etc. complete all as specified and directed.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth (without using extra cement)complete all as specified and directed.
M & L for 15 mm thick rendering in two layers on fair faces of brick work or concrete surfaces first layers 10 mm thick with cement mortar 1:6 on fair faces of brick work or concrete surfaces and second layers 5 mm thick with cement mortar 1:4 with mixing of water proofing compound as per manufacturer’s instructions complete all as specified and directed.
Supply only water proofing compound (Powder) complete all as specified.
M & L for 10 mm thick rendering on fair faces of brick work or concrete surfaces of wall/ceiling with cement mortar 1:3 finished even and smooth (without using extra cement)complete all as specified and directed.
M&L for 5.5 mm thick sheet glass ordinary quality in panes exc 0.50 sqm each fixed with & including rubber gasket in aluminium frame work complete all as specified and directed.
S & F of 4 mm thick designed glass, pin head type and glazing with oil putty or fixed with beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
M & L for complete removal of old finishes from walls by scrapping, rubbing down, with sand paper to have even and smooth surfaces and applying two coats of oil bound distemper over one coat of primer complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M&L for applying of Birla/JK white wall putty approx 3 mm thick as per manufacturer's instruction on existing prepared surface and make the surface smooth by rubbing with sand papers etc and applying two coats of oil emulsion distemper over a coat of primer after prepration of newly plastered surfaces of walls complete all as specified and directed.
M&L for applying of Birla/JK white wall putty on ceiling approx 3 mm thick as per manufacturer's instruction on existing prepared surface and make the surface smooth by rubbing with sand papers etc and applying two coats of oil emulsion distemper over a coat of primer after prepration of newly plastered surfaces of walls complete all as specified and directed.
M & L for preparation of new or previously untreated wooden surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
S&F anodised aluminium door,windows ,ventilators shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc.complete all as specified and directed.
M&L 12 mm thick pre-laminated particle board, interior grade, pre-laminated both sides with decorative choice laminations complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.all as specified and directed by Engr-In-Charge.
.M&L for point wiring for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified and directed by Engr-In-Charge.Make Of Cable: Havells/Polycab/Gloster.
All as per item No 2 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete. Make of cable and conduit: Havells/ Polycab/Gloster.
S&F Modular switch, single pole one way 16 amp complete all as specified by Engineer-In-Charge. Make: Legrand/Anchor Penta/Havells
S&F Modular socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete all as specified by Engineer-In-Charge. Make: Legrand/Anchor Penta/Havells
Supply and fix new single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one single pole MCB 20/32 Amp complete all as directed and specifed by Engr in charge.Make: Legrand/Indoasian/Havells
Supply and fix LAN/Internet socket - RJ11 single module complete in all respect all as specified and directed by Engr-In-Charge. Make; Indoasian Cat Pt No.800130 or equivalent in Havells/Legrand.
S&F 25 mm dia rigid non metallic PVC conduit medium grade ISI marked ivory colour along with accessories in recess including cutting the wall and making good disturbed surfaces complete all as specified and directed.
Supply and fixing exhaust fan made of sturdy engineering plastic copper windng of 250 mm sweep single phase with blade & louver shutter complete,volatge 230V,50 Hz, RPM 1200 including Provision of 3 core PVC insulated sheathed 1100 volt grade flexible cable with stranded copper conductor of size not less than 0.5 sqmm, from ceiling rose to fan including making suitable size of hole on existing wall with neccesssry PCC work complete make suitable size of holl including making good the distrubed wall/roof/ceiling etc complete, all as specified and as directed by Engr-in-Charge.Make : Bajaj MAXIMA DX ( Whilte) or equivelant make in Usha/Crompton
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1 Sq mm (Nominal area) and connected to main earth dolly complete all as specified and directed by Engr-In-Charge.Make Of Cable: Havells/Polycab/Gloster.
(a) One light point controlled by one switch.
(b) One fan point controlled by one switch
(a) One 5 pin switch socket outlet, 5/6 Amps by same board.
(b) One 5 pin switch socket outlet, 5/6 Amps by independent board
S&F Modular switch, single pole one way 6 amp complete all as specified by Engineer-In-Charge. Make: Legrand/L&T/Havells
S&F ceiling rose 3 plates polycarbonate body complete all as specified by Engineer-In-Charge.Make: Legrand/L&T/Havells
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FR multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal sizes:-
(a) 2x2.5 sqmm + 1x1.5 sqmm earth wire in conduit of suitable size.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor wall/ ceiling/concealed surface etc complete all as specified and directed.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed.
S&F MCB distribution board SPN, 240 volts, 2 ways ,powder coated, CRCA steel sheet constructed as per IS : 8623-1 &3, degree of protection IP 42- IK-09 with glazed double door with two incoming and four outgoing terminals, recess mounted, without having any copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. Make: L&T Cat Pt No. DBSPN006GD or equivalent in Legrand /Schneider as approved
S & F MCB SPN 240 volts 'C' Curve suitable for fixing in MCB DB of capacity 25 amps complete all as specified and directed.Make - L&T cat ref no BB20250C or equivalent in Legrand/Schneider as approved.
S&F MCB distribution board TPN, 415 volts, 4 ways ,powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. Make: Legrand Cat Pt No. 4025 05 or equivalent in Havells/L&T/Schneider/ IndoAsian as approved
S&F MCB distribution board SPN, 240 volts, 8 ways ,powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. Make: Legrand Cat Pt No. 4025 05 or equivalent in Havells/L&T/Schneider/ IndoAsian as approved
Supply and fixing MCB/Isolator C Curve 4P, HSN code 8536, 415 volts suitable for fixing in DB of capacity 63 Amps complete, all as specified.
S & F in replacement of unserviceable MCB SPN 240 volts 'C' Curve suitable for fixing in MCB DB of capacity 63 amps complete all as specified and directed.Make - IndoAsian cat ref no 811144/46/48/49/50/51 or equivalent in Hager or Schneider as approved.
S & F in replacement of unserviceable MCB SP 240 volts 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete, all as specified.Make -IndoAsian cat ref no 811122/24/26/27/28/29 or equivalent in Hager or Schneider as approved.
Supply& Fixing in repairs MCCB 400 Amps 4 pole 35/36 KA with adjustable thermal and fixed magnetic setting .Make: Legrand/siemence/shiendelar/Havells
S&F LED 20W complete batten fitting, efficacy: 100 lumen/watt with all as accessories complete all as specified and directed by Engr-In-Charge. Make: LCTLN-20-CDL or equivalent in Havells/Bajaj.
S&F bulkhead fitting with integrated LED bulk head fitting 600 lumens, 6000 K comprises of pressure die cast housing, acrylic diffuser and frame IP 65 protection, IK-07 etc including connection complete all as directed.Make- LBHP-10-CDL of C&G or equivalent in Havells/Phillips as approved.
S&F exhaust fans AC single phase 240V of size 300 mm sweep with louver complete alongwith making circular holes of suitable size suitable for mounting the exhaust fans and making the disturbed surfaces good complete all as speified and directed by Engr-In-Charge.Make: Havells/C&G/Bajaj
Supplying, fixing & testing in replacement UNSV recess mounting in built ,36 Watts,2'x2' LED ceiling light fitting with slim line extruded aluminium/ CRCA body, opal acrylic diffuser, electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- C&G Cat Pt No LCTLRNE-36-FO-CDL or equivalent in Phillips/Havells as approved.
S&F in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole and neutral MCB 20 amp,240Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 16/20 amp as required. Make of MCB SP 16/20 Amp- Cat Pt No. 811126/27 of IndoAsian orequivalent in Legrand/Seimens/Schneider Make of SPN DB with MCB 20Amp - CAt PT No 811956 of Indo Asian or equivalent in Legrand/Schneider as approved. .
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed
Supply and fixing ceiling fan 1200mm sweep single phase complete including with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and provision of 3 core PVC insulated sheathed 1100 volt grade flexible cable with stranded copper conductor of size not less than 0.5 sqmm and one meter long from ceiling rose to fan all as specified and as directed by Engr-in-Charge. MAKE :-Havells Pacer 3 Blade
M&L for 250 Amp, 50 Hz Pole, 415v, MCCB, ISI marked of breaking capacity /3536 KA for AC 440 volts three Phase four wire supply including suitable size of distribution box factory made to be mounted on wall for fixing of MCCB with the provision of incoming and out going cable and testing complete all as specified and as directed at site by the Enr-in-Charge
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, LT 1100 volts grade heavy duty with aluminium stranded conductor of cross section area 95 Sqmm 3.5 core complete all as specified and directed at site.
Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area of size 35 sqmm 3.5 core of cables laid in trenches/fixed on pole/wall / passed through pipe complete all as specified and directed by Engineer-in-Charge. Make:Havells/CCI/ICL/GLOSTER/Incab/Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and brick protection shall be measured and paid separately )
M&L for laying GI tubing light grade 40mm dia with all fittings & GI MS clamps of 50 x 6 mm incl nuts and washers for fixing of GI pipe complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
M/S DHYANI CONSTRUCTION CO.
M/S P K ARORA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .