Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance NEAR RAMNAGAR ROAD NO 2 AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | 799002 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance JOYNAGAR MIDDLE ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹7.7 L
EMD Value
₹15,332
Closing Date
12 Aug 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Providing, Installation, Testing and Commissioning of Split Type Air Conditioning System and Water Cooler at Tripura State Guest House during the year 2024 25
2024_CEPWD_51349_1
35/EE/DNIeT/MECH.DIVN/AGT/2024
Open Tender
Electrical Works
Works
5 days
AGARTALA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹15,332
12 Aug 2024
6 Aug 2024
12 Aug 2024
6 Aug 2024
12 Aug 2024
6 Aug 2024
Amount
Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split /window type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS (Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity
2.0 TR split type high wall AC machine (rated cooling capacity should not be less than 6000 Kcal/hr or 24000 BThu/hr or 7000 watt)
Providing floor mounting vertical type split AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall/ceiling mounting conforming to IS (Part-II) specification (Except power consumption) suitable for operation on 420 volt, 50 Hz, three phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity
4.0 TR floor mounting vertical type split AC machine (rated cooling capacity should not be less than 12000 Kcal/hr or 48000 BThu/hr or 14000 watt)
Standard installation, testing and commissioning of 1.0/1.5/2.0 TR split and window type machine including hole cutting, finishing etc as per direction of the Engineer-in-charge.
Standard installation, testing and commissioning of 3.0/4.0 TR floor mounting vertical split type AC machine including hole cutting, finishing etc as per direction of the Engineer-in-charge.
Fabrication of M.S platform for placement of condensing unit by using M.S angle of (65x65x5) or (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Supply, installation of additional length of copper pipe beyond 10 ft length of 5/8”, 3/8", 3/4" 1/2" and 1/4” diameter for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units.
Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge.
Providing, installation, testing and commissioning of water cooler 150Lt/hr Cooling and storage capacity - 150 L, conforming to IS 1475 Part 1 (Latest), suitable for operation on 230 v ± 10%, 50 hz single phase AC supply, thermal insulation for storage tank-PUF or higher grade to keep the water cool for longer period., number of faucets- 2, storage tank and drain tray material -SS 304 or higher grade, outer body material- panel: SS 304 or higher grade and rest CRCA powder coated steel or higher grade, faucet material-Brass (Cr plated) or higher grade, auto cut-out, voltage overload compressor protection, provided & fitted with water tank level switch inside water cooler to switch off the purifier on attaining the desired level of water inside water tank of water cooler, all conforming to mentioned standards & other Indian standards covering the product, and with all type of water pipe fittings & accessories etc complete. The product shall be manufacturer's standard tested latest model being in successful use in market for at least last 3 (three) years.
R.P.ELECTRONICS (BID ID -146734)
stage.html
html • 0.02 MB
finance_52219.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .