Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC D NO 58 13 74 10 GF 111 VASAVI PARADISE GOWRI NAGAR WARD NO 42 NAD POST VISAKHAPATNAM 530009 AP | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.7 L+₹97,460 (12.6%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | Rejected-Technical ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | - | Rejected-Technical Not Meeting Eligibility Criteria.Requiste documens (DD) not submitted. |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
5 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Nitesh K Singh, IDSE AEE AGE (I) R and D NSTL
AGE (I) R and D, NSTL Complex, Visakhapatnam 530027
8426 REPAIRS/ MAINTENANCE TO HT 33/11 KV VCBS AND RMUs ALONG WITH CONNECTED ALLIED WORKS AT TECHNICAL AREA, NSTL UNDER AGE (I) R n D NSTL, VISAKHAPATNAM
2022_MES_562887_1
AGE I R AND D NSTL VIZAG 8426
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Visakhapatnam
Class E Category b(iii)
7 documents required · 7 mandatory
₹500
AGE I R and D NSTL Visakhapatnam
₹18,000
Yes
1 Feb 2023
14 Nov 2022
7 Dec 2022
14 Nov 2022
5 Dec 2022
21 Nov 2022
Amount
M &L for Dis-connecting the HT 11KV VCB/SF6 panel indoor / outdoor rupturing capacityof 250 MVA/350 MVA ,400 to 1600 Amps, Over hauling /servicing /decarbonising of contacts and live conductors/busbar of complete panel by taking out the trolley of the breaker, opening the total mechanism of breaker checking its contact, baffle plates and other minor parts, cleaning the complete accessories carefully. Minor repairs shall be rectified, Parts/accessories shall be cleaned, the tank, baffle plates, rotating contact, upper supports, lower supports, greesing & oiling of moving parts,drive assemblies and all other spare parts. Reassembled after repair/ replacement of the spare parts including calibration, testing of existing IDTM,over cureent &earth fault relays as per load parameter complete all as specified and directed by Engineer-in-Charge. Note:-(i) Repair work shall be carried out only by the authorised technician for VCB. (ii) Spare parts as required for replacement of existing worn out parts shall be measured and paid separately under appropriate items.(iii) Labour for replacement/fixing of the supply only items shall be deemed to be included in the unit rate quoted against this item.
Supply only Spout bushing for Indoor 11 KV 400 to 1600 Amps VCB Make SCHNIDER/ABB/KIRLOSKAR complete assembly for lower side
Supply only Spout bushing for Indoor 11 KV 400 to 1600 Amps VCB Make SCHNIDER/ABB/KIRLOSKAR complete assembly for upper side
Supply only 400 to 800 amps. Contact plugs (upper)
Supply only1250 amps. Contact plugs (upper)
Supply only 400 to 800 amps. Contact plugs (lower)
Supply only 1250 amps. Contact plugs (lower)
Supply only 400 to 800 Amps Finger Contact assembly
Supply only Vacuum interrupter bottle for 11 KV indoor/outdoor VCB 4 inch-dia Make: CG/Siemens/ABB/KIRLOSKAR
Supply only Vacuum interrupter bottle for 11 KV indoor/Outdoor VCB 3 inch-dia Make: CG/Siemens/ABB/KIRLOSKAR
Supply only Spring charging motor assbly. 110/230 v ac/dc for 11 KV Indoor / Outdoor VCB
Supply only Closing spring assembly.
Supply only Motor cut-off limit switch
Supply only Butterfly switch
Supply only Ratcet handle
Supply only Auxilary switch (6 no + 6 nc)
Supply only Auxilary switch (7 no + 7 nc)
Supply only Holding catch
Supply only Big cam with main shaft
Supply only Tripping shaft with springs
Supply only Closing shaft with springs
Supply only TNC Switch
Power pack with battery backup 230 V AC input and 110 Volt DC output.
VRLA sealed Maintanance Free dry battery 2 Volts 100 AH Make Exide/Amara raja
Supply only Clossing/Tripping coil assembly
Supply and Fixing electronic hooter 230/110/24 Volts AC/Dc for VCB square type as required at site flush mounted of size 96mm x 96mm suitable for HT VCB 630/400 Amp including making connection with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement indicator lamp in different colour code LED/Neon type complete suitable for HT VCB 630/400 Amp including making with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supplying, installing, testing, calibrating and comissioning of the IDMT relays with instant tripping system, working voltage 110 V, EF 10% to 40% in 50% to 200% in advance including taking out the existing inserviceable IDMT relay (CG114N/CG114S) complete all as specified and as directed by Engineer-in-Charge.
Supplying, installing, testing, calibrating and comissioning of the master trip relays , working voltage 110 V complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement current transformer 11KV epoxy cast wound, CT of ratio 100/50/5A class-I including necessary connection etc. including testing and commissioning complete all as specified and as directed.
PVC insulated Copper Cable 1.5 Sqmm single core
PVC insulated Copper Cable 2.5 Sqmm single core
Supply only heaters for 11 KV VCB of Make :ABB/SCHNEIDER ELECTRIC/KIRLOSKAR
M &L for repairing/servicing,calibrating/testing/setting of fault tripping and recommissioning as mentioned in maintenance and operation manual of 11 KV HT RMU SF6 breaker 3 way/4 way/5 way all as per OEM instructions. Note :-SF6 gas charging will be measured and paid separately. (i) Repairing/servicing shall be carried out through OEM manufactures Engineer/technicians only. (ii) Cost of minor spare parts like gasket,battery,O ring nuts,bolts and lubricants/cleaning required for servicing of RMU is deemed to be included in the coated rate.However cost of major spare parts wii be measured and paid separately under relevant items of sch 'A'. (iii) Job of repairing/servicing/calibrating/testing/setting of fault tripping and recommissioning has been consider for complete set of RMU's i.e.3 way/4 way/ 5 way as per loaction.
M &L for gas charging breaker by using SF6 gas all as specified and directed by Engr-in-charge.
M&L for saver mechanism ON/OFF operating complete with main spring,fire stick,tripping coil system etc for RMU.
S&F actuator motor for operating mechanism charging motor ON/OFF for RMU
S&F self powered relay suitable for RMU.
S&F Lemun type live indicator complete with electrical circuit suitable for RMU
S&F power card (SMPS Card) complete with all electrical circuit suitable for RMU
S&F right angle boot for RMU
M & L for servicing/Overhauling of 2 pole/4 pole structure air break gang operated switches vertical/Horizontal mounted including insulators and operating mechanism for repair/replacement of broken/worn out components such as insulators,nut/bolts GI pipe complete with oiling,greesing of operating mechanism and also painting etc all as specified and directed by Engineer-in-charge.
M &L for Dis-connecting the HT 33 KV VCB/SF6 panel indoor / outdoor rupturing capacity of 630Amps,31.5 KA,36 KV Over hauling /servicing /decarbonising of contacts and live conductors/busbar of complete panel by taking out the trolley of the breaker, opening the total mechanism of breaker checking its contact, baffle plates and other minor parts, cleaning the complete accessories carefully. Minor repairs shall be rectified, Parts/accessories shall be cleaned, the tank, baffle plates, rotating contact, upper supports, lower supports, greesing & oiling of moving parts,drive assemblies and all other spare parts. Reassembled after repair/ replacement of the spare parts including calibration, testing of existing IDTM,over cureent &earth fault relays as per load parameter complete all as specified and directed by Engineer-in-Charge. Note:-(i) Repair work shall be carried out only by the authorised technician for VCB. (ii) Spare parts as required for replacement of existing worn out parts shall be measured and paid separately under appropriate items.(iii) Labour for replacement/fixing of the supply only items shall be deemed to be included in the unit rate quoted against this item.
SRI SAI KRISHNA ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .