Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC Awarded Value |
| 2 | L2₹1.3 Cr+₹4.8 L (4.01%)Rejected-Finance | ₹1.3 Cr+₹4.8 L (4.01%) | L2 | Rejected-Finance L2 bidder |
Tender Value
₹1.3 Cr
EMD Value
₹50,000
Closing Date
16 Jul 2019, 4:00 pmClosed
General Manager
KITCO Ltd P.B.No 4407 Puthiya Road NH Bypass Vennala Kochi 682028
Electrical works for the Construction of Model Residential School at Thirunelli
2019_KITCO_285639_1
STDD/KITCO/EL/03/2019
Open Tender
Electrical Works
Item Rate
240 days
Thirunelli
As per NIT
6 documents required · 6 mandatory
₹5,900
Yes
KITCO Ltd
₹50,000
Yes
24 Mar 2021
9 Jul 2019
19 Jul 2019
9 Jul 2019
16 Jul 2019
9 Jul 2019
9 Jul 2019 - 12 Jul 2019
Amount
Laying and Jointing PVC Pipe. Heading
PART -A- HT EQUIPMENTS
11KV DP STRUCTURE Supply, erection, testing and commissioning of 11 KV DP structure using 200x100 mm ISMB for poles and cross channel of ISMC 100x65mm and supporting structure for 11 kV components with cross arms,11 kV pin,disc and stay insulators, supports, jumpering / interconnecting conductors with '0'SWG Cu, anticlimbing arrangement using barbed wire,earthing etc. on a suitable concrete foundation complete including the cost of foundation. The DP structure shall consists of the following. (All the MS items shall be finished using zinc chromate primer & 2 coats of synthetic enamel paint) (Note:The work shall be as per KSEI & KSEB standards) 11 kV, 400A , single brake,TP, gang operated AB switch with operating handle & locking mechanism - 1 No 11 kV Lighting Arrestor -1 set of 3 Nos 11 kV Drop out fuses-1 sets of 3 Nos 11kV outdoor type CT/PT unit with, class 0.5, 15VA CT & 11kV/110V class 0.2, 100VA PT - 1set The DP structure shall be with all necessary accessories for connecting 11kV cable .
Supply, fabricating & erection of 1.8 mtr high chain link fencing over 600 mm high random rubble masonry as per drawing and specification, using 4 mm thick PVC coated chain link with a framework of 50x50x6 mm MS angle between vertical posts of ISMC 75 mm at 2400 mm intervel, which are fixed to the concrete footing (1:3:6) of size 450x450x300 mm (above GL) with adequate footing depth, between the RR masonry. RR masonry (450 mm thick) and 300 mm from ground level for foundation & plinth in in cement mortar (1:6). The random rubble masonry is to be pointed using cement mortar 1:3 to have a flush finish. Earthing as per KSEI/KSEB standards shall be done around the periphery of the fencing.The MS frame work for chain link fencing is finished using zinc chromate primer & 2 coats of synthetic enamel paint. 1.5 mtr wide gate shall be provided with suitable locking arrangements.The rate shall be inclusive of all materials, labour, lead, lift, etc including excavation works and fabrication and assembly works including all nuts, bolts & other miscellaneuos items, etc. complete as per drawing.
Supplying and filling the proposed yard with 40 mm size blue jelly of 150 mm thick including cost and conveyance of all materials, labour charges etc. complete.
METERING PANEL Supply, installation, testing and commissioning of TOD meter KIOSK with TOD meter and test terminal block, control fuses,armoured copper cable between CTPT unit and TOD meter.The KIOSK shall be made out of 2mm thick CRCA sheet steel, totally enclosed, IP 54, weather proof,undergone seven tank process, powder coated finish, earthing, entire civil work including suitable foundation and all mounting accessories as required complete as per the rquirement of K.S.E.B
11kV/0.433kV Transformer Copper wound 11/0.433kV, Outdoor, Oil Cooled, 200kVA, 3Ph., 50Hz, Vector Group: Dyn11, Transformer with Off Circuit Tap Changer from +5% to -10% insteps of 2.5%, Neutral CT for Stand Bye Earth Fault Protection, 11kV porcelain bushing on HV side and LV cable box suitable for termination of LV XLPE cable; with all standard fittings and accessories as required complete in suitable enclosure and losses confirming to IS 1180 level 2 Voltage Ratio: 11/0.433 kV, Type of Winding: Copper, Fittings: Standard fittings as per IS:2026/77. Th LT side should also have a water proof enclosure with 400A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA) on with Low Set Standbye Earth Fault Relay using CT at Neutral Earthing Conductor.
PART-B- LT PANEL BOARDS AND ACCESSORIES
SSB-2 Supply of LT Switch board cubicle type SSB2, made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , suitable spreader etc. The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel(required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. Incomer: 63A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 1no. Busbar : 415V, 35kA, 63A TPN busbar chamber with Aluminium busbar Meters and instruments: RYB Indicating lamps LED type - 3 Nos., 4A SP MCB, C curve - 3 nos, 0-63A Ammeter acc. Class 1 with 90 deg defl. scale - 3 Nos, 0-500V Voltmeter acc. Class 1 with 90 deg defl. Scale - 3 nos ,ON/ OFF/ TRIP indication lamp, LED type - 3 nos , Digital multifunction meter - 1 no Outgoings: 40A HRC fuse with fuse link - 12 nos, Neutral link -4 nos, 40A, FP MCB - 6 nos, 3 phase CT operated type, 415V, 5-10 A flush mounted electronic type energy meter class1 - 4Nos.
PART -C- CABLES AND CABLING HT Cabling
Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date. 3C X 300 sq.mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Cable size exceeding 120 Sq.mm but not exceeding 400 sq.mm
Laying of one no. PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in recess/ surface/ cable tray/ wall with saddles, clamps and all other accessories as required Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 300 sq.mm.
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 300 sq. mm
LT CABLING Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
3.5C 300 Sq.mm Al
3.5C 185 Sq.mm Al
3.5C 120 Sq.mm Al
3.5C 70 Sq.mm Al
4C 35 Sq.mm Al
4C 16 Sq.mm Al
4C 6 Sq.mm Al
4C 2.5 sqmm Cu
4C 1.5 sqmm Cu
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5C 300 Sq.mm Al
3.5C 185 Sq.mm Al
3.5C 120 Sq.mm Al
3.5C 70 Sq.mm Al
4C 35 Sq.mm Al
4C 16 Sq.mm Al
4C 6 Sq.mm Al
4C 2.5 sqmm Cu
4C 1.5 sqmm Cu
LAYING Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall or surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed armoured power cable of 1.1kV grade fo the following sizes in ground including excavation ,sand cushioning , providing protective covering and refilling the trench etc. as required
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required
Providing, laying and fixing following dia RCC pipe NP 2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 100 mm dia
Fabrication, supply and installation of following size of Ladder GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and painting etc as required
300 MM WIDTH X 50 MM DEPTH X 2MM THICK
150 MM WIDTH X 50 MM DEPTH X 2 MM THICK
Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
PART- D-WIRING AND ACCESSORIES
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Note:The total distance from the switch box to the point will not exceed 5mtr, incase if length increases above 5 metres, the wiring shall be measured under item 5.4.1)
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.. (Note:The total distance from the switch box to the point will not exceed 5mtr, incase if length increases above 5 metres, the wiring shall be measured under item 5.4.1)
Group controlled light point with 1.5 sq. mm wire - Wiring for Group controlled light point (from one point to another point) with 3X 1.5 sq. mm PVC insulated, (FRLS), copper conductor cable in surface/recessed mounted rigid medium class 20mm PVC conduit with all accessories as required. ( Note: This item does not include the cost of MCB or 16Amp/ 6Amp one way switches. The total distance from one point to another point will not exceed 5meters. In case if the total length increases 5meters, the additional lengtth shall be measured under item 5.4.1. The distance from DB to 1st point will be measured under item point wiring.
Circuit wiring -Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing following modular switch/ socket with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete.
15/16 amp switch
6 pin 15/16 amp socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing stepped type electronic fan regulator with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)
Supply, fixing of Network point, UTP RJ45, CAT 6 modular type socket with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box, inter connection etc as required complete.
Supply of 4 pair Cat 6 UTP indoor cable with all accessories required as per specification.
Laying of additional one number of CAT 6 UTP indoor cable through Existing 25mm PVC conduit along with accessories in surface as required
Laying of one number of CAT 6 UTP indoor cable through 25mm PVC conduit along with accessories in recess including cutting the wall and making good the same as required.
Laying of one additional number of CAT 6 UTP indoor cable through 25mm PVC conduit along with accessories in recess including cutting the wall and making good the same as required.
Supply of 24 port modular Patch Panel as per specification.
Installation,Testing and Commissioning of 24 port modular Patch Panel as per specification.
Supply of 12 port modular Patch Panel as per specification.
Installation,Testing and Commissioning of 12 port modular Patch Panel as per specification.
Supply of 4U Rack alongwith all necessary hardware & accessories, etc.complete as required as per specification.
Installation,Testing and Commissioning of 4U Rack alongwith all necessary hardware & accessories, etc.complete as required as per specification.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
PART -E- MCBs AND MCB DISTRIBUTION BOARDS Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision of 100 amps TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB's/ MCCB) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way , Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (8 + 12), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (8 + 24), Double door
6 way (8 + 18), Double door
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125 Amp, 16 KA,FPMCCB
Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required
4 pole 25 amps. (415 Volts),30mA sensitivity.
4 pole 40amps. (415 Volts),30mA sensitivity.
4 pole 40amps. (415 Volts),100mA sensitivity.
4 pole 63amps. (415 Volts),30mA sensitivity.
Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required.
6A to 32A, SP, C-CURVE
6A to 32A ,SP D curve
6A to 32A, TP, C-CURVE
40A to 63A, TP, C-CURVE
Supply, Installation, Testing & Commissioning of following isolator in suitable CRCA steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring, etc as required complete. Enclosure : Siemens 8GB32100RC04 or L&T DBENC004SD or equivalent approved make 40 amps FP
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)
Supply installation, testing and commissioning of star delta starter in sheet steel enclosure for 10HP, 3ph motor including auxilliary contactors, and all necessary accessories as required complete.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
PART- F- LIGHT FIXTURES AND FANS
Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 20+/-2 Watts,lumen output of lamp greater than 1500, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watt and including all the necessary accessories as required complete.Make:- Cat No:Wipro LL20-281-XXX-65 or equivalent approved make
Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 10+/-2 Watts,lumen output of lamp greater than 800, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Wipro LL20-111-XXX-60-XX or equivalent approved make
Supply of indoor industrial surface mounted LED tube with Batten along with driver , surge protector,system wattage of 40+/-4 Watts(2x20 watts),lumen output of lamp greater than 3600 lumen, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- Cat No: Wipro WIO 922208 + 2 Nos. of 18W LED Tube Light or Crompton Greaves IGP132LT8-16+LT8-20 or Philips TMC501 2X18W MASTR TLED or equivalent approved make
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supply of surface mounted LED down light made of die cast aluminium, along with driver,system wattage maximum of 18+/-3 Watts,lumen output of lamp greater than 1500 lumens, power factor > 0.9,rated life of L70 @ 40,000 hours, system efficacy greater than 90 lumen/watt and including all necessary accessories as required complete.Make:- Cat No: Wipro CRDL11S023HP57 or equivalent approved make
Supply of LED outdoor lighting luminaire. The fixture shall be of IP66 protected, pressure die cast aluminium housing body with optimal heat sink, with system wattage maximum 40 (+/-5)W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens greater than 3800 lumen and system efficacy greater than or equal to 90lumens/watt ..Make Wipro skyline LR02-451-XXX-57-G1 or equivalent approved make
Supply of following sizes of 1200 mm sweep. 5 star rated ceiling fan, with double ball bearing, Aluminium pressure die cast body with Aluminium blades, canopies, hanging shackle, 30 cm down rod and without speed regulator suitable for 240V 50 HZ, AC supply confirms to IS 374/1979 as required complete. (Make crompton-ENTRUST50 or equivalent approved make).
Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Crompton Brisk Air or equivalant approved make)
Supply of 450 mm sweep,900 rpm heavy duty exhaust fan in metal body with louvers working on 230 V AC supply complete with all accessories as required. (Crompton EXHD 450 -6-1 or equivalant approved make)
ITC LIGHT FITTINGS AND FANS Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of High bay/LED FLOOD type fittings on wall/Column/truss using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 1.5 Sq.mm PVC insulated flexible copper conductor cable as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation, testing and commissioning of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing & commissioning etc as required.
Numbering of ceiling fan / exhaust fan/ fluorescent fitting as required.
PART-G- EXTERNAL LIGHTING SYSTEM Supply, installation, testing and commissioning of 6 m long swaged GI pole along with 45W LED luminaire .The pole shall have built- in control box prewired,concealed wiring with 3Cx 2.5 sq.mm copper wire from the control box to light fixture, and all other accessories complete including necessary civil foundation. The pole shall be coated with epoxy Zinc phosphate primer and finished using polyurethane based paint.The light shall be 45 watts LED street light with , with die cast aluminium body , IP 65, along with driver prewired complete with all necessary accessories as required (Pole Model : Metal coats Monarc lighting pole ID:MC 8109 or Unique pole 6.0m or equivalent approved make. Luminairie Make: Wipro Skyline LR-02 -501 or equivalent approved make)
Supply
Installation
PART-H- EARTHING AND SAFETY EQUIPMENTS Earthing with C.I. earth pipe 4 metre long, 100 mm dia including accessories, and providing masonry enclosure with heavy duty CI cover plate of 300X300mm having locking arrangement and watering pipe etc. with 64kg charcoal/ coke and 5kg salt as required. (As per IS 3043 ammended uptodate)
Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.
25mm X 6mm GI
50mm X 6mm GI
25mm X 3mm Cu
3.15mm Cu (10 SWG)
4mm GI (8 SWG)
Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
25mm X 6mm GI
50mm X 6mm GI
25mm X 3mm Cu
3.15mm Cu (10 SWG)
4mm GI (8 SWG)
PART- I- LIGHTNING PROTECTION
Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3
Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3
Providing and fixing of test joint suitable for hot dipped galvanized steel tape 30 mm x 3mm and 8mm dia solid round aluminium conductor made of stainless steel SS 304 grade. Conforms to the requirements according to (IS/IEC 62305).with an outdoor glass-fibre reinforced polycarbonate enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm.
Providing and laying hot dipped galvanized steel tape 32 mm X3 mm from earth electrode directly in ground as required.
VELS ENGINEERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .