| 1.00 | Supply, installing, commissioning and testing eco-friendly diesel engine driven generating set silent type, canopy as per CPCB-IV+ norms 12 KW/15 KVA, 0.8 power factor Emission limits as NOx +HC ≤ 7.5, CO ≤3.5,PM 2.5 ≤0.3 smoke limit (light absorption coefficient M¯1≤ 0.7, directly coupled alternator & engine, coolent base cooling system, including all excavation & earth work, PCC foundation, anti vibration pads / dampers, control panel and other accessories as per manufacturer’s design and comprising of the following:-
(a) ALTERNATOR : Self regulated with brushless self excitation 15 KVA 415 V, 3 phase, 4 wire, 50 HZ, 0.8 P.F.,1500 RPM, with voltage variation plus or minus 2.5 % of rated voltage from no-load to full-load, foot mounted, screen protected, class 'F' insulation with necessary controls as recommended by the manufacturers, conforming to IS-5000/IS-4722.
Make :- Stamford, Kirloskar electric, Jyoti, Leroy Somer
(b) Engine : Multi cylinder,compression ignition, heavy duty,compact diesel engine water cooled with standard accessories, all as per BS-8528-1 (2013) /IS-3046, 1500 RPM,control gauges, RPM/Hours meters etc; shaft H.P. suitable for generating application and capable of giving an output of 15KVA/ 12 KW for coupled alternator under NTP conditions.
Make :- Kirloskar, Cummins, Ashol Leyland, Crompton Greaves
(c) AMF Panel : AMF panel shall be inbuilt with DG set or as per manufacturer recommendation and design alongwith all control and power wiring and suitable rating switchgear, auto/ manually arrangement, standby chageover switch in case of failure of AMF & Other accessories, if any , as per manufacturer instructions
make of switchgears : L&T, Havells, Legrand , C&S, Schneider or equivalent
Notes for item srl No. 1 : (I) Contractor will satisfactorily conduct load test of DG set as per instruction of testing officer for 12 hours including run on 10% overload for 1 hour.
(ii) Testing eqpt will be arranged by the contractor.
(iii) Fuel/oil required for load test shall be arranged by the contractor and cost thereof is deemed to be included in the lump sum amount quoted by the contractor
(iv) Three sets of following documents :- Maintenance and operation manuals for engine and alternator, spare parts catalogue, warranty/test certificates, schematic diagrams of control panels. | 1 | Each | 5,50,000 ₹5,50,000 Lowest | 5,80,000 ₹5,80,000 |
| 2.00 | Supply, commissioning, testing of front openable sliding glass door transparent glass type open chillar 3000 ltrs (horizontal type) dimesnion of 2850 mm length x 850 mm depth x 2090 mm height alongwith suitable tonnage of cooling compressure capacity for refrigeration (maintain temprature range + 02° C to +08° C ) and internal lighting, auto defrost, automatic temprature control, remote operation, adjustable rack-04 Nos including base rack with 1" PVC bumpers, 30 ° inclined (tiltable racks) for store of fruits and vegetables, complete all as specified and as directed.
Make :York, Daikin, Blue star, Carrier,Voltas or equivalent | 2 | Each | 4,50,000 ₹9,00,000 Lowest | 5,20,000 ₹10,40,000 |
| 3.00 | Supply, commissioning, testing of front openable sliding glass door transparent glass type open chillar 3000 ltrs (horizontal type) dimesnion of 2850 mm length x 850 mm depth x 2090 mm height alongwith suitable tonnage of cooling compressure capacity for refrigeration (maintain temprature range +02 deg to +08 deg ) and internal lighting, auto defrost, automateic temprature control, remote operation, adjustable rack-04 Nos including base rack with 1" PVC bumpers, plane (Non tiltable racks) surface to store egg and bread, complete all as specified and as directed.
Make :York, Daikin, Blue star, Carrier,Voltas or equivalent | 1 | Each | 4,50,000 ₹4,50,000 Lowest | 5,20,000 ₹5,20,000 |
| 4.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor size 25 sq mm 4.0 core,complete all as specified. | 90 | RM | 220 ₹19,800 Lowest | 300 ₹27,000 |
| 5.00 | M & L for Excavation in trenches not exc.1.5 mtr wide and not exc.1.5 m in depth for laying of pipes as in soft soil and getting out, complete all as specified and directed. | 21.6 | CUM | 100 ₹2,160 Lowest | 100 ₹2,160 Lowest |
| 6.00 | M & L for Returning, filling, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete all as specified and directed. | 15.12 | CUM | 80 ₹1,209.6 | 50 ₹756 Lowest |
| 7.00 | M & L for Removal of excavated material to a distance not exc.50 m and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as directed. | 4.58 | CUM | 80 ₹366.4 | 50 ₹229 Lowest |
| 8.00 | M&L for Sand cushioning using sand suitable for plaster works to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep punned to 10cm after laying and stretching the cable complete all as specified and directed. Note : 18 cm punned thickness shall be measured and paid. | 6.48 | Cum | 550 ₹3,564 Lowest | 1,000 ₹6,480 |
| 9.00 | Supply and lay cable protection cover with Bricks; common burnt clay building bricks, sub-class ‘B’ designation 75, (size 23cmx11.5cmx7.5cm) putting accross the cable with width of protection cover equal to length of brick, abutting to each other for cable protection complete all as specified and directed. | 0.64 | Per 1000 Nos | 4,500 ₹2,880 Lowest | 7,500 ₹4,800 |
| 10.00 | Supply and fixing of industrial type wall mounted socket 230/415 Volt, 20 Amp rating incl MCB 16 Amp triple pole and earth with IP-44 protection for electric supply connection of chillar plant connection complete all as specified and as directed. | 4 | Each | 750 ₹3,000 Lowest | 5,000 ₹20,000 |
Tender Value
Refer Docs
EMD Value
₹43,000
Closing Date
13 Nov 2025, 6:00 pmClosed
CWE FEROZEPUR CANTT
HQ CWE Ferozepur Cantt PIN 152001
PROVN OF 03 X CHILLERS (3000 LTR CAPACITY) AND 01 X 15 KVA GENERATOR FOR (I) SUP PL ASC AT DHOLEWAL MIL COMPLEX UNDER GE LUDHIANA
2025_MES_736854_1
CWE/FZR-48/2025-26
Open Tender
Civil Works
Item Rate
180 days
LUDHIANA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE LUDHIANA
₹43,000
Yes
17 Jan 2026
25 Oct 2025
20 Nov 2025
25 Oct 2025
13 Nov 2025
8 Nov 2025
Amount
Supply, installing, commissioning and testing eco-friendly diesel engine driven generating set silent type, canopy as per CPCB-IV+ norms 12 KW/15 KVA, 0.8 power factor Emission limits as NOx +HC ≤ 7.5, CO ≤3.5,PM 2.5 ≤0.3 smoke limit (light absorption coefficient M¯1≤ 0.7, directly coupled alternator & engine, coolent base cooling system, including all excavation & earth work, PCC foundation, anti vibration pads / dampers, control panel and other accessories as per manufacturer’s design and comprising of the following:- (a) ALTERNATOR : Self regulated with brushless self excitation 15 KVA 415 V, 3 phase, 4 wire, 50 HZ, 0.8 P.F.,1500 RPM, with voltage variation plus or minus 2.5 % of rated voltage from no-load to full-load, foot mounted, screen protected, class 'F' insulation with necessary controls as recommended by the manufacturers, conforming to IS-5000/IS-4722. Make :- Stamford, Kirloskar electric, Jyoti, Leroy Somer (b) Engine : Multi cylinder,compression ignition, heavy duty,compact diesel engine water cooled with standard accessories, all as per BS-8528-1 (2013) /IS-3046, 1500 RPM,control gauges, RPM/Hours meters etc; shaft H.P. suitable for generating application and capable of giving an output of 15KVA/ 12 KW for coupled alternator under NTP conditions. Make :- Kirloskar, Cummins, Ashol Leyland, Crompton Greaves (c) AMF Panel : AMF panel shall be inbuilt with DG set or as per manufacturer recommendation and design alongwith all control and power wiring and suitable rating switchgear, auto/ manually arrangement, standby chageover switch in case of failure of AMF & Other accessories, if any , as per manufacturer instructions make of switchgears : L&T, Havells, Legrand , C&S, Schneider or equivalent Notes for item srl No. 1 : (I) Contractor will satisfactorily conduct load test of DG set as per instruction of testing officer for 12 hours including run on 10% overload for 1 hour. (ii) Testing eqpt will be arranged by the contractor. (iii) Fuel/oil required for load test shall be arranged by the contractor and cost thereof is deemed to be included in the lump sum amount quoted by the contractor (iv) Three sets of following documents :- Maintenance and operation manuals for engine and alternator, spare parts catalogue, warranty/test certificates, schematic diagrams of control panels.
Supply, commissioning, testing of front openable sliding glass door transparent glass type open chillar 3000 ltrs (horizontal type) dimesnion of 2850 mm length x 850 mm depth x 2090 mm height alongwith suitable tonnage of cooling compressure capacity for refrigeration (maintain temprature range + 02° C to +08° C ) and internal lighting, auto defrost, automatic temprature control, remote operation, adjustable rack-04 Nos including base rack with 1" PVC bumpers, 30 ° inclined (tiltable racks) for store of fruits and vegetables, complete all as specified and as directed. Make :York, Daikin, Blue star, Carrier,Voltas or equivalent
Supply, commissioning, testing of front openable sliding glass door transparent glass type open chillar 3000 ltrs (horizontal type) dimesnion of 2850 mm length x 850 mm depth x 2090 mm height alongwith suitable tonnage of cooling compressure capacity for refrigeration (maintain temprature range +02 deg to +08 deg ) and internal lighting, auto defrost, automateic temprature control, remote operation, adjustable rack-04 Nos including base rack with 1" PVC bumpers, plane (Non tiltable racks) surface to store egg and bread, complete all as specified and as directed. Make :York, Daikin, Blue star, Carrier,Voltas or equivalent
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor size 25 sq mm 4.0 core,complete all as specified.
M & L for Excavation in trenches not exc.1.5 mtr wide and not exc.1.5 m in depth for laying of pipes as in soft soil and getting out, complete all as specified and directed.
M & L for Returning, filling, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete all as specified and directed.
M & L for Removal of excavated material to a distance not exc.50 m and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as directed.
M&L for Sand cushioning using sand suitable for plaster works to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep punned to 10cm after laying and stretching the cable complete all as specified and directed. Note : 18 cm punned thickness shall be measured and paid.
Supply and lay cable protection cover with Bricks; common burnt clay building bricks, sub-class ‘B’ designation 75, (size 23cmx11.5cmx7.5cm) putting accross the cable with width of protection cover equal to length of brick, abutting to each other for cable protection complete all as specified and directed.
Supply and fixing of industrial type wall mounted socket 230/415 Volt, 20 Amp rating incl MCB 16 Amp triple pole and earth with IP-44 protection for electric supply connection of chillar plant connection complete all as specified and as directed.
S & F sheet metal enclosure for double door DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted VTP & N 12 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for fixing of MCCB 100 amp, 4 pole and isolators etc including fixing in Wall with Cement mortar complete all as specified and directed
Supply and fixing MCCB 100 of Amp rating of Icu= Ics= 100 % , 25 KA, 4 pole of thermal and magnetic adjustable both, complete all as specified and as directed.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of 04 poles and 40 Amp current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
M&L for submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 4.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 4.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 4.0Sqmm and one run of 4.0Sqmm PVC insulated copper conductor single core (2x4.0Sqmm+1x4.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run)
M&L for Earthing in replacement complete with Galvanised Steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of plate not less than 1.5m below normal ground level ,connected to and including Galvanised Steel earth strip 32X6mm by means of nut, bolts, check nuts and washers made of copper alloy and connection to test point and earth dolly and provision of charcoal dust and common salt packed all around the earth plate including watering pipe and protection pipe, necessary excavation and earth work in soft/loose soil and testing complete all as specified and directed and as shown in Electrical Plate No. 3 of MES SSR-2009 Part-I (Specifications) complete with the following:- (a) Excavation and earth work for drilling hole for electrode in any type of Soil/rock strata. (b) PCC chamber in cement concrete 1:3:6 type C-1, Pre-cast RCC cover with CI frame with suitable handle 50 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with 15mm bore galvanised iron light grade watering pipe and lugs etc complete all as specified and directed. (d) 40 mm bore galvanised iron light grade protection pipe for protection of earthing lead and earth lead, each 7.5m long complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. Note:-GI earth strip and 50mm medium grade GI protection pipe upto 7.5m each shall be deemed to be included in quoted rate of this item. (ii) If the desire earth resisitance not obtained on testing after completion, earthing shall be redone by the contractor without any extra cost upto obtain the desired resistance. (iii) Tibba sand shall be shall be used by the contractor after filling of salt and charcoal for earthing.
M&L for Earthing in replacement complete with Galvanised Steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of plate not less than 1.5m below normal ground level ,connected to and including GI wire 4mm dia (8 SWG) connected to GI earth plate electrode by means of nut, bolts, check nuts and washers made of copper alloy and connection to test point and earth dolly and provision of charcoal dust and common salt packed all around the earth plate including watering pipe and protection pipe, necessary excavation and earth work in soft/loose soil and testing complete all as specified and directed and as shown in Electrical Plate No. 3 of MES SSR-2009 Part-I (Specifications) complete with the following:- (a) Excavation and earth work for drilling hole for electrode in any type of Soil/rock strata. (b) PCC chamber in cement concrete 1:3:6 type C-1, Pre-cast RCC cover with CI frame with suitable handle 50 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with 15mm bore galvanised iron light grade watering pipe and lugs etc complete all as specified and directed. (d) 40 mm bore galvanised iron light grade protection pipe for protection of earthing lead and earth lead, each 7.5m long complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. Note:-GI earth strip and 50mm medium grade GI protection pipe upto 7.5m each shall be deemed to be included in quoted rate of this item. (ii) If the desire earth resisitance not obtained on testing after completion, earthing shall be redone by the contractor without any extra cost upto obtain the desired resistance. (iii) Tibba sand shall be shall be used by the contractor after filling of salt and charcoal for earthing.
JASSI TRADERS (BID ID -3473639)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.57 MB
BOQ_825060.xls
BOQ • 1.02 MB
TENDER48.pdf
Tender Documents • 2.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .