Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹79.8 L+₹6.9 L (9.54%)Rejected-Finance 37 B MODEL TOWN NEAR HARI MANDIR BAREILLY UP 243001 | BAREILLY | UTTAR PRADESH | 243001 | L2 | Rejected-Finance not being L1 | |
| 3 | L3₹83.8 L+₹11.0 L (15.1%)Rejected-Finance 232 1 D SHIVLOK KANKARKHERA DISTT MEERUT UP PIN 250001 | MEERUT | MEERUT | UP | 250001 | L3 | Rejected-Finance not being L1 |
Tender Value
₹92 L
EMD Value
₹1.6 L
Closing Date
9 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF BAREILLY
HQ CWE AF BAREILLY PIN 243002
PROVN OF EXTENSION OF EXISTING GROUND RUN POINT AND CONSTRUCTION OF SOUND PROOF ROOM AT ALPHA SQN AT AF STATION BAREILLY
2023_MES_625638_1
81367/E8
Open Tender
Civil Works
Lump-sum
270 days
AF Stn Bareilly
As per NIT
8 documents required · 8 mandatory
₹1,000
GE AF BAREILLY
₹1.6 L
Yes
24 Jan 2024
30 Oct 2023
11 Dec 2023
30 Oct 2023
9 Dec 2023
27 Nov 2023
30 Oct 2023 - 15 Nov 2023
Amount
NOTE: Schedule ‘A’ Part - I :-To be quoted by the tenderer as Lump Sum in the BOQ At Srl No 02 hereinafter:-
Lump sum price worked out by the Contractor for “BUILDING WORK (BLOCK OF TESTING ROOM ) Complete all as specified and shown on drgs as listed in Schedule ‘A’ Part-I at Srl Page No 19 item No 01.
Lump sum price worked out by the Contractor for “BUILDING WORK (BLOCK OF AIR CREW READINESS ROOM) Complete all as specified and shown on drgs as listed in Schedule ‘A’ Part-I at Srl Page No 19 Item No 02.
Total amount of SCHEDULE 'A' PART-IIA (SOUND PROOF TESTING ROOM) (For details see Item No. 01 to 6 of Schedule 'A' Part-II A in PDF folder)
Total amount of SCHEDULE 'A' PART-IIIA (RENOVATION OF EXISTING GRP STORAGE SHED) (For details see Item No. 01 to 18 of Schedule 'A' Part-III A in PDF folder)
Total amount of SCHEDULE 'A' PART-IV-A (INTERNAL ELECTRIFICATION) (For details see Item No. 01 to 23 of Schedule 'A' Part-IV-A in PDF folder)
Total amount of SCHEDULE 'A' PART-V (INTERNAL WATER SUPPLY) (For details see Item No. 01 TO 11 of Schedule 'A' Part-V- in PDF folder)
Total amount of SCHEDULE 'A' PART-VI-A (EXTERNAL ELECTRIFICATION) (For details see Item No. 01 to 10 of Schedule 'A' Part-VI-A in PDF folder)
Total amount of SCHEDULE 'A' PART-VII-A (AIR CONDITIONING) (For details see Item No. 01 of Schedule 'A' Part-VII-A in PDF folder)
Total amount of SCHEDULE 'A' PART-VIII (ROAD AND HARD STANDING ) (For details see Item No. 01 to11 of Schedule 'A' Part-VIII in PDF folder)
Total amount of SCHEDULE 'A' PART-IX (SITE CLEARANCE AND DEVELOPMENT ) (For details see Item No. 01 to 02 of Schedule 'A' Part-IX in PDF folder)
MISCELLANEOUS ITEMS COVERED UNDER RESPECTIVE SCHEDULE 'A 'PART-IIB TO IVB AND VIB TO VIIB AS UNDER (TO BE QUOTED BY THE TENDERER)
SCHEDULE 'A' PART-IIB (SOUND PROOF TESTING ROOM)
S&F yellow accoustic glass wool roll of thickness 40mm laid between wall and ceillings and boards complete all as spd and dirceted.
S&F 10mm thick tinted toughened glass (tint as aproved by GE) exc 0.50 sqm each pane , all as per drg complete all as directed at site. Note:- The glass panes shall have seamless joint and the space in between shall be hermetically & entrapped air shall be dehydrated with drying agent.quoted rates shall be inclusive of cost of rubber gasket and all necessary fittings .
S&F 10mm thick toughened float glass exc 0.50 sqm each pane , all as per drg complete all as directed at site. Note:- The glass panes shall have seamless joint ans the space in between shall be hermetically & entrapped air shall be dehydrated with drying agent.
S&F Aluminium section powder coated of colour as approved doors (two panels) with frame and shutters partly with 5 mm thick reflective glass and partly closed with 5 mm thick aluminium composite panel (alco panel) fixed with aluminium chamfered clip section no 4407 of aluminium door sections all as per Drg No as under : (a) Frame 100x40x2mm section No-2420 (b) Shutter style 85x44.45x1.7mm thick section 4546 (i) Top rail 14.30x44.45x1.7mm thick section 4553 (ii) Middle rail 83.50x44.45x1.7mm thick section 4565 (iii) Bottom rail 114.30x44.45x1.7mm thick section 4529 (iv) glazing clip powder coated 0.7mm thick section no 4407 (v) Handle stainless steel 300mm long as approved (vi) Tower bolt powder coated 9.90 mm dia & 200mm long section No 4002 (vii) Mortice lock 100mm 7 leverof Godrej make (viii) Hold fast aluminium 100 mm long (ix) Rubber gasket white PVC (x) Namda rope to be fixed in the styles's groove for proper air tightness.(xi) Note : Bottom panel shall be with aluminium composit panel & top panel with glass complete all as specified and directed.
SCHEDULE 'A' PART-IIIB (RENOVATION OF EXISTING GRP STORAGE SHED)
S&F vertical type venetian blinds of approved colour using 100mm wide fabric blinds including operation chords, threads, counter nut, connection chain, necessary fittings complete all as directed .
M & L for Construction of Septic Tank for 25 users including necessary earth work in excavation in any type of soil , plain cement concrete 1:2:4 type B-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brick work in cement mortar 1:4 , ,reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast man hole cover slab having 8 mm dia TMT bar reinforcemement @ 75 mm c/c & 6 mm thick mild steel plate embedded all around of cover slab , 15 mm thick plaster in cement sand mortar in 1:4 on wall, vent shaft, sludge chamber , form work to sides and soffits, 150 mm dia SGSW pipe of type SP 1as per IS as inlet & out let pipes up to 3 m from outer face of wall, CI vent pipe, sludge chamber, RCC baffle wall, returning filling & removal etc, complete all as shown on drawings & as specified.
M & L for Construction of Soakage well for 2.40 m dia( internal dia ) & 3.00 m (effective depth ) including necessary excavation in earth work in any type of soil , plain cement concrete 1:3:6 type C-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brick work in cement mortar 1:4 in walls & honey combed brick wall , reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast cover slab having 8 mm dia TMT bar reinforced , plain cement concrete band and dwarf wall, form work to sides and soffits of RCC slab & filling with brick bats loose filling complete complete all as specified and shown in drawings.
SCHEDULE 'A' PART-IV-B ( INTERNAL ELECTRIFICATION)
S&F heavy duty PVC wall mount fan 450 mm sweep 1440 rpm 4 speed control with regulator, single phase 230 volts AC 50 Hz consisting of powerful circulation motor with spiral guard desing ensures high air thrust high torque gear box with safety clutch broad blade profile for low noise resettable thermal overloaded protector oscillating mechanism including making electric connection using three core flexible twisted copper conductor of size 23/0.0076 complete all as specified and directed .
SCHEDULE 'A' PART-VIB(EXTERNAL ELECTRIFICATION)
M&L Horizontal boring under Road pavement hard standing complete for inserting GI pipe light grade of size 80/100 mm dia complete all as specified and directed Note : GI pipe shall be measured and paid separately
SCHEDULE 'A' PART-VIIB (AIR CONDITIONING)
Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 140 V to 280 v with output voltage satbilized at 230 V with accuracy +/- 2.5% and speed of correction 8 volts per second of capacity 4 KVA complete all as specified and directed.
MOHINDER SINGH AND SONS
Shikhar ji Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .