Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹23 L
EMD Value
₹20,000
Closing Date
30 Nov 2026, 4:00 pm5d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EXECUTIVE ENGINEER (O & M) DGVCL MANDVI DIVISION
Tender for ARC for maintenance various capacity of transformer under Madhi Sub Division.
367328
Tender No:38 DGVCLDOMDV/145/11/2026 DT:18.11.2026
Open
Electrical and Maintenance Works
Works
Surat
1 document required · 1 mandatory
₹1,180
DGVCL MANDVI
₹20,000
19 Nov 2026
19 Nov 2026
19 Nov 2026
30 Nov 2026
19 Nov 2026
120 days
Tender for ARC for maintenance various capacity of transformer Of Madhi Sub
Division under mandvi Division.
Sr. No. Description Unit Material Charge (Rs.)
1 Labour charge for providing of HT/LT bushing goti if required No 0 100 (
L.1, Replacement of LT bushing goti/ Rubber washer No.
7.2 Replacement of HT bushing goti/ Rubber washer No
2 Providing of half stud (lncluding 2nos Nut & 2nos Washer) on
LT side up to 100 KVA TR if required
3 Providing of AL. Patta on LT side up to 200 KVA TR if required No. 140
4 Providing of AL. Patta on LT side up to 500 KVA TR if required No 165 L0
Check and tight earth connection, if required provide lugs &
nut-bolt to the neutral terminal of TRF and to the body
terminal of TRF and dist box earth
6 Replacement of damage LT cable with new one of right
capacity (cable provide by DGVCL)
7 Providing a new termination in form of R,Y,B and N core
including PVC Tape(Lug Make 3DlHex)
7.t Termination of 25150/70 Sq.mm cable No. 8
7.2 Termination of 300 Sq.mm cable No 45
7.3 Termination of 95lt2O/150 Sq.mm cable No. 16 20 (
7.4 Termination of 185 Sq.mm cable No 23
7.5 Termination of 24O Sq.mm cable No 32
8 Measurement of voltage and ampere during maximum load
period minimum 10 nos. of T/C per day Per No.
Check oil leakage from drain off valve/gasket/tank leak etc.
and if leakage found at attend by providing adhesive material,
m-seal and give detail of leakage and topping of oil to
maintain proper oil level (oil provide by DGVCL)
10 Checking and Replacement of LT Dist Box if required
10.1 Fixing of new dist. Box with complete wiring including clamps,
nut bolts etc. (Suitable for kit kat fuse/ HRC fuse)LT
distribution box must be of SMC material (GTP/SPECS. to be
submitted of OEM) and to be supplied from register vender of (
GUVNL and their subsidary company all the testing norms will
be applicable to this material.
70.2 Replacement of detoriarated/ providing LT dist. Box with new
up to 100 KVA capacity & crediting it to store. (Suitable for kit
kat fuse/HRC fuse) LT distribution box must be of SMC
material (cfP/SPECS. to be submitted of OEM) and to be
supplied from register vender of GUVNL and their subsidary
company. all the testing norms will be applicable to this mat
10.3 Replacement of detoriarated/ providing LT dist. Box with No. 3150 L603
above 100 KVA capacity & crediting it to store. (Suitable for
kit kat fuse/HRC fuse) LT distribution box must be of SMC
material (GTP/SPECS. to be submitted of OEM) and to be
supplied from register vender of GUVNL and their subsidary
company. allthe testing norms will be applicable to this
tt Checking and replacement of Kit-Kat Fuse if required
11.1 100 amp kit-kat fuse (Fuset to be provided by DGVCL) No. 0
tL.2 200 amp kit-kat fuse (To be provided by Contractor) No. 820
L2 Checking and replacement of HRC fuse base if required (HRC fuse base to be provided by contractor
on std Make with type test certificate required)
L2.L 630 amp HRC fuse base No. 682
72.2 400 amp HRC fuse base No 525
L2.3 250 amp HRC fuse base No 370
L3 Checking and replacement of HRC fuse bridge if required (HRC fuse bridge to be provided by
contractor on std make with type test certificate required)
13.1 630 amp HRC fuse No. 690
13.2 400 amp HRC fuse No 490
13.3 250 amp HRC fuse No. 352
L4 Providing of proper size of fuse element on HT side (on D.O.
fuse with cleaning of horns)
15 Providing and replacement of sundry items like nut, bolt,
washer etc. of appropriate size
L6 General condition
L6.7 Clean off all dirt etc from the body of the transformer and
tighten all nut-bolt etc.
16.2 Clamping of LT cable as per instruction of in charge supervisor
16.3 Cleaning of surrounding area nearby transformer center,
treeming of tree branches, removing of crimpers etc.
16.4 Submission of the all activity done at location wise in
prescribed proforma format with signature of in charge of
supervisor and contractor
15.5 Providing of breather if not available with transformer
(breather to be provided by DGVCL)
16.6 Providing of insulated jumper at HT side from D.O. fuse out
side to TC. Allthree nos. (Jumper wire will be provided by
1.6.7 Meggar Value taken (1) HV to Body (2) LV to Body (3) HV to
16.8 Tc maintenance digital data submitted as per instruction of
Engineer ln charge. l
Supply & providing of neutral earthing using G.l. strip (Size 25 \
L7 mm x 3mm flat) to neutral terminal of X'mer and disl. Box No. 255
neutralterminalwith 3 Mtr PVC rigid pipe. 20 Kg solt + 20 Kg
coal. G.l. strip should be brought proper shape up to the
equipment (Earth resistance to be measured and earth
resistance to be maintained as per std norms of DGVCL.
(Earthing Plate Provided by DGVCL)
18.1 LT Side Brass half stud with 2 no brass nut & washer of size
!8.2 LT Side Brass half stud with 2 no brass nut & washer of size
19 LT Side Brass Nuts and washer
19.7 12 mm Brass LT side nuts No. 16
19.2 20 mm Brass LT side nuts No. 4L L2
19.3 30 mm Brass LT side nuts No. 68 !2
79.4 12 mm Brass LT side washer No. 10 L2
19.5 20 mm Brass LT side washer No. 18 L2
19.6 30 mm Brass LT side washer No. 20 L2
20.L Breather plastic transparent body cast metal cap and bottom,
1/2" thread pipe,250 grams. (Dry gelweight 250 gm)
20.2 Breather plastic transparent body cast metal cap and bottom,
1/2" thread pipe,500 grams.( Dry gel weight 500 gm)
Total Amount (Twenty three Lakh) (Excluding GST)
Total Amount (Twenty three Lakh) (Excluding GST)
MANDVI DIVISION
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
General Terms and condition1 madhi.pdf
Integrity pact.pdf
NecessaryDocuments.pdf
Notice tc maintenance madhi.pdf
SCH B TC Maintenance Madhi sign.pdf
Technical specification MND.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .